The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Novel pyrene- and anthracene-based Schiff base derivatives as Cu2+and Fe3+fluorescence turn-on sensors and for aggregation induced emissions
Abstract
Novel pyrene- and anthracene-based Schiff base derivatives P1 and A1 were synthesized via a one-pot reaction and utilized as fluorescence turn-on sensors towards Cu2+ and Fe3+ ions, respectively, and for aggregation induced emissions (AIEs). P1 in CH3CN and A1 in THF illustrated the fluorescence turn-on sensing towards Cu2+ and Fe3+ ions, respectively, via chelation enhanced fluorescence (CHEF) through excimer (P1–P1* and A1–A1*) formation. The 2 : 1 stoichiometry of the sensor complexes (P1 + Cu2+ and A1 + Fe3+) were calculated from Job plots based on UV-Vis absorption titrations. In addition, the binding sites of sensor complexes (P1 + Cu2+ and A1 + Fe3+) were well established from the 1H NMR titrations and supported by the fluorescence reversibility by adding metal ions and PMDTA sequentially. The detection limits (LODs) and the association constant (Ka) values of P1 + Cu2+ and A1 + Fe3+ sensor responses were calculated by standard deviations, linear fittings and from their fluorescence binding isotherms. More importantly, P1 + Cu2+ and A1 + Fe3+ sensors were found to be active in wide ranges of pHs (1–14 and 2–14, respectively). Moreover, the time effect along with the enhancements of quantum yield (Φ) and time resolved photoluminescence (TRPL) decay constant (τ) towards sensor responses were investigated. Similarly, P1 in CH3CN and A1 in THF showed AIEs by increasing the aqueous media concentration from 0% to 90%, with altered fluorescence peak shifts (red and blue shifts, respectively). As well as τ value enhancements, the Φ values of 0.506 and 0.567 (with 630- and 101-fold enhancements) were acquired for P1 in CH3CN : H2O (20 : 80) and A1 in THF : H2O (40 : 60), respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new generation of Ca2+ indicators with greatly improved fluorescence properties.
Grynkiewicz, G., Poenie, M., & Tsien, R. Y. (1985) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)83641-4 · Cited by 21,607
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Hong, Y., Lam, J. W. Y., & Tang, B. Z. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15113d · Cited by 6,363
Aggregation-induced emission: phenomenon, mechanism and applications
Hong, Y., Lam, J. W. Y., & Tang, B. Z. (2009) · Chemical Communications · doi:10.1039/b904665h · Cited by 4,115
Conjugated Polymer-Based Chemical Sensors
McQuade, D. T., Pullen, A. E., & Swager, T. M. (2000) · Chemical Reviews · doi:10.1021/cr9801014 · Cited by 3,718
Fluorogenic and Chromogenic Chemosensors and Reagents for Anions
Martínez-Máñez, R., & Sancenón, F. (2003) · Chemical Reviews · doi:10.1021/cr010421e · Cited by 3,076
Metals in Neurobiology: Probing Their Chemistry and Biology with Molecular Imaging
Que, E. L., Domaille, D. W., & Chang, C. J. (2008) · Chemical Reviews · doi:10.1021/cr078203u · Cited by 2,061
New sensing mechanisms for design of fluorescent chemosensors emerging in recent years
Wu, J., Liu, W., Ge, J., Zhang, H., & Wang, P. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00224k · Cited by 1,858
Astruc, D., Boisselier, E., & Ornelas, C. (2010) · Chemical Reviews · doi:10.1021/cr900327d · Cited by 1,844
Aragay, G., Pons, J., & Merkoçi, A. (2011) · Chemical Reviews · doi:10.1021/cr100383r · Cited by 1,396
Cross-Reactive Chemical Sensor Arrays
Albert, K. J., Lewis, N. S., Schauer, C. L., Sotzing, G. A., Stitzel, S. E., Vaid, T. P., & Walt, D. R. (2000) · Chemical Reviews · doi:10.1021/cr980102w · Cited by 1,284
Piontek, K., Antorini, M., & Choinowski, T. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m204571200 · Cited by 909
Wang, M., Zhang, G., Zhang, D., Zhu, D., & Tang, B. Z. (2010) · Journal of Materials Chemistry · doi:10.1039/b921610c · Cited by 852
Zhang, J. F., Zhou, Y., Yoon, J., & Kim, J. S. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15028f · Cited by 826
A Selective Turn-On Fluorescent Sensor for Imaging Copper in Living Cells
Zeng, L., Miller, E. W., Pralle, A., Isacoff, E. Y., & Chang, C. J. (2006) · Journal of the American Chemical Society · doi:10.1021/ja055064u · Cited by 806
Iron(iii) selective molecular and supramolecular fluorescent probes
Sahoo, S. K., Sharma, D., Bera, R. K., Crisponi, G., & Callan, J. F. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35152h · Cited by 779
The Art of Fluorescence Imaging with Chemical Sensors
Schäferling, M. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201105459 · Cited by 721
Du, J., Hu, M., Fan, J., & Peng, X. (2012) · Chemical Society Reviews · doi:10.1039/c2cs00004k · Cited by 688
Lieberman, R. L., & Rosenzweig, A. C. (2005) · Nature · doi:10.1038/nature03311 · Cited by 670
Luminogenic polymers with aggregation-induced emission characteristics
Qin, A., Lam, J. W. Y., & Tang, B. Z. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.08.002 · Cited by 441
Ratiometric Displacement Approach to Cu(II) Sensing by Fluorescence
Royzen, M., Dai, Z., & Canary, J. W. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0431051 · Cited by 415
Hong, Y., Meng, L., Chen, S., Leung, C. W. T., Da, L.-T., Faisal, M., Silva, D.-A., Liu, J., Lam, J. W. Y., Huang, X., et al. (2012) · Journal of the American Chemical Society · doi:10.1021/ja208720a · Cited by 388
Engineering Novel Metalloproteins: Design of Metal-Binding Sites into Native Protein Scaffolds
Lu, Y., Berry, S. M., & Pfister, T. D. (2001) · Chemical Reviews · doi:10.1021/cr0000574 · Cited by 375
Maity, D., & Govindaraju, T. (2012) · Chem. Commun. · doi:10.1039/c1cc16064h · Cited by 330
An indirect approach for anion detection: the displacement strategy and its application
Lou, X., Ou, D., Li, Q., & Li, Z. (2012) · Chemical Communications · doi:10.1039/c2cc33158f · Cited by 272
Living with Iron (and Oxygen): Questions and Answers about Iron Homeostasis
Theil, E. C., & Goss, D. J. (2009) · Chemical Reviews · doi:10.1021/cr900052g · Cited by 265
Colorimetric Test Kit for Cu2+ Detection
Sheng, R., Wang, P., Gao, Y., Wu, Y., Liu, W., Ma, J., Li, H., & Wu, S. (2008) · Organic Letters · doi:10.1021/ol802117p · Cited by 222
Self-citationSilva-Junior, M. R., & Thiel, W. (2010) · Journal of Chemical Theory and Computation · doi:10.1021/ct100030j · Cited by 199
Maity, D., Manna, A. K., Karthigeyan, D., Kundu, T. K., Pati, S. K., & Govindaraju, T. (2011) · Chemistry – A European Journal · doi:10.1002/chem.201101906 · Cited by 184
Rationally designed fluorescence ‘turn-on’ sensor for Cu2+
Ko, K. C., Wu, J.-S., Kim, H. J., Kwon, P. S., Kim, J. W., Bartsch, R. A., Lee, J. Y., & Kim, J. S. (2011) · Chemical Communications · doi:10.1039/c0cc05421f · Cited by 169
Metal-Ion-Responsive Fluorescent Probes for Two-Photon Excitation Microscopy
Sumalekshmy, S., & Fahrni, C. J. (2011) · Chemistry of Materials · doi:10.1021/cm1021905 · Cited by 169
Optical Chemosensor for Ag+, Fe3+, and Cysteine: Information Processing at Molecular Level
Kumar, M., Kumar, R., & Bhalla, V. (2010) · Organic Letters · doi:10.1021/ol102543e · Cited by 169
Mameli, M., Aragoni, M. C., Arca, M., Caltagirone, C., Demartin, F., Farruggia, G., Filippo, G. D., Devillanova, F. A., Garau, A., Isaia, F., et al. (2009) · Chemistry - A European Journal · doi:10.1002/chem.200902005 · Cited by 144
A Fluorescence Turn‐on Sensor for Iodide Based on a Thymine–HgII–Thymine Complex
Ma, B., Zeng, F., Zheng, F., & Wu, S. (2011) · Chemistry - A European Journal · doi:10.1002/chem.201102024 · Cited by 123
Song, P., Chen, X., Xiang, Y., Huang, L., Zhou, Z., Wei, R., & Tong, A. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm12098k · Cited by 118
Chemical Sensors and Biosensors—Principles and Applications
Cammann, K., Lemke, U., Rohen, A., Sander, J., Wilken, H., & Winter, B. (1991) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199105161 · Cited by 114
A small change in molecular structure, a big difference in the AIEE mechanism
Cai, M., Gao, Z., Zhou, X., Wang, X., Chen, S., Zhao, Y., Qian, Y., Shi, N., Mi, B., Xie, L., et al. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp23040b · Cited by 113
1,3,5-Triphenylbenzene fluorophore as a selective Cu 2+ sensor in aqueous media
Sirilaksanapong, S., Sukwattanasinitt, M., & Rashatasakhon, P. (2011) · Chemical Communications · doi:10.1039/c1cc16148b · Cited by 99
Dwivedi, A. K., Saikia, G., & Iyer, P. K. (2010) · Journal of Materials Chemistry · doi:10.1039/c0jm03054f · Cited by 97
Recent advances in disorders of iron metabolism: mutations, mechanisms and modifiers
Roy, C. N., & Andrews, N. C. (2001) · Human Molecular Genetics · doi:10.1093/hmg/10.20.2181 · Cited by 97
Liu, Z., Xue, W., Cai, Z., Zhang, G., & Zhang, D. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm12400e · Cited by 57
Shellaiah, M., Rajan, Y. C., & Lin, H. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm00112h · Cited by 53
Self-citationA new strategy for highly selective fluorescent sensing of F− and Zn2+ with dual output modes
Bao, Y., Liu, B., Du, F., Tian, J., Wang, H., & Bai, R. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm16364k · Cited by 42
Ha‐Thi, M., Penhoat, M., Drouin, D., Blanchard-Desce, M. H., Michelet, V., & Leray, I. (2008) · Chemistry - A European Journal · doi:10.1002/chem.200800084 · Cited by 33
Cited by
Aggregation‐Induced Emission: The Whole Is More Brilliant than the Parts
Mei, J., Hong, Y., Lam, J. W. Y., Qin, A., Tang, Y., & Tang, B. Z. (2014) · Advanced Materials · doi:10.1002/adma.201401356 · Cited by 3,381
Chemically diverse small molecule fluorescent chemosensors for copper ion
Sivaraman, G., Iniya, M., Anand, T., Kotla, N. G., Sunnapu, O., Singaravadivel, S., Gulyani, A., & Chellappa, D. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.11.020 · Cited by 391
Pyrene-based aggregation-induced emission luminogens and their applications
Islam, M. M., Hu, Z., Wang, Q., Redshaw, C., & Feng, X. (2019) · Materials Chemistry Frontiers · doi:10.1039/c9qm00090a · Cited by 372
Gu, C., Huang, N., Gao, J., Xu, F., Xu, Y., & Jiang, D. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201402141 · Cited by 295
Peng, X.-L., Ruiz-Barragan, S., Li, Z.-S., Li, Q.-S., & Blancafort, L. (2016) · Journal of Materials Chemistry C · doi:10.1039/c5tc03322e · Cited by 181
Metadata
- Authors
- Shellaiah, M., Wu, Y.-H., Singh, A., Ramakrishnam Raju, M. V., & Lin, H.-C.
- Venue
- J. Mater. Chem. A
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 1
- Issue
- 4
- Pages
- 1310-1318
- ISSN
- 2050-7488 (ISSN-L)
- 2050-7496
- OpenAlex
- W2103990452
- Cited by
- 287
- References
- 44
- FWCI
- 8.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.