Ultrasound-vortex-assisted dispersive liquid–liquid microextraction coupled with gas chromatography with a nitrogen–phosphorus detector for simultaneous and rapid determination of organophosphorus pesticides and triazines in wine
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A low solvent consumption method for the sensitive determination of organophosphorus (OP) and triazine (TR) pesticides in wine samples is studied. The pesticides were extracted by ultrasound vortex assisted dispersive liquid–liquid microextraction (USVADLLME): 10 mL of sample, 1 mL of NaH2PO4 1 M, 10 μL tolidin in ethanol (internal standard) and 250 μL of C2H4Cl2 (extraction solvent) were vortexed for 30 s (any dispersive solvent was used) and the solution was kept in an ultrasound bath: the extraction was performed at 40 kHz of ultrasound frequency and 110 W for 10 min at room temperature. The determination was performed by means of gas chromatography equipped with nitrogen–phosphorus detector (GC-NPD). The enrichment factors of the analytes ranged from 210 to 232 fold and the recovery ranged from 92.0% to 103.4% (with a Relative Standard Deviation, RSD, below 7.5%). After centrifugation, the bottom phase of the chlorinated solvent was separated from the liquid hydro-alcoholic matrix, dried with anhydrous Na2SO4 and injected into the GC-NPD system. The efficiency of the liquid-phase micro-extraction process was slightly affected by the characteristics of wine samples, therefore the analytical characteristics of the method were evaluated in the linear range 0.01–10 ng mL−1. The correlation coefficients (R2) of each pesticide are above 0.963. The Limits of Detection (LOD) in GC-NPD vary between 0.007 ng mL−1 and 0.07 ng mL−1 (RSD ≤ 9.0) whereas the Limits of Quantification (LOQ) range between 0.024 ng mL−1 and 0.225 ng mL−1 (RSD ≤ 6.9); the intra-day and inter-day repeatabilities, calculated as RSD in the real matrix, are below 6.7% and 8.8%, respectively. Particular attention was devoted to comparing this methodology with other similar analytical methodologies: LODs and RSDs were studied and commented upon. It should be underlined that the good sensibility and high versatility of this methodology allow investigation of organophosphorus and triazine pesticides. At the end, the applicability of the method was demonstrated using commercial wine samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Berijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Prosen, H., & Zupančič-Kralj, L. (1999) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00109-5 · Cited by 565
Ahmadi, F., Assadi, Y., Hosseini, S. M. R. M., & Rezaee, M. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.11.017 · Cited by 325
Direct Coupling of Ionic Liquid Based Single-Drop Microextraction and GC/MS
Aguilera-Herrador, E., Lucena, R., Cárdenas, S., & Valcárcel, M. (2008) · Analytical Chemistry · doi:10.1021/ac071555g · Cited by 144
Research works printed but not linked: 42
- Gavrilescu, 2005, Eng. Life Sci., 5, 497, 10.1002/elsc.200520098 · DOI · Paper page
- T. Eleršek and M.Filipič, in Pesticides – The Impacts of Pesticides Exposure, ed. M. Stoytcheva, InTech Europe, Rijeka, Croatia, 2012, ISBN 978-953-307-531-0
- Wauchope, 1992, Rev. Environ. Contam. Toxicol., 123, 1, 10.1007/978-1-4612-2862-2_1 · DOI · Paper page
- Fatta, 2007, J. Hazard. Mater., 145, 169, 10.1016/j.jhazmat.2006.11.009 · DOI
- WHO , Organophosphorous Pesticides in the Environment – Integrated Risk Assessment, WHO, Geneva, 2001
- Avino, 2011, Aerosol Air Qual. Res., 11, 783, 10.4209/aaqr.2010.10.0085 · doi:10.4209/aaqr.2010.10.0085
- Russo, 2012, Anal. Bioanal. Chem., 404, 1517, 10.1007/s00216-012-6205-2 · doi:10.1007/s00216-012-6205-2
- R. C. Gupta , Toxicology of organophosphate and carbamate pesticides, Academic Press, Waltham, MA, 2005, ISBN: 0120885239
- Andreu, 2004, TrAC, Trends Anal. Chem., 23, 772, 10.1016/j.trac.2004.07.008 · DOI · Paper page
- Sharma, 2010, Talanta, 82, 1077, 10.1016/j.talanta.2010.06.043 · DOI · Paper page
- Liang, 2012, Water Environ. Res., 84, 1979, 10.2175/106143012X13407275695959 · DOI
- Arthur, 1990, Anal. Chem., 62, 2145, 10.1021/ac00218a019 · DOI · Paper page
- Russo, 1999, Chromatographia, 50, 446, 10.1007/BF02490740 · doi:10.1007/bf02490740
- Russo, 2000, Chromatographia, 51, 71, 10.1007/BF02490698 · doi:10.1007/bf02490698
- Russo, 2000, Chromatographia, 53, 93, 10.1007/BF02490799 · doi:10.1007/bf02490799
- Russo, 2001, Anal. Lett., 34, 1003, 10.1081/AL-100103609 · doi:10.1081/al-100103609
- Russo, 2003, J. Sep. Sci., 26, 376, 10.1002/jssc.200390047 · doi:10.1002/jssc.200390047
- Russo, 2005, J. Food Compos. Anal., 18, 617, 10.1016/j.jfca.2004.06.014 · DOI
- Russo, 2007, Chromatographia, 66, 237, 10.1365/s10337-007-0263-1 · doi:10.1365/s10337-007-0263-1
- Russo, 2009, Curr. Anal. Chem., 5, 339, 10.2174/157341109789077696 · doi:10.2174/157341109789077696
- Russo, 2009, Chromatographia, 69, 709, 10.1365/s10337-009-0961-y · doi:10.1365/s10337-009-0961-y
- Russo, 2012, Anal. Bioanal. Chem., 402, 1373, 10.1007/s00216-011-5551-9 · DOI
- Russo, 1993, Chromatographia, 35, 290, 10.1007/BF02277512 · doi:10.1007/bf02277512
- Yiantzi, 2010, Talanta, 80, 2057, 10.1016/j.talanta.2009.11.005 · DOI · Paper page
- Yang, 2011, Anal. Chim. Acta, 706, 268, 10.1016/j.aca.2011.09.001 · DOI
- Cinelli, 2006, Biotechnol. Prog., 22, 689, 10.1021/bp0504039 · doi:10.1021/bp0504039
- Cartoni, 1989, J. Chromatogr., 475, 145, 10.1016/S0021-9673(01)89670-9 · doi:10.1016/s0021-9673(01)89670-9
- Cartoni, 1991, J. Chromatogr., 552, 197, 10.1016/S0021-9673(01)95934-5 · doi:10.1016/s0021-9673(01)95934-5
- Russo, 1996, Ann. Chim., 86, 115
- Cinelli, 2014, Food Chem., 146, 181, 10.1016/j.foodchem.2013.09.064 · doi:10.1016/j.foodchem.2013.09.064
- Sathyanarayana, 2008, Pediatrics, 121, 260, 10.1542/peds.2006-3766 · DOI · Paper page
- Leong, 2012, J. Sep. Sci., 35, 688, 10.1002/jssc.201100610 · DOI
- Cinelli, 2013, Anal. Chim. Acta, 769, 72, 10.1016/j.aca.2013.01.031 · DOI
- T. U. Unger , Pesticide Synthesis Handbook, Noyes Publications, Park Ridge, NJ, 1996, ISBN: 0-8155-1401-8
- Knoll, 1985, J. Chromatogr. Sci., 23, 422, 10.1093/chromsci/23.9.422 · doi:10.1093/chromsci/23.9.422
- Jia, 2010, J. Sep. Sci., 33, 244, 10.1002/jssc.200900581 · DOI · Paper page
- Wu, 2010, Anal. Chim. Acta, 679, 56, 10.1016/j.aca.2010.09.009 · DOI
- Đurović, 2010, J. Environ. Sci. Health, Part B, 45, 626, 10.1080/03601234.2010.502416 · doi:10.1080/03601234.2010.502416
- Wu, 2012, Int. J. Environ. Anal. Chem., 93, 884, 10.1080/03067319.2012.663756 · DOI
- Wang, 2011, J. Chromatogr. Sci., 49, 689, 10.1093/chrsci/49.9.689 · DOI
- Zhong, 2012, Microchim. Acta, 178, 341, 10.1007/s00604-012-0847-9 · DOI
- Shen, 2003, J. Chromatogr., A, 985, 167, 10.1016/S0021-9673(02)01222-0 · DOI
Cited by
Application of Ultrasound in Food Science and Technology: A Perspective
Gallo, M., Ferrara, L., & Naviglio, D. (2018) · Foods · doi:10.3390/foods7100164 · Cited by 449
Application of ultrasound in combination with other technologies in food processing: A review
Singla, M., & Sit, N. (2021) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2021.105506 · Cited by 376
Ultrasound-assisted extraction of organic contaminants
Albero, B., Tadeo, J. L., & Pérez, R. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.07.007 · Cited by 120
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
“Some authors combine VA and UA as external energies to improve the effect of the disperser solvent (395, 512, 563, 567, 767, 808, 845, 1045) or to avoid its use (667, 707).”
BackgroundPirsaheb, M., & Fattahi, N. (2018) · RSC Advances · doi:10.1039/c8ra00912k · Cited by 83
Metadata
- Authors
- Cinelli, G., Avino, P., Notardonato, I., & Russo, M. V.
- Venue
- Anal. Methods
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 6
- Issue
- 3
- Pages
- 782-790
- ISSN
- 1759-9660 (ISSN-L)
- 1759-9679
- OpenAlex
- W2045843794
- Cited by
- 64
- References
- 5
- FWCI
- 5.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound-vortex-assisted dispersive liquid–liquid microextraction coupled with gas chromatography with a nitrogen–phosphorus detector for simultaneous and rapid determination of organophosphorus pesticides and triazines in wine. https://app.cochat.ai/papers/10.1039/c3ay41641k
- The paper
- Cinelli, G., Avino, P., Notardonato, I., & Russo, M. V. (2014). Ultrasound-vortex-assisted dispersive liquid–liquid microextraction coupled with gas chromatography with a nitrogen–phosphorus detector for simultaneous and rapid determination of organophosphorus pesticides and triazines in wine. Anal. Methods. https://doi.org/10.1039/c3ay41641k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.