The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Label-free biodetection using a smartphone
Abstract
Utilizing its integrated camera as a spectrometer, we demonstrate the use of a smartphone as the detection instrument for a label-free photonic crystal biosensor. A custom-designed cradle holds the smartphone in fixed alignment with optical components, allowing for accurate and repeatable measurements of shifts in the resonant wavelength of the sensor. Externally provided broadband light incident upon an entrance pinhole is subsequently collimated and linearly polarized before passing through the biosensor, which resonantly reflects only a narrow band of wavelengths. A diffraction grating spreads the remaining wavelengths over the camera's pixels to display a high resolution transmission spectrum. The photonic crystal biosensor is fabricated on a plastic substrate and attached to a standard glass microscope slide that can easily be removed and replaced within the optical path. A custom software app was developed to convert the camera images into the photonic crystal transmission spectrum in the visible wavelength range, including curve-fitting analysis that computes the photonic crystal resonant wavelength with 0.009 nm accuracy. We demonstrate the functionality of the system through detection of an immobilized protein monolayer, and selective detection of concentration-dependent antibody binding to a functionalized photonic crystal. We envision the capability for an inexpensive, handheld biosensor instrument with web connectivity to enable point-of-care sensing in environments that have not been practical previously.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Colloidal Au-Enhanced Surface Plasmon Resonance for Ultrasensitive Detection of DNA Hybridization
He, L., Musick, M. D., Nicewarner, S. R., Salinas, F. G., Benkovic, S. J., Natan, M. J., & Keating, C. D. (2000) · Journal of the American Chemical Society · doi:10.1021/ja001215b · Cited by 932
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
Colloidal Au-Enhanced Surface Plasmon Resonance Immunosensing
Lyon, L. A., Musick, M. D., & Natan, M. J. (1998) · Analytical Chemistry · doi:10.1021/ac9809940 · Cited by 618
ELISA and Multiplex Technologies for Cytokine Measurement in Inflammation and Aging Research
Leng, S. X., McElhaney, J. E., Walston, J. D., Xie, D., Fedarko, N. S., & Kuchel, G. A. (2008) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/63.8.879 · Cited by 516
Lensfree microscopy on a cellphone
Tseng, D., Mudanyali, O., Oztoprak, C., Isikman, S. O., Sencan, I., Yaglidere, O., & Ozcan, A. (2010) · Lab on a Chip · doi:10.1039/c003477k · Cited by 480
Surface plasmon resonance based biosensor technique: A review
Guo, X. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201200015 · Cited by 436
Integrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Optofluidic Fluorescent Imaging Cytometry on a Cell Phone
Zhu, H., Mavandadi, S., Coskun, A. F., Yaglidere, O., & Ozcan, A. (2011) · Analytical Chemistry · doi:10.1021/ac201587a · Cited by 390
Cell-Phone-Based Platform for Biomedical Device Development and Education Applications
Smith, Z. J., Chu, K., Espenson, A. R., Rahimzadeh, M., Gryshuk, A., Molinaro, M., Dwyre, D. M., Lane, S., Matthews, D., & Wachsmann-Hogiu, S. (2011) · PLoS ONE · doi:10.1371/journal.pone.0017150 · Cited by 339
Quantum dot enabled detection of Escherichia coli using a cell-phone
Zhu, H., Sikora, U., & Ozcan, A. (2012) · The Analyst · doi:10.1039/c2an35071h · Cited by 277
Label-Free Detection of DNA Hybridization Using Surface Enhanced Raman Spectroscopy
Barhoumi, A., & Halas, N. J. (2010) · Journal of the American Chemical Society · doi:10.1021/ja105678z · Cited by 261
Label‐free detection techniques for protein microarrays: Prospects, merits and challenges
Ray, S., Mehta, G., & Srivastava, S. (2010) · PROTEOMICS · doi:10.1002/pmic.200900458 · Cited by 224
Soelberg, S. D., Stevens, R. C., Limaye, A. P., & Furlong, C. E. (2009) · Analytical Chemistry · doi:10.1021/ac900007c · Cited by 174
Photonic crystal biosensors towards on‐chip integration
Threm, D., Nazirizadeh, Y., & Gerken, M. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201200039 · Cited by 113
Chan, L. L., Gosangari, S. L., Watkin, K. L., & Cunningham, B. T. (2007) · APOPTOSIS · doi:10.1007/s10495-006-0031-y · Cited by 110
Self-citationChoi, C. J., & Cunningham, B. T. (2007) · Lab on a Chip · doi:10.1039/b618584c · Cited by 98
Self-citationA comparison of ELISA and flow microsphere-based assays for quantification of immunoglobulins
Dasso, J. F., Lee, J., Bach, H., & Mage, R. G. (2002) · Journal of Immunological Methods · doi:10.1016/s0022-1759(02)00028-5 · Cited by 84
Choi, C. J., & Cunningham, B. T. (2006) · Lab on a Chip · doi:10.1039/b603514k · Cited by 77
Self-citationLabel free biosensor incorporating a replica-molded, vertically emitting distributed feedback laser
Lu, M., Choi, S., Wagner, C. J., Eden, J. G., & Cunningham, B. T. (2008) · Applied Physics Letters · doi:10.1063/1.2913007 · Cited by 75
Self-citationWu, Y., Hruszkewycz, A. M., Delgado, R. M., Yang, A. S., Vortmeyer, A. O., Moon, Y.-W., Weil, R. J., Zhuang, Z., & Remaley, A. T. (2000) · Clinica Chimica Acta · doi:10.1016/s0009-8981(99)00238-7 · Cited by 72
A detection instrument for enhanced-fluorescence and label-free imaging on photonic crystal surfaces
Block, I. D., Mathias, P. C., Ganesh, N., Jones, S. I., Dorvel, B. R., Chaudhery, V., Vodkin, L. O., Bashir, R., & Cunningham, B. T. (2009) · Optics Express · doi:10.1364/oe.17.013222 · Cited by 65
Self-citationSurface plasmon resonance biosensor for direct detection of antibodies against human growth hormone
Kausaite‐Minkstimiene, A., Ramanavičienė, A., & Ramanavičius, A. (2009) · The Analyst · doi:10.1039/b907315a · Cited by 57
Cited by
Optical biosensors: an exhaustive and comprehensive review
Chen, C., & Wang, J. (2020) · The Analyst · doi:10.1039/c9an01998g · Cited by 781
Intelligent Food Packaging: A Review of Smart Sensing Technologies for Monitoring Food Quality
Yousefi, H., Su, H.-M., Imani, S. M., Alkhaldi, K., M. Filipe, C. D., & Didar, T. F. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00440 · Cited by 682
Biosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 647
Crocombe, R. A. (2018) · Applied Spectroscopy · doi:10.1177/0003702818809719 · Cited by 532
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520
Metadata
- Authors
- Gallegos, D., Long, K. D., Yu, H., Clark, P. P., Lin, Y., George, S., Nath, P., & Cunningham, B. T.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 11
- Pages
- 2124
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2093843230
- Cited by
- 312
- References
- 23
- FWCI
- 20.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.