Artificial microfluidic skin for in vitro perspiration simulation and testing
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
To expedite development of any skin wearable material, product, or device, an artificial perspiration (sweat) simulator can provide improved ease, cost, control, flexibility, and reproducibility in comparison to human or animal tests. Reported here is a human perspiration mimicking device including microreplicated skin-texture. A bottom 0.2 μm track etched polycarbonate membrane layer provides flow-rate control while a top photo-curable layer provides skin-like features such as sweat pore density, hydrophobicity, and wetting hysteresis. Key capabilities of this sweat simulator include: constant 'sweat' rate density without bubble-point variation even down to ~1 L h(-1) m(-2); replication of the 2 pores mm(-2) pore-density and the ~50 μm texture of human skin; simple gravity-fed flow control; low-cost and disposable construction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BIOTEX—Biosensing Textiles for Personalised Healthcare Management
Coyle, S., Lau, K.-T., Moyna, N., O'Gorman, D., Diamond, D., Di Francesco, F., Costanzo, D., Salvo, P., Trivella, M. G., De Rossi, D. E., et al. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2038484 · Cited by 330
Cizza, G., Marques, A. H., Eskandari, F., Christie, I. C., Torvik, S., Silverman, M. N., Phillips, T. M., & Sternberg, E. M. (2008) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.05.035 · Cited by 208
Sweat Rate and Electrolyte Concentration in Swimmers, Runners, and Nonathletes
Henkin, S. D., Sehl, P. L., & Meyer, F. (2010) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.5.3.359 · Cited by 28
Cited by
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Self-citationSkin tissue regeneration for burn injury
Shpichka, A., Butnaru, D., Bezrukov, E. A., Sukhanov, R. B., Atala, A., Burdukovskii, V., Zhang, Y., & Timashev, P. (2019) · Stem Cell Research & Therapy · doi:10.1186/s13287-019-1203-3 · Cited by 417
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294
Self-citationMaterials used to simulate physical properties of human skin
Dąbrowska, A. K., Rotaru, G. ‐., Derler, S., Spano, F., Camenzind, M., Annaheim, S., Stämpfli, R., Schmid, M., & Rossi, R. M. (2016) · Skin Research and Technology · doi:10.1111/srt.12235 · Cited by 259
Metadata
- Authors
- Hou, L., Hagen, J., Wang, X., Papautsky, I., Naik, R., Kelley-Loughnane, N., & Heikenfeld, J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 10
- Pages
- 1868
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2140212893
- Cited by
- 55
- References
- 3
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artificial microfluidic skin for in vitro perspiration simulation and testing. https://app.cochat.ai/papers/10.1039/c3lc41231h
- The paper
- Hou, L., Hagen, J., Wang, X., Papautsky, I., Naik, R., Kelley-Loughnane, N., & Heikenfeld, J. (2013). Artificial microfluidic skin for in vitro perspiration simulation and testing. Lab on a Chip. https://doi.org/10.1039/c3lc41231h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.