Three-dimensional co-cultures of human endothelial cells and embryonic stem cell-derived pericytes inside a microfluidic device
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Organs-on-chips are microengineered in vitro tissue structures that can be used as platforms for physiological and pathological research. They provide tissue-like microenvironments in which different cell types can be co-cultured in a controlled manner to create synthetic organ mimics. Blood vessels are an integral part of all tissues in the human body. Development of vascular structures is therefore an important research topic for advancing the field of organs-on-chips since generated tissues will require a blood or nutrient supply. Here, we have engineered three-dimensional constructs of vascular tissue inside microchannels by injecting a mixture of human umbilical vein endothelial cells, human embryonic stem cell-derived pericytes (the precursors of vascular smooth muscle cells) and rat tail collagen I into a polydimethylsiloxane microfluidic channel with dimensions 500 μm × 120 μm × 1 cm (w × h × l). Over the course of 12 h, the cells organized themselves into a single long tube resembling a blood vessel that followed the contours of the channel. Detailed examination of tube morphology by confocal microscopy revealed a mature endothelial monolayer with complete PECAM-1 staining at cell-cell contacts and pericytes incorporated inside the tubular structures. We also demonstrated that tube formation was disrupted in the presence of a neutralizing antibody against transforming growth factor-beta (TGF-β). The TGF-β signaling pathway is essential for normal vascular development; deletion of any of its components in mouse development results in defective vasculogenesis and angiogenesis and mutations in humans have been linked to multiple vascular genetic diseases. In the engineered microvessels, inhibition of TGF-β signaling resulted in tubes with smaller diameters and higher tortuosity, highly reminiscent of the abnormal vessels observed in patients with one particular vascular disease known as hereditary hemorrhagic telangiectasia (HHT). In summary, we have developed microengineered three-dimensional vascular structures that can be used as a model to test the effects of drugs and study the interaction between different human vascular cell types. In the future, the model may be integrated into larger tissue constructs to advance the development of organs-on-chips.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A perivascular origin for mesenchymal stem cells in multiple human organs
Crisan, M., Yap, S., Casteilla, L., Chen, C.-W., Corselli, M., Park, T. S., Andriolo, G., Sun, B., Zheng, B., Zhang, L., et al. (2008) · Cell Stem Cell · doi:10.1016/j.stem.2008.07.003 · Cited by 3,991
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Cited by
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Organs-on-chips: into the next decade
Low, L. A., Mummery, C., Berridge, B. R., Austin, C. P., & Tagle, D. A. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-020-0079-3 · Cited by 1,029
Self-citationCo-culture systems and technologies: taking synthetic biology to the next level
Goers, L., Freemont, P., & Polizzi, K. M. (2014) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.0065 · Cited by 630
Small molecule absorption by PDMS in the context of drug response bioassays
van Meer, B. J., de Vries, H., Firth, K. S. A., van Weerd, J., Tertoolen, L. G. J., Karperien, H. B. J., Jonkheijm, P., Denning, C., IJzerman, A. P., & Mummery, C. L. (2017) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2016.11.062 · Cited by 502
Self-citationHerland, A., van der Meer, A. D., FitzGerald, E. A., Park, T.-E., Sleeboom, J. J. F., & Ingber, D. E. (2016) · PLOS ONE · doi:10.1371/journal.pone.0150360 · Cited by 476
Self-citationHuman pluripotent stem cell culture: considerations for maintenance, expansion, and therapeutics
Chen, K. G., Mallon, B. S., McKay, R. D. G., & Robey, P. G. (2014) · Cell Stem Cell · doi:10.1016/j.stem.2013.12.005 · Cited by 358
Wevers, N. R., Kasi, D. G., Gray, T., Wilschut, K. J., Smith, B., van Vught, R., Shimizu, F., Sano, Y., Kanda, T., Marsh, G., et al. (2018) · Fluids and Barriers of the CNS · doi:10.1186/s12987-018-0108-3 · Cited by 353
Lian, X., Bao, X., Al-Ahmad, A., Liu, J., Wu, Y., Dong, W., Dunn, K. K., Shusta, E. V., & Palecek, S. P. (2014) · Stem Cell Reports · doi:10.1016/j.stemcr.2014.09.005 · Cited by 321
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Recent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277
Personalised organs-on-chips: functional testing for precision medicine
van den Berg, A., Mummery, C. L., Passier, R., & van der Meer, A. D. (2019) · Lab on a Chip · doi:10.1039/c8lc00827b · Cited by 270
Self-citationCanfield, S. G., Stebbins, M. J., Morales, B. S., Asai, S. W., Vatine, G. D., Svendsen, C. N., Palecek, S. P., & Shusta, E. V. (2017) · Journal of Neurochemistry · doi:10.1111/jnc.13923 · Cited by 250
Costa, P. F., Albers, H. J., Linssen, J. E. A., Middelkamp, H. H. T., van der Hout, L., Passier, R., van den Berg, A., Malda, J., & van der Meer, A. D. (2017) · Lab on a Chip · doi:10.1039/c7lc00202e · Cited by 226
Surface Modification Techniques for Endothelial Cell Seeding in PDMS Microfluidic Devices
Akther, F., Yakob, S. B., Nguyen, N.-T., & Ta, H. T. (2020) · Biosensors · doi:10.3390/bios10110182 · Cited by 182
Engineering of a Biomimetic Pericyte-Covered 3D Microvascular Network
Kim, J., Chung, M., Kim, S., Jo, D. H., Kim, J. H., & Jeon, N. L. (2015) · PLOS ONE · doi:10.1371/journal.pone.0133880 · Cited by 160
Complex Tissue and Disease Modeling using hiPSCs
Passier, R., Orlova, V., & Mummery, C. (2016) · Cell Stem Cell · doi:10.1016/j.stem.2016.02.011 · Cited by 142
“Other vascular pathologies have also been indicated to precede AD (Kanekiyo et al., 2014; Verghese et al., 2011).”
BackgroundSelf-citationWang, X., Sun, Q., & Pei, J. (2018) · Micromachines · doi:10.3390/mi9100493 · Cited by 106
Chang, S.-Y., Voellinger, J. L., Van Ness, K. P., Chapron, B., Shaffer, R. M., Neumann, T., White, C. C., Kavanagh, T. J., Kelly, E. J., & Eaton, D. L. (2017) · Toxicology in Vitro · doi:10.1016/j.tiv.2017.01.007 · Cited by 49
Toward improved in vitro models of human cancer
Ayuso, J. M., Park, K.-Y., Virumbrales-Muñoz, M., & Beebe, D. J. (2021) · APL Bioengineering · doi:10.1063/5.0026857 · Cited by 40
Microfluidic Systems for Neural Cell Studies
Babaliari, E., Ranella, A., & Stratakis, E. (2023) · Bioengineering · doi:10.3390/bioengineering10080902 · Cited by 13
Pericytes in Tissue Engineering
Çelebi-Saltik, B. (2018) · Advances in Experimental Medicine and Biology · doi:10.1007/978-3-030-02601-1_10 · Cited by 9
Metadata
- Authors
- van der Meer, A. D., Orlova, V. V., ten Dijke, P., van den Berg, A., & Mummery, C. L.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 18
- Pages
- 3562
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2121973883
- Cited by
- 150
- References
- 2
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.