Isolation and mutational analysis of circulating tumor cells from lung cancer patients with magnetic sifters and biochips
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Detection and characterization of circulating tumor cells (CTCs) may reveal insights into the diagnosis and treatment of malignant disease. Technologies for isolating CTCs developed thus far suffer from one or more limitations, such as low throughput, inability to release captured cells, and reliance on expensive instrumentation for enrichment or subsequent characterization. We report a continuing development of a magnetic separation device, the magnetic sifter, which is a miniature microfluidic chip with a dense array of magnetic pores. It offers high efficiency capture of tumor cells, labeled with magnetic nanoparticles, from whole blood with high throughput and efficient release of captured cells. For subsequent characterization of CTCs, an assay, using a protein chip with giant magnetoresistive nanosensors, has been implemented for mutational analysis of CTCs enriched with the magnetic sifter. The use of these magnetic technologies, which are separate devices, may lead the way to routine preparation and characterization of "liquid biopsies" from cancer patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A large magnetic field gradient created by the permanent magnet was required to enhance the separation efficiency of the magnetic cell separation.33”
From Dynamic Halbach array magnet integrated microfluidic system for the continuous-flow separation of rare tumor cells (2019) · cites this paper as [33]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Circulating Tumor Cells, Disease Progression, and Survival in Metastatic Breast Cancer
Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Matera, J., Miller, M. C., Reuben, J. M., Doyle, G. V., Allard, W. J., Terstappen, L. W. M. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040766 · Cited by 4,593
EGFR Mutation and Resistance of Non–Small-Cell Lung Cancer to Gefitinib
Kobayashi, S., Boggon, T. J., Dayaram, T., Jänne, P. A., Kocher, O., Meyerson, M., Johnson, B. E., Eck, M. J., Tenen, D. G., & Halmos, B. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa044238 · Cited by 3,964
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Pao, W., Miller, V. A., Politi, K. A., Riely, G. J., Somwar, R., Zakowski, M. F., Kris, M. G., & Varmus, H. (2005) · PLoS Medicine · doi:10.1371/journal.pmed.0020073 · Cited by 3,527
Circulating Breast Tumor Cells Exhibit Dynamic Changes in Epithelial and Mesenchymal Composition
Yu, M., Bardia, A., Wittner, B. S., Stott, S. L., Smas, M. E., Ting, D. T., Isakoff, S. J., Ciciliano, J. C., Wells, M. N., Shah, A. M., et al. (2013) · Science · doi:10.1126/science.1228522 · Cited by 2,476
High gradient magnetic cell separation with MACS
Miltenyi, S., Müller, W., Weichel, W., & Radbruch, A. (1990) · Cytometry · doi:10.1002/cyto.990110203 · Cited by 1,681
Isolation of circulating tumor cells using a microvortex-generating herringbone-chip
Stott, S. L., Hsu, C.-H., Tsukrov, D. I., Yu, M., Miyamoto, D. T., Waltman, B. A., Rothenberg, S. M., Shah, A. M., Smas, M. E., Korir, G. K., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1012539107 · Cited by 1,634
Detection of Mutations in EGFR in Circulating Lung-Cancer Cells
Maheswaran, S., Sequist, L. V., Nagrath, S., Ulkus, L., Brannigan, B., Collura, C. V., Inserra, E., Diederichs, S., Iafrate, A. J., Bell, D. W., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800668 · Cited by 1,617
The physics of cancer: the role of physical interactions and mechanical forces in metastasis
Wirtz, D., Konstantopoulos, K., & Searson, P. C. (2011) · Nature Reviews Cancer · doi:10.1038/nrc3080 · Cited by 1,344
Circulating Tumor Cells: A Novel Prognostic Factor for Newly Diagnosed Metastatic Breast Cancer
Cristofanilli, M., Hayes, D. F., Budd, G. T., Ellis, M. J., Stopeck, A., Reuben, J. M., Doyle, G. V., Matera, J., Allard, W. J., Miller, M. C., et al. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2005.08.140 · Cited by 1,135
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Circulating tumor cell technologies
Ferreira, M. M., Ramani, V. C., & Jeffrey, S. S. (2016) · Molecular Oncology · doi:10.1016/j.molonc.2016.01.007 · Cited by 511
Self-citationIgnatiadis, M., Lee, M., & Jeffrey, S. S. (2015) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-14-1190 · Cited by 355
“Magnetic sifter Flow-through fluidic array with magnetic pore structure for efficient separation of cells labeled with magnetic nanoparticles Magnetically labeled target cells captured at the pore edges can then be released for culture or lysed and placed on a biosensor chip for mutational analysis No (141)”
BackgroundSelf-citationRare cell isolation and analysis in microfluidics
Chen, Y., Li, P., Huang, P.-H., Xie, Y., Mai, J. D., Wang, L., Nguyen, N.-T., & Huang, T. J. (2014) · Lab on a Chip · doi:10.1039/c3lc90136j · Cited by 307
Magnetoresistive Sensor Development Roadmap (Non-Recording Applications)
Zheng, C., Zhu, K., Cardoso de Freitas, S., Chang, J.-Y., Davies, J. E., Eames, P., Freitas, P. P., Kazakova, O., Kim, C., Leung, C.-W., et al. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2896036 · Cited by 268
“In 2014, the detection and characterization of circulating tumor cells (CTCs) were conducted with a GMR-based biochip and CTCs were detected in the blood samples from lung cancer patients [54].”
MethodSelf-citationCombining Machine Learning and Nanofluidic Technology To Diagnose Pancreatic Cancer Using Exosomes
Ko, J., Bhagwat, N., Yee, S. S., Ortiz, N., Sahmoud, A., Black, T., Aiello, N. M., McKenzie, L., O’Hara, M., Redlinger, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b05503 · Cited by 249
Emerging Role of Nanomaterials in Circulating Tumor Cell Isolation and Analysis
Yoon, H. J., Kozminsky, M., & Nagrath, S. (2014) · ACS Nano · doi:10.1021/nn5004277 · Cited by 245
“Immunomagnetic labeling was combined with a magnetic sifter for high-throughput (10 mL/h) cell capture and subsequent release.(80) In the presence of a magnet, samples prelabeled with anti-EpCAMconjugated MNPs were drawn to the edge of the 40 μm pores in a silicon nitride membrane that was coated with an 80% nickel an…”
MethodOrgan-on-chip models of cancer metastasis for future personalized medicine: From chip to the patient
Caballero, D., Kaushik, S., Correlo, V. M., Oliveira, J. M., Reis, R. L., & Kundu, S. C. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.005 · Cited by 221
Harouaka, R., Kang, Z., Zheng, S.-Y., & Cao, L. (2014) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2013.10.004 · Cited by 195
Jackson, J. M., Witek, M. A., Kamande, J. W., & Soper, S. A. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00016b · Cited by 172
Large‐Scale Synthesis and Medical Applications of Uniform‐Sized Metal Oxide Nanoparticles
Kwon, H. J., Shin, K., Soh, M., Chang, H., Kim, J., Lee, J., Ko, G., Kim, B. H., Kim, D., & Hyeon, T. (2018) · Advanced Materials · doi:10.1002/adma.201704290 · Cited by 159
Microfluidic techniques for high throughput single cell analysis
Reece, A. E., Xia, B., Jiang, Z., Noren, B. E., McBride, R., & Oakey, J. S. (2016) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2016.02.015 · Cited by 162
“Among many passive particle separation motifs, high throughput hydrodynamic sorting includes size-exclusion filtration [31], cross-flow [32], hydrophoretic [33] and”
Praharaj, P. P., Bhutia, S. K., Nagrath, S., Bitting, R. L., & Deep, G. (2018) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2017.12.005 · Cited by 147
“These chips sieve samples by vertical flow centrifugation and reportedly allow efficient capture of CTCs followed by high-throughput release [49].”
Nanosensors and their applications in early diagnosis of cancer
Khazaei, M., Hosseini, M. S., Haghighi, A. M., & Misaghi, M. (2023) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2023.100569 · Cited by 137
Thege, F. I., Lannin, T. B., Saha, T. N., Tsai, S. J., Kochman, M. L., Hollingsworth, M. A., Rhim, A. D., & Kirby, B. J. (2014) · Lab on a Chip · doi:10.1039/c4lc00041b · Cited by 141
An intravascular magnetic wire for the high-throughput retrieval of circulating tumour cells in vivo
Vermesh, O., Aalipour, A., Ge, T. J., Sáenz, Y., Guo, Y., Alam, I. S., Park, S.-M., Adelson, C. N., Mitsutake, Y., Vilches-Moure, J. G., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0257-3 · Cited by 128
Self-citationBasic Principles and Recent Advances in Magnetic Cell Separation
Frénéa‐Robin, M., & Marchalot, J. (2022) · Magnetochemistry · doi:10.3390/magnetochemistry8010011 · Cited by 133
NanoVelcro rare-cell assays for detection and characterization of circulating tumor cells
Jan, Y. J., Chen, J., Zhu, Y., Lu, Y., Chen, S. H., Chung, H., Smalley, M. D., Huang, Y.-W., Dong, J., Chen, L.-C., et al. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.03.006 · Cited by 119
“MagSweeper[25], magnetic sifters[26], AdnaGen/Qiagen[27], IsoFlux[28], VerIFAST[29] and Cynvenio[30], were developed to improve the speed, efficiency, and cost of CTC detection and ACCEPTED MANUSCRIPT”
MethodMagnetic Force-Based Microfluidic Techniques for Cellular and Tissue Bioengineering
Yaman, S., Anıl-İnevi, M., Özçivici, E., & Tekin, H. C. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00192 · Cited by 120
“Another design included a magnetic sifter-based microstructure having arrays of 40 × 40μm pores in a honey comb format to separate cancer cells (Earhart et al., 2014).”
MethodThe Prognostic Role of Circulating Tumor Cells (CTCs) in Lung Cancer
Kapeleris, J., Kulasinghe, A., Warkiani, M. E., Vela, I., Kenny, L., O'Byrne, K. J., & Punyadeera, C. (2018) · Frontiers in Oncology · doi:10.3389/fonc.2018.00311 · Cited by 123
Dong, J., Chen, J., Smalley, M. D., Zhao, M., Ke, Z., Zhu, Y., & Tseng, H. (2019) · Advanced Materials · doi:10.1002/adma.201903663 · Cited by 111
Wu, J., Wei, X., Gan, J., Huang, L., Shen, T., Lou, J., Liu, B., Zhang, J. X. J., & Qian, K. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504184 · Cited by 107
Bharath, G., Sabri, M. A., Hai, A., BANAT, F. A., & Haija, M. A. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15030868 · Cited by 118
Molecular profiling of single circulating tumor cells from lung cancer patients
Park, S.-M., Wong, D. J., Ooi, C. C., Kurtz, D. M., Vermesh, O., Aalipour, A., Suh, S., Pian, K. L., Chabon, J. J., Lee, S. H., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1608461113 · Cited by 104
“We thank Dr. Pragya Tripathi for assistance with preparation of patient blood samples, Dr. Ivan K. Dimov and Prof. Aram J. Chung for helpful discussions, and Dr. Christopher M. Earhart for MagSifter fabrication expertise.”
BackgroundMethodInfluentialSelf-citationDianat‐Moghadam, H., Azizi, M., Eslami‐S, Z., Cortés‐Hernández, L. E., Heidarifard, M., Nouri, M., & Alix‐Panabières, C. (2020) · Cancers · doi:10.3390/cancers12040867 · Cited by 106
“This problem has been solved by designing smaller microfluidic chips with magnetic pores and using vertical flow centrifugation for the release of intact CTCs [105].”
MethodLiquid Biopsy in Lung Cancer: Clinical Applications of Circulating Biomarkers (CTCs and ctDNA)
Lim, M., Kim, C., Sunkara, V., Kim, M., & Cho, Y. (2018) · Micromachines · doi:10.3390/mi9030100 · Cited by 107
“5 cm PDMS chip) capable of single-cell isolation and retrieval was developed to improve purity [40]; (D) A nanowell array filled with CTCs magnetically captured by a dense array of magnetic pores (MagSifter) were used for multigene expression profiling from individual CTCs (Upper scale bar: 200 μm, lower scale bar: 50…”
MethodCirculating tumor cell detection using a parallel flow micro-aperture chip system
Chang, C.-L., Huang, W., Jalal, S. I., Chan, B., Mahmood, A., Shahda, S., O’Neil, B. H., Matei, D. E., & Savran, C. A. (2015) · Lab on a Chip · doi:10.1039/c5lc00100e · Cited by 97
Chou, W.-P., Wang, H., Chang, J.-H., Chiu, T.-K., Hsieh, C., Liao, C., & Wu, M. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.10.075 · Cited by 93
3D printed microfluidic devices for circulating tumor cells (CTCs) isolation
Chen, J., Liu, C., Wang, X., Sweet, E. C., Liu, N., Gong, X., & Lin, L. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111900 · Cited by 100
Xu, G., Tan, Y., Xu, T., Yin, D., Wang, M., Shen, M., Chen, X., Shi, X., & Zhu, X. (2017) · Biomaterials Science · doi:10.1039/c6bm00933f · Cited by 90
Huang, Q., Wang, Y., Chen, X., Wang, Y., Li, Z., Du, S., Wang, L., & Chen, S. (2017) · Nanotheranostics · doi:10.7150/ntno.22091 · Cited by 96
“(Figure 5B) recently developed a magnetic sifter for CTC capture and release with high-throughput [99].”
BackgroundMethodYang, L., Patel, K. D., Rathnam, C., Thangam, R., Hou, Y., Kang, H., & Lee, K. (2022) · Small · doi:10.1002/smll.202104783 · Cited by 81
Nanotechnology for Enrichment and Detection of Circulating Tumor Cells
Bhana, S., Wang, Y., & Huang, X. (2015) · Nanomedicine · doi:10.2217/nnm.15.32 · Cited by 89
Circulating Tumor Cell Isolation and Analysis
Zhang, J., Chen, K., & Fan, Z. H. (2016) · Advances in clinical chemistry · doi:10.1016/bs.acc.2016.03.003 · Cited by 100
“As a result, several sophisticated systems, including VerIFAST [56], magnetic sifter [57], MagSweeper [88], and IsoFlux [89], have been developed to further improve the detection speed and efficiency.”
MethodBench-To-Bedside Translation of Magnetic Nanoparticles
Singh, D., McMillan, J. M., Kabanov, A. V., Sokolsky-Papkov, M., & Gendelman, H. E. (2014) · Nanomedicine · doi:10.2217/nnm.14.5 · Cited by 75
Microfluidic-based cancer cell separation using active and passive mechanisms
Liang, W., Liu, J., Yang, X., Zhang, Q., Yang, W., Zhang, H., & Liu, L. (2020) · Microfluidics and Nanofluidics · doi:10.1007/s10404-020-2331-x · Cited by 78
Tang, W., Jiang, D., Li, Z., Zhu, L., Shi, J., Yang, J., & Xiang, N. (2018) · Electrophoresis · doi:10.1002/elps.201800361 · Cited by 79
Opportunities and Challenges for Pancreatic Circulating Tumor Cells
Nagrath, S., Jack, R. M., Sahai, V., & Simeone, D. M. (2016) · Gastroenterology · doi:10.1053/j.gastro.2016.05.052 · Cited by 75
Gu, Y., Ju, C., Li, Y., Shang, Z., Wu, Y., Jia, Y., & Niu, Y. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.10.070 · Cited by 73
Applications of magnetic nanoparticles in biomedical separation and purification
Yıldız, İ. (2015) · Nanotechnology Reviews · doi:10.1515/ntrev-2015-0012 · Cited by 77
Single-cell assay on microfluidic devices
Huang, Q., Mao, S., Khan, M., & Lin, J. (2019) · The Analyst · doi:10.1039/c8an01079j · Cited by 72
Label-free ferrohydrodynamic cell separation of circulating tumor cells
Zhao, W., Cheng, R., Jenkins, B. D., Zhu, Τ., Okonkwo, N. E., Jones, C. E., Davis, M. B., Kavuri, S., Hao, Z., Schroeder, C., et al. (2017) · Lab on a Chip · doi:10.1039/c7lc00680b · Cited by 73
Magnetically driven microfluidics for isolation of circulating tumor cells
Luo, L., & He, Y. (2020) · Cancer Medicine · doi:10.1002/cam4.3077 · Cited by 72
Circulating tumor cell profiling for precision oncology
Labib, M., & Kelley, S. O. (2021) · Molecular Oncology · doi:10.1002/1878-0261.12901 · Cited by 73
Circulating tumor cells as a response monitor in stage IV non-small cell lung cancer
Shishido, S. N., Carlsson, A., Nieva, J., Bethel, K., Hicks, J. B., Bazhenova, L., & Kuhn, P. (2019) · Journal of Translational Medicine · doi:10.1186/s12967-019-2035-8 · Cited by 64
Chen, J., Zhu, Y., Lu, Y., Hodara, E., Hou, S., Agopian, V. G., Tomlinson, J. S., Posadas, E. M., & Tseng, H. (2016) · Theranostics · doi:10.7150/thno.15359 · Cited by 64
“, MagSweeper[24], IsoFlux[25], Cynvenio,[26] magnetic sifters,[27] VerIFAST[28] and AdnaGen/Qiagen[29]) have been developed to further improve detection speed and efficiency.”
Tadimety, A., Closson, A. B., Li, C., Song, Y., Shen, T., & Zhang, J. X. J. (2018) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2018.1425976 · Cited by 62
“Biomarker-based capture Whole blood Lung cancer Immunomagnetic “Magnetic Sifter” EGFR mutation, on-chip þþ [60]”
BackgroundMethodCirculating Tumor Cells and Implications of the Epithelial-to-Mesenchymal Transition
Lowes, L. E., & Allan, A. L. (2017) · Advances in clinical chemistry · doi:10.1016/bs.acc.2017.10.004 · Cited by 63
Yu, X., Wu, N., Chen, F., Wei, J., & Zhao, Y. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.03.027 · Cited by 52
Magnetic activated cell sorting (MACS) pipette tip for immunomagnetic bacteria separation
Oh, S., Jung, S. H., Seo, H., Min, M.-K., Kim, B., Hahn, Y. K., Kang, J. H., & Choi, S. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.05.146 · Cited by 49
Microchip-based detection of magnetically labeled cancer biomarkers
Muluneh, M., & Issadore, D. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.09.013 · Cited by 52
“combined this GMR detection scheme with a magnetic isolation technique, to detect and profile circulating tumor cells (CTCs) in whole blood [64].”
MethodMagnetic Particles for CTC Enrichment
Liu, P., Jonkheijm, P., Terstappen, L. W. M. M., & Stevens, M. (2020) · Cancers · doi:10.3390/cancers12123525 · Cited by 50
Current and future applications of liquid biopsy in non-small-cell lung cancer—a narrative review
Tomasik, B., Skrzypski, M. T., Bieńkowski, M., Dziadziuszko, R., & Jassem, J. (2023) · Translational Lung Cancer Research · doi:10.21037/tlcr-22-742 · Cited by 56
“As mentioned earlier, the number of CTCs generally correlates with the NSCLC burden, and the detection rate varies greatly from 15% to 100% (98-110).”
BackgroundBiosensors for the Detection of Circulating Tumour Cells
Costa, C., Abal, M., López‐López, R., & Muinelo‐Romay, L. (2014) · Sensors · doi:10.3390/s140304856 · Cited by 45
“Recently, an immune-filtration approach has also been developed and isolation of CTCs from lung cancer patients has been shown [29].”
BackgroundGalvão, W. S., Neto, D. M. A., Freire, R. M., & Fechine, P. B. A. (2015) · Diffusion and defect data, solid state data. Part B, Solid state phenomena/Solid state phenomena · doi:10.4028/www.scientific.net/ssp.241.139 · Cited by 52
“[159] reported a continuous development of a magnetic separation device (a miniature microfluidic chip with a dense array of magnetic pores) for capture of the tumor cells.”
BackgroundMethods for Single-Cell Isolation and Preparation
Pensold, D., & Zimmer‐Bensch, G. (2020) · Advances in experimental medicine and biology · doi:10.1007/978-981-15-4494-1_2 · Cited by 49
Lung on a Chip for Drug Screening and Design
Kızılkurtlu, A. A., Polat, T., Aydın, G. B., & Akpek, A. (2019) · Current Pharmaceutical Design · doi:10.2174/1381612825666190208122204 · Cited by 44
Khamenehfar, A., Beischlag, T. V., Russell, P. J., Ling, M. T., Nelson, C. C., & Li, P. C. H. (2015) · Biomicrofluidics · doi:10.1063/1.4934715 · Cited by 40
Watanabe, M., Serizawa, M., Sawada, T., Takeda, K., Takahashi, T., Yamamoto, N., Koizumi, F., & Koh, Y. (2014) · Journal of Translational Medicine · doi:10.1186/1479-5876-12-143 · Cited by 45
“Various methods to overcome this issue have been under development and evaluation [18-28].”
MethodIn-flow detection of ultra-small magnetic particles by an integrated giant magnetic impedance sensor
Fodil, K., Denoual, M., Dolabdjian, C. P., Treizebre, A., & Senez, V. (2016) · Applied Physics Letters · doi:10.1063/1.4948286 · Cited by 42
Emerging role of circulating tumor cells in immunotherapy
Rzhevskiy, A. S., Kapitannikova, A. Y., Malinina, P., Volovetsky, A. B., Es, H. A., Kulasinghe, A., Thiery, J. P., Maslennikova, A., Zvyagin, A. V., & Warkiani, M. E. (2021) · Theranostics · doi:10.7150/thno.59677 · Cited by 40
“The presence of CTC appears to correlate with the TNM stage [6, 116-118], lower disease-free and overall survival [119, 120].”
BackgroundSardarabadi, P., Kojabad, A. A., Jafari, D., & Liu, C. (2021) · Biosensors · doi:10.3390/bios11100394 · Cited by 46
“Magnetic CTCs EGFR Immunomagnetic and Magnetic Sifter NA [57]”
BackgroundLiquid biopsy on chip: a paradigm shift towards the understanding of cancer metastasis
Tadimety, A., Syed, A., Nie, Y., Long, C. R., Kready, K. M., & Zhang, J. X. J. (2017) · Integrative Biology · doi:10.1039/c6ib00202a · Cited by 38
Circulating Tumor Cells and Circulating Tumor DNA
Lianidou, E. S., & Hoon, D. S. �. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-816061-9.00009-6 · Cited by 36
Microfluidic applications on circulating tumor cell isolation and biomimicking of cancer metastasis
Xu, X., Jiang, Z., Wang, J., Ren, Y., & Wu, A. (2020) · Electrophoresis · doi:10.1002/elps.201900402 · Cited by 38
Hybrid magnetic and deformability based isolation of circulating tumor cells using microfluidics
Chen, H., Zhang, Z., Liu, H., Zhang, Z., Lin, C., & Wang, B. (2019) · AIP Advances · doi:10.1063/1.5081849 · Cited by 37
Yao, C., Ng, E., & Wang, S. X. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.113982 · Cited by 40
Self-citationNanobiotechnology for the Therapeutic Targeting of Cancer Cells in Blood
Li, J., Sharkey, C. C., Huang, D., & King, M. R. (2015) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-015-0381-z · Cited by 38
Xu, B., Hu, W., Du, W., Hu, Y., Zhang, C., Lao, Z., Ni, J., Li, J., Wu, D. Q., Chu, J., et al. (2017) · Optics Express · doi:10.1364/oe.25.016739 · Cited by 36
A Review on Microdevices for Isolating Circulating Tumor Cells
Lei, K. F. (2020) · Micromachines · doi:10.3390/mi11050531 · Cited by 33
“By using similar magnetic approach, some demonstrations also successfully showed the ability to isolate CTCs [19,20,44,45].”
BackgroundResultBacteria capture with magnetic nanoparticles modified with cationic carbosilane dendritic systems
Quintana, S., Barrios-Gumiel, A., Sánchez‐Nieves, J., Copa-Patiño, J. L., de la Mata, F. J., & Gómez, R. (2021) · Biomaterials Advances · doi:10.1016/j.msec.2021.112622 · Cited by 37
Nanoenabled Bioseparations: Current Developments and Future Prospects
Fahmy, S. A., Alawak, M., Brüßler, J., Bakowsky, U., & El‐Sayed, M. M. H. (2019) · BioMed Research International · doi:10.1155/2019/4983291 · Cited by 35
Liu, Y., Li, R. Q., Zhang, L., & Guo, S. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.850241 · Cited by 39
“Thus, immunoaffinity methods can accurately distinguish between CTCs and numerous background hematologic cells (Talasaz et al., 2009; Earhart et al., 2014).”
BackgroundDendronized magnetic nanoparticles for HIV-1 capture and rapid diagnostic
Barrios-Gumiel, A., Sepúlveda‐Crespo, D., Jiménez, J. L., Gómez, R., Muñoz‐Fernández, M. Á., & de la Mata, F. J. (2019) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2019.05.050 · Cited by 30
Su, Y., Tian, Q., Pan, D., Hui, L., Chen, Y., Zhang, Q., Tian, W., Yu, J., Hu, S., Gao, Y., et al. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b09655 · Cited by 32
Ng, E., Le, A. K., Nguyen, M. H., & Wang, S. X. (2020) · ACS Sensors · doi:10.1021/acssensors.0c00232 · Cited by 31
Self-citationMicrofluidic Devices for Circulating Tumor Cells Isolation and Subsequent Analysis
Khamenehfar, A., & Li, P. C. H. (2016) · Current Pharmaceutical Biotechnology · doi:10.2174/1389201017666160301103509 · Cited by 30
Giant Magnetoresistance Based Biosensors for Cancer Screening and Detection
Mostufa, S., Rezaei, B., Yari, P., Xu, K., Gómez‐Pastora, J., Sun, J., Shi, Z., & Wu, K. (2023) · ACS Applied Bio Materials · doi:10.1021/acsabm.3c00592 · Cited by 35
Advances in AI-assisted biochip technology for biomedicine
Rodoplu, D. (2024) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2024.116997 · Cited by 40
Liquid Biopsy Promotes Non-Small Cell Lung Cancer Precision Therapy
Lü, J., & Han, B. (2018) · Technology in Cancer Research & Treatment · doi:10.1177/1533033818801809 · Cited by 30
Current techniques and future advance of microfluidic devices for circulating tumor cells
Cheng, S., Chen, M., Wang, Y., Sun, Z.-H., Xie, M., & Huang, W. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.06.018 · Cited by 31
Chen, H., Li, Y., Zhang, Z., & Wang, S. (2020) · Biomicrofluidics · doi:10.1063/5.0005373 · Cited by 31
Self-citationZhou, X., Zhang, Y., Kang, K., Mao, Y., Yu, Y., Yi, Q., & Wu, Y. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c04587 · Cited by 29
Modulation of rotation-induced lift force for cell filtration in a low aspect ratio microchannel
Zhou, J., Giridhar, P. V., Kasper, S., & Papautsky, I. (2014) · Biomicrofluidics · doi:10.1063/1.4891599 · Cited by 27
High-gradient magnetic separation using ferromagnetic membrane
Podoynitsyn, S. N., Sorokina, O. N., & Kovarski, A. L. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.08.075 · Cited by 27
Xue, M., Xiang, A., Guo, Y., Wang, L., Wang, R., Wang, W., Ji, G., & Lu, Z. (2019) · RSC Advances · doi:10.1039/c9ra08285a · Cited by 26
Hao, N., Nie, Y., Shen, T., & Zhang, J. X. J. (2018) · Lab on a Chip · doi:10.1039/c8lc00273h · Cited by 25
Magnetic Nanoparticle for Biomedicine Applications
Liu, G., Li, R., & Chen, Y. (2015) · Nanotechnology Nanomedicine & Nanobiotechnology · doi:10.24966/ntmb-2044/100003 · Cited by 31
“24966/NTMB-2044/100003 Volume 2 • Issue 1 • 100003 Depending on the specific functionalization of the MNPs for different targets, this technique has been already applied in the field of the separation and purification of cells [38], proteins [39], bacterial [40] and virus as well.”
MethodHighly sensitive detection of DNA hypermethylation in melanoma cancer cells
Nesvet, J. C., Rizzi, G., & Wang, S. X. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.018 · Cited by 25
Self-citationEmerging microfluidic devices for cancer cells/biomarkers manipulation and detection
Pérez‐González, V. H., Gallo‐Villanueva, R. C., Camacho-León, S., Gomez-Quinones, J., Rodríguez-Delgado, J. M., & Martinez-Chapa, S. O. (2016) · IET Nanobiotechnology · doi:10.1049/iet-nbt.2015.0060 · Cited by 25
Civelekoglu, O., Frazier, A. B., & Sarioglu, A. F. (2022) · Magnetochemistry · doi:10.3390/magnetochemistry8010010 · Cited by 24
“7% peak capture efficiency at 10 mL per hour [73].”
BackgroundInfluentialYin, D., Shi, A., Zhou, B., Wang, M., Xu, G., Shen, M., Zhu, X., & Shi, X. (2022) · Langmuir · doi:10.1021/acs.langmuir.2c01740 · Cited by 21
Hao, N., & Zhang, J. X. J. (2019) · Biomicrofluidics · doi:10.1063/1.5119052 · Cited by 21
Single-cell level point mutation analysis of circulating tumor cells through droplet microfluidics
Qiu, S., Shen, C., Jian, X., Lu, Y., Tong, Z., Wu, Z., Mao, H., & Zhao, J. (2021) · Chinese Chemical Letters · doi:10.1016/j.cclet.2021.08.128 · Cited by 20
Golozar, M., Molki, M., & Darabi, J. (2017) · Microfluidics and Nanofluidics · doi:10.1007/s10404-017-1909-4 · Cited by 22
“…magnetophoretic bioseparation chip utilizes locally engineered high magnetic field gradients and offers significantly higher throughputs compared to the recently developed microfluidic devices where flow rates were limited to less than 30 mL/h (Chen et al. 2014; Earhart et al. 2014).”
BackgroundFundamentals of integrated ferrohydrodynamic cell separation in circulating tumor cell isolation
Liu, Y., Zhao, W., Cheng, R., Harris, B. N., Murrow, J. R., Hodgson, J., Egan, M., Bankey, A., Nikolinakos, P. G., Laver, T., et al. (2021) · Lab on a Chip · doi:10.1039/d1lc00119a · Cited by 22
Detection of Proteins Using Nano Magnetic Particle Accumulation-Based Signal Amplification
İçöz, K., & Mzava, O. (2016) · Applied Sciences · doi:10.3390/app6120394 · Cited by 19
“Micro/nano-cantilevers [1,2], stripe/wires [3,4], and pores [5,6] are some of the platforms.”
BackgroundLi, W., Li, R., Huang, B., Wang, Z., Sun, Y., Wei, X., Heng, C., Liu, W., Yu, M., Guo, S., et al. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab176c · Cited by 19
Relevance of Circulating Tumor Cells as Predictive Markers for Cancer Incidence and Relapse
Chelakkot, C., Yang, H., & Shin, Y. K. (2022) · Pharmaceuticals · doi:10.3390/ph15010075 · Cited by 19
“Magnetic Sifter EpCAM 74% Viable 100% (n = 4) [19] OncoBean Chip EpCAM 90% Viable 100% (n = 4) [20]”
BackgroundMagnetic micro/nanoparticle flocculation-based signal amplification for biosensing
İçöz, K., Mzava, O., & Taş, Z. (2016) · International Journal of Nanomedicine · doi:10.2147/ijn.s108692 · Cited by 17
“Also, magnetic accumulation was tested in mediums with pH levels of 2 and 14.”
Metadata
- Authors
- Earhart, C. M., Hughes, C. E., Gaster, R. S., Ooi, C. C., Wilson, R. J., Zhou, L. Y., Humke, E. W., Xu, L., Wong, D. J., Willingham, S. B., Schwartz, E. J., Weissman, I. L., Jeffrey, S. S., Neal, J. W., Rohatgi, R., Wakelee, H. A., & Wang, S. X.
- Affiliations
- Stanford University (US)
- Stanford Medicine (US)
- Stanford Cancer Institute (US)
- Institute for Stem Cell Biology and Regenerative Medicine (US)
- Corresponding author
- Wang, Shan X.
- ORCID
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 14
- Issue
- 1
- Pages
- 78-88
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- PMC
- PMC4144998
- OpenAlex
- W2020442157
- Cited by
- 165
- References
- 41
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 5 · 2023: 7 · 2022: 16 · 2021: 11 · 2020: 16 · 2019: 22 · 2018: 21 · 2017: 15 · 2016: 22 · 2015: 13 · 2014: 9
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (5u54ca143907-05)
- National Cancer Institute (U54-CA-143907, R33CA138330, U54CA151459)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cancer Research › Cancer Genomics and Diagnostics
- Keywords
- circulating tumor cells, lung cancer, microfluidic cell capture, cell release, protein microarrays, mutation analysis, liquid biopsy, blood-based cancer detection
- MeSH terms
- Epithelial Cell Adhesion Molecule, Antigens, Neoplasm, Carcinoma, Non-Small-Cell Lung, Cell Separation, Humans, Keratins, Lung Neoplasms, Magnetics, Mutation, Neoplastic Cells, Circulating, Cell Adhesion Molecules, Fluorescein-5-isothiocyanate, Cell Line, Tumor, Microfluidic Analytical Techniques, Antibodies, Immobilized, Magnetite Nanoparticles, MCF-7 Cells, ErbB Receptors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.