Oxygen control with microfluidics
The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Cellular function and behavior are affected by the partial pressure of O 2 , or oxygen tension, in the microenvironment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Different from normal fibroblasts, cancer-associated fibroblasts proliferate faster, produce more extracellular matrix and secrete unique cytokine, which significantly enhances carcinogenesis [123, 124].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [124]
In the citing paper
“Different from normal fibroblasts, cancer-associated fibroblasts proliferate faster, produce more extracellular matrix and secrete unique cytokine, which significantly enhances carcinogenesis [123, 124].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [124]
In the citing paper
“A hypoxic environment can be easily incorporated into most existing systems by using a hypoxic incubator or a hypoxic workstation [194].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [194]
In the citing paper
“Many recent microfluidic devices were utilized to generate chemical or oxygen gradient in cancer research because chemical and oxygen concentrations have also been shown to greatly affect cancer progression and therapeutic efficacy [193,194].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [194]
In the citing paper
“Chips based on microfluidics can be designed to realize oxygen gradients with high spatial and temporal resolution, which can be used to simulate the physiological effects of oxygen on tumor progression and metastasis127,128.”
From Tumor-on-a-chip: from bioinspired design to biomedical application (2021) · cites this paper as [128]
Citations
Cites
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Hypoxia-Inducible Factor-1 (HIF-1)
Ke, Q., & Costa, M. (2006) · Molecular Pharmacology · doi:10.1124/mol.106.027029 · Cited by 1,646
Oxygen in Stem Cell Biology: A Critical Component of the Stem Cell Niche
Mohyeldin, A., Garzón-Muvdi, T., & Quiñones-Hinojosa, A. (2010) · Cell Stem Cell · doi:10.1016/j.stem.2010.07.007 · Cited by 1,535
Hypoxia-inducible factor 1: oxygen homeostasis and disease pathophysiology
Semenza, G. L. (2001) · Trends in Molecular Medicine · doi:10.1016/s1471-4914(01)02090-1 · Cited by 930
Continuous Recording of Blood Oxygen Tensions by Polarography
Clark, L. C., Wolf, R., Granger, D., & Taylor, Z. (1953) · Journal of Applied Physiology · doi:10.1152/jappl.1953.6.3.189 · Cited by 886
Metabolic Regulation of Hematopoietic Stem Cells in the Hypoxic Niche
Suda, T., Takubo, K., & Semenza, G. L. (2011) · Cell Stem Cell · doi:10.1016/j.stem.2011.09.010 · Cited by 844
Diffusion of Gases in Silicone Polymers: Molecular Dynamics Simulations
Charati, S. G., & Stern, S. A. (1998) · Macromolecules · doi:10.1021/ma980387e · Cited by 423
Hypoxia or in situ normoxia: The stem cell paradigm
Ivanovic, Z. (2009) · Journal of Cellular Physiology · doi:10.1002/jcp.21690 · Cited by 406
Low oxygen tension inhibits osteogenic differentiation and enhances stemness of human MIAMI cells
D'Ippolito, G., Diabira, S., Howard, G. A., Roos, B. A., & Schiller, P. C. (2006) · Bone · doi:10.1016/j.bone.2006.02.061 · Cited by 388
Formation of steady‐state oxygen gradients in vitro: Application to liver zonation
Allen, J. W., & Bhatia, S. N. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10569 · Cited by 269
Research works printed but not linked: 4
- Barnikol, 2012, Ger. Med. Sci., 10, Doc11
- Ni, 2011, Am. J. Physiol., 300, 189
- S. Grist , L.Yu , L.Chrostowski and K. C.Cheung , SPIE MOEMS-MEMS , 2012 , p. 825103
- J. F. Lo , M.Brennan , Z.Merchant , L.Chen , S.Guo , D. T.Eddington and L. A.DiPietro , Wound repair and regeneration : official publication of the Wound Healing Society [and] the European Tissue Repair Society , vol. 21 , pp. 226–234
Cited by
Items 101–185 of 185
Microfluidic single-cell scale-down systems: introduction, application, and future challenges
Täuber, S., & Grünberger, A. (2023) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2023.102915 · Cited by 16
Gas transport mechanisms through gas-permeable membranes in microfluidics: A perspective
Seo, S., & Kim, T. (2023) · Biomicrofluidics · doi:10.1063/5.0169555 · Cited by 15
Reconstructing the Vascular Developmental Milieu In Vitro
Blatchley, M. R., & Gerecht, S. (2019) · Trends in Cell Biology · doi:10.1016/j.tcb.2019.10.004 · Cited by 16
Shetti, N. P., Malode, S. J., Roy, S., Chandra, P., Reddy, K. R., & Chatterjee, S. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-817923-9.00011-0 · Cited by 14
Compartmentalized organ-on-a-chip structure for spatiotemporal control of oxygen microenvironments
Tornberg, K., Välimäki, H., Valaskivi, S., Mäki, A.-J., Jokinen, M., Kreutzer, J., & Kallio, P. J. (2022) · Biomedical Microdevices · doi:10.1007/s10544-022-00634-y · Cited by 18
Jomezadeh, N., Esfahani, J. A., & Shaegh, S. A. M. (2020) · Engineering Reports · doi:10.1002/eng2.12062 · Cited by 13
Hummitzsch, L., Berndt, R., Lindner, M., Rusch, R., Faendrich, F., Gruenewald, M., Steinfath, M., Albrecht, M., & Zitta, K. (2020) · Journal of Translational Medicine · doi:10.1186/s12967-020-02567-7 · Cited by 13
Rountree, A. M., Karkamkar, A. S., Khalil, G., Folch, A., Cook, D. L., & Sweet, I. R. (2016) · Heliyon · doi:10.1016/j.heliyon.2016.e00210 · Cited by 13
“For instance, microfluidic systems are historically made by lithography out of materials such as polydimethylsiloxane (PDMS) that are gas permeable [24], and in some cases this property is utilized for controlling oxygen levels in the microfluidics device [25, 26].”
BackgroundDigital Twins in Smart Manufacturing
Aziz, S., Jung, D. W., Zaman, U. K. U., & Aqeel, A. B. (2023) · CRC Press eBooks · doi:10.1201/9781003327523-6 · Cited by 15
Advanced in vitro models for renal cell carcinoma therapy design
Mieville, V., Griffioen, A. W., Benamran, D. A., & Nowak-Sliwinska, P. M. (2023) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2023.188942 · Cited by 17
Hypoxic behavior in cells under controlled microfluidic environment
Morshed, A. Z., & Dutta, P. (2017) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2017.01.017 · Cited by 12
“presented this transport process in a simplifiedmodel from a pressure dependent desorption kinetics approach [29].”
BackgroundMethodDesign considerations for open-well microfluidic platforms for hypoxic cell studies
Byrne, M. B., Leslie, M. T., Patel, H. S., Gaskins, H. R., & Kenis, P. J. A. (2017) · Biomicrofluidics · doi:10.1063/1.4998579 · Cited by 15
Barmaki, S., Obermaier, D., Kankuri, E. M., Vuola, J., Franssila, S., & Jokinen, V. P. (2020) · Micromachines · doi:10.3390/mi11110979 · Cited by 12
“Each chemical entered the chip through a dedicated channel [19].”
Background96-Well Oxygen Control Using a 3D-Printed Device
Szmelter, A., Jacob, J., & Eddington, D. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04627 · Cited by 14
Self-citationLiu, P., Fu, L., Song, Z., Man, M., Yuan, H., Zheng, X., Kang, Q., Shen, D., Song, J., Li, B., et al. (2021) · The Analyst · doi:10.1039/d1an00927c · Cited by 12
Khalil, N. N., Rexius‐Hall, M. L., Gupta, D., McCarthy, L., Verma, R., Kellogg, A. C., Takamoto, K., Xu, M., Nejatpoor, T., Parker, S. J., et al. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401478 · Cited by 11
Self-citationMicrofluidic systems in cancer research
Caballero, D., Luque‐González, M. A., Reis, R. L., & Kundu, S. C. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818128-7.00015-0 · Cited by 13
Chen, Y., Wang, J., Hoar, B. B., Lu, S., Guan, X., & Liu, C. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2206321119 · Cited by 11
Sustained delivery of focal ischemia coupled to real-time neurochemical sensing in brain slices
Cryan, M. T., Li, Y., & Ross, A. E. (2022) · Lab on a Chip · doi:10.1039/d1lc00908g · Cited by 11
Engineering Tools for Regulating Hypoxia in Tumour Models
Kim, M. H., Green, S. D., Lin, C., & Koenig, H. (2021) · Journal of Cellular and Molecular Medicine · doi:10.1111/jcmm.16759 · Cited by 9
Park, K., Lee, Y., & Seo, J. (2019) · Current Pharmaceutical Design · doi:10.2174/1381612825666190207093438 · Cited by 9
Self‐sealing thermoplastic fluoroelastomer enables rapid fabrication of modular microreactors
McMillan, A. H., Mora‐Macías, J., Teyssandier, J., Thür, R., Roy, E., Ochoa, I., Feyter, S. D., Vankelecom, I. F. J., Roeffaers, M. B. J., & Lesher‐Pérez, S. C. (2021) · Nano Select · doi:10.1002/nano.202000241 · Cited by 8
Hao, Y., Bao, Y., Huang, X., Hu, Y., & Xiong, B. (2018) · RSC Advances · doi:10.1039/c8ra08276f · Cited by 8
Versatile fabrication and integration method of optical oxygen sensors in organ-on-chips
Bossink, E. G. B. M., Slob, J. V. M., Wasserberg, D., Segerink, L. I., & Odijk, M. (2020) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors47125.2020.9278735 · Cited by 8
“There is a lot of interest in oxygen control in OoC devices, as oxygen is a crucial molecule in the metabolism of human cells since both a deficiency as an abundance of oxygen can cause cell damage or even cell death [4], [5].”
BackgroundMethodHullegie-Peelen, D. M., Hoogduijn, M. J., Hesselink, D. A., & Baan, C. C. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.607953 · Cited by 9
“Oxygen can also be added to the perfusion fluid (131).”
BackgroundYao, M., Walker, G. M., & Gamcsik, M. P. (2021) · Scientific Reports · doi:10.1038/s41598-021-83579-1 · Cited by 9
Xu, W., Foster, E., Ma, C., & Bohn, P. W. (2015) · Microfluidics and Nanofluidics · doi:10.1007/s10404-015-1636-7 · Cited by 8
“Oxygen impacts a variety of vital biological processes and is used as an important factor for constructing physiologically realistic microenvironments in in vitro systems (Brennan et al. 2014).”
BackgroundLiu, P., Fu, L., Li, B., Man, M., Ji, Y., Kang, Q., Sun, X., Shen, D., & Chen, L. (2022) · Environmental Science and Pollution Research · doi:10.1007/s11356-022-23688-0 · Cited by 10
“Many studies have proposed polydimethylsiloxane (PDMS) microfluidic chips to create hypoxic environment (Brennan et al. 2014; Erickstad et al. 2015), for example, microfluidic devices relying on oxygen scavenging chemicals (Chang et al.”
BackgroundOn-chip spectroscopic monitoring of erythrocyte oxygenation under hematocrit and oxygen gradients
Dong, R., Li, Y., Liu, S., Li, W., Tao, L., Chen, C., Qian, Z., & Yang, Y. (2022) · Journal of Science Advanced Materials and Devices · doi:10.1016/j.jsamd.2022.100515 · Cited by 7
Hypoxic Physiological Environments in a Gas-Regulated Microfluidic Device
Lee, I., Woo, J. H., Lee, M., Jeon, T., & Kim, S. M. (2018) · Micromachines · doi:10.3390/mi10010016 · Cited by 7
“Lab-on-chips with different types of gas-permeable membrane [7,8], multilayered chip structure [9], or complex microchannel-integrated devices [10] have been proposed to overcome these hurdles [11].”
Backgroundde Oliveira, E. A., Goding, C. R., & Maria–Engler, S. S. (2020) · Handbook of experimental pharmacology · doi:10.1007/164_2020_369 · Cited by 9
Zou, H., Gao, Y. S., Ding, Z., & Liu, C. (2026) · Journal of the American Chemical Society · doi:10.1021/jacs.5c21704 · Cited by 6
Rapier, C. E., Jagadeesan, S., Vatine, G. D., & Ben‐Yoav, H. (2024) · Biosensors · doi:10.3390/bios14080374 · Cited by 6
“Microfluidic cell culture can control the flow of fluids [4–6], permit multiplexing [7], control the timing of reagents [7], oxygen saturation [8], and cause cellular polarization and transformation [9,10].”
BackgroundTools to understand hypoxia responses in plant tissues
Panicucci, G., Barreto, P., Herzog, M., Lichtenauer, S., Schwarzländer, M., Pedersen, O., & Weits, D. A. (2024) · PLANT PHYSIOLOGY · doi:10.1093/plphys/kiae624 · Cited by 7
Lab-on-Chip Culturing System for Fungi—Towards Nanosatellite Missions
Krakos, A., Śniadek, P., Jurga, M., Białas, M., Kaczmarek-Pieńczewska, A., Matkowski, K., Walczak, R., & Dziuban, J. (2022) · Applied Sciences · doi:10.3390/app122010627 · Cited by 6
“Such devices are being used increasingly often to understand how microorganisms react to space conditions [57,59,67].”
BackgroundCui, B., Wen, M., Zhang, C., Zheng, Y., & Jia, Z. (2026) · Advanced Functional Materials · doi:10.1002/adfm.202532131 · Cited by 5
Causative Role of Anoxic Environment in Bacterial Regulation of Human Intestinal Function
Wang, C., Cancino, A., Baste, J., Marten, D., Joshi, A. A., Nasreen, A., & Bhushan, A. (2022) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-022-00735-x · Cited by 5
Scheidecker, B., Poulain, S., Sugimoto, M., Kido, T., Kawanishi, T., Miyajima, A., Kim, S. H., Arakawa, H., Kato, Y., Nishikawa, M., et al. (2024) · Biofabrication · doi:10.1088/1758-5090/ad30c5 · Cited by 6
“Due to the known spatial oxygen gradient present in microfluidic flow channels [8, 22, 53] and its intrinsic Given the apparent visual overlap of hypoxic gene expression and activated fibroblastic cell fractions (figures 5(a) and 6(a)), we further investigated inflammatory states of analyzed cells…”
Generation of controllable gaseous H 2 S concentrations using microfluidics
Christoforidis, T., Driver, T. G., Rehman, J., & Eddington, D. (2018) · RSC Advances · doi:10.1039/c7ra12220a · Cited by 5
Self-citationA microfluidic bubble perfusion device for brain slice culture
Saleheen, A., Acharyya, D., Prosser, R. A., & Baker, C. A. (2021) · Analytical Methods · doi:10.1039/d0ay02291h · Cited by 5
Microfluidic oxygen tolerability screening of nanocarriers for triplet fusion photon upconversion
Isokuortti, J., Kiiski, I. M. A., Sikanen, T. M., Durandin, N. A., & Laaksonen, T. (2022) · Journal of Materials Chemistry C · doi:10.1039/d2tc00156j · Cited by 5
Electrochemically induced in vitro focal hypoxia in human neurons
Wong, J. J. Y., Varga, B. V., Káradóttir, R. T., & Hall, E. A. H. (2022) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2022.968341 · Cited by 4
“However, these devices still limit differential spatial focal control of oxygen levels that would simulate the brain structure and the infarct (Brennan et al., 2014; Ando et al., 2017; Rexius-Hall et al., 2017).”
BackgroundGril, D., & Đonlagić, D. (2023) · Sensors · doi:10.3390/s23104984 · Cited by 4
Chang, D.-M., Hsu, H., Ko, P., Chang, W.-J., Hsieh, T., Wu, H., & Tung, Y. (2024) · The Analyst · doi:10.1039/d3an01625k · Cited by 4
Microfluidic High-Migratory Cell Collector Suppressing Artifacts Caused by Microstructures
Ishida, T., Shimamoto, T., Kaminaga, M., Kuchimaru, T., Kizaka‐Kondoh, S., & Omata, T. (2019) · Micromachines · doi:10.3390/mi10020116 · Cited by 4
Kołodziejek, D., Sierańska, U., Iwoń, Z., Łopianiak, I., Krogulec, E., Wojasiński, M., & Jastrzębska, E. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.135169 · Cited by 4
Martewicz, S., Gabrel, G., Campesan, M., Canton, M., Lisa, F. D., & Elvassore, N. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b05347 · Cited by 4
Microfluidic Analysis Techniques for Safety Assessment of Pharmaceutical Nano‐ and Microsystems
Sikanen, T. M., Kiiski, I. M. A., & Ollikainen, E. (2020) · Wiley eBooks · doi:10.1002/9781119414018.ch3 · Cited by 4
Edrisi, M., & Rabiee, N. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202504346 · Cited by 5
Duet between sugars and hormones: The molecular dialogue fine‐tuning hypoxia acclimation in plants
Ateeq, M., Ashraf, M. A., Asim, M., Huang, X., Zhu, K., Shabala, S. N., & Liu, J. (2026) · Journal of Integrative Plant Biology · doi:10.1111/jipb.70339 · Cited by 3
Yuan, Z., Sticker, D., Helms, H. C. C., & Kutter, J. P. (2022) · Microfluidics and Nanofluidics · doi:10.1007/s10404-022-02547-x · Cited by 4
Nayak, S., Sondkar, A., Vinchurkar, G., Shirsath, S., Shintre, S., & Vaidhun, B. (2024) · Journal of Exploratory Research in Pharmacology · doi:10.14218/jerp.2023.00006s · Cited by 3
Investigation of tumour environments through advancements in microtechnology and nanotechnology
Liu, Z., Fan, Y. L., Cui, M., Wang, X., & Zhao, P. (2024) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2024.117230 · Cited by 4
Lee, S. Y., & Yang, S. H. (2018) · BioTechniques · doi:10.2144/btn-2018-0013 · Cited by 3
Fattahi, E., Taheri, S., Schilling, A. F., Becker, T. M., & Pörtner, R. (2022) · Engineering in Life Sciences · doi:10.1002/elsc.202100128 · Cited by 3
“As already highlighted in Section 4.2, oxygen transfer is a matter of utmost importance for tissue cultures due to the low solubility of oxygen in the culture medium and the tremendous impact of the oxygen concentration on the physiology of tissue cells [76, 8, 91, 92].”
BackgroundInfluentialBuilding Better Tumor Models: Organoid Systems to Investigate Angiogenesis
Shirure, V. S., Sewell-Loftin, M. K., Lam, S. F., Todd, T. D., Hwang, P. Y., & George, S. C. (2017) · Cancer drug discovery and develogment/Cancer drug discovery and development · doi:10.1007/978-3-319-60511-1_7 · Cited by 4
Skorupska, S., Jastrzębska, E., Chudy, M., Dybko, A., & Brzózka, Z. (2017) · Springer eBooks · doi:10.1007/978-3-319-70685-6_2 · Cited by 3
“The microfluidic systems are high throughput and compatible with cell imaging platforms, which allow to generate multiple conditions with rapid equilibration times (Brennan et al. 2014).”
BackgroundLi, C., Humayun, M., Walker, G. M., Park, K. Y., Connors, B., Feng, J., Hahn, M. C. P., Scarlett, C. O., Li, J., Feng, Y., et al. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.12.16.423117 · Cited by 3
Sitte, Z. R., Miranda, A. A., DiProspero, T. J., & Lockett, M. R. (2024) · HardwareX · doi:10.1016/j.ohx.2024.e00556 · Cited by 3
“The gradients rely on oxygen-permeable materials, chemical reactions that produce or remove oxygen species from the culture medium, or a supply of pre-sparged medium [22 – 25].”
BackgroundYu, Z., Khan, A. A., Naeem, W., Borgia, J. A., Liptay, M. J., Seder, C. W., & Zhou, J. (2025) · APL Bioengineering · doi:10.1063/5.0282002 · Cited by 3
Microfluidics and Lab-on-a-Chip for Biomedical Applications
Patel, D. K., Espinal, M. M., Patil, T. V., Ganguly, K., Dutta, S. D., Luthfikasari, R., & Lim, K. (2022) · Springer eBooks · doi:10.1007/978-3-031-16084-4_11 · Cited by 2
Fu, W., Wang, S., Ouyang, Q., & Luo, C. (2024) · Integrative Biology · doi:10.1093/intbio/zyae011 · Cited by 3
Microfluidic Models of the Tumor Microenvironment
Chang, C.-S., Holter, J. C., & Song, J. W. (2022) · Royal Society of Chemistry eBooks · doi:10.1039/9781839166013-00252 · Cited by 2
Leonard, S. V. L., Booth, Z., Naylor‐Adamson, L., Bibby, L., Wraith, K. S., Pula, G., Arman, M., & Calaminus, S. D. J. (2025) · Biomolecules · doi:10.3390/biom15040501 · Cited by 1
“Most importantly, O 2 gradients that are found in vivo are not possible to replicate within the chamber [42].”
Carvalho, V. M., Rodrigues, N., Sousa, P. J., Pinto, V. C., Rodrigues, C. S., Shin, S. R., Bañobre‐López, M., Minas, G. M. H., Rodrigues, R. O., Lima, R. A., et al. (2024) · Experimental and Computational Multiphase Flow · doi:10.1007/s42757-024-0216-z · Cited by 1
“Among the critical physicochemical parameters influencing tissue and organ homeostasis, oxygen transport is particularly crucial for cellular metabolism and function (Brennan et al., 2014).”
The design basis and application in urology of the tumor-on-a-chip platform
Sheng, F., & Jia, R. (2022) · Urologic Oncology Seminars and Original Investigations · doi:10.1016/j.urolonc.2022.03.012 · Cited by 1
Role of the L-Arginine/NO System in Red Blood Cells at Different Values of Oxygen Partial Pressure
Акулич, Н. В., & Зинчук, В. В. (2022) · Journal of Evolutionary Biochemistry and Physiology · doi:10.1134/s0022093022020223 · Cited by 1
Single‐Cell Hypoxia: Current Analytical Techniques and Future Opportunities
Pappas, D. (2016) · Wiley eBooks · doi:10.1002/9780470027318.a9537 · Cited by 4
Kutsuzawa, N., Nakamura, H., Shinha, K., & Kimura, H. (2026) · Frontiers in Toxicology · doi:10.3389/ftox.2026.1854389
“…including fluid shear stress alone (Jang et al., 2013; Homan et al., 2016; Kann et al., 2022), low O 2 conditions alone or with integrated sensors (Brennan et al., 2014; Azimzadeh et al., 2022), and the combination of hypoxia with mechanical stimulation (Vormann et al., 2022; Shaughnessey et al.,…”
Lesher‐Pérez, S. C. (2015) · Deep Blue (University of Michigan)
Srivastava, R. (2016) · Repository@Hull (Worktribe) (University of Hull)
Nonlinear Oxygen Transport with Poiseuille Hemodynamic Flow in a Micro-Channel
Moschandreou, T. E., & Afas, K. C. (2020) · IntechOpen eBooks · doi:10.5772/intechopen.90575
“A thorough and recent review of oxygen control with microfluidics has been carried out in [10] and all of its references within.”
BackgroundTracking Oxygen Consumption in 3D Cell Cultures with Phosphorescent Biosensors
Rivera, K. R., Craft, M. P., Magness, S. T., & Daniele, M. A.-A. (2020) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors47125.2020.9278675 · Cited by 1
3D microenvironments for in vitro modeling of alzheimer’s disease
Ranjan, V. (2020) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/146832
BIBLIOGRAPHY ON EFFECTS OF RADIATION ON LUBRICANTS
Maughan, G. I. (1960) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Hummitzsch, L., Berndt, R., Kott, M., Rusch, R., Faendrich, F., Gruenewald, M., Steinfath, M., Albrecht, M., & Zitta, K. (2020) · Figshare · doi:10.6084/m9.figshare.13126704
Droplet-based Microfluidic Platform for Quantitative Microbiology
Guermonprez, C. (2016) · theses.fr (ABES) · doi:10.70675/23638018z4a4fz48bbz820bzdaa4e3f738fc · Cited by 2
Hypoxia-on-chip : from technological developments to biological applications
Bouquerel, C. (2023) · theses.fr (ABES) · doi:10.70675/d7d58b5dzd927z4235z8c54z8dbb6fd4757e · Cited by 1
Bacterial resilience and dispersal in dynamic oxygen gradients
Lončar, A., Secchi, E., Jiménez‐Martínez, J., Borgne, T. L., & Tabuteau, H. (2026) · Biomicrofluidics · doi:10.1063/5.0334750
Development of a Flat-Sheet Membrane Gas Exchange Unit for Oxygen Control in Microfluidic Systems
Bussooa, A., de Hemptinne, A., Galand, Q., Briet, M., Bilgen, M., & Malsche, W. D. (2026) · Micromachines · doi:10.3390/mi17091003
“The O 2 level in the cellular microenvironment has a significant effect on cell viability, function, proliferation and differentiation [3,4].”
Pinon, L., Debache, A., Thuaud, A., Tiraboschi, L., Vella, G., Riou-Ramon, J., Cordier, C., Helal, C., Hersen, P., Rescigno, M., et al. (2026) · Communications Biology · doi:10.1038/s42003-026-10675-1
Mellalakari, A., Rodriguez-Trujilllo, R., & Samitier-Martí, J. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-16110-0.00005-4
Metadata
- Authors
- Brennan, M. D., Rexius-Hall, M. L., Elgass, L. J., & Eddington, D. T.
- Affiliations
- University of Illinois Chicago (US)
- UIC Bioengineering (MC 563)
- Corresponding author
- Brennan, Martin D.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 14
- Issue
- 22
- Pages
- 4305-4318
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2041222854
- Semantic Scholar
- 51e7e317be98b914699b6ea585961121bcc072b7
- Cited by
- 188
- References
- 52
- Citations by year
- 2026: 9 · 2025: 2 · 2024: 17 · 2023: 15 · 2022: 32 · 2021: 26 · 2020: 22 · 2019: 14 · 2018: 18 · 2017: 13 · 2016: 11 · 2015: 7 · 2014: 1
- FWCI
- 0.91
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Directorate for Biological Sciences (IDBR NSF 1253060)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- hypoxia, hyperoxia, anoxia, oxygen gradients, oxygen diffusion, oxygen solubility, oxygen tension measurement, live-cell imaging, stem cell proliferation
- MeSH terms
- Animals, Equipment Design, Humans, Oxygen, Cell Culture Techniques, Microfluidic Analytical Techniques, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.