Oxygen control with microfluidics
The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Cellular function and behavior are affected by the partial pressure of O 2 , or oxygen tension, in the microenvironment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Different from normal fibroblasts, cancer-associated fibroblasts proliferate faster, produce more extracellular matrix and secrete unique cytokine, which significantly enhances carcinogenesis [123, 124].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [124]
In the citing paper
“Different from normal fibroblasts, cancer-associated fibroblasts proliferate faster, produce more extracellular matrix and secrete unique cytokine, which significantly enhances carcinogenesis [123, 124].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [124]
In the citing paper
“A hypoxic environment can be easily incorporated into most existing systems by using a hypoxic incubator or a hypoxic workstation [194].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [194]
In the citing paper
“Many recent microfluidic devices were utilized to generate chemical or oxygen gradient in cancer research because chemical and oxygen concentrations have also been shown to greatly affect cancer progression and therapeutic efficacy [193,194].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [194]
In the citing paper
“Chips based on microfluidics can be designed to realize oxygen gradients with high spatial and temporal resolution, which can be used to simulate the physiological effects of oxygen on tumor progression and metastasis127,128.”
From Tumor-on-a-chip: from bioinspired design to biomedical application (2021) · cites this paper as [128]
Citations
Cites
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Hypoxia-Inducible Factor-1 (HIF-1)
Ke, Q., & Costa, M. (2006) · Molecular Pharmacology · doi:10.1124/mol.106.027029 · Cited by 1,646
Oxygen in Stem Cell Biology: A Critical Component of the Stem Cell Niche
Mohyeldin, A., Garzón-Muvdi, T., & Quiñones-Hinojosa, A. (2010) · Cell Stem Cell · doi:10.1016/j.stem.2010.07.007 · Cited by 1,535
Hypoxia-inducible factor 1: oxygen homeostasis and disease pathophysiology
Semenza, G. L. (2001) · Trends in Molecular Medicine · doi:10.1016/s1471-4914(01)02090-1 · Cited by 930
Continuous Recording of Blood Oxygen Tensions by Polarography
Clark, L. C., Wolf, R., Granger, D., & Taylor, Z. (1953) · Journal of Applied Physiology · doi:10.1152/jappl.1953.6.3.189 · Cited by 886
Metabolic Regulation of Hematopoietic Stem Cells in the Hypoxic Niche
Suda, T., Takubo, K., & Semenza, G. L. (2011) · Cell Stem Cell · doi:10.1016/j.stem.2011.09.010 · Cited by 844
Diffusion of Gases in Silicone Polymers: Molecular Dynamics Simulations
Charati, S. G., & Stern, S. A. (1998) · Macromolecules · doi:10.1021/ma980387e · Cited by 423
Hypoxia or in situ normoxia: The stem cell paradigm
Ivanovic, Z. (2009) · Journal of Cellular Physiology · doi:10.1002/jcp.21690 · Cited by 406
Low oxygen tension inhibits osteogenic differentiation and enhances stemness of human MIAMI cells
D'Ippolito, G., Diabira, S., Howard, G. A., Roos, B. A., & Schiller, P. C. (2006) · Bone · doi:10.1016/j.bone.2006.02.061 · Cited by 388
Formation of steady‐state oxygen gradients in vitro: Application to liver zonation
Allen, J. W., & Bhatia, S. N. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10569 · Cited by 269
Research works printed but not linked: 4
- Barnikol, 2012, Ger. Med. Sci., 10, Doc11
- Ni, 2011, Am. J. Physiol., 300, 189
- S. Grist , L.Yu , L.Chrostowski and K. C.Cheung , SPIE MOEMS-MEMS , 2012 , p. 825103
- J. F. Lo , M.Brennan , Z.Merchant , L.Chen , S.Guo , D. T.Eddington and L. A.DiPietro , Wound repair and regeneration : official publication of the Wound Healing Society [and] the European Tissue Repair Society , vol. 21 , pp. 226–234
Cited by
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Vacuum filling of complex microchannels with liquid metal
Lin, Y., Gordon, O., Khan, M. R., Vasquez, N., Genzer, J., & Dickey, M. D. (2017) · Lab on a Chip · doi:10.1039/c7lc00426e · Cited by 257
Tumor-on-a-chip: from bioinspired design to biomedical application
Liu, X., Fang, J., Huang, S., Wu, X., Xie, X., Wang, J., Liu, F., Zhang, M., Peng, Z., & Hu, N. (2021) · Microsystems & Nanoengineering · doi:10.1038/s41378-021-00277-8 · Cited by 246
Microfluidic modelling of the tumor microenvironment for anti-cancer drug development
Shang, M., Soon, R. H., Lim, C. T., Khoo, B. L., & Han, J. (2019) · Lab on a Chip · doi:10.1039/c8lc00970h · Cited by 227
Azizgolshani, H., Coppeta, J. R., Vedula, E. M., Marr, E. E., Cain, B. P., Luu, R. J., Lech, M. P., Kann, S. H., Mulhern, T. J., Tandon, V., et al. (2021) · Lab on a Chip · doi:10.1039/d1lc00067e · Cited by 225
Microsensor systems for cell metabolism – from 2D culture to organ-on-chip
Kieninger, J., Weltin, A., Flamm, H., & Urban, G. A. (2018) · Lab on a Chip · doi:10.1039/c7lc00942a · Cited by 198
Xu, L., Lee, H., Jetta, D., & Oh, K. W. (2015) · Lab on a Chip · doi:10.1039/c5lc00716j · Cited by 164
Mousavi Shaegh, S. A., De Ferrari, F., Zhang, Y. S., Nabavinia, M., Binth Mohammad, N., Ryan, J., Pourmand, A., Laukaitis, E., Banan Sadeghian, R., Nadhman, A., et al. (2016) · Biomicrofluidics · doi:10.1063/1.4955155 · Cited by 160
Ferrari, E., Palma, C., Vesentini, S., Occhetta, P., & Rasponi, M. (2020) · Biosensors · doi:10.3390/bios10090110 · Cited by 172
“In summary, detecting the concentration of dissolved oxygen in cell culture medium is crucial for monitoring cell culture conditions in a variety of OoC applications as alterations or strong variations in organ-specific culture conditions may lead to unintended cell stress and damage [80].”
BackgroundOnline oxygen monitoring using integrated inkjet-printed sensors in a liver-on-a-chip system
Moya, A., Ortega-Ribera, M., Guimerà, X., Sowade, E., Zea, M., Illa, X., Ramon, E., Villa, R., Gracia-Sancho, J., & Gabriel, G. (2018) · Lab on a Chip · doi:10.1039/c8lc00456k · Cited by 141
Lee-Montiel, F. T., George, S. M., Gough, A. H., Sharma, A. D., Wu, J., DeBiasio, R., Vernetti, L. A., & Taylor, D. L. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217703978 · Cited by 141
Li, X., George, S. M., Vernetti, L., Gough, A. H., & Taylor, D. L. (2018) · Lab on a Chip · doi:10.1039/c8lc00418h · Cited by 137
Applications of tumor chip technology
Hachey, S. J., & Hughes, C. C. W. (2018) · Lab on a Chip · doi:10.1039/c8lc00330k · Cited by 128
Microfluidic Tissue Engineering and Bio‐Actuation
Filippi, M., Buchner, T., Yaşa, Ö., Weirich, S., & Katzschmann, R. K. (2022) · Advanced Materials · doi:10.1002/adma.202108427 · Cited by 133
Microfluidics as an Emerging Platform for Exploring Soil Environmental Processes: A Critical Review
Zhu, X., Wang, K., Yan, H., Liu, C., Zhu, X., & Chen, B. (2022) · Environmental Science & Technology · doi:10.1021/acs.est.1c03899 · Cited by 116
Wang, X., Sun, Q., & Pei, J. (2018) · Micromachines · doi:10.3390/mi9100493 · Cited by 106
“For example, due to the high gas permeability of PDMS used in microfluidics, both hypoxia microenvironment and oxygen tension gradient can be flexibly created by flowing different gases with certain concentration, perfusing gas-equilibrated medium, or loading oxygen scavenging or generation chemicals [79,80].”
BackgroundImplementing oxygen control in chip-based cell and tissue culture systems
Oomen, P. E., Skolimowski, M. D., & Verpoorte, E. (2016) · Lab on a Chip · doi:10.1039/c6lc00772d · Cited by 103
Current methods for studying metastatic potential of tumor cells
Bouchalová, P., & Bouchal, P. (2022) · Cancer Cell International · doi:10.1186/s12935-022-02801-w · Cited by 120
“The application of a tumor organoid embedded in microfluidic devices makes it possible to modify oxygen pressure, which is fundamental for the tumor cell phenotype during the metastatic process, as a natural TME is hypoxic with an oxygen gradient present [114].”
BackgroundDiscrepancies on the Role of Oxygen Gradient and Culture Condition on Mesenchymal Stem Cell Fate
Samal, J. R. K., Rangasami, V. K., Samanta, S., Varghese, O. P., & Oommen, O. P. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002058 · Cited by 101
Organs-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96
“To overcome this limitation, to enhance the selectivity of the electrode and to avoid bio-fouling, a polytetrafluoroethylene (OTFE) membrane around WE can be adopted (129).”
BackgroundCell maturation: Hallmarks, triggers, and manipulation
Alvarez-Dominguez, J. R., & Melton, D. A. (2022) · Cell · doi:10.1016/j.cell.2021.12.012 · Cited by 92
Impact of hypoxia on DNA repair and genome integrity
Kaplan, A. R., & Glazer, P. M. (2019) · Mutagenesis · doi:10.1093/mutage/gez019 · Cited by 99
“However, recent advances in microfluidics and biomaterials have allowed for the development of novel model systems to induce hypoxia with a higher degree of spatial control (23,24).”
BackgroundEnhanced and homogeneous oxygen availability during incubation of microfluidic droplets
Mahler, L., Tovar, M., Weber, T., Brandes, S., Rudolph, M. M., Ehgartner, J., Mayr, T., Figge, M. T., Roth, M. M., & Zang, E. (2015) · RSC Advances · doi:10.1039/c5ra20118g · Cited by 82
Smart Cell Culture Systems: Integration of Sensors and Actuators into Microphysiological Systems
Modena, M. M., Chawla, K., Misun, P. M., & Hierlemann, A. R. (2018) · ACS Chemical Biology · doi:10.1021/acschembio.7b01029 · Cited by 85
Zheng, L., Wang, B., Sun, Y., Dai, B., Fu, Y., Zhang, Y., Wang, Y., Yang, Z., Sun, Z., Zhuang, S., et al. (2021) · ACS Sensors · doi:10.1021/acssensors.0c01846 · Cited by 78
Grist, S. M., Nasseri, S. S., Laplatine, L., Schmok, J. C., Yao, D. R., Hua, J., Chrostowski, L., & Cheung, K. C. (2019) · Scientific Reports · doi:10.1038/s41598-019-54001-8 · Cited by 79
Advances in Microfluidic Technologies in Organoid Research
Liu, H., Gan, Z., Qin, X., Wang, Y., & Qin, J. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202302686 · Cited by 74
Breaking the mold: 3D cell cultures reshaping the future of cancer research
Cordeiro, S. Z., Oliveira, B. B. P. P., Valente, R., Ferreira, D., Luz, A., Baptista, P. V., & Fernandes, A. R. (2024) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2024.1507388 · Cited by 76
Dispersible oxygen microsensors map oxygen gradients in three-dimensional cell cultures
Lesher‐Pérez, S. C., Kim, G.-A., Kuo, C.-H., Leung, B. M., Mong, S., Kojima, T., Moraes, C., Thouless, M. D., Luker, G. D., & Takayama, S. (2017) · Biomaterials Science · doi:10.1039/c7bm00119c · Cited by 63
Bridging the gap between tumor-on-chip and clinics: a systematic review of 15 years of studies
Bouquerel, C., Dubrova, A., Hofer, I., Phan, D. T. T., Bernheim, M., Ladaigue, S., Cavaniol, C., Maddalo, D., Cabel, L., Mechta-Grigoriou, F., et al. (2023) · Lab on a Chip · doi:10.1039/d3lc00531c · Cited by 58
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Sticker, D., Rothbauer, M., Ehgartner, J., Steininger, C., Liske, O., Liska, R., Neuhaus, W., Mayr, T., Haraldsson, T., Kutter, J. P., et al. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b19641 · Cited by 61
Oxygen control: the often overlooked but essential piece to create better in vitro systems
Palacio-Castañeda, V., Velthuijs, N., Gac, S. L., & Verdurmen, W. P. R. (2022) · Lab on a Chip · doi:10.1039/d1lc00603g · Cited by 62
Koens, R., Tabata, Y., Serrano, J. C., Aratake, S., Yoshino, D., Kamm, R. D., & Funamoto, K. (2020) · APL Bioengineering · doi:10.1063/1.5127069 · Cited by 53
Metabolic Switching of Tumor Cells under Hypoxic Conditions in a Tumor-on-a-chip Model
Palacio-Castañeda, V., Kooijman, L. J., Venzac, B., Verdurmen, W. P. R., & Gac, S. L. (2020) · Micromachines · doi:10.3390/mi11040382 · Cited by 54
“A variety of platforms have been reported to address this significant limitation of PDMS and to apply well-defined oxygen tension or to create oxygen gradients across cell cultures, as recently reviewed [26,27].”
BackgroundEngineering Organ-on-a-Chip to Accelerate Translational Research
Ko, J., Park, D., Lee, S., Gümüşcü, B., & Jeon, N. L. (2022) · Micromachines · doi:10.3390/mi13081200 · Cited by 59
“Other than mechanical stimulation, microfluidic chips facilitate generating biochemical stimulation such as oxygen, [53,54].”
BackgroundThe effects of hypoxia on in vitro culture of dental-derived stem cells
Werle, S. B., Chagastelles, P. C., Pranke, P. H. L., & Casagrande, L. (2016) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2016.03.011 · Cited by 53
Qiang, Y., Liu, J., Dao, M., & Du, E. (2021) · Lab on a Chip · doi:10.1039/d1lc00598g · Cited by 48
Berger Fridman, I., Ugolini, G. S., VanDelinder, V., Cohen, S., & Konry, T. (2021) · Biofabrication · doi:10.1088/1758-5090/abdb88 · Cited by 46
“Several microfluidic designs have demonstrated this concept and applied it to systems for 2D or 3D cell culture for different biological applications including tumors and tumor 3D models [34, 35].”
Hypoxia‐enhanced adhesion of red blood cells in microscale flow
Kim, M., Alapan, Y., Adhikari, A., Little, J. A., & Gurkan, U. A. (2017) · Microcirculation · doi:10.1111/micc.12374 · Cited by 48
Endothelial monolayer permeability under controlled oxygen tension
Funamoto, K., Yoshino, D., Matsubara, K., Zervantonakis, I. K., Funamoto, K., NAKAYAMA, M., Masamune, J., Kimura, Y., & Kamm, R. D. (2017) · Integrative Biology · doi:10.1039/c7ib00068e · Cited by 53
Myers, D. R., & Lam, W. A. (2021) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-091520-025358 · Cited by 51
In vitro three-dimensional cell cultures for bone sarcomas
Muñoz-García, J., Jubelin, C., Loussouarn, A., Goumard, M., Griscom, L., Renodon‐Cornière, A., Heymann, M., & Heymann, D. (2021) · Journal of bone oncology · doi:10.1016/j.jbo.2021.100379 · Cited by 55
A 3D-Printed Oxygen Control Insert for a 24-Well Plate
Brennan, M., Rexius‐Hall, M. L., & Eddington, D. (2015) · PLoS ONE · doi:10.1371/journal.pone.0137631 · Cited by 48
“Typically cell culture studies are performed at 21% oxygen, atmospheric oxygen conditions, although levels that cells experience in vivo are less than 21% [35].”
BackgroundSelf-citationReview of Oxygenation with Nanobubbles: Possible Treatment for Hypoxic COVID-19 Patients
Afshari, R., Akhavan, O., Hamblin, M. R., & Varma, R. S. (2021) · ACS Applied Nano Materials · doi:10.1021/acsanm.1c01907 · Cited by 45
Zhang, Y., Yu, T., Ding, J., & Li, Z. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114798 · Cited by 45
Leygeber, M., Lindemann, D., Sachs, C. C., Kaganovitch, E., Wiechert, W., Nöh, K., & Kohlheyer, D. (2019) · Journal of Molecular Biology · doi:10.1016/j.jmb.2019.04.025 · Cited by 48
Electricity-powered artificial root nodule
Lu, S., Guan, X., & Liu, C. (2020) · Nature Communications · doi:10.1038/s41467-020-15314-9 · Cited by 42
Technological tools and strategies for culturing human gut microbiota in engineered in vitro models
Sardelli, L., Perottoni, S., Tunesi, M., Boeri, L., Fusco, F., Petrini, P., Albani, D., & Giordano, C. (2021) · Biotechnology and Bioengineering · doi:10.1002/bit.27816 · Cited by 43
“This implies the fall in Reynolds number while increasing the laminarity of the flow (Brennan et al., 2014).”
BackgroundRexius‐Hall, M. L., Rehman, J., & Eddington, D. (2017) · Integrative Biology · doi:10.1039/c7ib00099e · Cited by 39
Self-citationYang, W., Li, T., Liao, S., Zhou, J., & Huang, L. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117569 · Cited by 44
Grist, S., Schmok, J., Liu, M.-C., Chrostowski, L., & Cheung, K. (2015) · Sensors · doi:10.3390/s150820030 · Cited by 36
“summarizes the various methods that have been employed [32].”
MethodKim, B. J., Chu, I., Jusuf, S., Kuo, T., TerAvest, M. A., Angenent, L. T., & Wu, M. (2016) · Frontiers in Microbiology · doi:10.3389/fmicb.2016.01438 · Cited by 33
Advances in numerical approaches for microfluidic cell analysis platforms
Sheidaei, Z., Akbarzadeh, P., & Kashaninejad, N. (2020) · Journal of Science Advanced Materials and Devices · doi:10.1016/j.jsamd.2020.07.008 · Cited by 45
Perottoni, S., Neto, N. G. B., Nitto, C. D., Dmitriev, R. I., Raimondi, M. T., & Monaghan, M. G. (2021) · Lab on a Chip · doi:10.1039/d0lc01034k · Cited by 37
Dhiman, S., Andrian, T., González, B. S., Tholen, M. M. E., Wang, Y., & Albertazzi, L. (2021) · Chemical Science · doi:10.1039/d1sc05506b · Cited by 38
Jiang, N., Ying, G., Yin, Y., Guo, J., Lozada, J., Padilla, A. V., Gómez, A., de Melo, B. A. G., Mestre, F. L., Gansevoort, M., et al. (2024) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2413684121 · Cited by 38
“1 A ) ( 25 ).”
Hoyle, H. W., Stenger, C. M. L., & Przyborski, S. A. (2022) · Biomaterials and Biosystems · doi:10.1016/j.bbiosy.2022.100063 · Cited by 36
Fabrication of composite microfluidic devices for local control of oxygen tension in cell cultures
Gao, Y., Stybayeva, G., & Revzin, A. (2018) · Lab on a Chip · doi:10.1039/c8lc00825f · Cited by 31
Wu, H., Lee, T., Ko, P., Liao, W., Hsieh, T., & Tung, Y. (2019) · The Analyst · doi:10.1039/c9an00143c · Cited by 32
Bunge, F., van den Driesche, S., & Vellekoop, M. J. (2017) · Sensors · doi:10.3390/s17071603 · Cited by 29
“The supply with gases is realized either by dissolving the gases in the culture medium [18] or by diffusion through the chip material [19].”
BackgroundTäuber, S., von Lieres, E., & Grünberger, A. (2020) · Small · doi:10.1002/smll.201906670 · Cited by 28
Coliaie, P., Kelkar, M. S., Langston, M., Liu, C., Nazemifard, N., Patience, D. B., Skliar, D. B., Nere, N. K., & Singh, M. R. (2021) · Lab on a Chip · doi:10.1039/d1lc00218j · Cited by 25
Breedam, E. V., & Ponsaerts, P. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23137140 · Cited by 28
Ong, L. J. Y., Sun, A. R., Wang, Z., Lee, J., Prasadam, I., & Toh, Y. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202315608 · Cited by 23
Review of microfluidic cell culture devices for the control of gaseous microenvironments in vitro
Wu, H., Lee, T.-A., Ko, P.-L., Chiang, H.-J., Peng, C.-C., & Tung, Y. (2018) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aaa993 · Cited by 24
Gas Partial Pressure in Cultured Cells: Patho-Physiological Importance and Methodological Approaches
Farré, R., Almendros, I., Montserrat, J. M., Gozal, D., & Navajas, D. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01803 · Cited by 25
“Moreover, they can also be implemented in microscopic settings using microfluidic techniques to obtain chips for specific control of gas partial pressures in cultured cells (Brennan et al., 2014).”
BackgroundKurth, F., Györvary, E., Heub, S., Ledroit, D., Paoletti, S., Renggli, K., Revol, V., Verhulsel, M., Weder, G., & Loizeau, F. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817202-5.00003-6 · Cited by 31
Oxygen Gradient Induced in Microfluidic Chips Can Be Used as a Model for Liver Zonation
Ghafoory, S., Stengl, C., Kopany, S., Mayadag, M., Mechtel, N., Murphy, B., Schattschneider, S., Wilhelmi, N., & Wölfl, S. (2022) · Cells · doi:10.3390/cells11233734 · Cited by 25
Gas-modulating microcapsules for spatiotemporal control of hypoxia
Molley, T. G., Jiang, S., Ong, L. J. Y., Kopecky, C., Ranaweera, C. D., Jalandhra, G. K., Milton, L. A., Kardia, E., Zhou, Z., Rnjak‐Kovacina, J., et al. (2023) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2217557120 · Cited by 27
Application of microfluidic chips in anticancer drug screening
Fan, X., Deng, Z.-F., Yan, Y., Vé, O., Shypko, A., Orel, V. B., Ivanova, D., Pilarsky, C. P., Tang, J. P., Chen, Z., et al. (2021) · Biomolecules and Biomedicine · doi:10.17305/bjbms.2021.6484 · Cited by 27
Li, C., Humayun, M., Walker, G. M., Park, K. Y., Connors, B., Feng, J., Pellitteri-Hahn, M. C., Scarlett, C. O., Li, J., Feng, Y., et al. (2022) · Advanced Science · doi:10.1002/advs.202104510 · Cited by 24
Quantitative design strategies for fine control of oxygen in microfluidic systems
Shirure, V. S., Lam, S. F., Shergill, B., Chu, Y. E., Ng, N. R., & George, S. C. (2020) · Lab on a Chip · doi:10.1039/d0lc00350f · Cited by 21
Ahmed, M. A. M., & Nagelkerke, A. (2021) · Organs-on-a-Chip · doi:10.1016/j.ooc.2021.100012 · Cited by 25
O2-Tuned Protein Synthesis Machinery in Escherichia coli-Based Cell-Free System
Lin, X., Zhou, C., Zhu, S., Deng, H., Zhang, J., & Lu, Y. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00312 · Cited by 24
Rapid sample preparation for detection of antibiotic resistance on a microfluidic disc platform
Perebikovsky, A., Liu, Y., Hwu, A. T., Kido, H., Shamloo, E., Song, D., Monti, G. K., Shoval, O., Gussin, D., & Madou, M. J. (2020) · Lab on a Chip · doi:10.1039/d0lc00838a · Cited by 21
Hsu, H., Ko, P., Peng, C., Cheng, Y.-J., Wu, H., & Tung, Y. (2023) · Materials Today Bio · doi:10.1016/j.mtbio.2023.100703 · Cited by 24
“Recently, several microfluidic devices have also been developed to control oxygen tensions and generate oxygen gradients for cell culture in two- and three-dimensional manners [20].”
BackgroundMicrofluidic integrated gas sensors for smart analyte detection: a comprehensive review
Yeganegi, A., Yazdani, K., Tasnim, N., Fardindoost, S., & Hoorfar, M. (2023) · Frontiers in Chemistry · doi:10.3389/fchem.2023.1267187 · Cited by 20
Controlling Microenvironments with Organs-on-Chips for Osteoarthritis Modelling
Ong, L. J. Y., Fan, X., Sun, A. R., Mei, L., Toh, Y., & Prasadam, I. (2023) · Cells · doi:10.3390/cells12040579 · Cited by 22
“The mimicry of the hypoxia region in microfluidic joint models is particularly important since healthy articular chondrocytes rely on hypoxia to retain their metabolism and matrix synthesis [54,55].”
BackgroundInfluentialWulftange, W. J., Rose, M. A., Garmendia‐Cedillos, M., da Silva, D., Poprawski, J. E., Srinivasachar, D., Sullivan, T., Lim, L., Bliskovsky, V. V., Hall, M. D., et al. (2019) · Journal of Cellular Physiology · doi:10.1002/jcp.28665 · Cited by 21
Oxygen Measurement in Microdevices
Grist, S. M., Bennewith, K. L., & Cheung, K. C. (2022) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061020-111458 · Cited by 20
A microfluidic chip of multiple-channel array with various oxygen tensions for drug screening
Li, Y., Li, L., Liu, Z., Ding, M., Luo, G., & Liang, Q. (2016) · Microfluidics and Nanofluidics · doi:10.1007/s10404-016-1762-x · Cited by 19
Kotecha, M., Epel, B., Ravindran, S., Dorcemus, D., Nukavarapu, S., & Halpern, H. (2017) · Tissue Engineering. Part C, Methods · doi:10.1089/ten.tec.2017.0236 · Cited by 17
Yalikun, Y., Tanaka, N., Hosokawa, Y., Iino, T., & Tanaka, Y. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0227-7 · Cited by 20
“…cultured cells enough oxygen in a closed device without flow, a gas-permeable material: polydimethylsiloxane (PDMS) is usually used for cell-culturingmicrofluidic devices (Oomen et al. 2016; Markov et al. 2014; Brennan et al. 2014; Leclerc et al. 2003; Leclerc et al. 2004; Mata et al. 2005).”
BackgroundMethodBoyce, M. W., Simke, W. C., Kenney, R. M., & Lockett, M. R. (2020) · Analytical Methods · doi:10.1039/c9ay01690b · Cited by 19
Kiiski, I. M. A., Järvinen, P. P., Ollikainen, E., Jokinen, V. P., & Sikanen, T. M. (2021) · Lab on a Chip · doi:10.1039/d0lc01292k · Cited by 18
Precise and fast control of the dissolved oxygen level for tumor-on-chip
Bouquerel, C., César, W., Barthod, L., Arrak, S., Battistella, A., Gropplero, G., Mechta‐Grigoriou, F., Zalcman, G., Parrini, M. C., Verhulsel, M., et al. (2022) · Lab on a Chip · doi:10.1039/d2lc00696k · Cited by 22
A New Approach for On-Demand Generation of Various Oxygen Tensions for In Vitro Hypoxia Models
Li, C., Chaung, W. W., Mozayan, C., Chabra, R., Wang, P., & Narayan, R. K. (2016) · PLoS ONE · doi:10.1371/journal.pone.0155921 · Cited by 19
“However, it can be applied to microfluidic devices to control local and complex oxygen of micro-environments that can closely mimic the microenvironment of living tissue [13].”
BackgroundGermain, T., Ansari, M., & Pappas, D. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.07.040 · Cited by 19
Lee, J., Maji, S., & Lee, H. (2023) · Biotechnology Journal · doi:10.1002/biot.202300154 · Cited by 19
“In this regard, numerous methods enabling real-time monitoring without impairing the functionality of OOCs have been proposed in recent years (12-17).”
MethodYakavets, I., Ayachit, M., Kheiri, S., Chen, Z., Rakhshani, F., McWhirter, S., Young, E. W. K., Walker, G. C., & Kumacheva, E. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c16330 · Cited by 20
Microfluidic liquid-air dual-gradient chip for synergic effect bio-evaluation of air pollutant
Liu, X., Hu, S., Xu, B.-Y., Zhao, G., Li, X., Xie, F., Xu, J., & Chen, H. (2018) · Talanta · doi:10.1016/j.talanta.2018.01.087 · Cited by 17
Werle, S. B., Chagastelles, P. C., Pranke, P. H. L., & Casagrande, L. (2018) · Clinical Oral Investigations · doi:10.1007/s00784-018-2427-9 · Cited by 21
Organ-on-Chip Technology for Aerobic Intestinal Host – Anaerobic Microbiota Research
Bossink, E. G. B. M., Segerink, L. I., & Odijk, M. (2021) · Organs-on-a-Chip · doi:10.1016/j.ooc.2021.100013 · Cited by 18
Validation of HepG2/C3A Cell Cultures in Cyclic Olefin Copolymer Based Microfluidic Bioreactors
Etxeberria, L., Messelmani, T., Badiola, J. H., Llobera, A., Fernández, L. J., Vilas‐Vilela, J. L., Leclerc, É., Legallais, C., Jellali, R., & Zaldua, A. M. (2022) · Polymers · doi:10.3390/polym14214478 · Cited by 18
“Normoxic levels for liver tissue are reported to be between 10 and 13 %, which can be maintained with oxygen perfusion methods, the addition of oxygen generating chemicals to the perfused fluid or even using hybrid microfluidic devices (combining oxygen-permeable and -impermeable materials) in case longer experiments…”
BackgroundEngineering perfused microvascular networks into microphysiological systems platforms
Andrejecsk, J. W., & Hughes, C. C. W. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2018.02.002 · Cited by 18
Automated electrochemical oxygen sensing using a 3D-printed microfluidic lab-on-a-chip system
Kaufman, D., Winkler, S., Heuer, C., Shibli, A., Snezhko, A., Livshits, G. I., Bahnemann, J., & Ben‐Yoav, H. (2024) · Lab on a Chip · doi:10.1039/d4lc00962b · Cited by 19
Fibrosis‐on‐Chip: A Guide to Recapitulate the Essential Features of Fibrotic Disease
Streutker, E. M., Devamoglu, U., Vonk, M. C., Verdurmen, W. P. R., & Gac, S. L. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202303991 · Cited by 18
Yang, W., Luo, C., Lai, L., & Ouyang, Q. (2015) · Biomicrofluidics · doi:10.1063/1.4929406 · Cited by 15
Discretizing Three‐Dimensional Oxygen Gradients to Modulate and Investigate Cellular Processes
Blatchley, M. R., Hall, F. D., Ntekoumes, D., Cho, H., Kailash, V., Vázquez-Duhalt, R., & Gerecht, S. (2021) · Advanced Science · doi:10.1002/advs.202100190 · Cited by 15
Metadata
- Authors
- Brennan, M. D., Rexius-Hall, M. L., Elgass, L. J., & Eddington, D. T.
- Affiliations
- University of Illinois Chicago (US)
- UIC Bioengineering (MC 563)
- Corresponding author
- Brennan, Martin D.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 14
- Issue
- 22
- Pages
- 4305-4318
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2041222854
- Semantic Scholar
- 51e7e317be98b914699b6ea585961121bcc072b7
- Cited by
- 188
- References
- 52
- Citations by year
- 2026: 9 · 2025: 2 · 2024: 17 · 2023: 15 · 2022: 32 · 2021: 26 · 2020: 22 · 2019: 14 · 2018: 18 · 2017: 13 · 2016: 11 · 2015: 7 · 2014: 1
- FWCI
- 0.91
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Directorate for Biological Sciences (IDBR NSF 1253060)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- hypoxia, hyperoxia, anoxia, oxygen gradients, oxygen diffusion, oxygen solubility, oxygen tension measurement, live-cell imaging, stem cell proliferation
- MeSH terms
- Animals, Equipment Design, Humans, Oxygen, Cell Culture Techniques, Microfluidic Analytical Techniques, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.