Measuring direct current trans-epithelial electrical resistance in organ-on-a-chip microsystems
Open accessThe DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
Trans-epithelial electrical resistance (TEER) measurements are widely used as real-time, non-destructive, and label-free measurements of epithelial and endothelial barrier function. TEER measurements are ideal for characterizing tissue barrier function in organs-on-chip studies for drug testing and investigation of human disease models; however, published reports using this technique have reported highly conflicting results even with identical cell lines and experimental setups. The differences are even more dramatic when comparing measurements in conventional Transwell systems with those obtained in microfluidic systems. Our goal in this work was therefore to enhance the fidelity of TEER measurements in microfluidic organs-on-chips, specifically using direct current (DC) measurements of TEER, as this is the most widely used method reported in the literature. Here we present a mathematical model that accounts for differences measured in TEER between microfluidic chips and Transwell systems, which arise from differences in device geometry. The model is validated by comparing TEER measurements obtained in a microfluidic gut-on-a-chip device versus in a Transwell culture system. Moreover, we show that even small gaps in cell coverage (e.g., 0.4%) are sufficient to cause a significant (~80%) drop in TEER. Importantly, these findings demonstrate that TEER measurements obtained in microfluidic systems, such as organs-on-chips, require special consideration, specifically when results are to be compared with measurements obtained from Transwell systems.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Astrocyte-endothelial interactions at the blood-brain barrier
Abbott, N. J., Rönnbäck, L., & Hansson, E. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1824 · Cited by 5,595
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationKim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Self-citationDerivation of blood-brain barrier endothelial cells from human pluripotent stem cells
Lippmann, E. S., Azarin, S. M., Kay, J. E., Nessler, R. A., Wilson, H. K., Al-Ahmad, A., Palecek, S. P., & Shusta, E. V. (2012) · Nature Biotechnology · doi:10.1038/nbt.2247 · Cited by 800
A cell culture model of the blood-brain barrier.
Rubin, L. L., Hall, D. E., Porter, S., Barbu, K., Cannon, C., Horner, H. C., Janatpour, M., Liaw, C. W., Manning, K., & Morales, J. (1991) · The Journal of cell biology · doi:10.1083/jcb.115.6.1725 · Cited by 765
Gut-on-a-Chip microenvironment induces human intestinal cells to undergo villus differentiation
Kim, H. J., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40126j · Cited by 750
Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739
A new blood–brain barrier model using primary rat brain endothelial cells, pericytes and astrocytes
Nakagawa, S., Deli, M. A., Kawaguchi, H., Shimizudani, T., Shimono, T., Kittel, Á., Tanaka, K., & Niwa, M. (2009) · Neurochemistry International · doi:10.1016/j.neuint.2008.12.002 · Cited by 728
The influence of cytokines on the integrity of the blood-brain barrier in vitro
de Vries, H. E., Blom-Roosemalen, M. C. M., Oosten, M. V., de Boer, A. G., van Berkel, T. J. C., Breimer, D. D., & Kuiper, J. (1996) · Journal of Neuroimmunology · doi:10.1016/0165-5728(95)00148-4 · Cited by 665
An Easier, Reproducible, and Mass‐Production Method to Study the Blood–Brain Barrier In Vitro
Dehouck, M., Méresse, S., Delorme, P., Fruchart, J., & Cecchelli, R. (1990) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1990.tb01236.x · Cited by 547
Research works printed but not linked: 3
- Jiang, 2012, Int. J. Alzheimer's Dis., 2012, 109324
- Zhou, 2013, Biomed. Environ. Sci., 26, 128
- Blume, 2010, Pharmazie, 1, 19
Cited by
Items 101–200 of 208
Wang, L., Wu, J., Chen, J., Dou, W., Zhao, Q., Han, J., Liu, J., Su, W., Li, A., Liu, P., et al. (2021) · Talanta · doi:10.1016/j.talanta.2021.122097 · Cited by 29
“This technique has been used to detect the barrier properties of the cell layer [173 – 175], which was related to tight junctions.”
MethodOrgans‐on‐Chips: Trends and Challenges in Advanced Systems Integration
Mughal, S., López‐Muñoz, G. A., Fernández‐Costa, J. M., Cortés-Reséndiz, A., Chiara, F. D., & Ramón‐Azcón, J. (2022) · Advanced Materials Interfaces · doi:10.1002/admi.202201618 · Cited by 30
Advances of microfluidic intestine-on-a-chip for analyzing anti-inflammation of food
Liang, D., Su, W., & Tan, M. (2021) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2021.1875395 · Cited by 27
Ugodnikov, A., Persson, H., & Simmons, C. A. (2024) · Lab on a Chip · doi:10.1039/d3lc01027a · Cited by 32
Environmental Toxicology Assays Using Organ-on-Chip
Akarapipad, P., Kaarj, K., Liang, Y., & Yoon, J. (2021) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-091620-091335 · Cited by 29
Imaging therapeutic peptide transport across intestinal barriers
Larsen, J. B., Taebnia, N., Dolatshahi‐Pirouz, A., Eriksen, A. Z., Hjørringgaard, C. U., Kristensen, K., Larsen, N. W., Larsen, N. B., Marie, R., Mündler, A.-K., et al. (2021) · RSC Chemical Biology · doi:10.1039/d1cb00024a · Cited by 28
Fernandes, J. T. S., Karra, N., Bowring, J., Reale, R., James, J., Blume, C., Pell, T. J., Rowan, W. C., Davies, D. E., Swindle, E. J., et al. (2022) · Lab on a Chip · doi:10.1039/d1lc01046h · Cited by 27
Kurth, F., Györvary, E., Heub, S., Ledroit, D., Paoletti, S., Renggli, K., Revol, V., Verhulsel, M., Weder, G., & Loizeau, F. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817202-5.00003-6 · Cited by 31
Finite element modeling to analyze TEER values across silicon nanomembranes
Khire, T. S., Nehilla, B. J., Getpreecharsawas, J., Gracheva, M. E., Waugh, R. E., & McGrath, J. L. (2018) · Biomedical Microdevices · doi:10.1007/s10544-017-0251-7 · Cited by 25
“The past decade witnessed a growth in the use of microfluidic systems as barrier tissue models (Vogel et al. 2011; Douville et al. 2010; Booth and Kim 2012; Booth et al. 2014; Walter et al. 2016; Ferrell et al. 2010; ávan der Meer et al. 2015; Henry et al. 2017; Wang et al. 2017).”
Chen, L.-J., Raut, B., Nagai, N., Abe, T., & Kaji, H. (2020) · Micromachines · doi:10.3390/mi11010079 · Cited by 25
“[22], while some measured the TEER of cells cultured in long microchannels [23,24].”
BackgroundGiampetruzzi, L., Blasi, L., Barca, A., Sciurti, E., Verri, T., Casino, F., Siciliano, P. A., & Francioso, L. N. (2022) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2022.100512 · Cited by 24
“The Trans-Epithelial Electrical Resistance (TEER) measurement is an important non-invasive method for monitoring the integrity of the epithelial monolayer and the permeability variations due to damage/ disruption of the epithelial cell barrier [11,12].”
Construction of cancer-on-a-chip for drug screening
Liu, Y., Yang, Q., Zhang, H., Han, S., Liu, N., Ren, H. J., Guo, H., & Xu, F. (2021) · Drug Discovery Today · doi:10.1016/j.drudis.2021.03.006 · Cited by 22
Technological advances for analyzing the content of organ-on-a-chip by mass spectrometry
Hadavi, D., Tosheva, I., Siegel, T. P., Cuypers, E., & Honing, M. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1197760 · Cited by 23
“tried to implement TEER in OOC analysis, which revealed that the obtained results from OOC are comparable to transwell systems (Figure 1C) (Odijk et al., 2015).”
BackgroundResultYuan, S., Yuan, H., Hay, D. C., Hu, H., & Wang, C. (2024) · Biosensors · doi:10.3390/bios14090425 · Cited by 26
A sustainable strategy for generating highly stable human skin equivalents based on fish collagen
Tan, S. H., Liu, S., Teoh, S. H., Bonnard, C., Leavesley, D. I., & Liang, K. (2024) · Biomaterials Advances · doi:10.1016/j.bioadv.2024.213780 · Cited by 21
Carius, P., Dubois, A., Ajdarirad, M., Artzy‐Schnirman, A., Sznitman, J., Schneider‐Daum, N., & Lehr, C. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.743236 · Cited by 19
“This holds still true while some more advanced bioelectrical methods (e.g., impedance spectroscopy) might be more precise in determining information about actual barrier integrity (Günzel et al., 2012; Odijk et al., 2015; Srinivasan et al., 2015; Henry et al., 2017).”
BackgroundJabbar, F., Kim, Y., & Lee, S. H. (2022) · BioChip Journal · doi:10.1007/s13206-022-00068-x · Cited by 19
Nair, A. L., Mesch, L., Schulz, I., Becker, H., Raible, J., Kiessling, H., Werner, S., Rothbauer, U., Schmees, C., Busche, M., et al. (2021) · Biosensors · doi:10.3390/bios11090314 · Cited by 20
“The resistance is very sensitive towards even minor ion leaks [2,58] (Figure A3).”
BackgroundDevelopment of Organs-on-Chips and Their Impact on Precision Medicine and Advanced System Simulation
Luo, Y., Li, X., Zhao, Y., Zhong, W., Xing, M. M. Q., & Lyu, G. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15082094 · Cited by 18
Nanotechnologies in Obstetrics and Cancer during Pregnancy: A Narrative Review
Bertozzi, S., Corradetti, B., Seriau, L., Nanez, J. A. D., Cedolini, C., Fruscalzo, A., Cesselli, D., Cagnacci, A., & Londero, A. P. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm12081324 · Cited by 18
“Measuring TEER across a barrier is a non-destructive real-time method to assess barrier integrity [50].”
MethodSemaglutide Aggregates into Oligomeric Micelles and Short Fibrils in Aqueous Solution
Hamley, I. W., de Mello, L. R., Castelletto, V., Zinn, T., Cowieson, N. P., Seitsonen, J. J. T., & Bizien, T. (2025) · Biomacromolecules · doi:10.1021/acs.biomac.5c00342 · Cited by 16
Microfluidic strategies for the blood-brain barrier construction and assessment
Yin, F., Su, W., Wang, L., & Hu, Q. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116689 · Cited by 16
Spitz, S., Schobesberger, S., Brandauer, K., & Ertl, P. (2023) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10604 · Cited by 20
Gouveia, Z., Özkan, A., Giannobile, W. V., Santerre, J. P., & Wu, D. T. S. (2025) · Bioengineering & Translational Medicine · doi:10.1002/btm2.70020 · Cited by 15
“111,112 In DOC, as an expansion of oral mucosal organoids, oral mucosa on-chip models have been developed to explore the microbiological impact on oral soft tissues towards a better understanding of mucositis and periodontitis.”
Raut, B., Chen, L.-J., Hori, T., & Kaji, H. (2021) · Micromachines · doi:10.3390/mi12030282 · Cited by 15
“Also, (i) temperature change and (ii) movement of electrode during medium replacement process affects the TEER reading afterwards which adds a big challenge to the TEER measurement process [28,29].”
BackgroundBioinspired Engineering of Organ-on-Chip Devices
Wang, L., Li, Z., Xu, C., & Qin, J. (2019) · Advances in experimental medicine and biology · doi:10.1007/978-981-13-9791-2_13 · Cited by 14
Choi, J., Mathew, S., Oerter, S., Appelt‐Menzel, A., Hansmann, J., & Schmitz, T. (2022) · Bioengineering · doi:10.3390/bioengineering9010039 · Cited by 16
“Barrier integrity and quality of in vitro models can be efficiently quantified by non-invasive measurement of TEER-based techniques without interfering with cellular functionality [9,11,12].”
BackgroundBioengineered human gut-on-a-chip for advancing non-clinical pharmaco-toxicology
Shin, Y. C., Than, N., Park, S. J., & Kim, H. J. (2024) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1080/17425255.2024.2365254 · Cited by 14
“Also, elec-trode-embedded microfluidic devices have been suggested to monitor trans-epithelial electrical resistance (TEER) in real-time for evaluating epithelial barrier function [113–116].”
Qiu, B., Pompe, S., Xenaki, K. T., Maggio, A. D., Henegouwen, P. M. P. V. B. E., Oliveira, S., Mastrobattista, E., & Caiazzo, M. (2025) · Journal of Controlled Release · doi:10.1016/j.jconrel.2025.114257 · Cited by 15
Guarino, V., Perrone, E., Luca, E. D., Rainer, A., Cesaria, M., Zizzari, A. T., Bianco, M., Gigli, G., Moroni, L., & Arima, V. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202401804 · Cited by 11
Miyazaki, T., Hirai, Y., Kamei, K., Tsuchiya, T., & Tabata, O. (2020) · Electronics and Communications in Japan · doi:10.1002/ecj.12296 · Cited by 11
In vitro electrochemical assays for vascular cells and organs
Utagawa, Y., Hiramoto, K., Nashimoto, Y., Ino, K., & Shiku, H. (2021) · Electrochemical Science Advances · doi:10.1002/elsa.202100089 · Cited by 10
Recent advances and future prospects of functional organ-on-a-chip systems
Moghaddam, A. S., Moghaddam, Z. S., Davachi, S. M., Sarikhani, E., Mahand, S. N., Khonakdar, H. A., Bagher, Z., & Ashammakhi, N. A. (2022) · Materials Chemistry Frontiers · doi:10.1039/d2qm00072e · Cited by 9
Liu, J., Zhao, W., Qin, M., Luan, X., Li, Y., Zhao, Y., Huang, C., Zhang, L., & Li, M. (2022) · The Analyst · doi:10.1039/d2an01931k · Cited by 11
Xiang, X., Wang, X., Shang, Y., & Ding, Y. (2023) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2023.03.006 · Cited by 11
Bouges, E., Segers, C., Leys, N., Lebeer, S., Zhang, J., & Mastroleo, F. (2023) · Cancers · doi:10.3390/cancers15245859 · Cited by 9
“…cells with bacteria [138,139], the modeling of cancer [140,141], drug discovery with toxicity tests [142], and the study of the barrier function [143]. representation of in vitro radiotherapy [5], the co-culture of epithelial cells with bacteria [138,139], the modeling of cancer [140,141], drug…”
BackgroundA comprehensive review on organ-on-chips as powerful preclinical models to study tissue barriers
Filiz, Y., Esposito, A., Maria, C. D., Vozzi, G., & Yeşil-Çeliktaş, Ö. (2024) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ad776c · Cited by 13
“The resistance can be calculated by TEER sensors to offer a quantitative evaluation of the barrier integrity [107].”
Organs-on-Chips: How Microsystems Technology Can Transform the Drug Development Process
Borenstein, J. T. (2016) · IEEE Pulse · doi:10.1109/mpul.2015.2513722 · Cited by 9
“Recent efforts point out that TEER measurements in microfluidic systems present specific challenges [6] and are highly sensitive to small changes in the confluence of cells cultured on barrier membranes.”
BackgroundStandard: human intestine-on-a-chip
Liu, H., Wang, Y., Zhang, X., Zhang, M., Wang, P., Shang, J., Li, Z., Gong, L., Guo, J., Sun, W., et al. (2024) · Cell Regeneration · doi:10.1186/s13619-024-00198-7 · Cited by 9
Takata, Y., Sadeghian, R. B., Fujimoto, K., & Yokokawa, R. (2024) · The Analyst · doi:10.1039/d4an00267a · Cited by 8
Ugodnikov, A., Lu, J., Yechuri, B., Chebotarev, O., Takeuchi, L. E., & Simmons, C. A. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c05113 · Cited by 9
An ischemic stroke-on-a-chip model integrated with machine learning for screening of drug candidates
Liu, J., Wang, P., Lian, P., & Qin, J. (2025) · Lab on a Chip · doi:10.1039/d5lc00517e · Cited by 9
State of the Art in Integrated Biosensors for Organ-on-a-Chip Applications
Dey, T., Mitra, P., Chakraborty, B., Sanyal, A., Acharjee, A., Ghosh, A., & Mandal, D. (2024) · Smart nanomaterials technology · doi:10.1007/978-981-99-6597-7_10 · Cited by 9
Early Detection of Nephrotoxicity In Vitro Using a Transparent Conducting Polymer Device
Huerta, M., Rivnay, J., Ramuz, M. P., Hama, A., & Owens, R. M. (2016) · Applied In Vitro Toxicology · doi:10.1089/aivt.2015.0028 · Cited by 7
van der Helm, M. W., Odijk, M., Frimat, J., van der Meer, A. D., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I. (2017) · Journal of Visualized Experiments · doi:10.3791/56334-v · Cited by 7
Shi, Y., Sun, S., Liu, H., Zhao, M., Qin, M., Liu, J., Hu, J., Zhao, Y., Li, M., Zhang, L., et al. (2024) · Lab on a Chip · doi:10.1039/d4lc00817k · Cited by 6
Costa, S. D. F. Z., Carneiro, A. B., Lebre, F., Meneses, J., Ainla, A., Moura, C., Alfaro‐Moreno, E., & Ribeiro, A. R. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202502518 · Cited by 7
Qiao, L., Chang, S., Zou, L., Zhang, F., Cui, C., & Huang, N. (2025) · Bio-Design and Manufacturing · doi:10.1631/bdm.2500076 · Cited by 7
“TEER is often used to evaluate the barrier function of models, such as the gut [87], lung [88], and blood–brain barrier (BBB) [89].”
Chacón, M., Vázquez, N., Alonso‐Alonso, S., Persinal-Medina, M., Llames, S. G., Pevida, M., Alcalde, I., Merayo‐Lloves, J., & Meana, Á. (2023) · Biosensors · doi:10.3390/bios13020162 · Cited by 6
Li, Y., Xu, M., Zhu, Z., Xu, F., & Chen, B. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1236610 · Cited by 7
Yan, L., Dwiggins, C. W., Gupta, U., & Stroka, K. M. (2023) · Bioengineering · doi:10.3390/bioengineering10091080 · Cited by 8
“…resistance (TEER) is utilized for in vitro barrier function evaluation [49], but this technique does not easily translate to 3D microvessels since the measurement of TEER from the ends of a long channel is challenging and the long electrodes are required in both luminal and abluminal spaces [50].”
Bioengineering and regeneration of gastrointestinal tissue: where are we now and what comes next?
Zakhem, E., Raghavan, S. A., Suhar, R. A., & Bitar, K. N. (2019) · Expert Opinion on Biological Therapy · doi:10.1080/14712598.2019.1595579 · Cited by 7
In-Situ Measurements of the Physiological Parameters in Lab-on-Chip Systems
Bakhchova, L., & Steinmann, U. (2022) · tm - Technisches Messen · doi:10.1515/teme-2022-0063 · Cited by 6
Ugodnikov, A., Chebotarev, O., Persson, H., & Simmons, C. A. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.3c01898 · Cited by 10
Transendothelial electrical resistance (TEER) measurement system of 3D tubular vascular channel
Mori, N., Morimoto, Y., & Takeuchi, S. (2018) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2018.8346551 · Cited by 7
Robust fluidic connections to freestanding microfluidic hydrogels
Faley, S. L., Baer, B. B., Larsen, T. S. H., & Bellan, L. M. (2015) · Biomicrofluidics · doi:10.1063/1.4921453 · Cited by 5
Online, label-free monitoring of organ-on-a-chip models: The case for microphysiometry
Alexander, F. A., & Wiest, J. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320026 · Cited by 6
Molins, B., Mesquida, M., & Adán, A. (2022) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2022.101097 · Cited by 6
RetractedTransducer Systems Integrated into Organ‐on‐a‐Chip Devices: From Detection to Fabrication
Ferreira, G. M., Sousa, P. C., Catarino, S. O., & Minas, G. M. H. (2025) · Small · doi:10.1002/smll.202510425 · Cited by 9
Sissoko, C. A., Spitz, S., Zhang, Z., Abedi, K., Kamm, R. D., & Barrile, R. (2026) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2026.115881 · Cited by 9
Chitosan and Trimethyl Chitosan (TMC) as Drug Absorption Enhancers
Benediktsdóttir, B. E. (2020) · Encyclopedia of Marine Biotechnology · doi:10.1002/9781119143802.ch123 · Cited by 4
Joshi, T., Chan, Y. O., Qiao, Z., Kheirandish, L., Gozal, D., & Khalyfa, A. (2025) · Experimental Neurology · doi:10.1016/j.expneurol.2025.115188 · Cited by 3
Miyazaki, T., Hirai, Y., Kamei, K., Tsuchiya, T., & Tabata, O. (2021) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.141.237 · Cited by 3
Application of Organ-on-Chip in Blood Brain Barrier Model
Vatsa, P., & Pant, A. B. (2022) · Springer eBooks · doi:10.1007/978-981-19-1379-2_24 · Cited by 3
Highly Accurate Measurement of Trans-Epithelial Electrical Resistance in Organ-on-a-Chip
Miyazaki, T., Yang, J., Imamura, S., Hirai, Y., Kamei, K., Tsuchiya, T., & Tabata, O. (2021) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems51782.2021.9375164 · Cited by 3
Kaden, T., Besser, S., Abdo, N., Mosig, A. S., Rennert, K., & Nietzsche, S. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.04.10.648170 · Cited by 2
“TEER measurement has been developed as a pivotal technique for assessing barrier integrity in OoC systems in real-time [6,7].”
Ahn, H., Min, J., Park, W., Park, S., Lee, Y., Lee, J., Shin, W., Jeon, N. L., Bang, S., Ko, J., et al. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202502113 · Cited by 4
“Several studies have integrated electrodes into microfluidic systems to enable real-time TEER measurements, advancing the field of functional barrier assessment [12–15].”
Jeong, M., Park, K., Jung, D., Shin, S., Lee, J., Ko, J., Bang, S., & Ahn, J. (2026) · Materials Today Bio · doi:10.1016/j.mtbio.2026.103050 · Cited by 2
“Additionally, compared to standardized membranes, lateral configurations complicate trans-epithelial electrical resistance (TEER) measurements because of electrode placement and non-uniform current distribution [129].”
Nkwagatse, T., & Sturm, A. W. (2021) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-021-04226-1 · Cited by 2
Spivey, E. C., Yin, J., Chaum, E., & Wikswo, J. P. (2023) · Translational Vision Science & Technology · doi:10.1167/tvst.12.11.28 · Cited by 2
Gut‐on‐chip with integrated sensors: Enables in‐situ monitoring and real‐time evaluation of the chip
Li, Y., Xiang, Z., Yuan, Z., Zhang, H., & Shi, A. (2024) · Electroanalysis · doi:10.1002/elan.202400188 · Cited by 2
Lattanzi, D., Montesi, L., Sartini, A., & Rauti, R. (2025) · Sensors and Actuators Reports · doi:10.1016/j.snr.2025.100334 · Cited by 2
Miyazaki, T., Hirai, Y., Kamei, K., Tsuchiya, T., & Tabata, O. (2020) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.140.285 · Cited by 2
Petrov, V. A., Gerasimenko, T. N., Kindeeva, O. V., Gazizov, I. N., Shilin, S. A., & Sakharov, D. A. (2020) · Bulletin of the Russian Academy of Sciences Physics · doi:10.3103/s1062873820020288 · Cited by 2
Skin-on-a-Chip Microfluidic Devices: Production, Verification, and Uses in Cosmetic Toxicology
Mistry, K., & Alexander, M. H. (2023) · Springer eBooks · doi:10.1007/978-981-99-2804-0_4 · Cited by 3
Physiological oxygen measurements in vitro-Schrödinger’s cat in 3D cell biology
Gottwald, E., Grün, C., Nies, C., & Liebsch, G. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1218957 · Cited by 2
Barin, N., Chowdhury, S. Z., de Wit, M., Head, R., Bals, K., Brosens, E., van Luijn, M. M., Balcioglu, H. E., Accardo, A., & French, P. J. (2026) · Advanced Materials Technologies · doi:10.1002/admt.202502614 · Cited by 2
“…flow, key functional validations remain to be assessed, including assessments of basal lamina formation, [ 15, 82 ] vessel permeability [ 39, 81, 83, 84 ], and transendothelial electrical resistance (TEER) [ 83, 85–87 ], which are critical to fully establishing barrier integrity and functionality.”
Stoeger, V., Strauß, M. E., Thurimella, K., Elias‐Kirma, S., Niewczas, I. S., Parlar, E., Schaudy, E., Moysidou, C., Voong, S., Lietard, J., et al. (2026) · Advanced Biology · doi:10.1002/adbi.202500409 · Cited by 1
“As demonstrated in previous studies by other research groups [ 26, 60 ], as well as in the present study, higher baseline TEER values were detected in the GoC (28.2 k Ω * cm 2 ) compared to static cell culture inserts, which were around 3x less after 12 days in culture [ 67 ].”
InfluentialGupta, P., Gupta, E., Jain, R., & Dandekar, P. P. (2026) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2026.115941 · Cited by 1
Ugodnikov, A., Lu, J., Chebotarev, O., & Simmons, C. A. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.11.25.568615 · Cited by 2
Development of microelectrodes for electrical measurements in a microfluidic system
Thomée, E. (2017) · Lund University Publications Student Papers (Lund University)
van der Helm, M. W., Henry, O., Hamkins-Indik, T., Cronce, M. J., Leineweber, W. D., Odijk, M., van der Meer, A. D., Eijkel, J. C. T., Ingber, D. E., van den Berg, A., et al. (2017) · University of Twente Research Information
Stabilization of Hypoxia Inducible Factor by Cobalt Chloride Can Alter Renal Transepithelial
Nag, S. (2018) · EngagedScholarship @ Cleveland State University (Cleveland State University)
Sadighi, A. (2018) · Digital Commons - URI (University of Rhode Island) · doi:10.23860/diss-sadighi-armin-2018 · Cited by 1
Yamada, T., Nie, M., Shima, A., Morimoto, Y., & Takeuchi, S. (2020) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems46641.2020.9056109
“Transendothelial electrical resistance (TEER) is an indicator of barrier integrity which could be measured in a non-invasive and real-time method [1-4].”
BackgroundTakata, Y., Ueno, R., Sadeghian, R. B., Liu, Y., Naganuma, K., Tsuji, K., & Yokokawa, R. (2020) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems46641.2020.9056424
Monden, Y., Tsukamoto, A., Ushida, T., Kobayashi, E., Nakagawa, K., & Sakuma, I. (2020) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-020-02207-8 · Cited by 1
Nkwagatse, T. (2019) · ResearchSpace (University of KwaZulu-Natal)
Recapitulation of Particulate matter Effected Human Alveolus on Chip Inflammatory ResponsesPreprint
Jabbar, F., Kim, Y. S., Soomro, A. M., Asif, A., Cho, Y., Choi, K.-H., & Ho, L. S. (2020) · doi:10.21203/rs.2.22193/v1
“TEER electrode location also significantly change in TEER values in these cultures, mathematical models can help to reduce these variations(14, 18, 19) Therefore successful fabrication of a robust on-chip TEER sensing capability enabled us to measure barrier function electrochemically.”
BackgroundTrennheuser, S., Schmitt-Hoffner, F., Mahringer, A., Mesch, L., Jones, P., Stelzle, M., & Fricker, G. (2020) · doi:10.21203/rs.3.rs-100206/v1
“It has been reported that even minimal gaps in cell layers could lead to drastically reduced TEER values [47].”
BackgroundLee, W., Lyu, Z., Park, J., Kim, K.-M., Jin, H.-J., Wu, H., Rajadas, J., Kim, D., & Steinberg, G. K. (2021) · Research Square · doi:10.21203/rs.3.rs-96280/v1
Microfabricated Systems for Cardiovascular Tissue Modeling
Knee‐Walden, E. J., Wagner, K. T., Wu, Q., Rafatian, N., & Radisic, M. (2022) · Springer eBooks · doi:10.1007/978-3-030-86140-7_10
The artificial gut : integrating in vitro models of the human digestive tract with mass spectrometry
Santbergen, M. J. C. (2020) · doi:10.18174/532696
Measurement and analytical techniques
Grochala, D., Paleczek, A., López‐Muñoz, G. A., & Rydosz, A. M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15384-6.00003-3
Research Progress in the Treatment of Diabetic Nephropathy Based on Intestinal Microecology
纪, 新. (2024) · Hans Journal of Biomedicine · doi:10.12677/hjbm.2024.141009
On-chip Sensing Technique; Measuring Barrier Function of Cell Layer
MIYAZAKI, T., & Hirai, Y. (2024) · The Journal of the Institute of Electrical Engineers of Japan · doi:10.1541/ieejjournal.144.202
Multiorgans-on-a-chip for subacute toxicity
Chiome, T. J., M.V.S.S.T., S. R., & Srinivasan, A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13782-2.00021-8
Recent breakthrough in organ-on-a-chip
Mukherjee, A. G., Wanjari, U. R., Bradu, P., Biswas, A., Patil, M., Renu, K., Vellingiri, B., & Gopalakrishnan, A. V. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13782-2.00007-3
Metadata
- Authors
- Odijk, M., van der Meer, A. D., Levner, D., Kim, H. J., van der Helm, M. W., Segerink, L. I., Frimat, J.-P., Hamilton, G. A., Ingber, D. E., & van den Berg, A.
- Affiliations
- University of Twente (NL)
- Wyss Institute for Biologically Inspired Engineering at Harvard University
- Harvard University (US)
- BIOS/Lab-on-Chip Group
- Corresponding author
- Odijk, Mathieu
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 15
- Issue
- 3
- Pages
- 745-752
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2145376030
- Cited by
- 209
- References
- 71
- Citations by year
- 2026: 9 · 2025: 16 · 2024: 22 · 2023: 23 · 2022: 25 · 2021: 30 · 2020: 25 · 2019: 15 · 2018: 15 · 2017: 15 · 2016: 9 · 2015: 5
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- green
- research.utwente.nl
- Licence
- other-oa
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- University of Twente Research Information (publishedVersion, other-oa)
- Radboud Repository (Radboud University) (submittedVersion)
- University of Twente Research Information (submittedVersion)
- Funders
- Defense Advanced Research Projects Agency (W911NF-12-2-0036)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
- Keywords
- transepithelial electrical resistance, organ-on-a-chip, gut-on-a-chip, microfluidics, transwell system, epithelial barrier function, measurement reproducibility
- MeSH terms
- Cells, Cultured, Humans, Electric Impedance, Caco-2 Cells, Endothelial Cells, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.