Measuring direct current trans-epithelial electrical resistance in organ-on-a-chip microsystems
Open accessThe DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
Trans-epithelial electrical resistance (TEER) measurements are widely used as real-time, non-destructive, and label-free measurements of epithelial and endothelial barrier function. TEER measurements are ideal for characterizing tissue barrier function in organs-on-chip studies for drug testing and investigation of human disease models; however, published reports using this technique have reported highly conflicting results even with identical cell lines and experimental setups. The differences are even more dramatic when comparing measurements in conventional Transwell systems with those obtained in microfluidic systems. Our goal in this work was therefore to enhance the fidelity of TEER measurements in microfluidic organs-on-chips, specifically using direct current (DC) measurements of TEER, as this is the most widely used method reported in the literature. Here we present a mathematical model that accounts for differences measured in TEER between microfluidic chips and Transwell systems, which arise from differences in device geometry. The model is validated by comparing TEER measurements obtained in a microfluidic gut-on-a-chip device versus in a Transwell culture system. Moreover, we show that even small gaps in cell coverage (e.g., 0.4%) are sufficient to cause a significant (~80%) drop in TEER. Importantly, these findings demonstrate that TEER measurements obtained in microfluidic systems, such as organs-on-chips, require special consideration, specifically when results are to be compared with measurements obtained from Transwell systems.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Astrocyte-endothelial interactions at the blood-brain barrier
Abbott, N. J., Rönnbäck, L., & Hansson, E. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1824 · Cited by 5,595
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationKim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Self-citationDerivation of blood-brain barrier endothelial cells from human pluripotent stem cells
Lippmann, E. S., Azarin, S. M., Kay, J. E., Nessler, R. A., Wilson, H. K., Al-Ahmad, A., Palecek, S. P., & Shusta, E. V. (2012) · Nature Biotechnology · doi:10.1038/nbt.2247 · Cited by 800
A cell culture model of the blood-brain barrier.
Rubin, L. L., Hall, D. E., Porter, S., Barbu, K., Cannon, C., Horner, H. C., Janatpour, M., Liaw, C. W., Manning, K., & Morales, J. (1991) · The Journal of cell biology · doi:10.1083/jcb.115.6.1725 · Cited by 765
Gut-on-a-Chip microenvironment induces human intestinal cells to undergo villus differentiation
Kim, H. J., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40126j · Cited by 750
Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739
A new blood–brain barrier model using primary rat brain endothelial cells, pericytes and astrocytes
Nakagawa, S., Deli, M. A., Kawaguchi, H., Shimizudani, T., Shimono, T., Kittel, Á., Tanaka, K., & Niwa, M. (2009) · Neurochemistry International · doi:10.1016/j.neuint.2008.12.002 · Cited by 728
The influence of cytokines on the integrity of the blood-brain barrier in vitro
de Vries, H. E., Blom-Roosemalen, M. C. M., Oosten, M. V., de Boer, A. G., van Berkel, T. J. C., Breimer, D. D., & Kuiper, J. (1996) · Journal of Neuroimmunology · doi:10.1016/0165-5728(95)00148-4 · Cited by 665
An Easier, Reproducible, and Mass‐Production Method to Study the Blood–Brain Barrier In Vitro
Dehouck, M., Méresse, S., Delorme, P., Fruchart, J., & Cecchelli, R. (1990) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1990.tb01236.x · Cited by 547
Research works printed but not linked: 3
- Jiang, 2012, Int. J. Alzheimer's Dis., 2012, 109324
- Zhou, 2013, Biomed. Environ. Sci., 26, 128
- Blume, 2010, Pharmazie, 1, 19
Cited by
Human organs-on-chips for disease modelling, drug development and personalized medicine
Ingber, D. E. (2022) · Nature Reviews Genetics · doi:10.1038/s41576-022-00466-9 · Cited by 1,589
Self-citationAdvances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
A microfluidics-based in vitro model of the gastrointestinal human–microbe interface
Shah, P., Fritz, J. V., Glaab, E., Desai, M. S., Greenhalgh, K., Frachet, A., Niegowska, M., Estes, M., Jäger, C., Seguin-Devaux, C., et al. (2016) · Nature Communications · doi:10.1038/ncomms11535 · Cited by 660
Microfluidic Organ-on-a-Chip Models of Human Intestine
Bein, A., Shin, W., Jalili-Firoozinezhad, S., Park, M. H., Sontheimer-Phelps, A., Tovaglieri, A., Chalkiadaki, A., Kim, H. J., & Ingber, D. E. (2018) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2017.12.010 · Cited by 625
Henry, O. Y. F., Villenave, R., Cronce, M. J., Leineweber, W. D., Benz, M. A., & Ingber, D. E. (2017) · Lab on a Chip · doi:10.1039/c7lc00155j · Cited by 482
Self-citationBrown, J. A., Pensabene, V., Markov, D. A., Allwardt, V., Neely, M. D., Shi, M., Britt, C. M., Hoilett, O. S., Yang, Q., Brewer, B. M., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4934713 · Cited by 410
Ahn, S. I., Sei, Y. J., Park, H.-J., Kim, J., Ryu, Y., Choi, J. J., Sung, H.-J., MacDonald, T. J., Levey, A. I., & Kim, Y. (2020) · Nature Communications · doi:10.1038/s41467-019-13896-7 · Cited by 402
Kidney-on-a-Chip technology for drug-induced nephrotoxicity screening
Wilmer, M. J., Ng, C. P., Lanz, H. L., Vulto, P., Suter-Dick, L., & Masereeuw, R. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.11.001 · Cited by 354
Microfluidic organ-on-chip technology for blood-brain barrier research
van der Helm, M. W., van der Meer, A. D., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I. (2016) · Tissue Barriers · doi:10.1080/21688370.2016.1142493 · Cited by 333
“This can be corrected with the mathematical model presented in this publication.(53) Measuring TEER with impedance spectroscopy (using alternating currents; AC) is preferred over measuring the ohmic resistance with DC.”
BackgroundMethodOrgan-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Ingber, D. E. (2020) · Advanced Science · doi:10.1002/advs.202002030 · Cited by 277
Maoz, B. M., Herland, A., Henry, O. Y. F., Leineweber, W. D., Yadid, M., Doyle, J., Mannix, R., Kujala, V. J., FitzGerald, E. A., Parker, K. K., et al. (2017) · Lab on a Chip · doi:10.1039/c7lc00412e · Cited by 266
Self-citationGut-on-a-chip: Current progress and future opportunities
Ashammakhi, N., Nasiri, R., Barros, N. R. D., Tebon, P., Thakor, J., Goudie, M., Shamloo, A., Martin, M. G., & Khademhosseini, A. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120196 · Cited by 235
Fuchs, S., Johansson, S., Tjell, A. Ø., Werr, G., Mayr, T., & Tenje, M. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c01110 · Cited by 213
Medium throughput breathing human primary cell alveolus-on-chip model
Stucki, J. D., Hobi, N., Galimov, A., Stucki, A. O., Schneider-Daum, N., Lehr, C.-M., Huwer, H., Frick, M., Funke-Chambour, M., Geiser, T., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-32523-x · Cited by 190
Development of a Gut-on-a-Chip Model for High Throughput Disease Modeling and Drug Discovery
Beaurivage, C., Naumovska, E., Chang, Y., Elstak, E., Nicolas, A., Wouters, H., van Moolenbroek, G., Lanz, H., Trietsch, S., Joore, J., et al. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20225661 · Cited by 185
Blundell, C., Yi, Y., Ma, L., Tess, E. R., Farrell, M. J., Georgescu, A., Aleksunes, L. M., & Huh, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700786 · Cited by 178
Kim, J., Lee, K.-T., Lee, J. S., Shin, J., Cui, B., Yang, K., Choi, Y. S., Choi, N., Lee, S. H., Lee, J.-H., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00743-8 · Cited by 172
Yuan, L., van der Mei, H. C., Busscher, H. J., & Peterson, B. W. (2020) · Frontiers in Microbiology · doi:10.3389/fmicb.2020.599555 · Cited by 165
“These serial resistances operate in parallel with the resistance of the extra-cellular fluid contained in the tight-junctions (Suzuki et al., 2017) between cells (the para-cellular pathway) (Benson et al., 2013; Odijk et al., 2015).”
BackgroundResultUse of porous membranes in tissue barrier and co-culture models
Chung, H. H., Mireles, M., Kwarta, B. J., & Gaborski, T. R. (2018) · Lab on a Chip · doi:10.1039/c7lc01248a · Cited by 161
Cochrane, A., Albers, H. J., Passier, R., Mummery, C. L., van den Berg, A., Orlova, V. V., & van der Meer, A. D. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.06.007 · Cited by 162
“Such comparisons can only be achieved by developing objective, quantitative endpoints, as recently carried out with measurements of TEER that allow comparison between microfluidic chips with other in vitro assays [106], andwithmeasurements of pro-inflammatory cyto-”
Backgroundvan der Helm, M. W., Henry, O. Y. F., Bein, A., Hamkins-Indik, T., Cronce, M. J., Leineweber, W. D., Odijk, M., van der Meer, A. D., Eijkel, J. C. T., Ingber, D. E., et al. (2019) · Lab on a Chip · doi:10.1039/c8lc00129d · Cited by 161
Ferrari, E., Palma, C., Vesentini, S., Occhetta, P., & Rasponi, M. (2020) · Biosensors · doi:10.3390/bios10090110 · Cited by 172
Direct quantification of transendothelial electrical resistance in organs-on-chips
van der Helm, M. W., Odijk, M., Frimat, J., van der Meer, A. D., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.06.014 · Cited by 156
Lind, J. U., Yadid, M., Perkins, I., O'Connor, B. B., Eweje, F., Chantre, C. O., Hemphill, M. A., Yuan, H., Campbell, P. H., Vlassak, J. J., et al. (2017) · Lab Chip · doi:10.1039/c7lc00740j · Cited by 148
Lyu, Z., Park, J., Kim, K., Jin, H.-J., Wu, H., Rajadas, J., Kim, D., Steinberg, G. K., & Lee, W. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00744-7 · Cited by 164
A multi-chamber microfluidic intestinal barrier model using Caco-2 cells for drug transport studies
Tan, H.-Y., Trier, S., Rahbek, U. L., Dufva, M., Kutter, J. P., & Andresen, T. L. (2018) · PLOS ONE · doi:10.1371/journal.pone.0197101 · Cited by 143
“To approach an equal potential drop over the entire membrane [64], the electrodes in the microfluidic device were embedded directly above and below the membrane.”
Drug Toxicity Evaluation Based on Organ-on-a-chip Technology: A Review
Cong, Y., Han, X., Wang, Y., Chen, Z., Lu, Y., Liu, T., Wu, Z., Jin, Y., Luo, Y., & Zhang, X. (2020) · Micromachines · doi:10.3390/mi11040381 · Cited by 140
“TEER (transendothelial resistance) [38] Biomarker of barrier functions √”
BackgroundBiology and Models of the Blood–Brain Barrier
Hajal, C., Le Roi, B., Kamm, R. D., & Maoz, B. M. (2021) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-082120-042814 · Cited by 137
“The results obtained in Transwell systems might not be representative of those in OoCs, however, and they are sometimes mathematically corrected, which can introduce a degree of error (99).”
BackgroundGut-on-a-chip: Mimicking and monitoring the human intestine
Marrero, D., Pujol‐Vila, F., Vera, D., Gabriel, G., Illa, X., Elizalde‐Torrent, A., Álvarez, M., & Villa, R. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113156 · Cited by 140
Vigh, J. P., Kincses, A., Ozgür, B., Walter, F. R., Santa-Maria, A. R., Valkai, S., Vastag, M., Neuhaus, W., Brodin, B., Dér, A., et al. (2021) · Micromachines · doi:10.3390/mi12060685 · Cited by 127
“In addition, the mobile electrodes (chopstick or chamber) are not suitable to measure TEER in specifically designed microchannel systems [16].”
BackgroundMethoddi Vito, R., Conte, C., & Traina, G. (2022) · Cells · doi:10.3390/cells11162617 · Cited by 120
“TJ strength regulates the epithelial permeability through the paracellular pathway [19,20], nutrient uptake, waste product clearance [21], intestinal homeostasis [22], and host defense against pathogen invasion [23].”
BackgroundMethodImpedance Spectroscopy as a Tool for Monitoring Performance in 3D Models of Epithelial Tissues
Gerasimenko, T. N., Nikulin, S. V., Захарова, Г. С., Poloznikov, A. A., Petrov, V., Baranova, A. V., & Tonevitsky, A. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00474 · Cited by 127
Rothbauer, M., Rosser, J. M., Zirath, H., & Ertl, P. (2018) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2018.08.009 · Cited by 110
“Until recently, on-chip monolayer cultures were predominantly used on membranes to investigate the physiology, integrity and function of human cell barriers using mostly cancer cell lines [17].”
BackgroundThe Gut–Organ-Axis Concept: Advances the Application of Gut-on-Chip Technology
Guo, Y., Chen, X., Gong, P., Li, G., Yao, W., & Yang, W. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24044089 · Cited by 115
“In general, animal models are the primary method for studying the gut and its associated diseases in vivo [19].”
BackgroundLiu, S., Kumari, S., He, H., Mishra, P., Singh, B. N., Singh, D., Liu, S., Srivastava, P., & Li, C. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115285 · Cited by 112
Recent Progress in Microfluidic Models of the Blood-Brain Barrier
Jiang, L., Li, S., Zheng, J., Li, Y., & Huang, H. (2019) · Micromachines · doi:10.3390/mi10060375 · Cited by 96
“Therefore, these parameters need to be kept constant during the measurement process [97].”
BackgroundOrgan‐On‐A‐Chip Models of the Blood–Brain Barrier: Recent Advances and Future Prospects
Kawakita, S., Mandal, K., Mou, L., Mecwan, M. M., Zhu, Y., Li, S., Sharma, S., Hernández, A. L., Nguyen, H. T., Maity, S., et al. (2022) · Small · doi:10.1002/smll.202201401 · Cited by 112
Nicolas, A., Schavemaker, F., Kosim, K., Kurek, D., Haarmans, M., Bulst, M., Lee, K., Wegner, S. V., Hankemeier, T., Joore, J., et al. (2021) · Lab on a Chip · doi:10.1039/d0lc00770f · Cited by 102
Yeste, J., García-Ramírez, M., Illa, X., Guimerà, A., Hernández, C., Simó, R., & Villa, R. (2018) · Lab on a Chip · doi:10.1039/c7lc00795g · Cited by 89
Kavand, H., Nasiri, R., & Herland, A. (2021) · Advanced Materials · doi:10.1002/adma.202107876 · Cited by 94
A microengineered Brain-Chip to model neuroinflammation in humans
Pediaditakis, I., Kodella, K. R., Manatakis, D. V., Le, C. Y., Barthakur, S., Sorets, A., Gravanis, A., Ewart, L., Rubin, L. L., Manolakos, E. S., et al. (2022) · iScience · doi:10.1016/j.isci.2022.104813 · Cited by 88
Engineering and monitoring cellular barrier models
Yeste, J., Illa, X., Álvarez, M., & Villa, R. (2018) · Journal of Biological Engineering · doi:10.1186/s13036-018-0108-5 · Cited by 100
Intestinal organ chips for disease modelling and personalized medicine
Özkan, A., LoGrande, N., Feitor, J. F., Goyal, G., & Ingber, D. E. (2024) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-024-00968-3 · Cited by 110
“Various sensor types, such as electrodes that enable real-time measurement of transepithelial electrical resistance (TEER) on-chip using direct current 108–110 or impedance spectroscopy, have also been integrated into gut chip devices 111 .”
Hickman, J. (2016) · Journal of Rare Diseases Research & Treatment · doi:10.29245/2572-9411/2016/3.1026 · Cited by 82
Barriers-on-chips: Measurement of barrier function of tissues in organs-on-chips
Arık, Y. B., van der Helm, M. W., Odijk, M., Segerink, L. I., Passier, R. C., van den Berg, A., & van der Meer, A. D. (2018) · Biomicrofluidics · doi:10.1063/1.5023041 · Cited by 97
Yeste, J., Illa, X., Gutierrez, C., Solé, M., Guimerà‐Brunet, A., & Villa, R. (2016) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/49/37/375401 · Cited by 86
Human Microphysiological Models of Intestinal Tissue and Gut Microbiome
Steinway, S. N., Saleh, J., Koo, B., Delacour, D., & Kim, D. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00725 · Cited by 84
“These models have been used to evaluate drug absorption (Kimura et al., 2015; Pocock et al., 2017), nutrient absorption (Imura et al., 2009), and barrier function (Odijk et al., 2015).”
MethodModeling ischemic stroke in a triculture neurovascular unit on-a-chip
Wevers, N. R., Nair, A. L., Fowke, T. M., Pontier, M., Kasi, D. G., Spijkers, X. M., Hallard, C., Rabussier, G., van Vught, R., Vulto, P., et al. (2021) · Fluids and Barriers of the CNS · doi:10.1186/s12987-021-00294-9 · Cited by 86
Nair, A. L., Groenendijk, L., Overdevest, R., Fowke, T. M., Annida, R., Mocellin, O., de Vries, H. E., & Wevers, N. R. (2023) · Frontiers in Molecular Neuroscience · doi:10.3389/fnmol.2023.1250123 · Cited by 84
Watson, D. E., Hunziker, R., & Wikswo, J. P. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217732765 · Cited by 78
A Gut-Brain Axis-on-a-Chip for studying transport across epithelial and endothelial barriers
Kim, M., Kim, D., & Sung, J. H. (2021) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2021.06.021 · Cited by 84
Microfluidic lumen-based systems for advancing tubular organ modeling
Virumbrales-Muñoz, M., Ayuso, J. M., Gong, M. M., Humayun, M., Livingston, M. K., Lugo-Cintrón, K. M., McMinn, P., Álvarez-García, Y. R., & Beebe, D. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00705f · Cited by 76
The Progress of Intestinal Epithelial Models from Cell Lines to Gut-On-Chip
Rahman, S., Ghiboub, M., Donkers, J. M., van de Steeg, E., van Tol, E. A. F., Hakvoort, T. B. M., & de Jonge, W. J. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms222413472 · Cited by 93
Kim, H. J., Lee, J., Choi, J.-H., Bahinski, A., & Ingber, D. E. (2016) · Journal of Visualized Experiments · doi:10.3791/54344 · Cited by 69
Izadifar, Z., Charrez, B., Almeida, M., Robben, S., Pilobello, K. T., van der Graaf-Mas, J., Benz, M., Marquez, S. L., Ferrante, T. C., Shcherbina, K., et al. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116683 · Cited by 83
“…et al., 2021; Henry et al., 2017; Jalili-Fir-oozinezhad et al., 2019; Li et al., 2017; Lind et al., 2017; Maoz et al., 2017; Müller et al., 2021; Odijk et al., 2015; Riahi et al., 2016; van der Helm et al., 2019; Zhang et al., 2017) have shown their potential value for different tissue…”
Gellan Gum/Pectin Beads Are Safe and Efficient for the Targeted Colonic Delivery of Resveratrol
Prezotti, F. G., Boni, F. I., Ferreira, N. N., Silva, D., Filho, S. P. C., Almeida, A., Vasconcelos, T., Gremião, M. P. D., Cury, B. S. F., & Sarmento, B. F. C. C. (2018) · Polymers · doi:10.3390/polym10010050 · Cited by 70
“4% in the area of cell coverage inside the insert could reduce TEER by 80% [49].”
BackgroundOrgan-on-a-chip: A new tool for in vitro research
Yan, J., Li, Z., Guo, J., Liu, S., & Guo, J. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114626 · Cited by 76
Emulating Host-Microbiome Ecosystem of Human Gastrointestinal Tract in Vitro
Park, G.-S., Park, M. H., Shin, W., Zhao, C., Sheikh, S., Oh, S. J., & Kim, H. J. (2017) · Stem Cell Reviews and Reports · doi:10.1007/s12015-017-9739-z · Cited by 73
“coli [15, 16, 18, 136, 138, 139] 322 Stem Cell Rev and Rep (2017) 13:321–334”
Mir, M., Palma-Florez, S., Lagunas, A., Lopez-Martinez, M. J., & Samitier, J. (2022) · ACS Sensors · doi:10.1021/acssensors.2c00333 · Cited by 70
Microfluidic assay for the on-chip electrochemical measurement of cell monolayer permeability
Wong, J. F., & Simmons, C. A. (2019) · Lab on a Chip · doi:10.1039/c8lc01321g · Cited by 66
Skin-on-a-Chip Technology: Microengineering Physiologically Relevant In Vitro Skin Models
Zoio, P., & Oliva, A. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14030682 · Cited by 77
“4%) can result in the measured TEER values dropping by approximately 80% [100].”
BackgroundOrgan-on-a-Chip Applications in Microfluidic Platforms
An, L., Liu, Y., & Liu, Y. (2025) · Micromachines · doi:10.3390/mi16020201 · Cited by 79
“Odijk et al. again emphasized that additional factors must be considered when comparing the TEER values of different platforms by comparing measurements from organ chips and transwell models (Figure 6II) [105].”
Advances in TEER measurements of biological barriers in microphysiological systems
Nazari, H., Shrestha, J., Naei, V. Y., Bazaz, S. R., Sabbagh, M., Thiery, J. P., & Warkiani, M. E. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115355 · Cited by 73
Recent advances and future applications of microfluidic live-cell microarrays
Rothbauer, M., Wartmann, D., Charwat, V., & Ertl, P. (2015) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.06.006 · Cited by 68
Recent advances in blood-brain barrier-on-a-chip models
Vetter, J., Palagi, I., Waisman, A., & Blaeser, A. (2025) · Acta Biomaterialia · doi:10.1016/j.actbio.2025.03.041 · Cited by 64
Engineered Biomimetic Membranes for Organ-on-a-Chip
Rahimnejad, M., Rasouli, F., Jahangiri, S., Ahmadi, S., Rabiee, N., Farani, M. R., Akhavan, O., Asadnia, M., Fatahi, Y., Hong, S., et al. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c00531 · Cited by 59
Gut-on-a-chip for disease models
Xian, C., Zhang, J., Zhao, S., & Li, X. (2023) · Journal of Tissue Engineering · doi:10.1177/20417314221149882 · Cited by 57
Vascularized human brain organoid on-chip
Tan, S. Y., Feng, X., Cheng, L. K., & Wu, A. R. (2023) · Lab on a Chip · doi:10.1039/d2lc01109c · Cited by 64
Cacopardo, L., Costa, J. S., Giusti, S., Buoncompagni, L., Meucci, S., Corti, A., Mattei, G., & Ahluwalia, A. D. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111340 · Cited by 60
Integrated biosensors for monitoring microphysiological systems
Mou, L., Mandal, K., Mecwan, M. M., Hernández, A. L., Maity, S., Sharma, S., Herculano, R. D., Kawakita, S., Jucaud, V., Dokmeci, M. R., et al. (2022) · Lab on a Chip · doi:10.1039/d2lc00262k · Cited by 57
A Reconfigurable In Vitro Model for Studying the Blood–Brain Barrier
Moya, M. L., Triplett, M., Simon, M. G., Alvarado, J. A., Booth, R., Osburn, J. J., Soscia, D. A., Qian, F., Fischer, N. O., Kulp, K. S., et al. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02405-y · Cited by 52
Zoio, P., Lopes-Ventura, S., & Oliva, A. (2021) · Micromachines · doi:10.3390/mi12070816 · Cited by 48
“These findings are in accordance with previous studies [15,26].”
BackgroundResultHuman Organs‐on‐Chips: A Review of the State‐of‐the‐Art, Current Prospects, and Future Challenges
Zarrintaj, P., Saeb, M. R., Stadler, F. J., Yazdi, M. K., Nasirinezhad, M., Mohebbi, S., Seidi, F., Ganjali, M. R., & Mozafari, M. (2021) · Advanced Biology · doi:10.1002/adbi.202000526 · Cited by 56
Holzreuter, M. A., & Segerink, L. I. (2024) · Lab on a Chip · doi:10.1039/d3lc00901g · Cited by 53
Online and in situ analysis of organs-on-a-chip
Santbergen, M. J. C., van der Zande, M., Bouwmeester, H., & Nielen, M. W. F. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.04.006 · Cited by 49
García-Gutiérrez, E., & Cotter, P. D. (2021) · Critical Reviews in Microbiology · doi:10.1080/1040841x.2021.1979933 · Cited by 50
“TEER measurements are typically used in cell culture, but it was reported that values are typically higher in the OoC in comparison with the traditional 2D culture (Odijk et al. 2015).”
BackgroundReal-time physiological sensor-based liver-on-chip device for monitoring drug toxicity
Farooqi, H. M. U., Khalid, M. A. U., Kim, K. H., Lee, S. R., & Choi, K. H. (2020) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ababf4 · Cited by 48
“Various mathematical models have been suggested for mitigating and standardizing TEER measurement systems [16, 33, 34].”
Methodvan der Helm, M. W., Odijk, M., Frimat, J., van der Meer, A. D., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I. (2017) · Journal of Visualized Experiments · doi:10.3791/56334 · Cited by 43
“For example, measuring transendothelial or transepithelial electrical resistance (TEER) is a powerful method for monitoring non-invasively the development and disruption of barrier-forming tissues.(8,9,10) TEER is the electrical resistance across a cellular barrier and is therefore indicative of the barrier integrity…”
MethodExploiting or overcoming the dome trap for enhanced oral immunization and drug delivery
Qi, J., Zhuang, J., Lv, Y., Lü, Y., & Wu, W. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2018.02.021 · Cited by 44
Bossink, E. G. B. M., Zakharova, M., de Bruijn, D. S., Odijk, M., & Segerink, L. I. (2021) · Lab on a Chip · doi:10.1039/d0lc01289k · Cited by 45
Sei, Y. J., Ahn, S. I., Virtue, T., Kim, T., & Kim, Y. (2017) · Scientific Reports · doi:10.1038/s41598-017-10636-z · Cited by 42
Tissue chips to aid drug development and modeling for rare diseases
Low, L. A., & Tagle, D. A. (2016) · Expert Opinion on Orphan Drugs · doi:10.1080/21678707.2016.1244479 · Cited by 38
“The technology in this field is fast paced, and reporting mechanisms for these systems are improving rapidly; for example, detectors embedded in the PDMS structure of the chip may in the future be able to measure transepithelial electric resistance (TEER) more accurately than the currently standard, yet variable, Ag/A…”
BackgroundSpatial trans-epithelial electrical resistance (S-TEER) integrated in organs-on-chips
Renous, N., Kiri, M. D., Barnea, A. R., Rauti, R., Leichtmann‐Bardoogo, Y., & Maoz, B. M. (2021) · Lab on a Chip · doi:10.1039/d1lc00789k · Cited by 41
Circulating plasma exosomes in obstructive sleep apnoea and reverse dipping blood pressure
Khalyfa, A., Gozal, D., Chan, W., Andrade, J., & Prasad, B. (2019) · European Respiratory Journal · doi:10.1183/13993003.01072-2019 · Cited by 38
Vascularizing the brain in vitro
Aazmi, A., Zhou, H., Lv, W., Yu, M., Xu, X., Yang, H., Zhang, Y. S., & Ma, L. (2022) · iScience · doi:10.1016/j.isci.2022.104110 · Cited by 38
Advancing Intelligent Organ‐on‐a‐Chip Systems with Comprehensive In Situ Bioanalysis
Li, X., Zhu, H. J., Gu, B., Yao, C., Gu, Y., Xu, W., Zhang, J., He, J., Liu, X., & Li, D. (2024) · Advanced Materials · doi:10.1002/adma.202305268 · Cited by 50
Skin-on-a-chip technologies towards clinical translation and commercialization
Ismayilzada, N., Tarar, C., Dabbagh, S. R., Tokyay, B. K., Dilmani, S. A., Sokullu, E., Abaci, H. E., & Taşoğlu, S. (2024) · Biofabrication · doi:10.1088/1758-5090/ad5f55 · Cited by 43
“In addition, even in assessing the overall barrier integrity of the skin tissue, TEER holds certain limitations; namely, TEER measurement cannot accurately quantify tight junction formation if there is a small, uncovered area in the cellular monolayer [174].”
Biosensor integrated brain-on-a-chip platforms: Progress and prospects in clinical translation
Çeçen, B., Saygılı, E., Zare, I., Nejati, O., Khorsandi, D., Zarepour, A., Alarçın, E., Zarrabi, A., Topkaya, S. N., Yeşil-Çeliktaş, Ö., et al. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115100 · Cited by 36
Lucchetti, M., Werr, G., Johansson, S., Barbe, L., Grandmougin, L., Wilmes, P., & Tenje, M. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00640-x · Cited by 36
“Geometrical correction has previously been reported for other geometries 23 .”
BackgroundStretchable impedance sensor for mammalian cell proliferation measurements
Zhang, X., Wang, W., Li, F., & Voiculescu, I. (2017) · Lab on a Chip · doi:10.1039/c7lc00375g · Cited by 36
Bioengineering the Blood‐gas Barrier
Leiby, K. L., Raredon, M. S. B., & Niklason, L. E. (2020) · Comprehensive physiology · doi:10.1002/cphy.c190026 · Cited by 61
In situ biosensing technologies for an organ-on-a-chip
Kim, J., Kim, J., Jin, Y., & Cho, S. (2023) · Biofabrication · doi:10.1088/1758-5090/aceaae · Cited by 36
“Additionally, precise TEER measurements are contingent upon various factors such as electrode materials, properties, positioning, uniformity of current density across the cellular monolayer, and the electrical circuit model used for data interpretation [121].”
The Need for Physiological Micro-Nanofluidic Systems of the Brain
Frimat, J., & Lüttge, R. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00100 · Cited by 35
“This membrane also allows for TEER measurements for barrier characterization (Odijk et al., 2015; van der Helm et al., 2016).”
BackgroundBlood brain barrier: A tissue engineered microfluidic chip
Musafargani, S., Mishra, S., Gulyás, M., Mahalakshmi, P., Archunan, G., Padmanabhan, P., & Gulyás, B. Z. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108525 · Cited by 36
3D Cell Models in Radiobiology: Improving the Predictive Value of In Vitro Research
Antonelli, F. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms241310620 · Cited by 37
Applications of Polymers for Organ-on-Chip Technology in Urology
Gălățeanu, B., Hudiță, A., Bîru, E. I., Iovu, H., Zaharia, C., Simsensohn, E., Costache, M., Petca, R., & Jinga, V. (2022) · Polymers · doi:10.3390/polym14091668 · Cited by 32
“One of the first kidney-on-chip models for nephrotoxicity screening used primary renal tubular cells to assess cisplatin toxicity, and the results most resembled in vivo models [154].”
ResultUsing Biosensors to Study Organoids, Spheroids and Organs-on-a-Chip: A Mechanobiology Perspective
Yousafzai, M. S., & Hammer, J. A. (2023) · Biosensors · doi:10.3390/bios13100905 · Cited by 31
“TEER has been particularly important in studies of various biological barriers including the blood–brain barrier [206] and the epithelial linings in the gastrointestinal tract [207,208] and lung [197].”
BackgroundLi, J., Wen, A. M., Potla, R., Benshirim, E., Seebarran, A., Benz, M. A., Henry, O., Matthews, B. D., Prantil‐Baun, R., Gilpin, S. E., et al. (2019) · APL Bioengineering · doi:10.1063/1.5122967 · Cited by 30
Regulation of Intestinal Epithelial Barrier and Immune Function by Activated T Cells
Le, N., Mazahery, C., Nguyen, K., & Levine, A. D. (2020) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2020.07.004 · Cited by 30
“However, when the cell membrane is perturbed by an external stimulus, cell morphology may cause a consequential contribution to the TER.27 A monolayer with larger cells has a lower percentage of its cell surface shielded by the TJ complex through which ions can pass.”
BackgroundInfluential
Metadata
- Authors
- Odijk, M., van der Meer, A. D., Levner, D., Kim, H. J., van der Helm, M. W., Segerink, L. I., Frimat, J.-P., Hamilton, G. A., Ingber, D. E., & van den Berg, A.
- Affiliations
- University of Twente (NL)
- Wyss Institute for Biologically Inspired Engineering at Harvard University
- Harvard University (US)
- BIOS/Lab-on-Chip Group
- Corresponding author
- Odijk, Mathieu
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 15
- Issue
- 3
- Pages
- 745-752
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2145376030
- Cited by
- 209
- References
- 71
- Citations by year
- 2026: 9 · 2025: 16 · 2024: 22 · 2023: 23 · 2022: 25 · 2021: 30 · 2020: 25 · 2019: 15 · 2018: 15 · 2017: 15 · 2016: 9 · 2015: 5
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- green
- research.utwente.nl
- Licence
- other-oa
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- University of Twente Research Information (publishedVersion, other-oa)
- Radboud Repository (Radboud University) (submittedVersion)
- University of Twente Research Information (submittedVersion)
- Funders
- Defense Advanced Research Projects Agency (W911NF-12-2-0036)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
- Keywords
- transepithelial electrical resistance, organ-on-a-chip, gut-on-a-chip, microfluidics, transwell system, epithelial barrier function, measurement reproducibility
- MeSH terms
- Cells, Cultured, Humans, Electric Impedance, Caco-2 Cells, Endothelial Cells, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.