CoChat

Measuring direct current trans-epithelial electrical resistance in organ-on-a-chip microsystems

Open access
Odijk, Mathieu, van der Meer, Andries D., Levner, Daniel, Kim, Hyun Jung, van der Helm, Marinke W., Segerink, Loes I., Frimat, Jean-Phillipe, Hamilton, Geraldine A., Ingber, Donald E., van den Berg, Albert · 2015 · Lab on a Chip

The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.

Abstract

Trans-epithelial electrical resistance (TEER) measurements are widely used as real-time, non-destructive, and label-free measurements of epithelial and endothelial barrier function. TEER measurements are ideal for characterizing tissue barrier function in organs-on-chip studies for drug testing and investigation of human disease models; however, published reports using this technique have reported highly conflicting results even with identical cell lines and experimental setups. The differences are even more dramatic when comparing measurements in conventional Transwell systems with those obtained in microfluidic systems. Our goal in this work was therefore to enhance the fidelity of TEER measurements in microfluidic organs-on-chips, specifically using direct current (DC) measurements of TEER, as this is the most widely used method reported in the literature. Here we present a mathematical model that accounts for differences measured in TEER between microfluidic chips and Transwell systems, which arise from differences in device geometry. The model is validated by comparing TEER measurements obtained in a microfluidic gut-on-a-chip device versus in a Transwell culture system. Moreover, we show that even small gaps in cell coverage (e.g., 0.4%) are sufficient to cause a significant (~80%) drop in TEER. Importantly, these findings demonstrate that TEER measurements obtained in microfluidic systems, such as organs-on-chips, require special consideration, specifically when results are to be compared with measurements obtained from Transwell systems.

Overview

Integrity signals

Registry

Crossref · 10.1039/c4lc01219d

Cites

71 of 71 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Research works printed but not linked: 3

  1. Jiang, 2012, Int. J. Alzheimer's Dis., 2012, 109324
  2. Zhou, 2013, Biomed. Environ. Sci., 26, 128
  3. Blume, 2010, Pharmazie, 1, 19

Cited by

See all 209

Metadata

Authors
Odijk, M., van der Meer, A. D., Levner, D., Kim, H. J., van der Helm, M. W., Segerink, L. I., Frimat, J.-P., Hamilton, G. A., Ingber, D. E., & van den Berg, A.
Affiliations
  • University of Twente (NL)
  • Wyss Institute for Biologically Inspired Engineering at Harvard University
  • Harvard University (US)
  • BIOS/Lab-on-Chip Group
Corresponding author
Odijk, Mathieu
Venue
Lab on a Chip
Published
2015
Volume
15
Issue
3
Pages
745-752
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2145376030
Cited by
209
References
71
Citations by year
2026: 9 · 2025: 16 · 2024: 22 · 2023: 23 · 2022: 25 · 2021: 30 · 2020: 25 · 2019: 15 · 2018: 15 · 2017: 15 · 2016: 9 · 2015: 5
FWCI
5.02
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
  • University of Twente Research Information (publishedVersion, other-oa)
  • Radboud Repository (Radboud University) (submittedVersion)
  • University of Twente Research Information (submittedVersion)
Funders
Defense Advanced Research Projects Agency (W911NF-12-2-0036)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
Keywords
transepithelial electrical resistance, organ-on-a-chip, gut-on-a-chip, microfluidics, transwell system, epithelial barrier function, measurement reproducibility
MeSH terms
Cells, Cultured, Humans, Electric Impedance, Caco-2 Cells, Endothelial Cells, Lab-On-A-Chip Devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.