A microneedle biosensor for minimally-invasive transdermal detection of nerve agents
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A microneedle array based biosensor for minimally invasive electrochemical monitoring of organophosphate (OP) nerve agents under the skin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Self-citationDesign and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309
Composition of interstitial fluid
Fogh-Andersen, N., Altura, B. M., Altura, B. T., & Siggaard-Andersen, O. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.10.1522 · Cited by 309
Cited by
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Shrivastava, S., Trung, T. Q., & Lee, N.-E. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00319c · Cited by 497
Broza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Artificial intelligence biosensors: Challenges and prospects
Jin, X., Liu, C., Xu, T., Su, L., & Zhang, X. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112412 · Cited by 399
Goud, K. Y., Moonla, C., Mishra, R. K., Yu, C., Narayan, R., Litvan, I., & Wang, J. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01127 · Cited by 354
Self-citationLab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310
Self-citationMayer, M., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00719 · Cited by 300
Wearable Bioelectronics: Enzyme-Based Body-Worn Electronic Devices
Kim, J., Jeerapan, I., Sempionatto, J. R., Barfidokht, A., Mishra, R. K., Campbell, A. S., Hubble, L. J., & Wang, J. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00451 · Cited by 289
Self-citationSkin in the diagnostics game: Wearable biosensor nano- and microsystems for medical diagnostics
Dervisevic, M., Alba, M., Prieto-Simon, B., & Voelcker, N. H. (2020) · Nano Today · doi:10.1016/j.nantod.2019.100828 · Cited by 203
Mamun, M. A. A., & Yuce, M. R. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202005703 · Cited by 201
Wearable electrochemical glove-based sensor for rapid and on-site detection of fentanyl
Barfidokht, A., Mishra, R. K., Seenivasan, R., Liu, S., Hubble, L. J., Wang, J., & Hall, D. A. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.04.053 · Cited by 195
Self-citationWearable Electrochemical Biosensors for Advanced Healthcare Monitoring
Duan, H., Peng, S., He, S., Tang, S., Goda, K., Wang, C. H., & Li, M. (2025) · Advanced Science · doi:10.1002/advs.202411433 · Cited by 195
Vora, L. K., Sabri, A. H., McKenna, P. E., Himawan, A., Hutton, A. R. J., Detamornrat, U., Paredes, A. J., Larrañeta, E., & Donnelly, R. F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00108-7 · Cited by 193
Wu, Z., Qiao, Z., Chen, S., Fan, S., Liu, Y., Qi, J., & Lim, C. T. (2024) · Communications Materials · doi:10.1038/s43246-024-00468-6 · Cited by 183
Gowers, S. A. N., Freeman, D. M. E., Rawson, T. M., Rogers, M. L., Wilson, R. C., Holmes, A. H., Cass, A. E., & O’Hare, D. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00288 · Cited by 159
Li, G., & Wen, D. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02474c · Cited by 119
Advances in microneedle-based transdermal delivery for drugs and peptides
Aich, K., Singh, T., & Dang, S. (2022) · Drug Delivery and Translational Research · doi:10.1007/s13346-021-01056-8 · Cited by 65
“[52] designed MN-based electrochemical biosensors for the detection of organophosphate chemicals, neurotoxins often used in chemical weapons.”
BackgroundCheng, S., Gu, Z., Zhou, L., Hao, M., An, H., Song, K., Wu, X., Zhang, K., Zhao, Z., Dong, Y., et al. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.765987 · Cited by 64
Metadata
- Authors
- Mishra, R. K., Vinu Mohan, A. M., Soto, F., Chrostowski, R., & Wang, J.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2017
- Volume
- 142
- Issue
- 6
- Pages
- 918-924
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2586252654
- Cited by
- 110
- References
- 3
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.