The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Paper-based microfluidic system for tear electrolyte analysis
Open accessAbstract
This article describes a paper-based microfluidic system that quantifies the concentrations of tear electrolytes using a smartphone-based reader.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Phenylboronic acids form reversible covalent bonds with glucose molecules.70”
From Wearables in Medicine (2018) · cites this paper as [70]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 2,017
Self-citationLigand design for selective complexation of metal ions in aqueous solution
Hancock, R. D., & Martell, A. E. (1989) · Chemical Reviews · doi:10.1021/cr00098a011 · Cited by 1,180
Gokel, G. W. (1991) · Royal Society of Chemistry eBooks · doi:10.1039/9781788010917 · Cited by 754
Importance of the Lipid Layer in Human Tear Film Stability and Evaporation
Craig, J. P., & Tomlinson, A. (1997) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1997.tb04573.x · Cited by 472
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466
Self-citationImpaired functional visual acuity of dry eye patients
Goto, E., Yagi, Y., Matsumoto, Y., & Tsubota, K. (2002) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(01)01365-4 · Cited by 428
Tear Film, Contact Lens, and Patient-Related Factors Associated with Contact Lens–Related Dry Eye
Nichols, J. J., & Sinnott, L. T. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-1392 · Cited by 410
Chotikavanich, S., de Paiva, C. S., Li, D., Chen, J. J., Bian, F., Farley, W. J., & Pflugfelder, S. C. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-2476 · Cited by 405
Studien zur Physiologie und Pathologie der Tränenabsonderung und Tränenabfuhr
Schirmer, O. (1903) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/bf01946264 · Cited by 400
The Ocular Surface and Tear Film and Their Dysfunction in Dry Eye Disease
Rolando, M., & Zierhut, M. (2001) · Survey of Ophthalmology · doi:10.1016/s0039-6257(00)00203-4 · Cited by 371
Importance of the lipid layer in human tear film stability and evaporation
(1997) · International Contact Lens Clinic · doi:10.1016/s0892-8967(97)90017-1 · Cited by 371
Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid
Alexeev, V. L., Das, S., Finegold, D. N., & Asher, S. A. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039701 · Cited by 370
Tear analysis in ocular surface diseases
Zhou, L., & Beuerman, R. W. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.06.002 · Cited by 318
The Lacrimal Secretory System and its Treatment
Jones, L. T. (1966) · American Journal of Ophthalmology · doi:10.1016/0002-9394(66)91676-x · Cited by 296
A smartphone algorithm with inter-phone repeatability for the analysis of colorimetric tests
Yetisen, A. K., Martinez-Hurtado, J. L., Garcia-Melendrez, A., da Cruz Vasconcellos, F., & Lowe, C. R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.077 · Cited by 285
Self-citationPerformance of Tear Osmolarity Compared to Previous Diagnostic Tests for Dry Eye Diseases
Versura, P., Profazio, V., & Campos, E. C. (2010) · Current Eye Research · doi:10.3109/02713683.2010.484557 · Cited by 265
The thickness of the human precorneal tear film: evidence from reflection spectra.
King-Smith, P. E., Fink, B. A., Fogt, N., Nichols, K. K., Hill, R. M., & WILSON, G. S. (2000) · PubMed · Cited by 257
Responses of Contact Lens Wearers to a Dry Eye Survey
Begley, C. G., Caffery, B. E., Nichols, K. K., & Chalmers, R. L. (2000) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2000.tb01021.x · Cited by 248
The Incidence and Risk Factors for Developing Dry Eye After Myopic LASIK
de Paiva, C. S., Chen, Z., Koch, D. D., Hamill, M. B., Manuel, F. K., Hassan, S., Wilhelmus, K. R., & Pflugfelder, S. C. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.10.006 · Cited by 240
The effect of hinge position on corneal sensation and dry eye after LASIK
Donnenfeld, E. D., Solomon, K. D., Perry, H. D., Doshi, S. J., Ehrenhaus, M. P., Solomon, R., & Biser, S. A. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00100-3 · Cited by 189
Lacrimal Gland, Tear Film, and Dry Eye Syndromes 3
(2002) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-0717-8 · Cited by 189
Physical chemistry of the normal and disordered tear film.
Holly, F. J. (1985) · PubMed · Cited by 174
Dry eye after refractive surgery
Ang, R. E. T., Dartt, D. A., & Tsubota, K. (2001) · Current Opinion in Ophthalmology · doi:10.1097/00055735-200108000-00013 · Cited by 163
Benelli, U., Nardi, M., Posarelli, C., & Albert, T. G. (2010) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2010.01.003 · Cited by 145
Tiffany, J. M. (2003) · Eye · doi:10.1038/sj.eye.6700566 · Cited by 143
Pankratov, D., González‐Arribas, E., Blum, Z., & Shleev, S. (2016) · Electroanalysis · doi:10.1002/elan.201501116 · Cited by 135
Goto, E. (2002) · British Journal of Ophthalmology · doi:10.1136/bjo.86.12.1403 · Cited by 130
Human Tear Film Electrolyte Concentrations in Health and Dry-Eye Disease
Gilbard, J. P. (1994) · International Ophthalmology Clinics · doi:10.1097/00004397-199403410-00005 · Cited by 122
Yamada, K., Takaki, S., Komuro, N., Suzuki, K., & Citterio, D. (2014) · The Analyst · doi:10.1039/c3an01926h · Cited by 114
Sambursky, R. P., Davitt, W. F., Friedberg, M. L., & Tauber, S. (2014) · Cornea · doi:10.1097/ico.0000000000000175 · Cited by 103
Diagnostic Tests in Patients with Symptoms of Keratoconjunctivitis Sicca
Goren, M. B., & Goren, S. B. (1988) · American Journal of Ophthalmology · doi:10.1016/0002-9394(88)90587-9 · Cited by 97
Variability of Tear Osmolarity in Patients With Dry Eye
Bunya, V. Y., Fuerst, N. M., Pistilli, M., McCabe, B. E., Salvo, R., Macchi, I., Ying, G., & Massaro‐Giordano, M. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.0429 · Cited by 91
Dynamics of ocular surface pH.
Coles, W. H., & Jaros, P. A. (1984) · British Journal of Ophthalmology · doi:10.1136/bjo.68.8.549 · Cited by 89
Human Tear Protein Analysis Enabled by an Alkaline Microfluidic Homogeneous Immunoassay
Karns, K., & Herr, A. E. (2011) · Analytical Chemistry · doi:10.1021/ac202061v · Cited by 89
Kaufman, H. E. (2012) · Cornea · doi:10.1097/ico.0b013e3182541e9a · Cited by 88
Lacrimal Gland, Tear Film, and Dry Eye Syndromes
Sullivan, D. A. (1994) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-2417-5 · Cited by 80
Desiccating stress-induced disruption of ocular surface immune tolerance drives dry eye disease
Guzmán, M., Keitelman, I. A., Sabbione, F., Trevani, A. S., Giordano, M., & Galletti, J. G. (2015) · Clinical & Experimental Immunology · doi:10.1111/cei.12759 · Cited by 70
Lacrimal Gland, Tear Film, and Dry Eye Syndromes: Basic Science and Clinical Relevance
Mathers, W. D. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100140364035 · Cited by 43
Baudouin, C., Bourcier, T., Brignole‐Baudouin, F., Bertel, F., Moldovan, M., Goldschild, M., & Goguel, A. F. (2000) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s004170000179 · Cited by 40
A window to beyond the orbit: the value of optical coherence tomography in non‐ocular disease
Cameron, J. R., & Tatham, A. J. (2016) · Acta Ophthalmologica · doi:10.1111/aos.12978 · Cited by 14
Flagged first, then by citations
Research works printed but not linked: 6
- Craig, 1997, Optom. Vis. Sci., 74, 8, 10.1097/00006324-199701000-00014 · DOI
- Holly, 1984, Trans. Ophthalmol. Soc. U. K., 104, 374
- King-Smith, 2000, Invest. Ophthalmol. Visual Sci., 41, 3348
- Begley, 2000, Optom. Vis. Sci., 77, 40, 10.1097/00006324-200001000-00012 · DOI
- Hamano, 1991, Nippon Ganka Kiyo, 42, 719
- Gilbard, 1994, Int. Ophthalmol. Clin., 34, 27, 10.1097/00004397-199403410-00005 · DOI
Cited by
Sorted by citations
Supramolecular Luminescent Sensors
Mako, T. L., Racicot, J. M., & Levine, M. S. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00260 · Cited by 733
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569
Self-citationPoint-of-care testing based on smartphone: The current state-of-the-art (2017–2018)
Liu, J., Geng, Z., Fan, Z., Liu, J., & Chen, H. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.068 · Cited by 338
Yang, S., Lv, S., Zhang, W., & Cui, Y. (2022) · Sensors · doi:10.3390/s22041620 · Cited by 321
Paper-Based Sensors: Emerging Themes and Applications
Singh, A. T., Lantigua, D., Meka, A., Taing, S., Pandher, M., & Camci‐Unal, G. (2018) · Sensors · doi:10.3390/s18092838 · Cited by 284
Metadata
- Authors
- Yetisen, A. K., Jiang, N., Tamayol, A., Ruiz-Esparza, G. U., Zhang, Y. S., Medina-Pando, S., Gupta, A., Wolffsohn, J. S., Butt, H., Khademhosseini, A., & Yun, S.-H.
- Affiliations
- Brigham and Women's Hospital (US)
- Biomaterials Innovation Research Center
- Harvard–MIT Division of Health Sciences and Technology (US)
- Aston University (GB)
- University of Birmingham (GB)
- Harvard University (US)
- Corresponding author
- Yetisen, Ali K.
- Yun, Seok-Hyun
- ORCID
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2017
- Volume
- 17
- Issue
- 6
- Pages
- 1137-1148
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- PMC
- PMC5433427
- OpenAlex
- W2588545273
- Cited by
- 151
- References
- 40
- Citations by year
- 2026: 11 · 2025: 15 · 2024: 17 · 2023: 8 · 2022: 17 · 2021: 26 · 2020: 21 · 2019: 16 · 2018: 14 · 2017: 5
- FWCI
- 6.90
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- Locations
- Lab on a Chip (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Aston Publications Explorer (Aston University) (acceptedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion, cc-by)
- Spiral (Imperial College London) (submittedVersion, cc-by)
- Funders
- Wellcome Trust (201929/Z/16/Z)
- Royal Society
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Health Sciences › Medicine › Ophthalmology › Ocular Surface and Contact Lens
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
- Keywords
- paper-based microfluidics, dry eye, pH measurement
- MeSH terms
- Electrolytes, Equipment Design, Humans, Paper, Potassium, Sodium, Tears, Dry Eye Syndromes, Microfluidic Analytical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›