Integrated microfluidic system for cell co-culture and simulation of drug metabolism
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
We present a microfluidic integrator for cell cocultivation and simulation of pharmaceutical kinetic processes of oral drugs including intestinal absorption, liver metabolism, and anticancer activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The role of iron and reactive oxygen species in cell death
Dixon, S. J., & Stockwell, B. R. (2014) · Nature Chemical Biology · doi:10.1038/nchembio.1416 · Cited by 2,381
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
An On-Chip Small Intestine–Liver Model for Pharmacokinetic Studies
Kimura, H., Ikeda, T., Nakayama, H., Sakai, Y., & Fujii, T. (2015) · SLAS Technology · doi:10.1177/2211068214557812 · Cited by 136
Gao, D., Liu, H., Lin, J.-M., Wang, Y., & Jiang, Y. (2013) · Lab on a Chip · doi:10.1039/c2lc41215b · Cited by 135
Self-citationLin, X., Chen, Q., Liu, W., Zhang, J., Wang, S., Lin, Z., & Lin, J.-M. (2015) · Scientific Reports · doi:10.1038/srep09643 · Cited by 67
Self-citationThree Dimensional Microfluidic Cell Arrays for ex Vivo Drug Screening with Mimicked Vascular Flow
Dereli-Korkut, Z., Akaydin, H. D., Ahmed, A. H. R., Jiang, X., & Wang, S. (2014) · Analytical Chemistry · doi:10.1021/ac403899j · Cited by 62
Cited by
Recent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277
Tsamandouras, N., Chen, W. L. K., Edington, C. D., Stokes, C. L., Griffith, L. G., & Cirit, M. (2017) · The AAPS Journal · doi:10.1208/s12248-017-0122-4 · Cited by 222
Satoh, T., Sugiura, S., Shin, K., Onuki-Nagasaki, R., Ishida, S., Kikuchi, K., Kakiki, M., & Kanamori, T. (2018) · Lab on a Chip · doi:10.1039/c7lc00952f · Cited by 181
Flat and microstructured polymeric membranes in organs-on-chips
Pasman, T., Grijpma, D., Stamatialis, D., & Poot, A. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2018.0351 · Cited by 98
Metadata
- Authors
- Jie, M., Li, H.-F., Lin, L., Zhang, J., & Lin, J.-M.
- Venue
- RSC Advances
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2016
- Volume
- 6
- Issue
- 59
- Pages
- 54564-54572
- ISSN
- 2046-2069 (ISSN-L)
- OpenAlex
- W2400757806
- Cited by
- 54
- References
- 9
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integrated microfluidic system for cell co-culture and simulation of drug metabolism. https://app.cochat.ai/papers/10.1039/c6ra10407j
- The paper
- Jie, M., Li, H.-F., Lin, L., Zhang, J., & Lin, J.-M. (2016). Integrated microfluidic system for cell co-culture and simulation of drug metabolism. RSC Advances. https://doi.org/10.1039/c6ra10407j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.