Cancer immunotherapy μ-environment LabChip: taking advantage of optoelectronic tweezers
The DOI matches its Crossref record; 55 of the 56 references it cites were found in a registry or an index.
Abstract
An OET-based LabChip was developed to provide a stable and static culture μ-environment for cancer immunotherapy studies. The TiOPc-based OET facilitates the studies of cell–cell interaction resulting in apoptotic progress of cancer cells.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Apoptosis: A Review of Programmed Cell Death
Elmore, S. (2007) · Toxicologic Pathology · doi:10.1080/01926230701320337 · Cited by 13,853
Functions of natural killer cells
Vivier, E., Tomasello, E., Baratin, M., Walzer, T., & Ugolini, S. (2008) · Nature Immunology · doi:10.1038/ni1582 · Cited by 3,943
Hydrogels for biomedical applications
Hoffman, A. S. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.010 · Cited by 3,396
Innate or adaptive immunity? The example of natural killer cells
Vivier, E., Raulet, D. H., Moretta, A., Caligiuri, M. A., Zitvogel, L., Lanier, L. L., Yokoyama, W. M., & Ugolini, S. (2011) · Science · doi:10.1126/science.1198687 · Cited by 2,824
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Massively parallel manipulation of single cells and microparticles using optical images
Chiou, P. Y., Ohta, A. T., & Wu, M. C. (2005) · Nature · doi:10.1038/nature03831 · Cited by 1,444
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Monoclonal antibodies: versatile platforms for cancer immunotherapy
Weiner, L. M., Surana, R., & Wang, S. (2010) · Nature Reviews Immunology · doi:10.1038/nri2744 · Cited by 1,283
Biomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892
Microengineered hydrogels for tissue engineering
Khademhosseini, A., & Langer, R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.021 · Cited by 830
Activation of NK cell cytotoxicity
Smyth, M. J., Cretney, E., Kelly, J. M., Westwood, J. A., Street, S. E. A., Yagita, H., Takeda, K., Dommelen, S. L. H. V., Degli-Esposti, M. A., & Hayakawa, Y. (2005) · Molecular Immunology · doi:10.1016/j.molimm.2004.07.034 · Cited by 714
NK cell-based immunotherapy for malignant diseases
Cheng, M., Chen, Y., Xiao, W., Sun, R., & Tian, Z. (2013) · Cellular & Molecular Immunology · doi:10.1038/cmi.2013.10 · Cited by 631
Self-citationDi Carlo, D., Aghdam, N., & Lee, L. P. (2006) · Analytical Chemistry · doi:10.1021/ac060541s · Cited by 458
Ma, C., Fan, R., Ahmad, H., Shi, Q., Comin-Anduix, B., Chodon, T., Koya, R. C., Liu, C.-C., Kwong, G. A., Radu, C. G., et al. (2011) · Nature Medicine · doi:10.1038/nm.2375 · Cited by 441
Self-citationNK cells at the interface between innate and adaptive immunity
Moretta, A., Marcenaro, E., Parolini, S., Ferlazzo, G., & Moretta, L. (2008) · Cell Death & Differentiation · doi:10.1038/sj.cdd.4402170 · Cited by 387
Single-cell technologies for monitoring immune systems
Chattopadhyay, P. K., Gierahn, T. M., Roederer, M., & Love, J. C. (2014) · Nature Immunology · doi:10.1038/ni.2796 · Cited by 369
Natural killer cell cytotoxicity: how do they pull the trigger?
Topham, N. J., & Hewitt, E. W. (2009) · Immunology · doi:10.1111/j.1365-2567.2009.03123.x · Cited by 298
Cell‐cell signaling by direct contact increases cell proliferation via a PI3K‐dependent signal
Nelson, C. M., & Chen, C. S. (2002) · FEBS Letters · doi:10.1016/s0014-5793(02)02370-0 · Cited by 264
Single cell trapping and DNA damage analysis using microwell arrays
Wood, D. K., Weingeist, D. M., Bhatia, S. N., & Engelward, B. P. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1004056107 · Cited by 263
Overview of single-cell analyses: microdevices and applications
Lindström, S., & Andersson-Svahn, H. (2010) · Lab on a Chip · doi:10.1039/c0lc00150c · Cited by 260
Single-Cell Microarray for Analyzing Cellular Response
Yamamura, S., Kishi, H., Tokimitsu, Y., Kondo, S., Honda, R., Rao, S. R., Omori, M., Tamiya, E., & Muraguchi, A. (2005) · Analytical Chemistry · doi:10.1021/ac0515632 · Cited by 258
Chemical Analysis of Single Cells
Lin, Y., Trouillon, R., Safina, G., & Ewing, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac2009838 · Cited by 250
Li, M., Li, W. H., Zhang, J., Alici, G., & Wen, W. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/6/063001 · Cited by 223
Introduction to Chemistry and Biological Applications of Poly(ethylene glycol)
Zalipsky, S., & Harris, J. M. (1997) · ACS Symposium Series · doi:10.1021/bk-1997-0680.ch001 · Cited by 219
Rare cell capture in microfluidic devices
Pratt, E. D., Huang, C., Hawkins, B. G., Gleghorn, J. P., & Kirby, B. J. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.09.012 · Cited by 194
Moon, J. J., Hahn, M. S., Kim, I., Nsiah, B. A., & West, J. L. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0196 · Cited by 193
A microfluidic platform for 3-dimensional cell culture and cell-based assays
Kim, M. S., Yeon, J. H., & Park, J.-K. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9016-4 · Cited by 166
New flow cytometric assays for monitoring cell-mediated cytotoxicity
Zaritskaya, L., Shurin, M. R., Sayers, T. J., & Malyguine, A. M. (2010) · Expert Review of Vaccines · doi:10.1586/erv.10.49 · Cited by 159
Dynamics of single‐cell gene expression
Longo, D., & Hasty, J. (2006) · Molecular Systems Biology · doi:10.1038/msb4100110 · Cited by 158
Wang, L., Lu, J., Marchenko, S., Monuki, E. S., Flanagan, L. A., & Lee, A. P. (2009) · Electrophoresis · doi:10.1002/elps.200800637 · Cited by 142
Huang, N., Zhang, H.-L., Chung, M. T., Seo, J. H., & Kurabayashi, K. (2013) · Lab on a Chip · doi:10.1039/c3lc51211h · Cited by 136
Diffusion and interaction in PEG-DA hydrogels
Hagel, V., Haraszti, T., & Boehm, H. (2013) · Biointerphases · doi:10.1186/1559-4106-8-36 · Cited by 126
NK Cells Stimulate Proliferation of T and NK Cells through 2B4/CD48 Interactions
Assarsson, E., Kambayashi, T., Schatzle, J. D., Cramer, S. O., von Bonin, A., Jensen, P. E., Ljunggren, H., & Chambers, B. J. (2004) · The Journal of Immunology · doi:10.4049/jimmunol.173.1.174 · Cited by 116
Fu, C.-Y., Tseng, S., Yang, S., Hsu, L., Liu, C., & Chang, H. (2014) · Biofabrication · doi:10.1088/1758-5082/6/1/015009 · Cited by 97
Self-citationA Novel Method for Assessment of Natural Killer Cell Cytotoxicity Using Image Cytometry
Somanchi, S. S., McCulley, K. J., Somanchi, A., Chan, L. L., & Lee, D. A. (2015) · PLoS ONE · doi:10.1371/journal.pone.0141074 · Cited by 93
An opto-thermocapillary cell micromanipulator
Hu, W., Fan, Q., & Ohta, A. T. (2013) · Lab on a Chip · doi:10.1039/c3lc50389e · Cited by 79
Imaging Immune Surveillance of Individual Natural Killer Cells Confined in Microwell Arrays
Guldevall, K., Vanherberghen, B., Frisk, T., Hurtig, J., Christakou, A. E., Manneberg, O., Lindström, S., Andersson-Svahn, H., Wiklund, M., & Önfelt, B. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015453 · Cited by 73
Single‐cell technologies to study the immune system
Proserpio, V., & Mahata, B. (2015) · Immunology · doi:10.1111/imm.12553 · Cited by 72
High-Density Microwell Chip for Culture and Analysis of Stem Cells
Lindström, S., Eriksson, M., Vazin, T., Sandberg, J., Lundeberg, J., Frisén, J., & Svahn, H. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006997 · Cited by 67
Diamagnetically trapped arrays of living cells above micromagnets
Kauffmann, P., Ith, A., O'Brien, D., Gaude, V., Boué, F., Combe, S., Brückert, F., Schaack, B., Dempsey, N. M., Haguet, V., et al. (2011) · Lab on a Chip · doi:10.1039/c1lc20232d · Cited by 58
Microchip Screening Platform for Single Cell Assessment of NK Cell Cytotoxicity
Guldevall, K., Brandt, L., Forslund, E., Olofsson, K., Frisk, T. W., Olofsson, P. E., Gustafsson, K. U., Manneberg, O., Vanherberghen, B., Brismar, H., et al. (2016) · Frontiers in Immunology · doi:10.3389/fimmu.2016.00119 · Cited by 57
A microfluidic array for real-time live-cell imaging of human and rodent pancreatic islets
Nourmohammadzadeh, M., Xing, Y., Lee, J. W., Bochenek, M. A., Mendoza-Elias, J. E., McGarrigle, J. J., Marchese, E., Chun-Chieh, Y., Eddington, D., Oberholzer, J., et al. (2016) · Lab on a Chip · doi:10.1039/c5lc01173f · Cited by 54
Facile micropatterning of dual hydrogel systems for 3D models of neurite outgrowth
Curley, J. L., & Moore, M. J. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.33195 · Cited by 53
NK cell proliferation and inflammation
Warren, H. S. (1996) · Immunology and Cell Biology · doi:10.1038/icb.1996.78 · Cited by 41
Iliescu, C., Tresset, G., & Xu, G. (2007) · Applied Physics Letters · doi:10.1063/1.2747187 · Cited by 37
Forslund, E., Guldevall, K., Olofsson, P. E., Frisk, T., Christakou, A., Wiklund, M., & Önfelt, B. (2012) · Front. Immun. · doi:10.3389/fimmu.2012.00300 · Cited by 35
System-level simulation of liquid filling in microfluidic chips
Song, H., Wang, Y., & Pant, K. (2011) · Biomicrofluidics · doi:10.1063/1.3589843 · Cited by 32
Yang, S., Tseng, S., Chen, H.-P., Hsu, L., & Liu, C. (2013) · Lab on a Chip · doi:10.1039/c3lc50351h · Cited by 27
Self-citationAdvanced Flow Cytometry: Applications in Biological Research
(2003) · Springer eBooks · doi:10.1007/978-94-017-0623-0 · Cited by 19
Abonnenc, M., Borgatti, M., Fabbri, E., Gavioli, R., Fortini, C., Destro, F., Altomare, L., Manaresi, N., Medoro, G., Romani, A., et al. (2013) · The Journal of Immunology · doi:10.4049/jimmunol.1300890 · Cited by 18
Microfluidic dielectrophoretic sorter using gel vertical electrodes
Luo, J., Nelson, E. L., Li, G. P., & Bachman, M. (2014) · Biomicrofluidics · doi:10.1063/1.4880244 · Cited by 15
Sivashankar, S., Puttaswamy, S. V., Lin, L.-H., Dai, T.-S., Yeh, C., & Liu, C. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.09.087 · Cited by 9
Self-citationOptoelectronic Tweezers for the Manipulation of Cells, Microparticles, and Nanoparticles
Aaron, T., Chiou, P.-Y. E., Jamshidi, A., Hsu, H.-Y., Justin, K., Steven, L. S., & Chen, M. (2010) · InTech eBooks · doi:10.5772/6921 · Cited by 7
Research works printed but not linked: 5
- E. O. Mecha , Natural Killer Cells as Potential Markers for HIV/AIDS Progression , BoD–Books on Demand , 2014
- Q. A. Acton , Mononuclear Leukocytes—Advances in Research and Application: 2013 Edition , ScholarlyEditions, 2013
- Kandarian, 2017, J. Visualized Exp., e56191
- Villas, 1997, Cell Vision, 5, 56
- Trinchieri, 1989, Adv. Immunol., 47, 376
Cited by
Microfluidic modelling of the tumor microenvironment for anti-cancer drug development
Shang, M., Soon, R. H., Lim, C. T., Khoo, B. L., & Han, J. (2019) · Lab on a Chip · doi:10.1039/c8lc00970h · Cited by 227
NK cells are never alone: crosstalk and communication in tumour microenvironments
Zhou, Y., Cheng, L., Liu, L., & Li, X. (2023) · Molecular Cancer · doi:10.1186/s12943-023-01737-7 · Cited by 172
Optoelectronic tweezers: a versatile toolbox for nano-/micro-manipulation
Zhang, S., Xu, B., Elsayed, M., Nan, F., Liang, W., Valley, J. K., Liu, L., Huang, Q., Wu, M. C., & Wheeler, A. R. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00359g · Cited by 158
The optoelectronic microrobot: A versatile toolbox for micromanipulation
Zhang, S., Scott, E., Singh, J., Chen, Y., Zhang, Y., Elsayed, M., Chamberlain, M. D., Shakiba, N., Adams, K. V., Yu, S., et al. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1903406116 · Cited by 147
Self-citationZhang, J., Tavakoli, H., Ma, L., Li, X., Han, L., & Li, X. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114365 · Cited by 114
Metadata
- Authors
- Ke, L.-Y., Kuo, Z.-K., Chen, Y.-S., Yeh, T.-Y., Dong, M., Tseng, H.-W., & Liu, C.-H.
- Affiliations
- National Tsing Hua University (TW)
- Industrial Technology Research Institute (TW)
- Corresponding author
- Liu, Cheng-Hsien
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2018
- Volume
- 18
- Issue
- 1
- Pages
- 106-114
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2772513942
- Cited by
- 50
- References
- 56
- Citations by year
- 2026: 5 · 2025: 4 · 2024: 8 · 2023: 2 · 2022: 6 · 2021: 10 · 2020: 4 · 2019: 7 · 2018: 4
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Industrial Technology Research Institute
- National Tsing Hua University
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Keywords
- cancer immunotherapy, optoelectronic tweezers, NK cell cytotoxicity, cell-cell contact, microenvironment
- MeSH terms
- Animals, Antineoplastic Agents, Cell Line, Equipment Design, Humans, Immunotherapy, Killer Cells, Natural, Models, Biological, Apoptosis, K562 Cells, Mice, Optical Tweezers, Lab-On-A-Chip Devices, Tumor Microenvironment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.