Conductive elastomer composites for fully polymeric, flexible bioelectronics
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Soft, flexible and stretchable conductive elastomers made of polyurethane and PEDOT:PSS blends were fabricated into fully polymeric implantable bioelectrode arrays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691
Self-citationGuiding Neuronal Cell Migrations
Marin, O., Valiente, M., Ge, X., & Tsai, L.-H. (2010) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a001834 · Cited by 417
Sasaki, M., Karikkineth, B. C., Nagamine, K., Kaji, H., Torimitsu, K., & Nishizawa, M. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400209 · Cited by 169
Cogan, S. F., Troyk, P. R., Ehrlich, J., & Plante, T. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851503 · Cited by 162
Stiffness quantification of conductive polymers for bioelectrodes
Hassarati, R. T., Goding, J. A., Baek, S., Patton, A. J., Poole‐Warren, L. A., & Green, R. A. (2014) · Journal of Polymer Science Part B Polymer Physics · doi:10.1002/polb.23465 · Cited by 35
Self-citation
Cited by
Laser-induced wet stability and adhesion of pure conducting polymer hydrogels
Won, D., Kim, H., Kim, J., Kim, H., Kim, M. W., Ahn, J., Min, K., Lee, Y., Hong, S., Choi, J., et al. (2024) · Nature Electronics · doi:10.1038/s41928-024-01161-9 · Cited by 186
“Conductive hydrogels 4 are of particular interest as their mechanical properties are closer to biological tissues than other materials (such as conductive composite elastomers 5 and metal percolation networks 6 ).”
Rational design of biodegradable thermoplastic polyurethanes for tissue repair
Xu, C., & Hong, Y. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.11.029 · Cited by 109
Advances in visual prostheses: engineering and biological challenges
Borda, E., & Ghezzi, D. (2022) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac812c · Cited by 44
Self-citationYin, P., Liu, Y., Xiao, L., & Zhang, C. (2021) · Polymers · doi:10.3390/polym13162834 · Cited by 42
“A few soft organic polymers (PDMS (Figure 1e) [27,28], PI [29], parylene C [30], PU [31]) have been used to fabricate neural electrodes in order to mitigate the mechanical mismatch in the tissue–electrode interface.”
MethodFernández, E., Alfaro, A., & González-López, P. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00681 · Cited by 35
“In recent years, several strategies for minimizing trauma and the inflammatory responses have been investigated, for example, the reduction of the cross-sectional area of the electrodes (Seymour and Kipke, 2007) and the use of more flexible and soft materials that better match the properties of the surrounding tissue…”
Background
Metadata
- Authors
- Cuttaz, E., Goding, J., Vallejo-Giraldo, C., Aregueta-Robles, U., Lovell, N., Ghezzi, D., & Green, R. A.
- Venue
- Biomaterials Science
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2019
- Volume
- 7
- Issue
- 4
- Pages
- 1372-1385
- ISSN
- 2047-4830 (ISSN-L)
- 2047-4849
- OpenAlex
- W2909243141
- Cited by
- 85
- References
- 8
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.