Roll-to-roll fabrication of integrated PDMS–paper microfluidics for nucleic acid amplification
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
High-volume roll-to-roll manufacturing of PDMS–paper microfluidics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While R2R printing of electrochemical electrodes and microfluidic structures has been previously and independently introduced, the system presented here further demonstrates R2R fabrication of integrated sweat rate sensors and microfluidics, representing a key application-oriented technological advancement that can help decode the rate-dependent modulation of sweat analyte secretion (41, 42).”
From Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat (2019) · cites this paper as [42]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Biological implications of polydimethylsiloxane-based microfluidic cell culture
Regehr, K. J., Domenech, M., Koepsel, J. T., Carver, K. C., Ellison-Zelski, S. J., Murphy, W. L., Schuler, L. A., Alarid, E. T., & Beebe, D. J. (2009) · Lab on a Chip · doi:10.1039/b903043c · Cited by 719
Research works printed but not linked: 18
- Becker, 2008, Anal. Bioanal. Chem., 390, 89, 10.1007/s00216-007-1692-2 · DOI · Paper page
- Gervais, 2011, Adv. Mater., 23, H151, 10.1002/adma.201100464 · DOI · Paper page
- Temiz, 2015, Microelectron. Eng., 132, 156, 10.1016/j.mee.2014.10.013 · DOI · Paper page
- Squires, 2005, Rev. Mod. Phys., 77, 977, 10.1103/RevModPhys.77.977 · DOI · Paper page
- Mark, 2010, Chem. Soc. Rev., 39, 1153, 10.1039/b820557b · DOI · Paper page
- Chin, 2012, Lab Chip, 12, 2118, 10.1039/c2lc21204h · DOI · Paper page
- He, 2013, Anal. Chem., 85, 11691, 10.1021/ac403693g · doi:10.1021/ac403693g
- Kooy, 2014, Nanoscale Res. Lett., 9, 320, 10.1186/1556-276X-9-320 · DOI · Paper page
- Peng, 2014, J. Micromech. Microeng., 24, 013001, 10.1088/0960-1317/24/1/013001 · DOI · Paper page
- Hou, 2017, Nat. Rev. Mater., 2, 17016, 10.1038/natrevmats.2017.16 · DOI · Paper page
- Xia, 1998, Annu. Rev. Mater. Sci., 28, 153, 10.1146/annurev.matsci.28.1.153 · DOI · Paper page
- Ahn, 2008, Adv. Mater., 20, 2044, 10.1002/adma.200702650 · DOI · Paper page
- Zhang, 2009, Anal. Chim. Acta, 13, 115, 10.1016/j.aca.2009.02.038 · DOI · Paper page
- Xu, 2015, Lab Chip, 15, 3962, 10.1039/C5LC00716J · DOI · Paper page
- Li, 2012, Biomicrofluidics, 6, 11301, 10.1063/1.3687398 · DOI · Paper page
- Yetisen, 2013, Lab Chip, 13, 2210, 10.1039/c3lc50169h · DOI · Paper page
- Parolo, 2013, Chem. Soc. Rev., 42, 450, 10.1039/C2CS35255A · DOI · Paper page
- Chander, 2014, Front. Microbiol., 5, 395, 10.3389/fmicb.2014.00395 · DOI
Cited by
Nyein, H. Y. Y., Bariya, M., Kivimäki, L., Uusitalo, S., Liaw, T. S., Jansson, E., Ahn, C. H., Hangasky, J. A., Zhao, J., Lin, Y., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw9906 · Cited by 388
Self-citationZhu, H., Zhang, H., Xu, Y., Laššáková, S., Korabečná, M., & Neužil, P. (2020) · BioTechniques · doi:10.2144/btn-2020-0057 · Cited by 380
Microfluidics: Innovations in Materials and Their Fabrication and Functionalization
Nielsen, J. B., Hanson, R. L., Almughamsi, H. M., Pang, C., Fish, T. R., & Woolley, A. T. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04986 · Cited by 359
Green Flexible Electronics: Natural Materials, Fabrication, and Applications
Hui, Z., Zhang, L., Ren, G., Sun, G., Yu, H., & Huang, W. (2023) · Advanced Materials · doi:10.1002/adma.202211202 · Cited by 287
LAMP-on-a-chip: Revising microfluidic platforms for loop-mediated DNA amplification
Zhang, H., Xu, Y., Fohlerova, Z., Chang, H., Iliescu, C., & Neuzil, P. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.01.015 · Cited by 232
“Roll-to-roll thermal imprinting (molding) technology was proposed for the fabrication of integrated PDMSepaper microfluidic device for molecular diagnostics [53].”
MethodFemtosecond laser programmed artificial musculoskeletal systems
Ma, Z.-C., Zhang, Y.-L., Han, B., Hu, X.-Y., Li, C.-H., Chen, Q.-D., & Sun, H.-B. (2020) · Nature Communications · doi:10.1038/s41467-020-18117-0 · Cited by 201
Engineering a sustainable future for point-of-care diagnostics and single-use microfluidic devices
Ongaro, A. E., Ndlovu, Z., Sollier, E., Otieno, C., Ondoa, P., Street, A., & Kersaudy-Kerhoas, M. (2022) · Lab on a Chip · doi:10.1039/d2lc00380e · Cited by 164
Metadata
- Authors
- Hiltunen, J., Liedert, C., Hiltunen, M., Huttunen, O.-H., Hiitola-Keinänen, J., Aikio, S., Harjanne, M., Kurkinen, M., Hakalahti, L., & Lee, L. P.
- Affiliations
- VTT-Technical Research Centre of Finland
- Department of Bioengineering
- ORCID
- Hiltunen, Jussi
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2018
- Volume
- 18
- Issue
- 11
- Pages
- 1552-1559
- ISSN
- 1473-0197
- 1473-0189
- Cited by
- 103
- References
- 4
- Language
- en
- Funders
- Academy of Finland (284907)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.