Near-infrared fluorescent molecular probes for imaging and diagnosis of nephro-urological diseases
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Near-infrared fluorescent molecular probes with improved imaging depth and optimized biodistribution have been reviewed, showing great potential for diagnosis of nephro-urological diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hong, Y., Lam, J. W. Y., & Tang, B. Z. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15113d · Cited by 6,363
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
Li, B., Lu, L., Zhao, M., Lei, Z., & Zhang, F. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201801226 · Cited by 658
Huang, J., Xie, C., Zhang, X., Jiang, Y., Li, J., Fan, Q., & Pu, K. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201909560 · Cited by 258
Self-citationHighly Stable and Bright NIR-II AIE Dots for Intraoperative Identification of Ureter
Du, J., Liu, S., Zhang, P., Liu, H., Li, Y., He, W., Li, C., Chau, J. H. C., Kwok, R. T. K., Lam, J. W. Y., et al. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b22957 · Cited by 70
A chemically stable fluorescent marker of the ureter
Cha, J., Nani, R. R., Luciano, M. P., Kline, G., Broch, A., Kim, K., Namgoong, J.-M., Kulkarni, R. A., Meier, J. L., Kim, P., et al. (2018) · Bioorganic & Medicinal Chemistry Letters · doi:10.1016/j.bmcl.2018.02.040 · Cited by 59
Cited by
Hemicyanine‐Based Near‐Infrared Activatable Probes for Imaging and Diagnosis of Diseases
Zeng, Z., Liew, S. S., Wei, X., & Pu, K. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202107877 · Cited by 359
Self-citationNear-infrared (NIR) fluorescence-emitting small organic molecules for cancer imaging and therapy
Li, H., Kim, Y., Jung, H., Hyun, J. Y., & Shin, I. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00722c · Cited by 356
Dual-locked spectroscopic probes for sensing and therapy
Wu, L., Huang, J., Pu, K., & James, T. D. (2021) · Nature Reviews Chemistry · doi:10.1038/s41570-021-00277-2 · Cited by 328
Self-citationTruong, T. T., Mondal, S., Doan, V. H. M., Tak, S., Choi, J., Oh, H., Nguyen, T. D., Misra, M., Lee, B., & Oh, J. (2024) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2024.103263 · Cited by 185
Tan, J., Yin, K., Ouyang, Z., Wang, R., Pan, H., Wang, Z., Zhao, C., Guo, W., & Gu, X. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c03926 · Cited by 52
Metadata
- Authors
- Huang, J., & Pu, K.
- Venue
- Chemical Science
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2021
- Volume
- 12
- Issue
- 10
- Pages
- 3379-3392
- ISSN
- 2041-6520 (ISSN-L)
- 2041-6539
- OpenAlex
- W3035999720
- Cited by
- 145
- References
- 6
- FWCI
- 7.24
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.