Simulating drug concentrations in PDMS microfluidic organ chips
Open accessPublished version of a preprint
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
microfluidic model to simulate the spatial and temporal gradient of a drug in 3D without prior knowledge of the partition coefficient or the rate of diffusion in PDMS. Thus, this approach may expand the use of PDMS Organ Chip devices for various forms of drug testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“often relying on polydimethylsiloxane or other highly drug-adsorbent materials.23 These materials can lead to artifactual observations in drug effects and kinetics, potentially compromising the reliability of experimental results.”
From A High-Throughput Microphysiological Liver Chip System to Model Drug-Induced Liver Injury Using Human Liver Organoids (2024) · cites this paper as [23]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationDrugBank: a comprehensive resource for in silico drug discovery and exploration
Wishart, D. S. (2006) · Nucleic Acids Research · doi:10.1093/nar/gkj067 · Cited by 3,892
QSAR Modeling: Where have you been? Where are you going to?
Cherkasov, A., Muratov, E. N., Fourches, D., Varnek, A., Baskin, I. I., Cronin, M., Dearden, J., Gramatica, P., Martin, Y. C., Todeschini, R., et al. (2014) · Journal of Medicinal Chemistry · doi:10.1021/jm4004285 · Cited by 2,164
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Self-citationQuantum-Chemical Descriptors in QSAR/QSPR Studies
Karelson, M., Lobanov, V. S., & Katritzky, A. R. (1996) · Chemical Reviews · doi:10.1021/cr950202r · Cited by 1,622
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Self-citationSmall airway-on-a-chip enables analysis of human lung inflammation and drug responses in vitro
Benam, K. H., Villenave, R., Lucchesi, C., Varone, A., Hubeau, C., Lee, H.-H., Alves, S. E., Salmon, M., Ferrante, T. C., Weaver, J. C., et al. (2016) · Nature Methods · doi:10.1038/nmeth.3697 · Cited by 816
Self-citationSmall molecule absorption by PDMS in the context of drug response bioassays
van Meer, B. J., de Vries, H., Firth, K. S. A., van Weerd, J., Tertoolen, L. G. J., Karperien, H. B. J., Jonkheijm, P., Denning, C., IJzerman, A. P., & Mummery, C. L. (2017) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2016.11.062 · Cited by 502
Herland, A., Maoz, B. M., Das, D., Somayaji, M. R., Prantil-Baun, R., Novak, R., Cronce, M., Huffstater, T., Jeanty, S. S. F., Ingram, M., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0498-9 · Cited by 500
Self-citation
Cited by
Microfluidic Tissue Engineering and Bio‐Actuation
Filippi, M., Buchner, T., Yaşa, Ö., Weirich, S., & Katzschmann, R. K. (2022) · Advanced Materials · doi:10.1002/adma.202108427 · Cited by 133
Intestinal organ chips for disease modelling and personalized medicine
Özkan, A., LoGrande, N., Feitor, J. F., Goyal, G., & Ingber, D. E. (2024) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-024-00968-3 · Cited by 109
Self-citationVat photopolymerization 3D printed microfluidic devices for organ-on-a-chip applications
Milton, L. A., Viglione, M., Ong, L. J. Y., Nordin, G. P., & Toh, Y. (2023) · Lab on a Chip · doi:10.1039/d3lc00094j · Cited by 89
3D-bioprinted cancer-on-a-chip: level-up organotypic in vitro models
Monteiro, M. V., Zhang, Y. S., Gaspar, V. M., & Mano, J. F. (2021) · Trends in biotechnology · doi:10.1016/j.tibtech.2021.08.007 · Cited by 82
Implementing organ-on-chip in a next-generation risk assessment of chemicals: a review
Nitsche, K. S., Müller, I. I., Malcomber, S., Carmichael, P. L., & Bouwmeester, H. (2022) · Archives of Toxicology · doi:10.1007/s00204-022-03234-0 · Cited by 80
Human Brain Organoids-on-Chip: Advances, Challenges, and Perspectives for Preclinical Applications
Castiglione, H., Vigneron, P.-A., Baquerre, C., Yates, F., Rontard, J., & Honegger, T. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14112301 · Cited by 78
Shinde, A. S., Illath, K., Kasiviswanathan, U., Nagabooshanam, S., Gupta, P., Dey, K., Chakrabarty, P., Nagai, M., Rao, S. R., Kar, S., et al. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.2c05036 · Cited by 76
In vitro models to study human gut-microbiota interactions: Applications, advances, and limitations
Qi, Y., Yu, L., Tian, F., Zhao, J., & Zhai, Q. (2023) · Microbiological Research · doi:10.1016/j.micres.2023.127336 · Cited by 72
An Organ‐on‐Chip Platform for Simulating Drug Metabolism Along the Gut–Liver Axis
Lucchetti, M., Aina, K. O., Grandmougin, L., Jäger, C., Escriva, P. P., Letellier, E., Mosig, A. S., & Wilmes, P. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202303943 · Cited by 79
AI-Powered Microfluidics: Shaping the Future of Phenotypic Drug Discovery
Liu, J., Du, H., Huang, L., Xie, W., Liu, K., Zhang, X., Chen, S., Zhang, Y., Li, D., & Pan, H. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c07665 · Cited by 75
Blood–brain barrier (BBB)-on-a-chip: a promising breakthrough in brain disease research
Peng, B., Hao, S., Tong, Z., Bai, H., Pan, S., Lim, K., Li, L., Voelcker, N. H., & Huang, W. (2022) · Lab on a Chip · doi:10.1039/d2lc00305h · Cited by 71
Breaking the clean room barrier: exploring low-cost alternatives for microfluidic devices
Rodríguez, C. F., Andrade-Pérez, V., Vargas, M. C., Mantilla-Orozco, A., Osma, J. F., Reyes, L. H., & Cruz, J. C. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1176557 · Cited by 67
“Additionally, PDMS has adsorptive properties for certain molecules that can affect the accuracy of experiments or their analyses (Akther et al., 2020; Grant et al., 2021).”
BackgroundLiver-on-a-chip devices: the pros and cons of complexity
Dalsbecker, P., Adiels, C. B., & Goksör, M. (2022) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00346.2021 · Cited by 64
Gut-on-a-Chip Models: Current and Future Perspectives for Host–Microbial Interactions Research
Morelli, M., Kurek, D., Ng, C. P., & Queiroz, K. C. S. (2023) · Biomedicines · doi:10.3390/biomedicines11020619 · Cited by 67
“Mathematical models have been developed to simulate drug concentrations in PDMS microfluidic chips [17].”
Engineering Organ-on-a-Chip to Accelerate Translational Research
Ko, J., Park, D., Lee, S., Gümüşcü, B., & Jeon, N. L. (2022) · Micromachines · doi:10.3390/mi13081200 · Cited by 59
“For instance, plastic materials must be preferred when studying drug toxicity screening on simple tissue culture models [12,105,107,108].”
BackgroundMechanopathology of biofilm-like Mycobacterium tuberculosis cords
Mishra, R., Hannebelle, M. T. M., Patil, V. P., Dubois, A., García-Mouton, C., Kirsch, G. M., Jan, M., Sharma, K., Guex, N., Sordet‐Dessimoz, J., et al. (2023) · Cell · doi:10.1016/j.cell.2023.09.016 · Cited by 61
Zhou, Q., Liu, Q., Wang, Y., Chen, J., Schmid, O., Rehberg, M., & Yang, L. (2024) · Advanced Science · doi:10.1002/advs.202308659 · Cited by 59
PBPK Modeling on Organs-on-Chips: An Overview of Recent Advancements
Yang, Y., Chen, Y., Wang, L., Xu, S., Fang, G., Guo, X., Chen, Z., & Gu, Z. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.900481 · Cited by 61
“the side view of the construction of organ chip (Grant et al., 2021).”
BackgroundMethodInfluentialFanizza, F., Campanile, M., Forloni, G., Giordano, C., & Albani, D. (2022) · Journal of Tissue Engineering · doi:10.1177/20417314221095339 · Cited by 58
Li, B., Tang, Y., Huang, Z., Ma, L., Song, J., & Xue, L. (2025) · Protein & Cell · doi:10.1093/procel/pwaf058 · Cited by 57
“Advanced systems incorporate pneumatically or mechanically actuated valves for dynamic perfusion control (Grant et al., 2021) or embed microelectrodes, cantilevers, or optical sensors for real-time monitoring of physiological parameters, such as pressure, dissolved oxygen levels, and electrical…”
Artificial Intelligence-Based Microfluidic Platform for Detecting Contaminants in Water: A Review
Zhang, Y., Li, J., Yu, Z., Zhang, X., & Liu, X. (2024) · Sensors · doi:10.3390/s24134350 · Cited by 52
Compound Absorption in Polymer Devices Impairs the Translatability of Preclinical Safety Assessments
Kemas, A. M., Shafagh, R. Z., Taebnia, N., Michel, M., Preiss, L. C., Hofmann, U., & Lauschke, V. M. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202303561 · Cited by 45
Droplet-based microfluidics for drug delivery applications
Fan, R., Wu, J. J., Duan, S., Jin, L., Zhang, H., Zhang, C., & Zheng, A. (2024) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2024.124551 · Cited by 43
Advances of microfluidic lung chips for assessing atmospheric pollutants exposure
Wang, H., Yin, F., Li, Z., Su, W., & Li, D. (2023) · Environment International · doi:10.1016/j.envint.2023.107801 · Cited by 43
What Can an Organ-on-a-Chip Teach Us About Human Lung Pathophysiology?
Bai, H., & Ingber, D. E. (2022) · Physiology · doi:10.1152/physiol.00012.2022 · Cited by 42
Self-citationAdvances in the Model Structure of In Vitro Vascularized Organ-on-a-Chip
Yin, H., Wang, Y., Liu, N., Zhong, S., Li, L., Zhang, Q., Liu, Z., & Yue, T. (2024) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0107 · Cited by 43
“Elastic porous membranes are commonly employed in organ chips, including polyethylene terephthalate (PET) [103], PDMS [104], electrospun membranes [105], and polycarbonate (PC) [106].”
Sorption of Neuropsychopharmaca in Microfluidic Materials for In Vitro Studies
Winkler, T. E., & Herland, A. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c07639 · Cited by 38
Small tissue chips with big opportunities for space medicine
Mu, X., He, W., Rivera, V. A. M., Alba, R. A. D. D., Newman, D. J., & Zhang, Y. S. (2022) · Life Sciences in Space Research · doi:10.1016/j.lssr.2022.09.002 · Cited by 40
Meyer, S. R., Zhang, C. J., Garcia, M. A., Procario, M. C., Yoo, S., Jolly, A. L., Kim, S., Kim, J., Baek, K., Kersten, R. D., et al. (2024) · Gastro Hep Advances · doi:10.1016/j.gastha.2024.08.004 · Cited by 35
Lubricant‐Coated Organ‐on‐a‐Chip for Enhanced Precision in Preclinical Drug Testing
Kim, T. Y., Choi, J., Park, K., Kim, S., Kim, J. F., Park, T., & Seo, J. (2024) · Small · doi:10.1002/smll.202402431 · Cited by 35
Rodrigues, P. M., Xavier, M., Calero, V., Pastrana, L. M., & Gonçalves, C. (2022) · Micromachines · doi:10.3390/mi13050713 · Cited by 33
3D Hepatic Organoid-Based Advancements in LIVER Tissue Engineering
Panwar, A., Das, P., & Tan, L. P. (2021) · Bioengineering · doi:10.3390/bioengineering8110185 · Cited by 36
“Although PDMS is the most reported material for fabrication of microfluidic chips due to its excellent gas permeability and optical clarity, it can absorb small hydrophobic molecules from the culture stream and these molecules eventually accumulate in bulk amounts inside the pores [55].”
BackgroundUgodnikov, A., Persson, H., & Simmons, C. A. (2024) · Lab on a Chip · doi:10.1039/d3lc01027a · Cited by 32
Applications of Polymers for Organ-on-Chip Technology in Urology
Gălățeanu, B., Hudiță, A., Bîru, E. I., Iovu, H., Zaharia, C., Simsensohn, E., Costache, M., Petca, R., & Jinga, V. (2022) · Polymers · doi:10.3390/polym14091668 · Cited by 32
Nishikawa, M., Ito, H., Tokito, F., Hirono, K., Inamura, K., Scheidecker, B., Danoy, M., Kawanishi, T., Arakawa, H., Kato, Y., et al. (2022) · Frontiers in Toxicology · doi:10.3389/ftox.2022.810478 · Cited by 30
“successfully simulated drug concentrations in PDMS microfluidic devices using experimentally determined diffusion and partition coefficients of drugs in PDMS (Grant et al., 2021).”
MethodKim, J. J., Bae, M., & Cho, D. (2024) · Small Science · doi:10.1002/smsc.202400314 · Cited by 29
Hydrogel membranes in organ-on-a-chip devices: A review
Gnatowski, P., Ansariaghmiuni, M., Piłat, E., Poostchi, M., Kucińska‐Lipka, J., Yazdi, M. K., Ryl, J., Ashrafizadeh, M., Mottaghitalab, F., Farokhi, M., et al. (2025) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2025.114591 · Cited by 25
Microinstrumentation for Brain Organoids
Patel, D., Shetty, S., Acha, C., Pantoja, I. E. M., Zhao, A., George, D., & Gracias, D. H. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202302456 · Cited by 25
New Frontiers in Three-Dimensional Culture Platforms to Improve Diabetes Research
Mohandas, S., Gayatri, V., Kumaran, K., Gopinath, V., Paulmurugan, R., & Ramkumar, K. M. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15030725 · Cited by 25
“Due to its biocompatibility, optical transparency for better imaging applications, and easy assembly, PDMS, a silicon-based organic polymer, is the most widely used for pancreas-on-chip devices [91,92].”
BackgroundIslet-on-a-chip for the study of pancreatic β-cell function
Rodríguez‐Comas, J., & Ramón‐Azcón, J. (2021) · In vitro models · doi:10.1007/s44164-021-00005-6 · Cited by 22
“The most commonly used material is polydimethylsiloxane (PDMS), a silicon-based organic polymer with high biocompatibility characteristics, optical transparency to facilitate imaging applications, and ease of assembly [41, 42].”
BackgroundBiomimetic epithelium/endothelium on chips
Lin, L., Wang, X., Niu, M., Wu, Q., Wang, H., Zu, Y., & Wang, W. (2022) · Engineered Regeneration · doi:10.1016/j.engreg.2022.05.001 · Cited by 24
Mazio, C., Scognamiglio, L. S., Passariello, R., Panzetta, V., Casale, C., Urciuolo, F., Galietta, L. J. V., Imparato, G., & Netti, P. A. (2023) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c01460 · Cited by 18
Organ-on-a-chip models for elucidating the cellular biology of infectious diseases
Yokoi, F., Deguchi, S., & Takayama, K. (2023) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/j.bbamcr.2023.119504 · Cited by 21
Roy, N., & Cucullo, L. (2026) · Biosensors · doi:10.3390/bios16030155 · Cited by 22
“Microfabrication materials also matter; polydimethylsiloxane (PDMS) devices absorb hydrophobic drugs, causing the actual on-chip concentration to deviate from nominal dosing [111], and drug sorption depends on hydrophobicity, flow, and medium composition.”
Microfluidic organ chip of fluid–solid dynamic curved interface
Su, H., Ma, T., Liu, X., Li, W., Shu, F., Liang, Z., Zhang, D., Zhang, X., Li, K., Wang, M., et al. (2024) · Applied Physics Reviews · doi:10.1063/5.0177386 · Cited by 18
Advancement of organ-on-chip towards next generation medical technology
Singh, G., Mishra, A., Mathur, A. K., Shastri, S., Nizam, A., Rizwan, A., Dadial, A. S., Firdous, A., & Hassan, H. (2024) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2024.100480 · Cited by 22
Samantasinghar, A., Sunildutt, N., Ahmed, F., Memon, F. H., Kang, C.-U., & Choi, K. H. (2025) · ACS Omega · doi:10.1021/acsomega.4c11227 · Cited by 19
Building Blood Vessel Chips with Enhanced Physiological Relevance
Mu, X., Gerhard‐Herman, M. D., & Zhang, Y. S. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201778 · Cited by 16
Carius, P., Weinelt, F. A., Cantow, C., Holstein, M., Teitelbaum, A. M., & Cui, Y. (2024) · Pharmaceutics · doi:10.3390/pharmaceutics16030296 · Cited by 18
“Although combinations of some physicochemical molecular properties (molecular weight < 1 kDa [12]; mean ClogP > 2.7 [8]; TPSA < 50 A 2 [24]) of small molecules have been discussed to increase the chances of ad-or absorption to PDMS, compound loss within in vitro assays seems to be influenced by…”
BackgroundInfluentialFan, Y., Li, S., Wei, D., Hou, J., Fang, Z., Han, Z., & Liu, Y. (2022) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2022.106988 · Cited by 16
Ramírez-González, G. A., Consumi-Tubito, C., Vargas-Méndez, E., & Centeno-Cerdas, C. (2025) · Polymers · doi:10.3390/polym17091263 · Cited by 14
Recent advances in micro-physiological systems for investigating tumor metastasis and organotropism
Yoon, H., del Río, J. S., Cho, S. W., & Park, T. (2024) · Lab on a Chip · doi:10.1039/d3lc01033c · Cited by 13
Bioengineered human gut-on-a-chip for advancing non-clinical pharmaco-toxicology
Shin, Y. C., Than, N., Park, S. J., & Kim, H. J. (2024) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1080/17425255.2024.2365254 · Cited by 14
“…to ensure the accurate prediction of drug ADME and the first-pass metabolism, it is imperative to incorporate precise physiological parameters that replicate human PK, such as the ratios of organ sizes, actual transport rates, clearance rates, and absorption and metabolism activities [93,141].”
Choi, H. S., Ahn, G., Na, G.-S., Chi, H. J., & Kim, D. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c00435 · Cited by 11
Negoro, R., Deguchi, S., Yamazaki, D., Takayama, K., & Fujita, T. (2025) · Scientific Reports · doi:10.1038/s41598-025-22425-0 · Cited by 11
“Although PDMS devices were used in this study, it is known that PDMS tends to sorb highly lipid-soluble drugs 23,25,26 .”
Cherukuri, R., Kim, S., Moyer, H. L., Jesse, H., Lam, P. Y., Richardson, L., Kammala, A. K., Menon, R., Rusyn, I., & Han, A. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c20917 · Cited by 10
Toxicokinetics for organ-on-chip devices
Hermann, N. G., Ficek, R. A., Markov, D. A., McCawley, L. J., & Hutson, M. S. (2025) · Lab on a Chip · doi:10.1039/d4lc00840e · Cited by 12
Larson, J. D., Jadalannagari, S., Chaff, J. T., Velez, J., Sliz, J. D., Ewart, L. C., Webster, D., & Hu, J. (2025) · Scientific Reports · doi:10.1038/s41598-025-12846-2 · Cited by 9
Microbiota‐gut‐brain axis multi‐organ chip construction and applications in drug evaluation
Tang, Y., Chen, H., Zhao, Z., Kang, X., Wang, W., Dai, K., Guo, Y., Liang, A., Luo, A., & Hao, Z. (2025) · iMetaOmics. · doi:10.1002/imo2.70065 · Cited by 11
“Additionally, the adsorption effect of PDMS material on hydrophobic small drug molecules interferes with detection precision [69, 70].”
A system for fluid pumping by liquid metal multi-droplets
Dai, L., Wu, X., Hou, H., Hu, Z., Lin, Y., & Yuan, Z. (2024) · Lab on a Chip · doi:10.1039/d3lc01017a · Cited by 9
Dewhurst, R. M., Molinari, E., & Sayer, J. A. (2023) · Microfluidics and Nanofluidics · doi:10.1007/s10404-023-02629-4 · Cited by 9
Advances in organ‐on‐a‐chip for the treatment of cardiovascular diseases
Liu, J., & Wang, Y. (2023) · MedComm – Biomaterials and Applications · doi:10.1002/mba2.63 · Cited by 14
Zhang, X., Xu, F., Shi, Y., Zhang, H., Dong, X., & Bai, Y. (2025) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2025.118554 · Cited by 8
Wang, Y., Liu, A., Zhang, X., Lyu, Y., Rong, X., Niu, C., Jia, C., Sun, J., Ye, F., Shao, C., et al. (2025) · Journal of Tissue Engineering · doi:10.1177/20417314251394447 · Cited by 9
“41,42 Through soft lithography technology, PDMS can be created into various complex microstructures, including narrow, pleated, and multi-chambers, to mimic arterial structures in various clinical situations.”
Gökçe, F., Kaestli, A. J., Lohasz, C., de Geus, M., Kaltenbach, H., Renggli, K., Bornhauser, B. C., Hierlemann, A. R., & Modena, M. M. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202202506 · Cited by 8
Amend, N., Koller, M., Schmitt, C., Worek, F., & Wille, T. (2023) · Toxicology Letters · doi:10.1016/j.toxlet.2023.10.007 · Cited by 8
In vitro high-content tissue models to address precision medicine challenges
Afewerki, S., Stocco, T. D., Silva, A. D. R., Furtado, A. S. A., de Sousa, G. F., Ruiz‐Esparza, G. U., Webster, T. J., Marciano, F. R., Strømme, M., Zhang, Y. S., et al. (2022) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2022.101108 · Cited by 9
Gensheimer, T., Fuchs, S., de Heus, L. E., Vermeul, K., Mayr, T., & van der Meer, A. D. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202500194 · Cited by 7
Paper-Based Microfluidic Devices: A Powerful Strategy for Rapid Detection
Liu, X., Xu, W., Jiang, H., Liu, R., Kong, Z., Zhu, J., Sun, Z., Jiao, S., Li, W., & Wang, Y. (2025) · Micromachines · doi:10.3390/mi17010064 · Cited by 9
“PDMS has become the most popular polymer in the research of µ PADs due to its ease of manufacture, transparency, low electrical conductivity, and elasticity [68].”
Intestinal Cells-on-Chip for Permeability Studies
Keuper-Navis, M., Amirabadi, H. E., Donkers, J. M., Walles, M., Poller, B., Heming, B., Pieters, L., de Wagenaar, B., Myszczyszyn, A., Sinnige, T. L., et al. (2024) · Micromachines · doi:10.3390/mi15121464 · Cited by 8
“To some extent, the recovery can be accounted for in the modelling of the data [41]; however, it can create issues with read-out sensitivity.”
Salivary gland tissue chip screening identifies candidate radioprotective drugs
Piraino, L. R., Chen, C., Mereness, J. A., Dunman, P. M., Ovitt, C. E., Benoit, D. S. W., & DeLouise, L. A. (2025) · Communications Medicine · doi:10.1038/s43856-025-01136-7 · Cited by 7
“The25 doublehitsspanawiderangeoflog P valuesfrom5to − 3.8(Supplementary Table5),withmostdrugsexhibitinghydrophobicproperties(positivelogP), lesseningconcernsthathydrophobicdrugabsorptiontoPDMShinders ‘ hit ’ identi fi cation 72,73 .”
InfluentialZhang, W., Shuai, J., Qiu, H., Zhang, X., Li, K., Zhou, J., Li, H., & Fu, L. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.165891 · Cited by 6
Sepsis modelling: current approaches and organ-on-chip perspectives
Silva, M. J., Fehrenbach, G. W., Pogue, R. E., Murray, P., Rezoagli, E., Laffey, J. G., & Murphy, E. J. (2026) · EBioMedicine · doi:10.1016/j.ebiom.2026.106120 · Cited by 6
Human Multi-Organ-on-a-Chip Platforms for Next-Generation Drug Delivery Strategies
Mitchell, C. S., Hong-Il, Y., Díaz, C. G., Green, J. J., & Kim, D.-H. (2026) · Theranostics · doi:10.7150/thno.130030 · Cited by 7
“Finite element modeling approaches have since been employed to simulate drug concentration dynamics within PDMS devices, enabling more accurate dose-response corrections without requiring full material substitution [175,176].”
Negi, V., Gavlock, D. C., Miedel, M. T., Lee, J. K., Shun, T., Gough, A., Vernetti, L. A., Stern, A. M., Taylor, D. L., & Yechoor, V. K. (2023) · Lab on a Chip · doi:10.1039/d3lc00285c · Cited by 6
Nam, K. S., & Hwang, J. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202501372 · Cited by 5
Organ-on-chip systems in micro- and nanoplastic toxicology: A selective revolution for human health
Kutralam-Muniasamy, G., Shruti, V. C., Pérez‐Guevara, F., & Álvarez, R. C. (2026) · Current Opinion in Toxicology · doi:10.1016/j.cotox.2026.100577 · Cited by 5
Shetty, S., Kumar, N. A. N., Kabekkodu, S. P., & Chakrabarty, S. (2026) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2026.189627 · Cited by 6
Lee, E., Chary, A., Gerelkhuu, Z., Weber, P., Virmani, I., Brugger, B. A., Ribeiro, I. R. S., Brun, E., Lacconi, V., Bang, H., et al. (2026) · Nano Convergence · doi:10.1186/s40580-026-00566-w · Cited by 5
In situ formation and culture of cell spheroids in a low-binding 3D-printed biochip
Martins, A., Klieber, S., Graët, C. L., Leclerc, É., Legallais, C., & Jellali, R. (2025) · Lab on a Chip · doi:10.1039/d5lc00503e · Cited by 4
Joint‐on‐a‐Chip: The Future of Preclinical Modelling of Joint Diseases
Pye, J. S., Zhang, Y., Lin, X., Yousefi, M., Wen, C., & Li, J. J. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202504487 · Cited by 4
“However, it is worth noting that in workflows with drug response bioassays, the spatiotemporal behaviour of drugs may change when in contact with the channel walls and the inter-channel membranes made of PDMS [57, 58].”
Wang, J., Qiu, S., Lu, H., Yang, F., & Li, G. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.175029 · Cited by 4
Numerical models for organ-on-a-chip: A systematic review and analyses
Su, W., Zhao, Y., Yeboah, S. K., Li, X., & Wang, L. (2025) · Biomicrofluidics · doi:10.1063/5.0260477 · Cited by 3
Development of an acute inhalation toxicity testing method based on a lung-on-a-chip
Kim, G., Han, Y., Bang, I. J., Lim, J. E., & Kim, H. R. (2025) · Lab on a Chip · doi:10.1039/d5lc00693g · Cited by 3
Brás, E. J. S., & Fernandes, P. C. D. B. (2023) · Physical Sciences Reviews · doi:10.1515/psr-2022-0102 · Cited by 3
The utilisation of biliary organoids for biomedical applications
Lei, Z., Yang, Y., & Xiang, Y. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1501829 · Cited by 4
Ryu, J., Lee, J., Kim, K., Lee, Y. J., Kim, J. H., Oh, J., & Kim, J. (2025) · Nano Materials Science · doi:10.1016/j.nanoms.2025.03.004 · Cited by 2
Taleban, H., Li, X., Ali, Z., Kalesh, K., Prakash, J., Onder, T. B., & Breznik, B. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1716813 · Cited by 3
“Inflation layers are particularly important for resolving near-wall shear stress, a variable central to endothelial alignment and barrier integrity (Grant et al., 2021).”
InfluentialLin, C.-M., Mu, H., Chen, C.-T., & Huang, J. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202505347 · Cited by 2
“To address this issue, several mitigation strategies have been proposed, including preconditioning PDMS, quantifying sorption kinetics, and applying correction models to better align in-chip drug exposure with in vivo conditions [131].”
Hydrogel Cardiac Tissue Integrated with Biosensors for Monitoring Cardiac Dysfunction
Zhang, Z., Li, X., Pan, X., Wang, W. J., Zhang, L., Lu, J., Chen, J., Liu, F., & Wang, L. (2026) · ACS Sensors · doi:10.1021/acssensors.5c04591 · Cited by 3
Respiratory Organ‐on‐a‐Chip for Disease Modeling: From Architecture to Functional Integration
Hu, J., Tang, Y., Liu, S., Xu, T., & Liu, Q. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202505908 · Cited by 2
“…136, 176, 182, 183, 269, 270], CF [20, 170], bacterial infection [186, 187, 189, 218, 220], DCS [195], RILI [124], drug concentration simulation [271], bovine lung-on-a-chip development [272], patient-derived AT2 model development [102], drug safety [254], ARDS [260] Chip-R1 Chip validation…”
Mirlohi, M. S., Akar, S., Yazdani, K., Sardroud, H. A., Fardindoost, S., Taemeh, M. A., Achuthan, M., Singh, S., Tibbits, G. F., Hadjati, J., et al. (2026) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2026.115865 · Cited by 4
Reconstituting Cytoarchitecture and Function of Human Epithelial Tissues on an Open-Top Organ-Chip
Antonio, V., Panchal, A., Kasendra, M. J., & Barrile, R. (2023) · Journal of Visualized Experiments · doi:10.3791/64633 · Cited by 2
Organs-on-a-Chip in Preclinical Studies
Parvatam, S., & Chavali, P. L. (2022) · Springer eBooks · doi:10.1007/978-981-19-1379-2_23 · Cited by 2
Carvalho, V. M., Rodrigues, N., Sousa, P. J., Pinto, V. C., Rodrigues, C. S., Shin, S. R., Bañobre‐López, M., Minas, G. M. H., Rodrigues, R. O., Lima, R. A., et al. (2024) · Experimental and Computational Multiphase Flow · doi:10.1007/s42757-024-0216-z · Cited by 1
“…advancements, several challenges persist in the field, including the precise understanding of glucose and drug distribution (Barisam et al., 2017; Grant et al., 2021; Hassanzadeganroudsari et al., 2020; Hu and Li, 2007; Komen et al., 2020; Lee et al., 2018), oxygen availability (Song et al.,…”
A kidney organoid chip facilitating organoid development and in vitro renal fibrosis modeling
Yao, X., Li, Y., Gao, Y., Zhou, L., Bai, Y., Yang, B., Feng, L., Wang, L., Liu, L., & Shi, Y. (2026) · Biomicrofluidics · doi:10.1063/5.0296663 · Cited by 2
Advanced fabrication protocol of an elastic porous membrane for organ-on-a-chip applications
Than, N., & Kim, H. J. (2026) · SLAS TECHNOLOGY · doi:10.1016/j.slast.2026.100431 · Cited by 1
“Despite this limitation, drug loss due to adsorption and absorption can be estimated and accounted for using established transport models based on diffusion and partitioning principles [38].”
Dadhich, A., Sharma, V., & Sivanesan, I. (2026) · Plants · doi:10.3390/plants15142179 · Cited by 2
“…phytohormones, can distort gradient profiles in plant microfluidic channels, as modelled by Grant et al. (2021) for organ-chip drug concentrations [41]. mandating surface treatment protocols Taken together, the physics of microscale flow and transport do not merely constrain device design; they…”
Kang, S. J., Bong, S. H., Jo, M. J., Lee, J. M., Yoon, M. S., Park, S., Lee, Y., Shin, Y., Lee, H. J., Park, C., et al. (2026) · Pharmaceutics · doi:10.3390/pharmaceutics18091117 · Cited by 1
“Drug adsorption to device materials, particularly polydimethylsiloxane (PDMS), may alter effective exposure levels and requires compound-specific validation [30–34].”
Park, W., Jin, Y., Park, E., Byeon, M., Kyung, S. Y., Maeng, Y., Yi, H., Ahn, J., Bang, S., & Ko, J. (2026) · Materials Today Advances · doi:10.1016/j.mtadv.2026.100954 · Cited by 1
Metadata
- Authors
- Grant, J., Özkan, A., Oh, C., Mahajan, G., Prantil-Baun, R., & Ingber, D. E.
- Affiliations
- Harvard University (US)
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
- Boston Children's Hospital (US)
- Corresponding author
- Ingber, Donald E.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2021
- Volume
- 21
- Issue
- 18
- Pages
- 3509-3519
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- PMC
- PMC8440455
- OpenAlex
- W3185033129
- Semantic Scholar
- 8b75cb162159f2e6edd630505e87e61496a41583
- Cited by
- 133
- References
- 41
- Citations by year
- 2026: 41 · 2025: 24 · 2024: 25 · 2023: 21 · 2022: 18 · 2021: 4
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Licence
- Locations
- Lab on a Chip (publishedVersion)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Defense Advanced Research Projects Agency (HR0011-19-2-0008/AWD-102840-612, W911NF-16-C-0050)
- National Center for Advancing Translational Sciences (1-UH3-HL-141797-01)
- Hansjörg Wyss Institute for Biologically Inspired Engineering
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- organ-on-a-chip, PDMS microfluidics, drug diffusion, drug testing, partition coefficient
- MeSH terms
- COVID-19, SARS-CoV-2, Dimethylpolysiloxanes, Pharmaceutical Preparations, Humans, Microfluidics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.