Simulating drug concentrations in PDMS microfluidic organ chips
Open accessPublished version of a preprint
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
microfluidic model to simulate the spatial and temporal gradient of a drug in 3D without prior knowledge of the partition coefficient or the rate of diffusion in PDMS. Thus, this approach may expand the use of PDMS Organ Chip devices for various forms of drug testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“often relying on polydimethylsiloxane or other highly drug-adsorbent materials.23 These materials can lead to artifactual observations in drug effects and kinetics, potentially compromising the reliability of experimental results.”
From A High-Throughput Microphysiological Liver Chip System to Model Drug-Induced Liver Injury Using Human Liver Organoids (2024) · cites this paper as [23]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationDrugBank: a comprehensive resource for in silico drug discovery and exploration
Wishart, D. S. (2006) · Nucleic Acids Research · doi:10.1093/nar/gkj067 · Cited by 3,892
QSAR Modeling: Where have you been? Where are you going to?
Cherkasov, A., Muratov, E. N., Fourches, D., Varnek, A., Baskin, I. I., Cronin, M., Dearden, J., Gramatica, P., Martin, Y. C., Todeschini, R., et al. (2014) · Journal of Medicinal Chemistry · doi:10.1021/jm4004285 · Cited by 2,164
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Self-citationQuantum-Chemical Descriptors in QSAR/QSPR Studies
Karelson, M., Lobanov, V. S., & Katritzky, A. R. (1996) · Chemical Reviews · doi:10.1021/cr950202r · Cited by 1,622
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Self-citationSmall airway-on-a-chip enables analysis of human lung inflammation and drug responses in vitro
Benam, K. H., Villenave, R., Lucchesi, C., Varone, A., Hubeau, C., Lee, H.-H., Alves, S. E., Salmon, M., Ferrante, T. C., Weaver, J. C., et al. (2016) · Nature Methods · doi:10.1038/nmeth.3697 · Cited by 816
Self-citationSmall molecule absorption by PDMS in the context of drug response bioassays
van Meer, B. J., de Vries, H., Firth, K. S. A., van Weerd, J., Tertoolen, L. G. J., Karperien, H. B. J., Jonkheijm, P., Denning, C., IJzerman, A. P., & Mummery, C. L. (2017) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2016.11.062 · Cited by 502
Herland, A., Maoz, B. M., Das, D., Somayaji, M. R., Prantil-Baun, R., Novak, R., Cronce, M., Huffstater, T., Jeanty, S. S. F., Ingram, M., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0498-9 · Cited by 500
Self-citation
Cited by
Items 101–144 of 144
Peng, K., Wang, R., & Zhou, J. (2023) · RSC Advances · doi:10.1039/d3ra00696d · Cited by 1
Organ-on-chip models for pulmonary permeability studies
Lee, D., & Chambers, M. A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15510-9.00018-9 · Cited by 2
Buck, F., Bugter, J., Kruckenbaum, G., Staecker, I., Harzi, M., Lavrentieva, A. V., & Winkler, T. E. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.05.22.727128 · Cited by 1
“The magnitude and impact of this strongly depends on the specific experimental design and question,[19] and its effects may be adjusted for computationally, [20] or by surface modification,[21], [22] but this naturally presents a concern for studies of toxicity or therapeutic efficacy.”
A review on biomimetic models based on microfluidic devices for drug research
Seo, H. H., & Woo, S. H. (2024) · Medical Lasers · doi:10.25289/ml.23.044
Quttina, M., McPhail, D. K., Eisenbrandt, M., Alshamsi, F. Y., Friguglietti, J., James, D., Quintela, M., Raghunathan, V., Bawa‐Khalfe, T., Francis, L. W., et al. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4807926
Research on Microsphere Counting Method Based on Microfluidic Chip
夏, 新. (2024) · Journal of Advances in Physical Chemistry · doi:10.12677/japc.2024.132014
Nazari, H., Asbagh, R. A., Abasipanah, P., Nazari, Z., & Warkiani, M. E. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-27345-2.00007-2
Tebaldi, B., da Silva, P. Y. O. A., de Almeida, D. C., Silva, L., & Balbino, T. A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-13403-6.00001-5
Release, Transfer, Fold: Using a Silicone Adhesive for On-Demand 3D Tissue Engineering
Roth, D., Zampa, B., Augustin, R., Payandehjoo, D., Porcella, G., Şahin, A. T., van der Does, A. M., & Nawroth, J. C. (2025) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5c01130
Huang, Y., Zhang, Z., Sun, C., Wen, L., Wang, Q., & Yang, Y. (2025) · Toxics · doi:10.3390/toxics13110970
“Passive sampling techniques serve as important tools for assessing bioavailable concentrations, including equilibrium-based samplers (e.g., PDMS) [25] and kinetic-based devices (e.g., ChemCatcher [26] and DGT [27]).”
Albishri, A. (2024) · Dipòsit Digital de la Universitat de Barcelona (Universitat de Barcelona)
Polymer sorbent materials for the extraction of organic compounds
Cartmell, D. (2023) · ORCA Online Research @Cardiff (Cardiff University)
Surface properties of polydimethylsiloxane with solvent transport: The effect of ion irradiation
Lee, J.-E., Zheng, K.-Y., Chiang, D., Chang, S.-Y., & Lee, S. (2025) · Polymer · doi:10.1016/j.polymer.2025.129478
Jin, A., Shim, S. W., Shim, M., Lee, Y. K., Hong, J., Roh, D., Hyung, S., Oh, S. B., & Jeon, N. L. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202504121
Advances in microfluidic devices for hemodialysis: Current Trends and Future PerspectivePreprint
Mehdi, S. M. H., & Li, C. W. (2026) · ChemRxiv · doi:10.26434/chemrxiv.15001114/v1
Inaam, R., Mohammad, I. H., Yamamoto, H., Bolontrade, M. F., Okamoto, S., Shibata, T., Santra, T. S., & Nagai, M. (2026) · Applied Sciences · doi:10.3390/app16063040
Delaney, W. H., Faulkner, S. A., Lam, W. A., Boulis, N. M., Qiu, Y., & Lei, K. (2026) · Materials Today Advances · doi:10.1016/j.mtadv.2026.100770
“PDMS sorbs small lipophilic molecules, which reduce free drug concentration and can shift dose response curves in perfused OoCs [99,108, 109].”
Thermoplastic elastomer based microfluidic gradient generator for cell culture and drug testing
Li, K., Moon, B., Clime, L., Lukic, L., Morton, K. J., Malic, L., David, A., Faure, C. C., & Veres, T. (2026) · Biomedical Microdevices · doi:10.1007/s10544-026-00816-y
Yan, L. (2026) · Advances in Clinical Medicine · doi:10.12677/acm.2026.1641743
Advances in microfluidic devices for hemodialysis: Current Trends and Future PerspectivePreprint
Mehdi, S. M. H., Li, C. W., & Mehdi, S. M. H. (2026) · ChemRxiv · doi:10.26434/chemrxiv.15001114/v2
Wei, W. W., Stano, M., Kritzer, B., Nazarian, J., Hierlemann, A. R., & Modena, M. M. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01268-3 · Cited by 1
“However, the absorption of small hydrophobic molecules from media and the sequestering of compounds by PDMS 44,48 strongly limit the application of PDMS-made systems and platforms in drug discovery and testing, as these effects may lead to a misrepresentation of compound toxicity and ef fi cacy.”
Qin, X., Zhao, Y., Wu, Y., Efelis, A., Paul, R., Islam, K., Marquez, C. S., Liu, Y., & Liu, Y. (2026) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5c01908
Development of Human iPSC-based Microphysiogical Models of Transthyretin Amyloid CardiomyopathyPreprint
Williams, M. A. C., Park, J., Mulay, A. R., Mair, D. B., Lysaker, C. R., Jani, V., McKoy, D., Rhodehamel, M., Garg, P., Wu, A., et al. (2026) · Research Square · doi:10.21203/rs.3.rs-9636540/v1
“Polydimethylsiloxane (PDMS) was selected as the device material for its optical transparency, elasticity, and biocompatibility 27–29 and was cast into the mold to produce chips with dedicated organoid chambers and interconnecting microchannels that permit soluble factor exchange, thereby simulating…”
Bang, I. J., Kim, M.-S., Han, Y., Kim, G. E., Lim, J. E., Park, J. Y., Yoo, J., Jang, Y. S., 이, 범., Kwak, M., et al. (2026) · Toxicological Research · doi:10.1007/s43188-026-00372-w · Cited by 1
“Such adsorption-induced losses can distort pharmacokinetic and pharmacodynamic (PK/PD) measurement results, complicate the establishment of accurate dose–response curves, and ultimately reduce the predictive reliability of organ-on-a-chip systems used for drug evaluation [289].”
Jiang, X., Peng, D., Li, M., Yang, J., Ma, F., Yang, Q., & Huo, Q. (2026) · Materials Today Advances · doi:10.1016/j.mtadv.2026.100884 · Cited by 2
Vetter, J., Fritschen, A., Teppe, L., Mandal, S., Abbood, N., Filatova, A., Singh, V., von Klitzing, R., Hecker, A., Grau, V., et al. (2026) · Biomaterials · doi:10.1016/j.biomaterials.2026.124453
An LCD 3D-printed microphysiological system with deflectable extracellular matrix thin films
Nelson, M. D., Tresco, P. A., Razaghian, A., Mercer, C., Yost, C. C., & Gale, B. K. (2026) · Biomedical Materials · doi:10.1088/1748-605x/ae8e15
“In fact, groups using PDMS have employed simulations and diffusivity measurements as an attempt to correct for drug absorption quantitatively [20].”
A millifluidic human gut model with peristalsis orchestrates villus morphogenesis
Daddi, C., Maharjan, S., Scalzo, S., Anaya, S. N., Falugiani, L., Machain, X. H., Lobo, A. O., Fortunato, G. M., Maria, C. D., Zhang, Y. S., et al. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.112189
Bello, A., Sule, Z., Musa, I., Adeyemi, G., & Youssef, A. (2026) · Pharmacophore · doi:10.51847/0rccab9zhh
Nanomaterial‐Based Electrochemical Sensors for Cell Analysis in Microphysiological Systems
Sari, S. R., Hiramoto, K., & Ino, K. (2026) · Analysis & Sensing · doi:10.1002/anse.70110
Liver-on-a-chip: Applications for clinical modeling of liver disease using microscale systems
Brooks, N. M., Peczak, A., & Schwartz, R. E. (2026) · Hepatology · doi:10.1097/hep.0000000000001829
Hernández-Castro, J. A., Lussier, F., Malic, L., Geißler, M., Kim, T.-H., Moon, B., Li, K., Zhao, Y., Clime, L., Brassard, D., et al. (2026) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2026.115945
Integration of biological avatars and digital twins for “ex vivo clinical trials”
Howe, C. L. (2026) · EBioMedicine · doi:10.1016/j.ebiom.2026.106467
“…are built: its transparency and gas permeability are useful, but it absorbs hydrophobic small molecules and thereby distorts drug exposure and pharmacokinetic readouts, 51 which can require coatings, alternative materials such as thermoplastics or glass, or materials-aware computational correction.”
In vitro approaches for modelling gut-liver crosstalk in drug-induced liver injury
Janssen, Y., Jiang, J., Vandeputte, D., & Vinken, M. (2026) · Archives of Toxicology · doi:10.1007/s00204-026-04537-2
Wang, X., Wang, Q., Wang, J., Ding, G., Huang, Y., Feng, Y., & Zou, B. (2026) · Materials Today Advances · doi:10.1016/j.mtadv.2026.100976
Li, X., Li, Y., Xu, J., Sun, R., Liu, W., Chen, X., Zhu, L., Zhao, Q., Li, J., Li, Y., et al. (2026) · Biosensors · doi:10.3390/bios16100547
“Utilizing the tunable elasticity of PDMS, the membrane can undergo periodic deformation driven by pneumatic actuation, simulating the cyclic expansion and recoil of alveoli during breathing [62,63].”
Sensor-Integrated Organ-on-a-Chip Platforms: Advances in Drug Evaluation and Disease Modeling
Huang, Z., Zhang, Y., Li, Y., Li, Y., Xue, Z., Chen, M., Li, W., Li, W., Zhang, Y., Zheng, L., et al. (2026) · ACS Sensors · doi:10.1021/acssensors.6c00932
Dlamini, N., Zulu, S., Nkosi, T., & Molefe, L. (2026) · International Journal of Pharmaceutical and Phytopharmacological Research · doi:10.51847/ihw30osyk2
Avci, M. B., Kocer, F., Topkaya, S. N., Papatryfonos, K., & Çetin, A. E. (2026) · Nanotechnology · doi:10.1088/1361-6528/aeb131
Materials for liver-on-a-chip: modules, properties, and future directions
Wang, H.-R., Li, J.-X., Wan, C., Zhou, J., & Bao, N. (2026) · Microchimica Acta · doi:10.1007/s00604-026-08448-y
“Toxicity studies should therefore include cell-free controls, pre-saturation, time-series sampling, and mass-balance analysis, and report the recovery of a standard hydrophobic drug [159, 160].”
Overcoming challenges in microfluidic nanomedicine: From bench to bedside
Rahmani, M., Khorrami, F. M., & Moridan, F. Z. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-45538-4.00008-x
Advances in engineering organ-on-a-chip models of angiogenesis
Tao, Y., Liu, T., Zhang, Y., Yue, H., Zhang, H., 赁可, Wu, C., Huang, Y., Liu, X., Wang, X., et al. (2026) · Theranostics · doi:10.7150/thno.136769
“…and bulk absorption, causing the concentration reaching cells to deviate from the nominal medium concentration; therefore, researchers have developed simulation-based and experimental approaches to estimate the spatial and temporal concentration profiles of drugs in PDMS organ chips [80].”
InfluentialMancinelli, E., Slay, E., & Pensabene, V. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-16110-0.00013-3
Microfluidic engineering for organoid formation, cultivation, and sensing
Kushnir, I. A., Salina, K. O., Bogolubova, Y. A., Mushegian, T. M., Dragun, M. A., Volegova, D. D., Polynkin, L. Y., Kopylova, A. A., Salmina, A. B., & Yurchenko, S. O. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1994650
Metadata
- Authors
- Grant, J., Özkan, A., Oh, C., Mahajan, G., Prantil-Baun, R., & Ingber, D. E.
- Affiliations
- Harvard University (US)
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
- Boston Children's Hospital (US)
- Corresponding author
- Ingber, Donald E.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2021
- Volume
- 21
- Issue
- 18
- Pages
- 3509-3519
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- PMC
- PMC8440455
- OpenAlex
- W3185033129
- Semantic Scholar
- 8b75cb162159f2e6edd630505e87e61496a41583
- Cited by
- 133
- References
- 41
- Citations by year
- 2026: 41 · 2025: 24 · 2024: 25 · 2023: 21 · 2022: 18 · 2021: 4
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Licence
- Locations
- Lab on a Chip (publishedVersion)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Defense Advanced Research Projects Agency (HR0011-19-2-0008/AWD-102840-612, W911NF-16-C-0050)
- National Center for Advancing Translational Sciences (1-UH3-HL-141797-01)
- Hansjörg Wyss Institute for Biologically Inspired Engineering
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- organ-on-a-chip, PDMS microfluidics, drug diffusion, drug testing, partition coefficient
- MeSH terms
- COVID-19, SARS-CoV-2, Dimethylpolysiloxanes, Pharmaceutical Preparations, Humans, Microfluidics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.