The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Directed evolution of a monomeric, bright and photostable version of Clavularia cyan fluorescent protein: structural characterization and applications in fluorescence imaging
Open accessAbstract
The arsenal of engineered variants of the GFP [green FP (fluorescent protein)] from Aequorea jellyfish provides researchers with a powerful set of tools for use in biochemical and cell biology research. The recent discovery of diverse FPs in Anthozoa coral species has provided protein engineers with an abundance of alternative progenitor FPs from which improved variants that complement or supersede existing Aequorea GFP variants could be derived. Here, we report the engineering of the first monomeric version of the tetrameric CFP (cyan FP) cFP484 from Clavularia coral. Starting from a designed synthetic gene library with mammalian codon preferences, we identified dimeric cFP484 variants with fluorescent brightness significantly greater than the wild-type protein. Following incorporation of dimer-breaking mutations and extensive directed evolution with selection for blue-shifted emission, high fluorescent brightness and photostability, we arrived at an optimized variant that we have named mTFP1 [monomeric TFP1 (teal FP 1)]. The new mTFP1 is one of the brightest and most photostable FPs reported to date. In addition, the fluorescence is insensitive to physiologically relevant pH changes and the fluorescence lifetime decay is best fitted as a single exponential. The 1.19 Å crystal structure (1 Å=0.1 nm) of mTFP1 confirms the monomeric structure and reveals an unusually distorted chromophore conformation. As we experimentally demonstrate, the high quantum yield of mTFP1 (0.85) makes it particularly suitable as a replacement for ECFP (enhanced CFP) or Cerulean as a FRET (fluorescence resonance energy transfer) donor to either a yellow or orange FP acceptor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
[20] Processing of X-ray diffraction data collected in oscillation mode
Otwinowski, Z., & Minor, W. (1997) · Methods in Enzymology · doi:10.1016/s0076-6879(97)76066-x · Cited by 33,475
Coot : model-building tools for molecular graphics
Emsley, P., & Cowtan, K. (2004) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444904019158 · Cited by 30,571
PROCHECK: a program to check the stereochemical quality of protein structures
Laskowski, R. A., MacArthur, M. W., Moss, D. S., & Thornton, J. M. (1993) · Journal of Applied Crystallography · doi:10.1107/s0021889892009944 · Cited by 24,581
NMRPipe: A multidimensional spectral processing system based on UNIX pipes
Delaglio, F., Grzesiek, S., Vuister, G., Zhu, G., Pfeifer, J., & Bax, A. (1995) · Journal of Biomolecular NMR · doi:10.1007/bf00197809 · Cited by 15,965
MOLSCRIPT: a program to produce both detailed and schematic plots of protein structures
Kraulis, P. J. (1991) · Journal of Applied Crystallography · doi:10.1107/s0021889891004399 · Cited by 14,085
Tsien, R. Y. (1998) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.67.1.509 · Cited by 6,143
Shaner, N. C., Campbell, R. E., Steinbach, P. A., Giepmans, B. N. G., Palmer, A. E., & Tsien, R. Y. (2004) · Nature Biotechnology · doi:10.1038/nbt1037 · Cited by 4,619
Self-citationProtein Structure Comparison by Alignment of Distance Matrices
Holm, L., & Sander, C. (1993) · Journal of Molecular Biology · doi:10.1006/jmbi.1993.1489 · Cited by 3,984
[26] Raster3D: Photorealistic molecular graphics
Merritt, E. A., & Bacon, D. J. (1997) · Methods in Enzymology · doi:10.1016/s0076-6879(97)77028-9 · Cited by 3,739
Fluorescent indicators for Ca2+based on green fluorescent proteins and calmodulin
Miyawaki, A., Llopis, J., Heim, R., McCaffery, J. M., Adams, J. A., Ikura, M., & Tsien, R. Y. (1997) · Nature · doi:10.1038/42264 · Cited by 3,248
Cited by
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
Fluorescent Proteins and Their Applications in Imaging Living Cells and Tissues
Chudakov, D. M., Matz, M. V., Lukyanov, S., & Lukyanov, K. A. (2010) · Physiological Reviews · doi:10.1152/physrev.00038.2009 · Cited by 1,375
Improving the photostability of bright monomeric orange and red fluorescent proteins
Shaner, N. C., Lin, M. Z., McKeown, M. R., Steinbach, P. A., Hazelwood, K. L., Davidson, M. W., & Tsien, R. Y. (2008) · Nature Methods · doi:10.1038/nmeth.1209 · Cited by 1,009
Fluorescent protein FRET: the good, the bad and the ugly
Piston, D. W., & Kremers, G.-J. (2007) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2007.08.003 · Cited by 849
The fluorescent protein palette: tools for cellular imaging
Day, R. N., & Davidson, M. W. (2009) · Chemical Society Reviews · doi:10.1039/b901966a · Cited by 810
Advances in fluorescent protein technology
Shaner, N. C., Patterson, G. H., & Davidson, M. W. (2007) · Journal of Cell Science · doi:10.1242/jcs.005801 · Cited by 787
Akerboom, J., Carreras Calderón, N., Tian, L., Wabnig, S., Prigge, M., Tolö, J., Gordus, A., Orger, M. B., Severi, K. E., Macklin, J. J., et al. (2013) · Frontiers in Molecular Neuroscience · doi:10.3389/fnmol.2013.00002 · Cited by 719
Two-photon absorption properties of fluorescent proteins
Drobizhev, M., Makarov, N. S., Tillo, S. E., Hughes, T. E., & Rebane, A. (2011) · Nature Methods · doi:10.1038/nmeth.1596 · Cited by 675
Development of an optimized backbone of FRET biosensors for kinases and GTPases
Komatsu, N., Aoki, K., Yamada, M., Yukinaga, H., Fujita, Y., Kamioka, Y., & Matsuda, M. (2011) · Molecular Biology of the Cell · doi:10.1091/mbc.e11-01-0072 · Cited by 577
Quantitative assessment of fluorescent proteins
Cranfill, P. J., Sell, B. R., Baird, M. A., Allen, J. R., Lavagnino, Z., de Gruiter, H. M., Kremers, G.-J., Davidson, M. W., Ustione, A., & Piston, D. W. (2016) · Nature Methods · doi:10.1038/nmeth.3891 · Cited by 497
Review of spectral imaging technology in biomedical engineering: achievements and challenges
Li, Q., He, X., Wang, Y., Liu, H., Xu, D., & Guo, F. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.10.100901 · Cited by 479
A Guide to Fluorescent Protein FRET Pairs
Bajar, B., Wang, E., Zhang, S., Lin, M., & Chu, J. (2016) · Sensors · doi:10.3390/s16091488 · Cited by 463
Xu, C., Gagnon, E., Call, M. E., Schnell, J. R., Schwieters, C. D., Carman, C. V., Chou, J. J., & Wucherpfennig, K. W. (2008) · Cell · doi:10.1016/j.cell.2008.09.044 · Cited by 456
Improved tools for the Brainbow toolbox
Cai, D., Cohen, K. B., Luo, T., Lichtman, J. W., & Sanes, J. R. (2013) · Nature Methods · doi:10.1038/nmeth.2450 · Cited by 426
Measurement of single-cell dynamics
Spiller, D. G., Wood, C. D., Rand, D. A., & White, M. R. H. (2010) · Nature · doi:10.1038/nature09232 · Cited by 411
Genetically Encodable Fluorescent Biosensors for Tracking Signaling Dynamics in Living Cells
Newman, R. H., Fosbrink, M. D., & Zhang, J. (2011) · Chemical Reviews · doi:10.1021/cr100002u · Cited by 353
Fluorescent protein FRET pairs for ratiometric imaging of dual biosensors
Ai, H.-W., Hazelwood, K. L., Davidson, M. W., & Campbell, R. E. (2008) · Nature Methods · doi:10.1038/nmeth.1207 · Cited by 346
Self-citationFluorescent proteins for live-cell imaging with super-resolution
Nienhaus, K., & Ulrich Nienhaus, G. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60171d · Cited by 337
Fluorescent proteins: maturation, photochemistry and photophysics
Remington, S. J. (2006) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2006.10.001 · Cited by 326
Self-citationReaction-Based Genetically Encoded Fluorescent Hydrogen Sulfide Sensors
Chen, S., Chen, Z.-J., Ren, W., & Ai, H.-W. (2012) · Journal of the American Chemical Society · doi:10.1021/ja303261d · Cited by 318
Self-citationAi, H.-W., Shaner, N. C., Cheng, Z., Tsien, R. Y., & Campbell, R. E. (2007) · Biochemistry · doi:10.1021/bi700199g · Cited by 313
Self-citationFluorescence Proteins, Live-Cell Imaging, and Mechanobiology: Seeing Is Believing
Wang, Y., Shyy, J. Y.-J., & Chien, S. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.010308.161731 · Cited by 310
Live-cell microscopy – tips and tools
Frigault, M. M., Lacoste, J., Swift, J. L., & Brown, C. M. (2009) · Journal of Cell Science · doi:10.1242/jcs.033837 · Cited by 304
A highly photostable and bright green fluorescent protein
Hirano, M., Ando, R., Shimozono, S., Sugiyama, M., Takeda, N., Kurokawa, H., Deguchi, R., Endo, K., Haga, K., Takai-Todaka, R., et al. (2022) · Nature Biotechnology · doi:10.1038/s41587-022-01278-2 · Cited by 293
Single Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 292
Rocha, J., Peixe, L., Gomes, N. C. M., & Calado, R. (2011) · Marine Drugs · doi:10.3390/md9101860 · Cited by 274
High-performance probes for light and electron microscopy
Viswanathan, S., Williams, M. E., Bloss, E. B., Stasevich, T. J., Speer, C. M., Nern, A., Pfeiffer, B. D., Hooks, B. M., Li, W.-P., English, B. P., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3365 · Cited by 265
Green fluorescent protein: A perspective
Remington, S. J. (2011) · Protein Science · doi:10.1002/pro.684 · Cited by 260
Self-citationFluorescence lifetime imaging microscopy in life sciences
Borst, J. W., & Visser, A. J. W. G. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/10/102002 · Cited by 168
Voisinne, G., García‐Blesa, A., Chaoui, K., Fiore, F., Bergot, E., Girard, L., Malissen, M., Burlet‐Schiltz, O., Gonzalez de Peredo, A., Malissen, B., et al. (2016) · Molecular Systems Biology · doi:10.15252/msb.20166837 · Cited by 50
Barrel Shape and Chromophore Rigidity Predict Fluorescent-Protein Photophysics
Begg, L. P., Mason, M. L., & Zimmer, M. (2026) · Journal of Chemical Information and Modeling · doi:10.1021/acs.jcim.6c01606 · Cited by 1
Metadata
- Authors
- Ai, H.-W., Henderson, J. N., Remington, S. J., & Campbell, R. E.
- Venue
- Biochemical Journal
- Publisher
- Portland Press Ltd.
- Published
- 2006-11-28
- Volume
- 400
- Issue
- 3
- Pages
- 531-540
- ISSN
- 0264-6021 (ISSN-L)
- 1470-8728
- OpenAlex
- W2118726157
- Cited by
- 390
- References
- 53
- FWCI
- 9.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.