Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 261

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Heart rate variability measures: a fresh look at reliability

Open access
Pinna, Gian Domenico, Maestri, Roberto, Torunski, Antoni, Danilowicz-Szymanowicz, Ludmila, Szwoch, Malgorzata, La Rovere, Maria Teresa, Raczak, Grzegorz · 2007 · Clinical Science

Abstract

Despite its extensive use in physiological and clinical research, the analysis of HRV (heart rate variability) is still poorly supported by rigorous reliability studies. The main aim of the present study was to perform an in-depth assessment of absolute and relative reliability of standard indexes of HRV from short-term laboratory recordings. In 39 healthy subjects [mean age (min–max): 38 (26–56) years; 18 men and 21 women] we recorded 5 min of supine ECG during spontaneous and paced (15 breaths/min) breathing. The test was repeated on the next day under the same conditions. From the RR intervals we computed standard indexes of HRV: SDNN (S.D. of RR interval values), RMSSD (root-mean-square of successive RR interval differences), LF (low frequency) and HF (high frequency) power (absolute and normalized units) and LF/HF. Absolute reliability was assessed by 95% limits of random variation; relative reliability was assessed by the ICC (intraclass correlation coefficient). The sample size needed to detect a mean difference ≥30% of the between-subject S.D. was also estimated. Although there was no significant mean change between the two tests, we found that in individual subjects the second measurement was as high/low as 1.9/0.5 times (SDNN, best case) and 3.5/0.3 times (LF/HF, worst case) the first measurement, due to pure random variation. For most parameters the ICC was >0.8 (range 0.65–0.88). The estimated sample size ranged from 24–98 subjects. Reliability indexes tended to improve during paced breathing. We conclude that short-term HRV parameters are subject to large day-to-day random variations. Random error, however, represents a limited part of the between-subject variability; therefore observed differences between individuals mostly reflect differences in the subjects' error-free value rather than random error. Overall, paced breathing improves reliability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1042/cs20070055

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

Metadata

Authors
Pinna, G. D., Maestri, R., Torunski, A., Danilowicz-Szymanowicz, L., Szwoch, M., La Rovere, M. T., & Raczak, G.
Venue
Clinical Science
Published
2007-07-02
Volume
113
Issue
3
Pages
131-140
ISSN
  • 0143-5221 (ISSN-L)
  • 1470-8736
OpenAlex
W2070421542
Cited by
261
References
34
FWCI
7.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.