The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Heart rate variability measures: a fresh look at reliability
Open accessAbstract
Despite its extensive use in physiological and clinical research, the analysis of HRV (heart rate variability) is still poorly supported by rigorous reliability studies. The main aim of the present study was to perform an in-depth assessment of absolute and relative reliability of standard indexes of HRV from short-term laboratory recordings. In 39 healthy subjects [mean age (min–max): 38 (26–56) years; 18 men and 21 women] we recorded 5 min of supine ECG during spontaneous and paced (15 breaths/min) breathing. The test was repeated on the next day under the same conditions. From the RR intervals we computed standard indexes of HRV: SDNN (S.D. of RR interval values), RMSSD (root-mean-square of successive RR interval differences), LF (low frequency) and HF (high frequency) power (absolute and normalized units) and LF/HF. Absolute reliability was assessed by 95% limits of random variation; relative reliability was assessed by the ICC (intraclass correlation coefficient). The sample size needed to detect a mean difference ≥30% of the between-subject S.D. was also estimated. Although there was no significant mean change between the two tests, we found that in individual subjects the second measurement was as high/low as 1.9/0.5 times (SDNN, best case) and 3.5/0.3 times (LF/HF, worst case) the first measurement, due to pure random variation. For most parameters the ICC was >0.8 (range 0.65–0.88). The estimated sample size ranged from 24–98 subjects. Reliability indexes tended to improve during paced breathing. We conclude that short-term HRV parameters are subject to large day-to-day random variations. Random error, however, represents a limited part of the between-subject variability; therefore observed differences between individuals mostly reflect differences in the subjects' error-free value rather than random error. Overall, paced breathing improves reliability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
The Design and Analysis of Clinical Experiments
Fleiss, J. L. (1999) · Wiley eBooks · doi:10.1002/9781118032923 · Cited by 4,819
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
The Design and Analysis of Clinical Experiments.
Hills, M., & Fleiss, J. L. (1987) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2982050 · Cited by 3,261
Sample size requirements for reliability studies
Donner, A., & Eliasziw, M. (1987) · Statistics in Medicine · doi:10.1002/sim.4780060404 · Cited by 699
Effect of aging on gender differences in neural control of heart rate
Kuo, T. B. J., Lin, T., Yang, C. C. H., Li, C.-L., Chen, C.-F., & Chou, P. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.6.h2233 · Cited by 562
Fundamentals of Modern Statistical Methods: Substantially Improving Power and Accuracy
Wilcox, R. R. (2010) · doi:10.1007/978-1-4419-5525-8 · Cited by 404
Parati, G., Mancia, G., Rienzo, M. D., & Castiglioni, P. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00446.2006 · Cited by 325
Review papers : Design and analysis of reliability studies
Dunn, G. (1992) · Statistical Methods in Medical Research · doi:10.1177/096228029200100202 · Cited by 325
The reliability of short-term measurements of heart rate variability
Sandercock, G. R. H., Bromley, P. D., & Brodie, D. A. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.09.013 · Cited by 307
Sinnreich, R., Kark, J. D., Friedlander, Y., Sapoznikov, D., & Luria, M. H. (1998) · Heart · doi:10.1136/hrt.80.2.156 · Cited by 292
(1990) · Elsevier eBooks · doi:10.1016/c2009-0-22298-7 · Cited by 256
Does Autonomic Function Link Social Position to Coronary Risk?: The Whitehall II Study
Hemingway, H., Shipley, M., Brunner, E., Britton, A., Malik, M., & Marmot, M. (2005) · Circulation · doi:10.1161/circulationaha.104.497347 · Cited by 230
Design and Analysis of Reliability Studies: The Statistical Evaluation of Measurement Errors.
Ackerman, T. A., & Dunn, G. (1991) · Journal of the American Statistical Association · doi:10.2307/2290615 · Cited by 182
Repeatability of heart rate variability measures
Schroeder, E. B., Whitsel, E. A., Evans, G. W., Prineas, R. J., Chambless, L. E., & Heiss, G. (2004) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2004.04.004 · Cited by 170
Design and analysis of reliability studies: the statistical evaluation of measurement errors
(1990) · Choice Reviews Online · doi:10.5860/choice.27-6381 · Cited by 169
Pitzalis, M. (1996) · Cardiovascular Research · doi:10.1016/0008-6363(96)00086-7 · Cited by 162
Pinna, G. D., Maestri, R., Rovere, M. T. L., Gobbi, E., & Fanfulla, F. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00438.2005 · Cited by 129
Self-citationEffect of athletic training on heart rate variability
Sacknoff, D. M., Gleim, G. W., Stachenfeld, N. S., & Coplan, N. L. (1994) · American Heart Journal · doi:10.1016/0002-8703(94)90046-9 · Cited by 127
Design and Analysis of Reliability Studies: The Statistical Evaluation of Measurement Errors.
Kühnel, S., & Dunn, G. (1991) · Contemporary Sociology A Journal of Reviews · doi:10.2307/2073785 · Cited by 94
Gerritsen, J., TenVoorde, B. J., Dekker, J. M., Kingma, R., Kostense, P. J., Bouter, L. M., & Heethaar, R. M. (2003) · Diabetologia · doi:10.1007/s00125-003-1032-9 · Cited by 84
Application of time series spectral analysis theory: analysis of cardiovascular variability signals
Pinna, G. D., Maestri, R., & Cesare, A. D. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02520019 · Cited by 78
Self-citationLORD, S. W., SENIOR, R. R., Das, M., Whittam, A. M., Murray, A., & McComb, J. M. (2000) · Clinical Science · doi:10.1042/cs20000111 · Cited by 67
POLYAN: A computer program for polyparametric analysis of cardio-respiratory variability signals
Maestri, R., & Pinna, G. D. (1998) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(98)00004-2 · Cited by 59
Self-citationEnhanced cardiac vagal efferent activity does not explain training-induced bradycardia
Scott, A. S., Eberhard, A., Ofir, D., Benchetrit, G., Pham, D.-T., Calabrèse, P., Lesiuk, V., & Perrault, H. (2004) · Autonomic Neuroscience · doi:10.1016/j.autneu.2004.04.006 · Cited by 39
SANDERCOCK, G. R. H., Bromley, P. D., & Brodie, D. A. (2004) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2004.00584.x · Cited by 38
Fundamentals of Modern Statistical Methods
Babu, G. J. (2002) · Technometrics · doi:10.1198/tech.2002.s653 · Cited by 26
Pinna, G. D., Maestri, R., & Sanarico, M. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.503184 · Cited by 16
Self-citation
Cited by
NUNAN, D., SANDERCOCK, G. R. H., & BRODIE, D. A. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02841.x · Cited by 874
Considerations in the assessment of heart rate variability in biobehavioral research
Quintana, D. S., & Heathers, J. A. J. (2014) · Frontiers in Psychology · doi:10.3389/fpsyg.2014.00805 · Cited by 395
Methods of evaluation of autonomic nervous system function
Zygmunt, A., & Stanczyk, J. (2010) · Archives of Medical Science · doi:10.5114/aoms.2010.13500 · Cited by 346
“Analysis of heart rate variability Analysis of heart rate variability (HRV) has nowadays become one of the most popular methods of autonomic nervous system evaluation.”
BackgroundInfluentialMelillo, P., Bracale, M., & Pecchia, L. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-96 · Cited by 328
Validity and Reliability of Short-Term Heart-Rate Variability from the Polar S810
NUNAN, D., DONOVAN, G., JAKOVLJEVIC, D. G., HODGES, L. D., SANDERCOCK, G. R. H., & BRODIE, D. A. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318184a4b1 · Cited by 302
Metadata
- Authors
- Pinna, G. D., Maestri, R., Torunski, A., Danilowicz-Szymanowicz, L., Szwoch, M., La Rovere, M. T., & Raczak, G.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 2007-07-02
- Volume
- 113
- Issue
- 3
- Pages
- 131-140
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W2070421542
- Cited by
- 261
- References
- 34
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.