Lateral flow assays
Open accessAbstract
Lateral flow assays (LFAs) are the technology behind low-cost, simple, rapid and portable detection devices popular in biomedicine, agriculture, food and environmental sciences. This review presents an overview of the principle of the method and the critical components of the assay, focusing on lateral flow immunoassays. This type of assay has recently attracted considerable interest because of its potential to provide instantaneous diagnosis directly to patients. The range and interpretation of results and parameters used for evaluation of the assay will also be discussed. The main advantages and disadvantages of LFAs will be summarized and relevant future improvements to testing devices and strategies will be proposed. Finally, the major recent advances and future diagnostic applications in the LFA field will be explored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Li, Z., Wang, Y., Wang, J., Tang, Z., Pounds, J. G., & Lin, Y. (2010) · Analytical Chemistry · doi:10.1021/ac101405a · Cited by 424
Ngom, B., Guo, Y., Wang, X., & Bi, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3661-4 · Cited by 386
Disposable Nucleic Acid Biosensors Based on Gold Nanoparticle Probes and Lateral Flow Strip
Mao, X., Ma, Y., Zhang, A., Zhang, L., Zeng, L., & Liu, G. (2009) · Analytical Chemistry · doi:10.1021/ac8024653 · Cited by 344
Enhanced lateral flow immunoassay using gold nanoparticles loaded with enzymes
Parolo, C., de la Escosura-Muñiz, A., & Merkoçi, A. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.06.049 · Cited by 331
Moreno, M. D. L., Cebolla, Á., Muñoz-Suano, A., Carrillo-Carrion, C., Comino, I., Pizarro, Á., León, F., Rodríguez-Herrera, A., & Sousa, C. (2017) · Gut · doi:10.1136/gutjnl-2015-310148 · Cited by 317
Yen, C.-W., de Puig, H., Tam, J. O., Gómez-Márquez, J., Bosch, I., Hamad-Schifferli, K., & Gehrke, L. (2015) · Lab on a Chip · doi:10.1039/c5lc00055f · Cited by 308
Ren, M., Xu, H., Huang, X., Kuang, M., Xiong, Y., Xu, H., Xu, Y., Chen, H., & Wang, A. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am503517s · Cited by 255
Colloidal gold-based immunochromatographic assay for detection of ricin
Shyu, R.-H., Shyu, H.-F., Liu, H.-W., & Tang, S.-S. (2002) · Toxicon · doi:10.1016/s0041-0101(01)00193-3 · Cited by 246
Liu, C., Jia, Q., Yang, C., Qiao, R., Jing, L., Wang, L., Xu, C., & Gao, M. (2011) · Analytical Chemistry · doi:10.1021/ac201462d · Cited by 233
Significantly Improved Analytical Sensitivity of Lateral Flow Immunoassays by Using Thermal Contrast
Qin, Z., Chan, W. C. W., Boulware, D. R., Akkin, T., Butler, E. K., & Bischof, J. C. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200997 · Cited by 221
Morales-Narváez, E., Naghdi, T., Zor, E., & Merkoçi, A. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02383 · Cited by 186
A Lateral Flow Assay for Quantitative Detection of Amplified HIV-1 RNA
Rohrman, B. A., Leautaud, V., Molyneux, E., & Richards-Kortum, R. R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0045611 · Cited by 178
Lin, Y.-Y., Wang, J., Liu, G., Wu, H., Wai, C. M., & Lin, Y. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.01.037 · Cited by 174
Fluorescent Probe-Based Lateral Flow Assay for Multiplex Nucleic Acid Detection
Xu, Y., Liu, Y., Wu, Y., Xia, X., Liao, Y., & Li, Q. (2014) · Analytical Chemistry · doi:10.1021/ac5010458 · Cited by 171
The Current Status of Sweat Testing For Drugs of Abuse: A Review
De Giovanni, N., & Fucci, N. (2013) · Current Medicinal Chemistry · doi:10.2174/092986713804910139 · Cited by 164
Detection of Early Pregnancy Forms of Human Chorionic Gonadotropin by Home Pregnancy Test Devices
Butler, S. A., Khanlian, S. A., & Cole, L. A. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.12.2131 · Cited by 154
Increased sensitivity of lateral flow immunoassay for ochratoxin A through silver enhancement
Anfossi, L., Nardo, F. D., Giovannoli, C., Passini, C., & Baggiani, C. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7428-6 · Cited by 143
Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection
Carrio, A., Sampedro, C., Sánchez-López, J. L., Pimienta, M., & Campoy, P. (2015) · Sensors · doi:10.3390/s151129569 · Cited by 140
The 12th International Conference on Miniaturized Systems for Chemistry and Life Sciences
(2008) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2008.921835 · Cited by 139
Mei, Z., Qu, W., Deng, Y. H., Chu, H., Cao, J., Xue, F., Zheng, L., El-Nezami, H. S., Wu, Y., & Chen, W. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.06.006 · Cited by 110
Maiolini, E., Ferri, E. N., Pitasi, A. L., Montoya, A., Giovanni, M. D., Errani, E., & Girotti, S. (2013) · The Analyst · doi:10.1039/c3an00552f · Cited by 94
Leung, W., Chan, C. P.-Y., Rainer, T. H., Ip, M., Cautherley, G. W. H., & Renneberg, R. (2008) · Journal of Immunological Methods · doi:10.1016/j.jim.2008.03.009 · Cited by 87
Mirasoli, M., Buragina, A., Dolci, L. S., Guardigli, M., Simoni, P., Montoya, Á., Maiolini, E., Girotti, S., & Roda, A. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.01.036 · Cited by 74
Rapid detection of HIV-1 p24 antigen using magnetic immuno-chromatography (MICT)
Workman, S., Wells, S. K., Pau, C., Owen, S. M., Dong, X., LaBorde, R., & Granade, T. C. (2009) · Journal of Virological Methods · doi:10.1016/j.jviromet.2009.04.003 · Cited by 73
Magambo, K. A., Kalluvya, S. E., Kapoor, S. W., Seni, J., Chofle, A. A., Fitzgerald, D. W., & Downs, J. A. (2014) · Journal of the International AIDS Society · doi:10.7448/ias.17.1.19040 · Cited by 68
Ang, S. H., Rambeli, M., Thevarajah, T. M., Alias, Y. B., & Khor, S. M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.045 · Cited by 57
A quantitative lateral flow assay to detect complement activation in blood
Schramm, E. C., Staten, N. R., Zhang, Z., Bruce, S. S., Kellner, C. P., Atkinson, J. P., Kyttaris, V. C., Tsokos, G. C., Petri, M., Connolly, E. S., et al. (2015) · Analytical Biochemistry · doi:10.1016/j.ab.2015.01.024 · Cited by 55
Barcode lateral flow immunochromatographic strip for prostate acid phosphatase determination
Fang, C., Chen, Z., Li, L., & Xia, J.-H. (2011) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2011.08.008 · Cited by 55
Sweat Testing of MDMA with the Drugwipe(R) Analytical Device: A Controlled Study with Two Volunteers
Pacifici, R., Farré, M., Pichini, S., et al. (2001) · Journal of Analytical Toxicology · doi:10.1093/jat/25.2.144 · Cited by 50
Kamphee, H., Chaiprasert, A., Prammananan, T., Wiriyachaiporn, N., Kanchanatavee, A., & Dharakul, T. (2015) · PLoS ONE · doi:10.1371/journal.pone.0137791 · Cited by 49
Detection of Shiga Toxins by Lateral Flow Assay
Ching, K. H., He, X., Stanker, L. H., Lin, A. V., McGarvey, J. A., & Hnasko, R. M. (2015) · Toxins · doi:10.3390/toxins7041163 · Cited by 37
Development of Prototype Filovirus Recombinant Antigen Immunoassays
Boisen, M. L., Oottamasathien, D., Jones, A. B., Millett, M. M., Nelson, D. S., Bornholdt, Z. A., Fusco, M. L., Abelson, D. M., Oda, S.-I., Hartnett, J. N., et al. (2015) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiv353 · Cited by 37
He, Y., Zhang, X., Zhang, S., Kris, M. K. L., Man, F. C., Kawde, A.-N. M., & Liu, G. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.12.055 · Cited by 36
Cited by
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Yu, H., Alkhamis, O., Canoura, J., Liu, Y., & Xiao, Y. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202008663 · Cited by 492
Nucleic Acid Detection Using CRISPR/Cas Biosensing Technologies
Aman, R., Mahas, A., & Mahfouz, M. (2020) · ACS Synthetic Biology · doi:10.1021/acssynbio.9b00507 · Cited by 409
Safiabadi Tali, S. H., LeBlanc, J. J., Sadiq, Z., Oyewunmi, O. D., Camargo, C., Nikpour, B., Armanfard, N., Sagan, S. M., & Jahanshahi-Anbuhi, S. (2021) · Clinical Microbiology Reviews · doi:10.1128/cmr.00228-20 · Cited by 405
Paper-based microfluidics: Simplified fabrication and assay methods
Nishat, S., Jafry, A. T., Martinez, A. W., & Awan, F. R. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.129681 · Cited by 392
Metadata
- Authors
- Koczula, K. M., & Gallotta, A.
- Venue
- Essays in Biochemistry
- Publisher
- Portland Press Ltd.
- Published
- 2016-06-30
- Volume
- 60
- Issue
- 1
- Pages
- 111-120
- ISSN
- 0071-1365 (ISSN-L)
- 1744-1358
- OpenAlex
- W3103240054
- Cited by
- 1,147
- References
- 33
- FWCI
- 19.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.