High-Resolution Cervical Auscultation and Data Science: New Tools to Address an Old Problem
Open accessThe DOI matches its Crossref record; 40 of the 41 references it cites were found in a registry or an index.
Abstract
High-resolution cervical auscultation (HRCA) is an evolving clinical method for noninvasive screening of dysphagia that relies on data science, machine learning, and wearable sensors to investigate the characteristics of disordered swallowing function in people with dysphagia. HRCA has shown promising results in categorizing normal and disordered swallowing (i.e., screening) independent of human input, identifying a variety of swallowing physiological events as accurately as trained human judges. The system has been developed through a collaboration of data scientists, computer–electrical engineers, and speech-language pathologists. Its potential to automate dysphagia screening and contribute to evaluation lies in its noninvasive nature (wearable electronic sensors) and its growing ability to accurately replicate human judgments of swallowing data typically formed on the basis of videofluoroscopic imaging data. Potential contributions of HRCA when videofluoroscopic swallowing study may be unavailable, undesired, or not feasible for many patients in various settings are discussed, along with the development and capabilities of HRCA. The use of technological advances and wearable devices can extend the dysphagia clinician's reach and reinforce top-of-license practice for patients with swallowing disorders.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Videofluoroscopy of swallowing was used as the reference examination in most studies.”
From Artificial intelligence in the diagnosis and management of dysphagia: a scoping review (2025) · cites this paper as [26]
In the citing paper
“Studies on AI in dysphagia primarily rely on imaging resources such as VFSS for comparative analysis due to its high reliability(16,23-28).”
From Artificial intelligence in the diagnosis and management of dysphagia: a scoping review (2025) · cites this paper as [26]
Citations
Cites
Discrete-time Signal Processing
Williamson, D. (1999) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0541-1 · Cited by 4,858
A penetration-aspiration scale
Rosenbek, J. C., Robbins, J. A., Roecker, E. B., Coyle, J. L., & Wood, J. L. (1996) · Dysphagia · doi:10.1007/bf00417897 · Cited by 2,803 · cited 1×
“Events and scores from images that have been coded include categorical measurements (e.g., scores on the penetration aspiration scale [Rosenbek et al., 1996] and measurements of vallecular and pyriform sinus residue using the normalized residue ratio scale [Pearson et al., 2013]).”
MethodSelf-citationGraps, A. (1995) · IEEE Computational Science and Engineering · doi:10.1109/99.388960 · Cited by 1,765 · cited 1×
“Most efficient denoising algorithms are based on wavelets, which are state-of-the-art mathematical functions that divide the signal data into components based on their frequency range to enable each component to be analyzed using a scale that is matched to its resolution (Graps, 1995).”
BackgroundMBS Measurement Tool for Swallow Impairment—MBSImp: Establishing a Standard
Martin-Harris, B., Brodsky, M. B., Michel, Y., Castell, D. O., Schleicher, M., Sandidge, J., Maxwell, R., & Blair, J. (2008) · Dysphagia · doi:10.1007/s00455-008-9185-9 · Cited by 685 · cited 1×
“…between HRCA signals and component scores of various swallow kinematic events from the Modified Barium Swallow Impairment Profile (MBSImP; Martin-Harris et al., 2008) and found strong associations between HRCA signals and anterior hyoid bone movement (Component 9), pharyngoesophageal…”
BackgroundImage-based Measurement of Post-Swallow Residue: The Normalized Residue Ratio Scale
Pearson, W. G., Molfenter, S. M., Smith, Z. M., & Steele, C. M. (2013) · Dysphagia · doi:10.1007/s00455-012-9426-9 · Cited by 174 · cited 1×
“Events and scores from images that have been coded include categorical measurements (e.g., scores on the penetration aspiration scale [Rosenbek et al., 1996] and measurements of vallecular and pyriform sinus residue using the normalized residue ratio scale [Pearson et al., 2013]).”
MethodUsing cervical auscultation in the clinical dysphagia examination in long-term care
Zenner, P. M., Losinski, D. S., & Mills, R. H. (1995) · Dysphagia · doi:10.1007/bf00261276 · Cited by 170 · cited 2×
“Several studies have reported data indicating that specific “sounds” occurring during swallowing represent discrete physiological and kinematic events and that these observations may be useful surrogates for videofluoroscopic imaging studies (Borr et al., 2007; Leslie et al., 2007; Zenner et al., 1995).”
BackgroundReliability and Validity of Cervical Auscultation
Borr, C., Hielscher‐Fastabend, M., & Lücking, A. (2007) · Dysphagia · doi:10.1007/s00455-007-9078-3 · Cited by 138 · cited 3×
“These events were observed with concurrent imaging, including opening and closing of laryngo-pharyngeal valves, ventilatory sounds, and bolus flow (Borr et al., 2007).”
BackgroundMethodTest-retest variability in normal swallowing
Lof, G. L., & Robbins, J. (1990) · Dysphagia · doi:10.1007/bf02407271 · Cited by 133 · cited 2×
“Temporal and spatial event measurements were performed based on the methods of others (Lof & Robbins, 1990) to ensure compatibility of measures with historical, published data.”
BackgroundMethodBonilha, H. S., Blair, J., Carnes, B., Huda, W., Humphries, K., McGrattan, K., Michel, Y., & Martin-Harris, B. (2013) · Dysphagia · doi:10.1007/s00455-013-9463-z · Cited by 108 · cited 1×
“Fluoroscopy was performed at a pulse rate of 30 PPS, and images were accrued to a frame grabber card at 60 FPS and later down-sampled to 30 FPS to eliminate duplicate frames (Bonilha et al., 2013; Oppenheim & Schafer, 2014).”
MethodA Survey of Australian Dysphagia Practice Patterns
Rumbach, A. F., Coombes, C., & Doeltgen, S. (2017) · Dysphagia · doi:10.1007/s00455-017-9849-4 · Cited by 104 · cited 1×
“Up to one fourth of dysphagia clinicians use CA in diagnostic and management activities (Bateman et al., 2007; Rumbach et al., 2018; Vogels et al., 2015).”
BackgroundThe Physiologic Cause of Swallowing Sounds: Answers from Heart Sounds and Vocal Tract Acoustics
Cichero, J. A. Y., & Murdoch, B. E. (1998) · Dysphagia · doi:10.1007/pl00009548 · Cited by 87 · cited 1×
“Support for CA was first described more than 20 years ago by Cichero and Murdoch (1998), in a theoretical article in which a cardiac analogy theory was proposed.”
BackgroundDudik, J. M., Coyle, J. L., & Sejdic, E. (2015) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2015.2408615 · Cited by 86 · cited 5×
“HRCA was described by Dudik, Coyle, and Sejdi ć (2015) following 3 years of research that deployed a tri-axial accelerometer and high-resolution microphone to accrue the signals.”
BackgroundMethodInfluentialSelf-citationCervical Auscultation Synchronized with Images from Endoscopy Swallow Evaluations
Leslie, P., Drinnan, M. J., Zammit-Maempel, I., Coyle, J. L., Ford, G. A., & Wilson, J. A. (2007) · Dysphagia · doi:10.1007/s00455-007-9084-5 · Cited by 85 · cited 2×
“Leslie et al. (2007) investigated CA by using an electronic microphone to standardize data acquisition during concurrent imaging studies of swallowing.”
BackgroundMethodSelf-citationDudik, J. M., Kurosu, A., Coyle, J. L., & Sejdić, E. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.01.007 · Cited by 76 · cited 1×
“…swallows (scores of 3 – 8), as determined by the penetration – aspiration scale, with a high degree of accuracy (Dudik, Kurosu, et al., 2018; Dudik, Coyle, & Sejdi ć , 2015; Dudik et al., 2015; Dudik, Kurosu, et al., 2015; Jestrovi ć et al., 2013; Movahedi et al., 2017a; Sejdi ć et al., 2013).”
Self-citationAdult Dysphagia Assessment in the UK and Ireland: Are SLTs Assessing the Same Factors?
Bateman, C., Leslie, P., & Drinnan, M. J. (2007) · Dysphagia · doi:10.1007/s00455-006-9070-3 · Cited by 73 · cited 1×
“Up to one fourth of dysphagia clinicians use CA in diagnostic and management activities (Bateman et al., 2007; Rumbach et al., 2018; Vogels et al., 2015).”
BackgroundSejdic, E., Steele, C. M., & Chau, T. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2010504 · Cited by 73 · cited 1×
“A number of different algorithms have been proposed over the years to segment swallowing signals into individual swallows (Damouras et al., 2010; Dudik, Jestrovi ć , et al., 2015; Sejdi ć et al., 2009).”
BackgroundA comparative analysis of swallowing accelerometry and sounds during saliva swallows
Dudik, J. M., Jestrović, I., Luan, B., Coyle, J. L., & Sejdić, E. (2015) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-14-3 · Cited by 72 · cited 2×
“A number of different algorithms have been proposed over the years to segment swallowing signals into individual swallows (Damouras et al., 2010; Dudik, Jestrovi ć , et al., 2015; Sejdi ć et al., 2009).”
BackgroundMethodSelf-citationTiming Differences Between Cued and Noncued Swallows in Healthy Young Adults
Nagy, A., Leigh, C., Hori, S. F., Molfenter, S. M., Shariff, T., & Steele, C. M. (2013) · Dysphagia · doi:10.1007/s00455-013-9456-y · Cited by 64 · cited 1×
“These bolus size conditions were included in order to capture swallowing under both controlled and natural swallowing conditions, which have been shown to produce different temporal activity during swallowing (Nagy et al., 2013).”
MethodAutomatic hyoid bone detection in fluoroscopic images using deep learning
Zhang, Z., Coyle, J. L., & Sejdić, E. (2018) · Scientific Reports · doi:10.1038/s41598-018-30182-6 · Cited by 64 · cited 2×
“Zhang et al. (2018) recently sought to determine whether machine learning techniques could be used as a surrogate to manual spatial analysis to detect structural features of VFSS data from the video images themselves, demonstrating that unsupervised (i.e., without human input) advanced machine…”
BackgroundSelf-citationDysphagia and its effects on swallowing sounds and vibrations in adults
Dudik, J. M., Kurosu, A., Coyle, J. L., & Sejdić, E. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0501-9 · Cited by 58
Self-citationBaseline Characteristics of Dual-Axis Cervical Accelerometry Signals
Sejdić, E., Komisar, V., Steele, C. M., & Chau, T. T. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9874-z · Cited by 48 · cited 1×
“The first task in the signal processing method is to remove any confounding effects of the data acquisition system via a process called “whitening” (Sejdić et al., 2010).”
MethodSelf-citationNeck sensor-supported hyoid bone movement tracking during swallowing
Mao, S., Zhang, Z., Khalifa, Y., Donohue, C., Coyle, J. L., & Sejdic, E. (2019) · Royal Society Open Science · doi:10.1098/rsos.181982 · Cited by 47 · cited 1×
“…recently demonstrated that a combination of machine learning techniques, using noninvasive HRCA acceleration signals, can track the movement of the hyoid bone solely from the HRCA signals with a similar accuracy as trained human judges performing measurements using VFSS images (Mao et al., 2019).”
MethodSelf-citationAn Online Swallow Detection Algorithm Based on the Quadratic Variation of Dual-Axis Accelerometry
Damouras, S., Sejdic, E., Steele, C. M., & Chau, T. (2010) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2010.2043972 · Cited by 43 · cited 4×
“A number of different algorithms have been proposed over the years to segment swallowing signals into individual swallows (Damouras et al., 2010; Dudik, Jestrovi ć , et al., 2015; Sejdi ć et al., 2009).”
BackgroundMethodInfluentialSelf-citationSejdic, E., Malandraki, G. A., & Coyle, J. L. (2019) · IEEE Signal Processing Magazine · doi:10.1109/msp.2018.2875863 · Cited by 43 · cited 1×
“Hence, the first priority is to preprocess these swallowing signals and remove as much as possible the contaminating signal components (Sejdi ć et al., 2019).”
BackgroundSelf-citationA statistical analysis of cervical auscultation signals from adults with unsafe airway protection
Dudik, J. M., Kurosu, A., Coyle, J. L., & Sejdić, E. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0110-9 · Cited by 42 · cited 1×
“…signal features, and various dependent variables, such as penetration – aspiration scores, hyoid bone displacements in the anterior, posterior, superior, and inferior directions (Dudik et al., 2016; Dudik, Kurosu, et al., 2018; Kurosu et al., 2019; Movahedi et al., 2017b; Rebrion et al., 2019).”
BackgroundSelf-citationDeep learning for classification of normal swallows in adults
Dudik, J. M., Coyle, J. L., El-Jaroudi, A., Mao, Z.-H., Sun, M., & Sejdić, E. (2018) · Neurocomputing · doi:10.1016/j.neucom.2017.12.059 · Cited by 42
Self-citationSejdic, E., Steele, C. M., & Chau, T. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2243730 · Cited by 41 · cited 2×
“For example, machine learning algorithms have been successfully applied in classifying swallowing signals to identify and differentiate swallows exhibiting no aspiration and those with aspiration with a very high accuracy (Celeste et al., 2012; Sejdi ć et al., 2013).”
MethodSelf-citationA procedure for denoising dual-axis swallowing accelerometry signals
Sejdić, E., Steele, C. M., & Chau, T. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/n01 · Cited by 40 · cited 1×
“The first task in the signal processing method is to remove any confounding effects of the data acquisition sys-tem via a process called “ whitening ” (Sejdi ć et al., 2010).”
MethodSelf-citationTeaching cardiac auscultation to trainees in internal medicine and family practice: Does it work?
Favrat, B., Pécoud, A. R., & JAUSSI, A. (2004) · BMC Medical Education · doi:10.1186/1472-6920-4-5 · Cited by 39 · cited 1×
“To illustrate the challenges presented by auscultation with stethoscopes, Favrat et al. (2004) investigated the accuracy of cardiologists, internists, family practitioners, and residents in identifying cardiac sounds and generation of an accurate diagnosis based on chest auscultation.”
BackgroundHe, Q., Perera, S., Khalifa, Y., Zhang, Z., Mahoney, A. S., Sabry, A., Donohue, C., Coyle, J. L., & Sejdic, E. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2935302 · Cited by 39 · cited 1×
“We have also found a strong association between HRCA signal features and hyoid bone displacement (He et al., 2019; Rebrion et al., 2019; Zhang et al., 2018).”
BackgroundSelf-citationQuantitative classification of pediatric swallowing through accelerometry
Celeste, M., Azadeh, K., Sejdić, E., Berall, G., & Chau, T. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-34 · Cited by 37 · cited 1×
“For example, machine learning algorithms have been successfully applied in classifying swallowing signals to identify and differentiate swallows exhibiting no aspiration and those with aspiration with a very high accuracy (Celeste et al., 2012; Sejdi ć et al., 2013).”
Self-citationSound differences between electronic and acoustic stethoscopes
Nowak, Ł. J., & Nowak, K. M. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0540-2 · Cited by 34 · cited 2×
“…inability to collect and transmit the entire spectrum of acoustic and vibratory information emanating from the pharynx and larynx during swallowing (Nowak & Nowak, 2018), as well as the human auditory system ’ s limitations in perceiving and interpreting, in a standardized manner, the obtained…”
BackgroundThe bedside assessment practices of speech-language pathologists in adult dysphagia
Vogels, B., Cartwright, J., & Cocks, N. (2014) · International Journal of Speech-Language Pathology · doi:10.3109/17549507.2014.979877 · Cited by 33 · cited 1×
“Up to one fourth of dysphagia clinicians use CA in diagnostic and management activities (Bateman et al., 2007; Rumbach et al., 2018; Vogels et al., 2015).”
BackgroundKurosu, A., Coyle, J. L., Dudik, J. M., & Sejdic, E. (2019) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2018.05.038 · Cited by 33 · cited 2×
“Specific measurement methods for performing temporal measures of VFSS images have been described by Kurosu et al. (2019).”
BackgroundMethodSelf-citationAnatomical Directional Dissimilarities in Tri-axial Swallowing Accelerometry Signals
Movahedi, F., Kurosu, A., Coyle, J. L., Perera, S., & Sejdic, E. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2577882 · Cited by 32
Self-citationAnalysis of Hyoid–Larynx Complex Using 3D Geometric Morphometrics
Loth, A., Corny, J., Santini, L., Dahan, L. S., Dessi, P., Adalian, P., & Fakhry, N. (2015) · Dysphagia · doi:10.1007/s00455-015-9609-2 · Cited by 28 · cited 1×
“The height of the human hyoid body ranges from 0.6 to 1.2 cm (across male and female adults; Loth et al., 2015).”
BackgroundInfluentialA comparison between swallowing sounds and vibrations in patients with dysphagia
Movahedi, F., Kurosu, A., Coyle, J. L., Perera, S., & Sejdić, E. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.03.009 · Cited by 28 · cited 2×
“…signal features, and various dependent variables, such as penetration – aspiration scores, hyoid bone displacements in the anterior, posterior, superior, and inferior directions (Dudik et al., 2016; Dudik, Kurosu, et al., 2018; Kurosu et al., 2019; Movahedi et al., 2017b; Rebrion et al., 2019).”
BackgroundMethodSelf-citationDonohue, C., Khalifa, Y., Perera, S., Sejdić, E., & Coyle, J. L. (2021) · Dysphagia · doi:10.1007/s00455-020-10191-2 · Cited by 23
Self-citationBaseline characteristics of cervical auscultation signals during various head maneuvers
Jestrović, I., Dudik, J. M., Luan, B., Coyle, J. L., & Sejdić, E. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.10.005 · Cited by 13
Self-citationRebrion, C. (2017) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 2
Research works printed but not linked: 1
- Donohue C., 2018, Do machine ratings of hyoid bone displacement during videofluoroscopy match clinician ratings using the MBSImP? [Symposium]
Cited by
Donohue, C., Khalifa, Y., Perera, S., Sejdić, E., & Coyle, J. L. (2021) · Dysphagia · doi:10.1007/s00455-020-10191-2 · Cited by 23
Self-citationCordella, C., Marte, M. J., Liu, H., & Kiran, S. (2024) · Perspectives of the ASHA Special Interest Groups · doi:10.1044/2024_persp-24-00037 · Cited by 32
“These approaches include wearable sensors (Cao et al., 2023; Coyle & Sejdić, 2020; Van Stan et al., 2015), smartphone digital recordings (Connaghan et al., 2019; Kadambi et al., 2023; Van Stan et al., 2017), and ecological momentary assessment (Hester et al., 2023; Marks et al., 2021) to name a few.”
Frakking, T. T., Chang, A. B., Carty, C., Newing, J., Weir, K. A., Schwerin, B., & So, S. (2022) · Dysphagia · doi:10.1007/s00455-022-10410-y · Cited by 23
“vasomotion of major arteries, head movement) [29].”
Bandini, A., Smaoui, S., & Steele, C. M. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107058 · Cited by 16
“Most of these approaches involve the use of computer vision - for example, to analyze VFSS recordings [12]–[16], [18], [20]–[22] - or signal processing techniques to extract and analyze acoustic, accelerometric, and/or electromyographic signals [23]–[29].”
BackgroundShu, K., Mao, S., Zhang, Z., Coyle, J. L., & Sejdić, E. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108505 · Cited by 16
Self-citation
Metadata
- Authors
- Coyle, J. L., & Sejdić, E.
- Affiliations
- University of Pittsburgh (US)
- Venue
- American Journal of Speech-Language Pathology
- Published
- 2020-07-10
- Volume
- 29
- Issue
- 2S
- Pages
- 992-1000
- ISSN
- 1058-0360 (ISSN-L)
- 1558-9110
- PMC
- PMC7844341
- OpenAlex
- W3041246547
- Cited by
- 28
- References
- 41
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 4 · 2023: 4 · 2022: 4 · 2021: 2 · 2020: 2
- FWCI
- 4.27
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- American Journal of Speech-Language Pathology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD074819, R01HD092239)
- Topics
- Health Sciences › Health Professions › Speech and Hearing › Dysphagia Assessment and Management
- Health Sciences › Health Professions › Speech and Hearing › Voice and Speech Disorders
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Keywords
- dysphagia screening, dysphagia, wearable sensors, machine learning, videofluoroscopic swallowing study, swallowing physiology
- MeSH terms
- Data Science, Auscultation, Cineradiography, Deglutition, Deglutition Disorders, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.