Semen analysis performed by different laboratory teams: an intervariation study
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Some recent studies have indicated that sperm concentration has decreased during the last 50 years. However, comparisons between laboratories have revealed that geographical differences seem to exist and that any decrease may not be global. One point of criticism concerning comparison of results from different laboratories has been that some of the discrepancies detected could reflect the lack of standardized methods used in the different laboratories. Four teams, each consisting of one physician and one technician from groups which have recently published data on semen quality, met in order to evaluate the variability between their laboratories on semen analysis. Twenty‐six fresh semen samples from unselected men were analysed. The groups analysed the samples according to the normal practice in their laboratories, using their own equipment. The variation between laboratories was estimated through a random effects model. For sperm concentration and semen volume assessment a remarkable consistency between laboratories was detected, in contrast to the very considerable inter‐individual variation. For sperm motility and morphology assessments interlaboratory consistency was much poorer. In conclusion, evaluation of sperm motility and morphology characteristics requires further standardization in order to achieve comparable data from different laboratories. However, semen volume and sperm concentration are characteristics which can be compared reliably between laboratories, when similar methodologies are used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The evaluation of morphological characteristics of human spermatozoa according to stricter criteria
Menkveld, R., Stander, F. S. H., Kotze, T. J. V., Kruger, T. F., & Zyl, J. A. V. (1990) · Human Reproduction · doi:10.1093/oxfordjournals.humrep.a137150 · Cited by 677
Cited by
State-of-the-science of endocrine disrupting chemicals, 2012
Bergman, Å., Heindel, J., Jobling, S., Kidd, K., & Zoeller, R. T. (2012) · Toxicology Letters · doi:10.1016/j.toxlet.2012.03.020 · Cited by 1,388
Body mass index in relation to semen quality and reproductive hormonesamong 1,558 Danish men
Jensen, T. K., Andersson, A.-M., Jørgensen, N., Andersen, A.-G., Carlsen, E., Petersen, J. Ø. H., & Skakkebæk, N. E. (2004) · Fertility and Sterility · doi:10.1016/j.fertnstert.2004.03.056 · Cited by 818
Self-citationSperm DNA integrity assessment in prediction of assisted reproduction technology outcome
Bungum, M., Humaidan, P., Axmon, A., Spano, M., Bungum, L., Erenpreiss, J., & Giwercman, A. (2007) · Human Reproduction · doi:10.1093/humrep/del326 · Cited by 703
Self-citationRegional differences in semen quality in Europe
Jørgensen, N., Andersen, A.-G., Eustache, F., Irvine, D. S., Suominen, J., Petersen, J. H., Andersen, A. N., Auger, J., Cawood, E. H. H., Horte, A., et al. (2001) · Human Reproduction · doi:10.1093/humrep/16.5.1012 · Cited by 456
Self-citationThe ‘oestrogen hypothesis’– where do we stand now?1
Sharpe, R. M. (2003) · International Journal of Andrology · doi:10.1046/j.1365-2605.2003.00367.x · Cited by 330
High frequency of sub-optimal semen quality in an unselected population of young men
Andersen, A. G. (2000) · Human Reproduction · doi:10.1093/humrep/15.2.366 · Cited by 323
“In the lower panels of Figure 1, the concentrations ofA previous study found inter-observer variability in semen analysis inhibin B and FSH are stratified according to spermbetween different laboratories (Jørgensen et al., 1997), especially concerning motility assessments.”
BackgroundMethodJorgensen, N. (2002) · Human Reproduction · doi:10.1093/humrep/17.8.2199 · Cited by 319
Slama, R. (2002) · Human Reproduction · doi:10.1093/humrep/17.2.503 · Cited by 308
“A technician from each of the four laboratories took part in a standardization workshop in Copenhagen before the start of the study (Jørgensen et al., 1997).”
BackgroundMethodInfluentialJørgensen, N., Joensen, U. N., Jensen, T. K., Jensen, M. B., Almstrup, K., Olesen, I. A., Juul, A., Andersson, A.-M., Carlsen, E., Petersen, J. H., et al. (2012) · BMJ Open · doi:10.1136/bmjopen-2012-000990 · Cited by 290
Self-citationDamsgaard, J., Joensen, U. N., Carlsen, E., Erenpreiss, J., Blomberg Jensen, M., Matulevicius, V., Zilaitiene, B., Olesen, I. A., Perheentupa, A., Punab, M., et al. (2016) · European Urology · doi:10.1016/j.eururo.2016.06.044 · Cited by 284
Self-citationLewis, S. E. M., John Aitken, R., Conner, S. J., Iuliis, G. D., Evenson, D. P., Henkel, R., Giwercman, A., & Gharagozloo, P. (2013) · Reproductive BioMedicine Online · doi:10.1016/j.rbmo.2013.06.014 · Cited by 278
Self-citationHistory of febrile illness and variation in semen quality
Carlsen, E. (2003) · Human Reproduction · doi:10.1093/humrep/deg412 · Cited by 256
“mitotic proliferation, meiotic division, spermiogenesis (postmeiotic period) and epididymal sperm maturation, which occur approximately 57‐80, 33‐56, 9‐32 and 0‐8 days respectively prior to ejaculation of the sperm ( Heller and Clermont, 1964 ) (Figure 1). Consequently, we used these time-intervals for our calculation…”
MethodJensen, T. K. (2004) · American Journal of Epidemiology · doi:10.1093/aje/kwh002 · Cited by 246
“A previous study found interobserver variability in semen analysis between different laboratories (34), especially in motility assessment.”
BackgroundSelf-citationGundersen, T. D., Jørgensen, N., Andersson, A.-M., Bang, A. K., Nordkap, L., Skakkebæk, N. E., Priskorn, L., Juul, A., & Jensen, T. K. (2015) · American Journal of Epidemiology · doi:10.1093/aje/kwv135 · Cited by 225
Self-citationJensen, T. K., Heitmann, B. L., Jensen, M. B., Halldorsson, T. I., Andersson, A.-M., Skakkebæk, N. E., Joensen, U. N., Lauritsen, M. P., Christiansen, P., Dalgård, C., et al. (2013) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.112.042432 · Cited by 193
Self-citationAuger, J. (2000) · Human Reproduction · doi:10.1093/humrep/15.11.2360 · Cited by 191
“For planned multicentre studies, a prestudy EQA should be performed, followed by corrective measures a and b motile spermatozoa (Yeung et al., 1997), since assessment of such spermatozoa is a major source of variability if necessary, as in a recent study of geographical variation in semen quality in Europe (Jorgensen…”
BackgroundResultInfluentialSelf-citationRichthoff, J., Rylander, L., Jönsson, B. A. G., Akesson, H., Hagmar, L., Nilsson-Ehle, P., Stridsberg, M., & Giwercman, A. (2003) · Environmental Health Perspectives · doi:10.1289/ehp.5767 · Cited by 173
“CASA analysis of sperm motility is subject to a lesser degree of intralaboratory variation than is the manual analysis (Auger et al. 2000; Boone et al. 2000; Jørgensen et al. 1997) and may therefore be a more sensitive measure of male fertility.”
Self-citationRecent adverse trends in semen quality and testis cancer incidence among Finnish men
Jørgensen, N., Vierula, M., Jacobsen, R., Pukkala, E., Perheentupa, A., Virtanen, H. E., Skakkebæk, N. E., & Toppari, J. (2011) · International Journal of Andrology · doi:10.1111/j.1365-2605.2010.01133.x · Cited by 164
“However, the distinction between motile and immotile spermatozoa may be more reliable than distinction between different subcategories of motilities (Jørgensen et al., 1997), which is the reason why we have only presented the frequencies of motile spermatozoa.”
BackgroundSelf-citationRavnborg, T. L., Jensen, T. K., Andersson, A.-M., Toppari, J., Skakkebaek, N. E., & Jorgensen, N. (2011) · Human Reproduction · doi:10.1093/humrep/der011 · Cited by 96
“Details of the methods have previously been described (Jørgensen et al., 1997, 2002).”
BackgroundMethodSelf-citationFilimberti, E., Degl'Innocenti, S., Borsotti, M., Quercioli, M., Piomboni, P., Natali, I., Fino, M. G., Caglieresi, C., Criscuoli, L., Gandini, L., et al. (2013) · Andrology · doi:10.1111/j.2047-2927.2012.00042.x · Cited by 68
“For these reasons, the necessity of external quality control (EQC) and standardization of the procedures has been highlighted in several studies (Neuwinger et al., 1990; Jørgensen et al., 1997; Gandini et al., 2000; Cooper et al., 2002; Keel et al., 2002; Palacios et al., 2012), and the last two editions of the WHO ma…”
MethodResultInfluentialFifteen years of Belgian experience with external quality assessment of semen analysis
Punjabi, U., Wyns, C., Mahmoud, A., Vernelen, K., China, B., & Verheyen, G. (2016) · Andrology · doi:10.1111/andr.12230 · Cited by 64
“…for the determination of sperm concentration, motility, and morphology is being widely appreciated in Europe (Neuwinger et al., 1990; Cooper, 1996; Jørgensen et al., 1997; Ochsendorf & Beschmann, 1998; Auger et al., 2000; Alvarez et al., 2005; Mallidis et al., 2012; Jedrzejczak et al., 2012; 1084…”
BackgroundReassessment of sperm morphology of archival semen smears from the period 1980–1994
Horte, A., Vierula, M., Toppari, J., & Suominen, J. (2001) · International Journal of Andrology · doi:10.1046/j.1365-2605.2001.00285.x · Cited by 14
Self-citation
Metadata
- Authors
- JØRGENSEN, N., AUGER, J., GIWERCMAN, A., IRVINE, D. S., JENSEN, T. K., JOUANNET, P., KEIDING, N., BON, C. L., MACDONALD, E., PEKURI, A. ‐., SCHEIKE, T., SIMONSEN, M., SUOMINEN, J., & SKAKKEBŒK, N. E.
- Venue
- International Journal of Andrology
- Publisher
- Wiley
- Published
- 1997-08
- Volume
- 20
- Issue
- 4
- Pages
- 201-208
- ISSN
- 0105-6263 (ISSN-L)
- 1365-2605
- OpenAlex
- W2011851015
- Cited by
- 176
- References
- 1
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.