CoChat

Long‐Term Complication Rates in Ventricular, Single Lead VDD, and Dual Chamber Pacing

WIEGAND, UWE K.H., BODE, FRANK, BONNEMEIER, HENDRIK, EBERHARD, FRANK, SCHLEI, MONIKA, PETERS, WERNER · 2003 · Pacing and Clinical Electrophysiology
Cited by 106

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

A higher incidence of pacemaker related complications has been reported in DDD systems as compared to VVI devices. The implantation of single lead VDD pacemakers might reduce the complication rate of physiological pacing in patients with AV block. In a retrospective study, the data records of 1,214 consecutive patients with pacemaker implantation for AV block between 1990 and 2001 (VVI 36.5%, DDD 32.9%, VDD 30.6%) were analyzed. Complications requiring surgical interventions were compared during a follow‐up period of 64 ± 31 months. Operation and fluoroscopic times were longer in DDD pacemaker implantation compared to VDD and VVI devices: 58 ± 23 versus 39 ± 10 and 37 ± 13 minutes (P < 0.001), 9.2 ± 5.2 versus 4.1 ± 2.4 and 3.5 ± 2.3 minutes , respectively. Differences remained significant after correction for covariates. In a multivariate Cox regression model, the corrected complication hazard of a DDD pacemaker implantation was increased by 3.9 (1.4–11.3) compared to VVI and increased by 2.3 (1.1–4.5) compared to VDD pacing. Higher complication rates in DDD pacing were mainly due to a higher incidence of early reoperation for atrial lead dysfunction, whereas the long‐term complication rate was not different from VDD or VVI pacing. Early and long‐term complication rates did not differ between VDD and VVI pacemaker systems. In conclusion, operation time and complication rates of physiological pacing are reduced by VDD pacemaker implantation achieving values comparable to VVI pacing. Thus, single lead VDD pacing can be recommended for patients with AV block. (PACE 2003; 26:1961–1969)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1460-9592.2003.00303.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 106

Metadata

Authors
WIEGAND, U. K. H., BODE, F., BONNEMEIER, H., EBERHARD, F., SCHLEI, M., & PETERS, W.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2003-10
Volume
26
Issue
10
Pages
1961-1969
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2043900744
Cited by
106
References
2
FWCI
2.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long‐Term Complication Rates in Ventricular, Single Lead VDD, and Dual Chamber Pacing. https://app.cochat.ai/papers/10.1046/j.1460-9592.2003.00303.x
The paper
WIEGAND, U. K. H., BODE, F., BONNEMEIER, H., EBERHARD, F., SCHLEI, M., & PETERS, W. (2003). Long‐Term Complication Rates in Ventricular, Single Lead VDD, and Dual Chamber Pacing. Pacing and Clinical Electrophysiology. https://doi.org/10.1046/j.1460-9592.2003.00303.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.