Effectiveness of screening and monitoring tests for diabetic retinopathy – a systematic review
The DOI matches its Crossref record.
Abstract
SUMMARY Aims To determine which screening and monitoring tests for diabetic retinopathy are most effective and under what circumstances. Methods A systematic review of the English language literature, published from 1983 to April 1999. Results Available studies are generally limited in their ability to answer the important questions on the effectiveness of tests for early detection of diabetic retinopathy. No randomized controlled trials were identified although primary studies exist for two screening tests: ophthalmoscopy, either direct or indirect, and retinal photography, using either mydriasis or non‐mydriasis. Retinal photography under mydriasis appears to be the most effective test, with the majority reporting levels of sensitivity in excess of 80%. However effectiveness is compromised when photographs are ungradable. Ophthalmoscopy can also reach acceptable standards of sensitivity and specificity. Conclusion Based on an assessment of available cohort studies, the most effective strategy for testing is the use of mydriatic retinal photography with the additional use of ophthalmoscopy for cases where photographs are ungradable. This does not exclude the use of ophthalmoscopy alone for opportunistic case finding but there is evidence of considerable variation in effectiveness of this test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Artificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554
Artificial Intelligence and Deep Learning in Ophthalmology
Wang, Z., Keane, P. A., Chiang, M., Cheung, C. Y., Wong, T. Y., & Ting, D. S. W. (2022) · Artificial Intelligence in Medicine · doi:10.1007/978-3-030-64573-1_200 · Cited by 1,524
Ting, D. S. W., Cheung, G. C. M., & Wong, T. Y. (2016) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.12696 · Cited by 1,066
Diabetic Retinopathy and Diabetic Macular Edema
Ciulla, T. A., Amador, A. G., & Zinman, B. (2003) · Diabetes Care · doi:10.2337/diacare.26.9.2653 · Cited by 836
Guidelines for improving the care of the older person with diabetes mellitus
California Healthcare Foundation/American Geriatrics Society, C. (2003) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.51.5s.1.x · Cited by 651
Fong, D. S., Aiello, L. P., Ferris, F. L., & Klein, R. (2004) · Diabetes Care · doi:10.2337/diacare.27.10.2540 · Cited by 640
van der Heijden, A. A., Abramoff, M. D., Verbraak, F., van Hecke, M. V., Liem, A., & Nijpels, G. (2018) · Acta Ophthalmologica · doi:10.1111/aos.13613 · Cited by 296
“Sensitivities of the experts calculated against a reference standard which includes each of them (thus giving a slight advantage compared to an expert that would not have been part of the gold standard) showed that these ranged between 59% and 93% for EURODIAB and 58–100% for ICDR, which is in line with other studies…”
ResultSingle-field fundus photography for diabetic retinopathy screening
Williams, G. A., Scott, I. U., Haller, J. A., Maguire, A. M., Marcus, D., & McDonald, H. R. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.02.004 · Cited by 266
Ullah, A., Anwar, S. M., Li, J., Nadeem, L., Mahmood, T., Rehman, A., & Saba, T. (2024) · Complex & Intelligent Systems · doi:10.1007/s40747-023-01175-4 · Cited by 263
Deep Learning Fundus Image Analysis for Diabetic Retinopathy and Macular Edema Grading
Sahlsten, J., Jaskari, J., Kivinen, J., Turunen, L., Jaanio, E., Hietala, K., & Kaski, K. (2019) · Scientific Reports · doi:10.1038/s41598-019-47181-w · Cited by 252
Cortisol Secretion in Patients With Type 2 Diabetes
Chiodini, I., Adda, G., Scillitani, A., Coletti, F., Morelli, V., Di Lembo, S., Epaminonda, P., Masserini, B., Beck-Peccoz, P., Orsi, E., et al. (2007) · Diabetes Care · doi:10.2337/dc06-1267 · Cited by 244
“Background retinopathy was ascertained by fundus oculi examination (31).”
Retinal Imaging Techniques for Diabetic Retinopathy Screening
Goh, J. K. H., Cheung, C. Y., Sim, S. S., Tan, P. C., Tan, G. S. W., & Wong, T. Y. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816629491 · Cited by 174
Validation of Smartphone Based Retinal Photography for Diabetic Retinopathy Screening
Rajalakshmi, R., Arulmalar, S., Usha, M., Prathiba, V., Kareemuddin, K. S., Anjana, R. M., & Mohan, V. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138285 · Cited by 173
“Many studies have suggested that retinal photography after dilatation is equivalent or superior to ophthalmoscopic examination for detection of DR [9,10].”
BackgroundVerbraak, F. D., Abramoff, M. D., Bausch, G. C. F., Klaver, C., Nijpels, G., Schlingemann, R. O., & van der Heijden, A. A. (2019) · Diabetes Care · doi:10.2337/dc18-0148 · Cited by 115
“A relatively low sensitivity to detect DR in a standard of care setting, using single human graders, has been shown in previous studies (11,35,36).”
MethodDiabetic retinopathy management guidelines
Chakrabarti, R., Harper, C. A., & Keeffe, J. E. (2012) · Expert Review of Ophthalmology · doi:10.1586/eop.12.52 · Cited by 112
Screening for Diabetic Retinopathy
Squirrell, D. M., & Talbot, J. F. (2003) · Journal of the Royal Society of Medicine · doi:10.1177/014107680309600604 · Cited by 51
Elsharkawy, M., Elrazzaz, M., Sharafeldeen, A., Alhalabi, M., Khalifa, F., Soliman, A., Elnakib, A., Mahmoud, A., Ghazal, M., El-Daydamony, E., et al. (2022) · Sensors · doi:10.3390/s22093490 · Cited by 38
“Therefore, using SSFs color photography is generally considered more sensitive [56,57].”
MethodBegum, T., Rahman, A., Nomani, D., Mamun, A., Adams, A., Islam, S., Khair, Z., Khair, Z., & Anwar, I. (2021) · JMIR Public Health and Surveillance · doi:10.2196/23538 · Cited by 24
Interventions to increase attendance for diabetic retinopathy screening
Lawrenson, J. G., Graham-Rowe, E., Lorencatto, F., Presseau, J., Burr, J., Ivers, N., Quartilho, A., Bunce, C., Francis, J. J., Grimshaw, J. M., et al. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012054 · Cited by 10
Metadata
- Authors
- Hutchinson, A., McIntosh, A., Peters, J., O'keeffe, C., Khunti, K., Baker, R., & Booth, A.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2000-07
- Volume
- 17
- Issue
- 7
- Pages
- 495-506
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W2051013472
- Cited by
- 248
- References
- 0
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.