CoChat

Performance assessment of the Medtronic‐MiniMed Continuous Glucose Monitoring System and its use for measurement of glycaemic control in Type 1 diabetic subjects

Sachedina, N., Pickup, J. C. · 2003 · Diabetic Medicine
Cited by 143

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Aims To assess the accuracy, reliability and measurement of glycaemic control associated with the Medtronic‐MiniMed Continuous Glucose Monitoring System (CGMS) in comparison with blood glucose self‐monitoring (BGSM) in Type 1 diabetic patients. Methods Type 1 diabetic patients (n = 18) underwent glucose monitoring by the CGMS for up to 3 days, when control was also assessed by BGSM performed eight times daily. Results Ninety‐five per cent of paired non calibration samples were in the clinically acceptable zones of the Clarke error grid, and 97% in a consensus grid. The median bias was 0.1 mmol/l and relative bias 15%. The failure rate of sensors was 28% of those initially inserted. The CGMS detected significantly more hypoglycaemia and post‐prandial hyperglycaemia, but total duration of hyperglycaemia, blood glucose oscillations and day‐to‐day variability were similarly assessed by CGMS and BGSM. Conclusions The CGMS has acceptable clinical accuracy. Detection by the CGMS of more hypoglycaemia and post‐prandial hyperglycaemia than BGSM promises a valuable tool for control assessment and optimization of treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1464-5491.2003.01037.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 143

Metadata

Authors
Sachedina, N., & Pickup, J. C.
Venue
Diabetic Medicine
Publisher
Wiley
Published
2003-11-24
Volume
20
Issue
12
Pages
1012-1015
ISSN
  • 0742-3071 (ISSN-L)
  • 1464-5491
OpenAlex
W1982137772
Cited by
143
References
4
FWCI
6.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.