Performance assessment of the Medtronic‐MiniMed Continuous Glucose Monitoring System and its use for measurement of glycaemic control in Type 1 diabetic subjects
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Aims To assess the accuracy, reliability and measurement of glycaemic control associated with the Medtronic‐MiniMed Continuous Glucose Monitoring System (CGMS) in comparison with blood glucose self‐monitoring (BGSM) in Type 1 diabetic patients. Methods Type 1 diabetic patients (n = 18) underwent glucose monitoring by the CGMS for up to 3 days, when control was also assessed by BGSM performed eight times daily. Results Ninety‐five per cent of paired non calibration samples were in the clinically acceptable zones of the Clarke error grid, and 97% in a consensus grid. The median bias was 0.1 mmol/l and relative bias 15%. The failure rate of sensors was 28% of those initially inserted. The CGMS detected significantly more hypoglycaemia and post‐prandial hyperglycaemia, but total duration of hyperglycaemia, blood glucose oscillations and day‐to‐day variability were similarly assessed by CGMS and BGSM. Conclusions The CGMS has acceptable clinical accuracy. Detection by the CGMS of more hypoglycaemia and post‐prandial hyperglycaemia than BGSM promises a valuable tool for control assessment and optimization of treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Parkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
Evans, J. M. M., Newton, R. W., Ruta, D. A., MacDonald, T. M., Stevenson, R. J., & Morris, A. D. (1999) · BMJ · doi:10.1136/bmj.319.7202.83 · Cited by 283
Bode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232
A Pilot Study of the Continuous Glucose Monitoring System
Kaufman, F. R., Gibson, L. C., Halvorson, M., Carpenter, S., Fisher, L. K., & Pitukcheewanont, P. (2001) · Diabetes Care · doi:10.2337/diacare.24.12.2030 · Cited by 224
Cited by
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Self-citationGlucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Nonenzymatic Electrochemical Glucose Sensor Based on Nanoporous PtPb Networks
Wang, J., Thomas, D. F., & Chen, A. (2008) · Analytical Chemistry · doi:10.1021/ac701790z · Cited by 534
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
Murphy, H. R., Rayman, G., Lewis, K., Kelly, S., Johal, B., Duffield, K., Fowler, D., Campbell, P. J., & Temple, R. C. (2008) · BMJ · doi:10.1136/bmj.a1680 · Cited by 358
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Mayer, M., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00719 · Cited by 300
Gill, G. V., Woodward, A., Casson, I. F., & Weston, P. J. (2009) · Diabetologia · doi:10.1007/s00125-008-1177-7 · Cited by 294
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Fokkert, M. J., van Dijk, P. R., Edens, M. A., Abbes, S., de Jong, D., Slingerland, R. J., & Bilo, H. J. G. (2017) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2016-000320 · Cited by 209
Continuous monitoring of circadian glycemic patterns in patients receiving prednisolone for COPD
Burt, M. G., Roberts, G. W., Aguilar-Loza, N. R., Frith, P., & Stranks, S. N. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2729 · Cited by 203
In vivo glucose monitoring: the clinical reality and the promise
Pickup, J. C., Hussain, F., Evans, N. D., & Sachedina, N. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.08.016 · Cited by 203
Self-citationChanges in the glycemic profiles of women with type 1 and type 2 diabetes during pregnancy
Murphy, H. R., Rayman, G., Duffield, K., Lewis, K. S., Kelly, S., Johal, B., Fowler, D., & Temple, R. C. (2007) · Diabetes Care · doi:10.2337/dc07-0500 · Cited by 138
Freckmann, G., Eichenlaub, M., Waldenmaier, D., Pleus, S., Wehrstedt, S., Haug, C., Witthauer, L., Jendle, J., Hinzmann, R., Thomas, A., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231190941 · Cited by 86
Chetty, V. T., Almulla, A., Odueyungbo, A., & Thabane, L. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.02.014 · Cited by 85
“correlation between interstitial glucose and plasma glucose [10].”
BackgroundInfluentialValidation of the continuous glucose monitoring sensor in preterm infants
Beardsall, K., Vanhaesebrouck, S., Ogilvy-Stuart, A. L., Vanhole, C., vanWeissenbruch, M., Midgley, P., Thio, M., Cornette, L., Ossuetta, I., Palmer, C. R., et al. (2013) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/archdischild-2012-301661 · Cited by 82
Evolution of Devices in Diabetes Management
Penfornis, A., Personeni, E., & Borot, S. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0058 · Cited by 49
“…the CGMS detected significantly more incidences of hypoglycemia and postprandial hyperglycemia compared with standard blood glucose testing, the day-to-day variability was similar between the two groups, and, with a sensor failure rate of 28%, 52 the effectiveness of this method of CGM is debatable.”
Philippou, E., McGowan, B. M. C., Brynes, A. E., Dornhorst, A., Leeds, A. R., & Frost, G. S. (2008) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602688 · Cited by 34
“This has been previously validated (Sachedina and Pickup, 2003).”
Metadata
- Authors
- Sachedina, N., & Pickup, J. C.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2003-11-24
- Volume
- 20
- Issue
- 12
- Pages
- 1012-1015
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W1982137772
- Cited by
- 143
- References
- 6
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.