On-line monitoring of the MOSFET device junction temperature by computation of the threshold voltage
The DOI matches its Crossref record.
Abstract
A method for an on-line junction temperature measurement is introduced. The circuit allows the calibration of a real-time thermal model of a power MOSFET. A regular calibration of the real-time model provides an accurate thermal flux model over the lifetime of the power MOSFET. The measurement of threshold voltage is used to determine the device temperature. The paper presents the on-line measurement method, the circuit and test results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Avenas, Y., Dupont, L., & Khatir, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2178433 · Cited by 559
Investigation Into IGBT dV/dt During Turn-Off and Its Temperature Dependence
Bryant, A., Yang, S., Mawby, P., Xiang, D., Ran, L., Tavner, P., & Palmer, P. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2125803 · Cited by 235
Improved Reliability of Power Modules: A Review of Online Junction Temperature Measurement Methods
Baker, N., Liserre, M., Dupont, L., & Avenas, Y. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2014.2312427 · Cited by 232
“High (each switching cycle) Good linearity Nanosecond or picoseconds per C [48]–[50]”
BackgroundMonitoring Solder Fatigue in a Power Module Using Case-Above-Ambient Temperature Rise
Xiang, D., Ran, L., Tavner, P., Bryant, A., Yang, S., & Mawby, P. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168556 · Cited by 193
Power electronics - the key technology for renewable energy system integration
Blaabjerg, F., Yang, Y., Ma, K., & Wang, X. (2015) · 2015 International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera.2015.7418680 · Cited by 148
Evaluation of Aging's Effect on Temperature-Sensitive Electrical Parameters in SiC mosfets
Yang, F., Ugur, E., & Akin, B. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2950311 · Cited by 121
“The turn-ON delay time is a TSEP [18], [19] and can be expressed as follows [69]:”
MethodReview of SiC MOSFET based three-phase inverter lifetime prediction
Ni, Z., Lyu, X., Yadav, O. P., & Cao, D. (2017) · 2017 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2017.7930819 · Cited by 40
AC Power Cycling Test Setup and Condition Monitoring Tools for SiC-Based Traction Inverters
Farhadi, M., Vankayalapati, B. T., Sajadi, R., & Akin, B. (2023) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2023.3271251 · Cited by 24
Accurate Temperature Measurement of Active Area for Wide-Bandgap Power Semiconductors
Ramyar, A., Lou, Y., & Avestruz, A.-T. (2023) · 2023 IEEE 24th Workshop on Control and Modeling for Power Electronics (COMPEL) · doi:10.1109/compel52896.2023.10221096 · Cited by 1
“On-state resistance [9], [13], [14], threshold voltage [15], sub-threshold voltage [16], and drain current [17] are among the TSEPs used in the literature for temperature measurement of power semiconductors.”
Background
Metadata
- Authors
- Chen, H., Pickert, V., Atkinson, D. J., & Pritchard, L. S.
- Venue
- 3rd IET International Conference on Power Electronics, Machines and Drives (PEMD 2006)
- Publisher
- IEE
- Published
- 2006
- Volume
- 2006
- Pages
- 440-444
- OpenAlex
- W2160272210
- Cited by
- 60
- References
- 0
- FWCI
- 1.06
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.