Continuous non‐contact vital sign monitoring in neonatal intensive care unit
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Current technologies to allow continuous monitoring of vital signs in pre‐term infants in the hospital require adhesive electrodes or sensors to be in direct contact with the patient. These can cause stress, pain, and also damage the fragile skin of the infants. It has been established previously that the colour and volume changes in superficial blood vessels during the cardiac cycle can be measured using a digital video camera and ambient light, making it possible to obtain estimates of heart rate or breathing rate. Most of the papers in the literature on non‐contact vital sign monitoring report results on adult healthy human volunteers in controlled environments for short periods of time. The authors' current clinical study involves the continuous monitoring of pre‐term infants, for at least four consecutive days each, in the high‐dependency care area of the Neonatal Intensive Care Unit (NICU) at the John Radcliffe Hospital in Oxford. The authors have further developed their video‐based, non‐contact monitoring methods to obtain continuous estimates of heart rate, respiratory rate and oxygen saturation for infants nursed in incubators. In this Letter, it is shown that continuous estimates of these three parameters can be computed with an accuracy which is clinically useful. During stable sections with minimal infant motion, the mean absolute error between the camera‐derived estimates of heart rate and the reference value derived from the ECG is similar to the mean absolute error between the ECG‐derived value and the heart rate value from a pulse oximeter. Continuous non‐contact vital sign monitoring in the NICU using ambient light is feasible, and the authors have shown that clinically important events such as a bradycardia accompanied by a major desaturation can be identified with their algorithms for processing the video signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Eulerian video magnification for revealing subtle changes in the world
Wu, H.-Y., Rubinstein, M., Shih, E., Guttag, J., Durand, F., & Freeman, W. (2012) · ACM Transactions on Graphics · doi:10.1145/2185520.2185561 · Cited by 1,357 · cited 2×
“0077 C Freeman group at MIT [5] was used to amplify the colour variations in the Sony camera images and visualise the pulse.”
MethodInfluentialNon-contact video-based vital sign monitoring using ambient light and auto-regressive models
Tarassenko, L., Villarroel, M., Guazzi, A., Jorge, J., Clifton, D. A., & Pugh, C. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/5/807 · Cited by 423 · cited 2×
“Continuous non-contact vital sign monitoring in neonatal intensive care unit Mauricio Villarroel1, Alessandro Guazzi1, João Jorge1, Sara Davis2, Peter Watkinson3, Gabrielle Green2,”
BackgroundSelf-citationAarts, L. A. M., Jeanne, V., Cleary, J. P., Lieber, C., Nelson, J. S., Bambang Oetomo, S., & Verkruysse, W. (2013) · Early Human Development · doi:10.1016/j.earlhumdev.2013.09.016 · Cited by 241 · cited 1×
“A team of academic researchers working with Philips (Eindhoven, The Netherlands) have since made video camera recordings of 19 infants in two NICUs in California and the Netherlands [3].”
BackgroundNeonatal non-contact respiratory monitoring based on real-time infrared thermography
Abbas, A. K., Heimann, K., Jergus, K., Orlikowsky, T., & Leonhardt, S. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-93 · Cited by 227 · cited 1×
“[6] described methods to derive respiratory rate from an infrared thermal camera.”
MethodGodbehere, A. B., Matsukawa, A., & Goldberg, K. (2012) · 2012 American Control Conference (ACC) · doi:10.1109/acc.2012.6315174 · Cited by 189 · cited 2×
“Seven infants were monitored in this study, each for a maximum of 30 s with a webcam 20 cm away from the face and with special illumination.”
BackgroundMethodBenaron, D. A., Parachikov, I. H., Friedland, S., Soetikno, R., Brock-Utne, J., van der Starre, P. J. A., Nezhat, C., Terris, M. K., Maxim, P. G., Carson, J. J. L., et al. (2004) · Anesthesiology · doi:10.1097/00000542-200406000-00019 · Cited by 98 · cited 1×
“Tissue oxygen saturation is believed to be correlated with central arterial oxygen saturation and therefore with peripheral arterial oxygen saturation as measured with pulse oximeters [12].”
BackgroundHeart rate measurement in neonatal patients using a webcamera
Scalise, L., Bernacchia, N., Ercoli, I., & Marchionni, P. (2012) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2012.6226654 · Cited by 77 · cited 1×
“Camera-based non-contact estimation of heart rate in the NICU using standard video cameras was first reported in 2012 [2].”
MethodBlanik, N., Abbas, A. K., Venema, B., Blazek, V., & Leonhardt, S. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.1.016012 · Cited by 58 · cited 1×
“The use of standard cameras and thermal imaging is further explored in [8].”
MethodIntelligent neonatal monitoring based on a virtual thermal sensor
Abbas, A. K., & Leonhardt, S. K. (2014) · BMC Medical Imaging · doi:10.1186/1471-2342-14-9 · Cited by 52 · cited 1×
“These authors later expanded their methodology to enable them to track several geometric regions of interest over the neonate’s body [7].”
Background
Cited by
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
“Heart rate and SpO2 can also be estimated from imaging-PPG signals, increasing their utility [25], [27].”
Self-citationSecondary Analysis of Electronic Health Records
Data, M. C. (2016) · OAPEN (The OAPEN Foundation) · doi:10.1007/978-3-319-43742-2 · Cited by 246
Video-Based Heart Rate Measurement: Recent Advances and Future Prospects
Chen, X., Cheng, J., Song, R., Liu, Y., Ward, R., & Wang, Z. J. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2879706 · Cited by 227
“[104], [105], long-term monitoring, burn or trauma patient monitoring, driver status assessment [106], [107], and affec-”
BackgroundBarrera, A., Gee, C., Wood, A., Gibson, O., Bayley, D., & Geddes, J. (2020) · Evidence-Based Mental Health · doi:10.1136/ebmental-2019-300136 · Cited by 79
Non-Contact SpO2 Prediction System Based on a Digital Camera
Al-Naji, A., Khalid, G. A., Mahdi, J. F., & Chahl, J. (2021) · Applied Sciences · doi:10.3390/app11094255 · Cited by 61
Addison, P. S., Jacquel, D., Foo, D. M. H., & Borg, U. R. (2018) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-017-0076-1 · Cited by 24
Metadata
- Authors
- Villarroel, M., Guazzi, A., Jorge, J., Davis, S., Watkinson, P., Green, G., Shenvi, A., McCormick, K., & Tarassenko, L.
- Venue
- Healthcare Technology Letters
- Published
- 2014-09
- Volume
- 1
- Issue
- 3
- Pages
- 87-91
- ISSN
- 2053-3713 (ISSN-L)
- OpenAlex
- W2064560406
- Cited by
- 187
- References
- 10
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.