CoChat

DOSIS & DOSIS 3D: long-term dose monitoring onboard the Columbus Laboratory of the International Space Station (ISS)

Open access
Berger, Thomas, Przybyla, Bartos, Matthiä, Daniel, Reitz, Günther, Burmeister, Sönke, Labrenz, Johannes, Bilski, Pawel, Horwacik, Tomasz, Twardak, Anna, Hajek, Michael, Fugger, Manfred, Hofstätter, Christina, Sihver, Lembit, Palfalvi, Jozsef K., Szabo, Julianna, Stradi, Andrea, Ambrozova, Iva, Kubancak, Jan, Brabcova, Katerina Pachnerova, Vanhavere, Filip, Cauwels, Vanessa, Van Hoey, Olivier, Schoonjans, Werner, Parisi, Alessio, Gaza, Ramona, Semones, Edward, Yukihara, Eduardo G., Benton, Eric R., Doull, Brandon A., Uchihori, Yukio, Kodaira, Satoshi, Kitamura, Hisashi, Boehme, Matthias · 2016 · Journal of Space Weather and Space Climate
Cited by 87

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

The radiation environment encountered in space differs in nature from that on Earth, consisting mostly of highly energetic ions from protons up to iron, resulting in radiation levels far exceeding the ones present on Earth for occupational radiation workers. Since the beginning of the space era, the radiation exposure during space missions has been monitored with various active and passive radiation instruments. Also onboard the International Space Station (ISS), a number of area monitoring devices provide data related to the spatial and temporal variation of the radiation field in and outside the ISS. The aim of the DOSIS (2009–2011) and the DOSIS 3D (2012–ongoing) experiments was and is to measure the radiation environment within the European Columbus Laboratory of the ISS. These measurements are, on the one hand, performed with passive radiation detectors mounted at 11 locations within Columbus for the determination of the spatial distribution of the radiation field parameters and, on the other, with two active radiation detectors mounted at a fixed position inside Columbus for the determination of the temporal variation of the radiation field parameters. Data measured with passive radiation detectors showed that the absorbed dose values inside the Columbus Laboratory follow a pattern, based on the local shielding configuration of the radiation detectors, with minimum dose values observed in the year 2010 of 195–270 μGy/day and maximum values observed in the year 2012 with values ranging from 260 to 360 μGy/day. The absorbed dose is modulated by (a) the variation in solar activity and (b) the changes in ISS altitude.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1051/swsc/2016034

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Research works printed but not linked: 35

  1. Akselrod, 1990, Radiat. Prot. Dosim., 32, 15
  2. Beaujean, 1999a, Radiat. Prot. Dosim., 85, 223, 10.1093/oxfordjournals.rpd.a032839 · DOI · Paper page
  3. Beaujean, 1999b, Mutat. Res., 430, 183, 10.1016/S0027-5107(99)00129-3 · DOI
  4. Beaujean, 2002, Radiat. Meas., 35, 433, 10.1016/S1350-4487(02)00074-4 · DOI · Paper page
  5. Berger, 2008a, Z. Med. Phys., 18, 265, 10.1016/j.zemedi.2008.06.014 · DOI
  6. Berger, 2008b, Radiat. Meas., 43, 146, 10.1016/j.radmeas.2007.10.029 · DOI
  7. Berger, 2008, Radiat. Meas., 43, 580, 10.1016/j.radmeas.2007.12.004 · doi:10.1016/j.radmeas.2007.12.004
  8. Berger, 2013, Radiat. Res., 180, 622, 10.1667/RR13148.1 · DOI
  9. Berger, 2015, Int. J. Astrobiol., 14, 27, 10.1017/S1473550414000548 · DOI
  10. Bilski, 2006, Nucl. Instrum. Methods B, 251, 121, 10.1016/j.nimb.2006.05.012 · DOI
  11. Bilski, 2010, Radiat. Meas., 45, 1495, 10.1016/j.radmeas.2010.05.013 · DOI
  12. Bilski, 2011, Radiat. Meas., 46, 1680, 10.1016/j.radmeas.2011.03.023 · DOI
  13. Bilski, 2013, Radiat. Meas., 56, 303, 10.1016/j.radmeas.2013.01.045 · DOI
  14. Bilski, 2016, Radiat. Meas., 88, 33, 10.1016/j.radmeas.2016.02.029 · DOI
  15. Burgkhardt, 2006, Radiat. Prot. Dosim., 120, 83, 10.1093/rpd/nci597 · doi:10.1093/rpd/nci597
  16. Caffrey, 2011, Adv. Space Res., 47, 563, 10.1016/j.asr.2010.10.005 · DOI
  17. Gaza, 2006, Radiat. Prot. Dosim., 120, 354, 10.1093/rpd/nci574 · doi:10.1093/rpd/nci574
  18. Guelev, 1994, Radiat. Prot. Dosim., 51, 35, 10.1093/oxfordjournals.rpd.a082119 · doi:10.1093/oxfordjournals.rpd.a082119
  19. Hajek, 2008, Radiat. Meas., 43, 1135, 10.1016/j.radmeas.2007.12.015 · doi:10.1016/j.radmeas.2007.12.015
  20. Kodaira, 2014, Adv. Space. Res., 53, 1, 10.1016/j.asr.2013.10.018 · DOI · Paper page
  21. Labrenz, 2015, J. Space Weather Space Clim., 5, A38, 10.1051/swsc/2015039 · DOI · Paper page
  22. Lishnevskii, 2012, Cosmic Res., 50, 319, 10.1134/S0010952512040028 · DOI
  23. Nelson, 2016, Radiat. Res., 185, 349, 10.1667/RR14311.1 · DOI · Paper page
  24. Pachnerová Brabcová, 2013, Nucl. Instrum. Methods Phys. Res. A, 713, 5, 10.1016/j.nima.2013.03.012 · doi:10.1016/j.nima.2013.03.012
  25. Pálfalvi, 2009, Radiat. Meas., 44, 724, 10.1016/j.radmeas.2009.10.045 · doi:10.1016/j.radmeas.2009.10.045
  26. Puchalska, 2014, Radiat. Environ. Biophys., 53, 719, 10.1007/s00411-014-0560-7 · DOI
  27. Reitz, 2008, Z. Med. Phys., 18, 233, 10.1016/j.zemedi.2008.06.015 · DOI
  28. Reitz, 1998, Adv. Space Res., 22, 495, 10.1016/S0273-1177(98)01069-2 · DOI · Paper page
  29. Sawakuchi, 2008, J. Appl. Phys., 104, 124903, 10.1063/1.3041655 · doi:10.1063/1.3041655
  30. Spurny, 2008, Radiat. Meas., 44, 944, 10.1016/j.radmeas.2007.11.041 · doi:10.1016/j.radmeas.2007.11.041
  31. Vanhavere, 2008, Radiat. Meas., 43, 694, 10.1016/j.radmeas.2007.12.002 · DOI
  32. Yasuda, 2005, Radiat. Meas., 40, 311, 10.1016/j.radmeas.2005.02.013 · doi:10.1016/j.radmeas.2005.02.013
  33. Yukihara, 2006, Radiat. Meas., 41, 1126, 10.1016/j.radmeas.2006.05.027 · DOI
  34. Zhou, 2007a, Adv. Space Res., 40, 1575, 10.1016/j.asr.2006.12.003 · doi:10.1016/j.asr.2006.12.003
  35. Zhou, 2007b, Nucl. Instrum. Methods A, 580, 1283, 10.1016/j.nima.2007.06.091 · DOI

Cited by

See all 87

Metadata

Authors
Berger, T., Przybyla, B., Matthiä, D., Reitz, G., Burmeister, S., Labrenz, J., Bilski, P., Horwacik, T., Twardak, A., Hajek, M., Fugger, M., Hofstätter, C., Sihver, L., Palfalvi, J. K., Szabo, J., Stradi, A., Ambrozova, I., Kubancak, J., Brabcova, K. P., Vanhavere, F., Cauwels, V., Van Hoey, O., Schoonjans, W., Parisi, A., Gaza, R., Semones, E., Yukihara, E. G., Benton, E. R., Doull, B. A., Uchihori, Y., Kodaira, S., Kitamura, H., & Boehme, M.
Venue
Journal of Space Weather and Space Climate
Publisher
EDP Sciences
Published
2016
Volume
6
Issue
A39
Pages
A39
ISSN
2115-7251 (ISSN-L)
OpenAlex
W2553380712
Cited by
87
References
7
FWCI
9.80
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: DOSIS & DOSIS 3D: long-term dose monitoring onboard the Columbus Laboratory of the International Space Station (ISS). https://app.cochat.ai/papers/10.1051/swsc/2016034
The paper
Berger, T., Przybyla, B., Matthiä, D., Reitz, G., Burmeister, S., Labrenz, J., Bilski, P., Horwacik, T., Twardak, A., Hajek, M., Fugger, M., Hofstätter, C., Sihver, L., Palfalvi, J. K., Szabo, J., Stradi, A., Ambrozova, I., Kubancak, J., Brabcova, K. P., . . . Boehme, M. (2016). DOSIS & DOSIS 3D: long-term dose monitoring onboard the Columbus Laboratory of the International Space Station (ISS). Journal of Space Weather and Space Climate. https://doi.org/10.1051/swsc/2016034

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.