CoChat

Catheter ablation of atrial flutter due to amiodarone therapy for paroxysmal atrial fibrillation

Reithmann, C · 2000 · European Heart Journal
Cited by 86

The DOI matches its Crossref record.

Abstract

AIMS: Antiarrhythmic drug treatment for atrial fibrillation can cause atrial flutter-like arrhythmias. The aim of this study was to clarify the effect of catheter ablation of the tricuspid annulus-vena cava inferior isthmus on amiodarone-induced atrial flutter and to determine the incidence of atrial fibrillation after catheter ablation of amiodarone-induced atrial flutter in comparison to regular typical flutter. METHODS AND RESULTS: Among 92 consecutive patients with typical atrial flutter who underwent isthmus ablation 28 patients had atrial flutter without a history of previous atrial fibrillation (group I), 10 patients had atrial flutter following the initiation of amiodarone therapy for paroxysmal atrial fibrillation (group II) and 54 patients had atrial flutter and atrial fibrillation (group III). Atrial cycle length during atrial flutter in amiodarone-treated patients (group II) (277+/-24 ms) was significantly longer as compared to the cycle length of atrial flutter in group I (247+/-33 ms) and group III patients (235+/-28 ms). The rate of successful transient entrainment and overdrive stimulation to sinus rhythm was not different between patients with (60%) or without amiodarone therapy (group I: 71%, group III: 53%). Successful isthmus ablation with bidirectional conduction block eliminating right atrial flutter was achieved in 90% of amiodarone-treated patients and 93% of patients without amiodarone therapy. In the amiodarone-treated patient group atrial conduction times during pacing in sinus rhythm were significantly prolonged by 20-30% before and after ablation in all regions of the reentrant circuit. During a mean follow-up of 8+/-3 months post-ablation, atrial fibrillation recurred in two of 10 patients on continued amiodarone therapy after successful isthmus ablation. Thus, successful catheter ablation of atrial flutter due to amiodarone therapy was associated with a markedly lower recurrence rate of paroxysmal atrial fibrillation (20%) as compared to patients with atrial flutter plus preexisting paroxysmal atrial fibrillation (76%) and was similar to the outcome of patients with successful atrial flutter ablation without preexisting atrial fibrillation (25%). CONCLUSION: These data suggest that isthmus ablation with bidirectional block and continuation of amiodarone therapy is an effective therapy for the treatment of atrial flutter due to amiodarone therapy for paroxysmal atrial fibrillation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/euhj.1999.1865

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Reithmann, C.
Venue
European Heart Journal
Published
2000-04-01
Volume
21
Issue
7
Pages
565-572
ISSN
0195-668X (ISSN-L)
OpenAlex
W2120944678
Cited by
86
References
0
FWCI
6.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.