Targeted Muscle Reinnervation and Advanced Prosthetic Arms
Open accessThe DOI matches its Crossref record; 37 of the 41 references it cites were found in a registry or an index.
Abstract
Targeted muscle reinnervation (TMR) is a surgical procedure used to improve the control of upper limb prostheses. Residual nerves from the amputated limb are transferred to reinnervate new muscle targets that have otherwise lost their function. These reinnervated muscles then serve as biological amplifiers of the amputated nerve motor signals, allowing for more intuitive control of advanced prosthetic arms. Here the authors provide a review of surgical techniques for TMR in patients with either transhumeral or shoulder disarticulation amputations. They also discuss how TMR may act synergistically with recent advances in prosthetic arm technologies to improve prosthesis controllability. Discussion of TMR and prosthesis control is presented in the context of a 41-year-old man with a left-side shoulder disarticulation and a right-side transhumeral amputation. This patient underwent bilateral TMR surgery and was fit with advanced pattern-recognition myoelectric prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This can help the transmission of sensory feedback and the attainment of electromyographic (EMG) signals by surface electrodes from the reinnervated site to control the prosthetic limb (Kung et al., 2013; Cheesborough et al., 2015).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Cheesborough et al., 2015
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Consequently, implanted amputees can control a limited number of independent movements (11).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [11]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Self-citationScheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Limb Amputation and Limb Deficiency: Epidemiology and Recent Trends in the United States
DILLINGHAM, T. R., PEZZIN, L. E., & MACKENZIE, E. J. (2002) · Southern Medical Journal · doi:10.1097/00007611-200208000-00018 · Cited by 822
Osseointegration in skeletal reconstruction and rehabilitation: a review.
Brånemark, R., Brånemark, P., Rydevik, B. L., & Myers, R. R. (2001) · PubMed · Cited by 664
Jensen, T. S., Krebs, B., Nielsen, J., & Rasmussen, P. (1985) · Pain · doi:10.1016/0304-3959(85)90090-9 · Cited by 587
A Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518
A Clinical Perspective on Common Forms of Acquired Heterotopic Ossification
GARLAND, D. E. (1991) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199102000-00003 · Cited by 447
Quantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
Self-citationTargeted Muscle Reinnervation: A Novel Approach to Postamputation Neuroma Pain
Souza, J. M., Cheesborough, J. E., Ko, J. H., Cho, M. S., Kuiken, T. A., & Dumanian, G. A. (2014) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-014-3528-7 · Cited by 407
Self-citationJensen, T. S., Krebs, B., Nielsen, J., & Rasmussen, P. (1983) · Pain · doi:10.1016/0304-3959(83)90097-0 · Cited by 392
Jiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269
Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording
Weir, R. F., Troyk, P. R., DeMichele, G. A., Kerns, D. A., Schorsch, J. F., & Maas, H. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005942 · Cited by 266
Decoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215
Self-citation(2011) · SpringerReference · doi:10.1007/springerreference_38489 · Cited by 165
Improved Myoelectric Prosthesis Control Using Targeted Reinnervation Surgery: A Case Series
Miller, L. A., Stubblefield, K. A., Lipschutz, R. D., Lock, B. A., & Kuiken, T. A. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.911817 · Cited by 157
Self-citationA multiple-layer finite-element model of the surface EMG signal
Lowery, M. M., Stoykov, N. S., Taflove, A., & Kuiken, T. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.995683 · Cited by 152
Self-citationFischer, H. (2013) · University of North Texas Digital Library (University of North Texas) · Cited by 140
OʼShaughnessy, K. D., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., Stubblefield, K., & Kuiken, T. A. (2008) · The Journal of Bone & Joint Surgery · doi:10.2106/jbjs.g.00268 · Cited by 123
Self-citationPatient Training for Functional Use of Pattern Recognition–Controlled Prostheses
Simon, A. M., Lock, B. A., & Stubblefield, K. A. (2012) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e3182515437 · Cited by 102
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-5 · Cited by 101
Self-citationMr, U., Nakagawa, M., Nakata, N., & Nogami, H. (1978) · PubMed · Cited by 94
The Effects of Targeted Muscle Reinnervation on Neuromas in a Rabbit Rectus Abdominis Flap Model
Kim, P. S.-H., Ko, J. H., O'Shaughnessy, K. K., Kuiken, T., Pohlmeyer, E. A., & Dumanian, G. A. (2012) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2012.04.044 · Cited by 90
Self-citationThe i-LIMB Hand and the DMC Plus Hand Compared: A Case Report
Van Der Niet, O., Reinders-Messelink, H. A., Bongers, R. M., Bouwsema, H., & Van Der Sluis, C. K. (2010) · Prosthetics & Orthotics International · doi:10.3109/03093641003767207 · Cited by 87
THE PLIGHT OF THE TRAUMATIC AMPUTEE
Pierce, R. O., Kernek, C. B., & Ambrose, T. A. (1993) · Orthopedics · doi:10.3928/0147-7447-19930701-08 · Cited by 82
Cheesborough, J. E., Souza, J. M., Dumanian, G. A., & Bueno, R. A. (2014) · HAND · doi:10.1007/s11552-014-9602-5 · Cited by 74
Self-citationTwo-degree-of-freedom powered prosthetic wrist
Kyberd, P., Lemaire, E. D., Scheme, E., MacPhail, C. M., Goudreau, L., Bush, G., & Brookeshaw, M. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.07.0137 · Cited by 65
Hargrove, L. J., Lock, B. A., & Simon, A. M. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609821 · Cited by 63
Tkach, D. C., Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2302799 · Cited by 52
Self-citationTreatment of neuromas about a major amputation stump
Wood, V. E., & Mudge, M. K. (1987) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(87)80297-6 · Cited by 52
Medynski, C., & Rattray, B. (2011) · DukeSpace (Duke University) · Cited by 50
Forearm bone-anchored amputation prosthesis: A case study on the osseointegration
Palmquist, A., Jarmar, T., Emanuelsson, L., Brånemark, R., Engqvist, H., & Thomsen, P. (2008) · Acta Orthopaedica · doi:10.1080/17453670710014806 · Cited by 43
The Angulation Osteotomy of Above-elbow Stumps
Marquardt, E., & Neff, G. (1974) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197410000-00027 · Cited by 35
Ko, J. H., Kim, P., O’Shaughnessy, K. D., Ding, X., Kuiken, T., & Dumanian, G. A. (2011) · Journal of Brachial Plexus and Peripheral Nerve Injury · doi:10.1186/1749-7221-6-8 · Cited by 21
Self-citationNovel model for end-neuroma formation in the amputated rabbit forelimb
Kim, P. S.-H., Ko, J. H., O’Shaughnessy, K. D., Kuiken, T., & Dumanian, G. A. (2010) · Journal of Brachial Plexus and Peripheral Nerve Injury · doi:10.1186/1749-7221-5-6 · Cited by 18
Self-citationSurgical Techniques for Targeted Muscle Reinnervation
Dumanian, G. A., & Souza, J. M. (2013) · Series in medical physics and biomedical engineering · doi:10.1201/b15079-4 · Cited by 6
Self-citationSurgical and Functional Outcomes of Targeted Muscle Reinnervation
Miller, L. A., Stubblefield, K. A., Lipschutz, R. D., Lock, B. A., Souza, J. M., Dumanian, G. A., & Kuiken, T. (2013) · Series in medical physics and biomedical engineering · doi:10.1201/b15079-10 · Cited by 4
Self-citation
Research works printed but not linked: 8
- [3]Sears H H. St Louis, MO: Mosby; 1992. Trends in upper-extremity prosthetics development; pp. 345–356. [[Google Scholar](https://scholar.google.com/scholar_lookup?Sears%20H%20H.%20St%20Louis,%20MO:%20Mosby;%201992.%20Trends%20in%20upper-extremity%20prosthetics%20development;%20pp.%20345%E2%80%93356.)]
- [15]Dumanian G A. Philadelphia, PA: Wolters Kluwer; 2013. Targeted muscle reinnervation and upper limb amputation; pp. 900–907. [[Google Scholar](https://scholar.google.com/scholar_lookup?Dumanian%20G%20A.%20Philadelphia,%20PA:%20Wolters%20Kluwer;%202013.%20Targeted%20muscle%20reinnervation%20and%20upper%20limb%20amputation;%20pp.%20900%E2%80%93907.)]
- [21]Williams T W. New York, NY: Demos Medical Publishing; 2004. Control of powered upper extremity prostheses; pp. 207–224. [[Google Scholar](https://scholar.google.com/scholar_lookup?Williams%20T%20W.%20New%20York,%20NY:%20Demos%20Medical%20Publishing;%202004.%20Control%20of%20powered%20upper%20extremity%20prostheses;%20pp.%20207%E2%80%93224.)]
- [32]Kuiken T A Turner K Soltys N Dumanian G A First clinical fitting of an individual after bilateral TMR with intuitive pattern recognition control Paper presented at: Myoelectric Controls Symposium; August 18–24, 2014; Fredericton, New Brunswick, Canada
- [35]Kuiken T A. Chicago, IL: Rehabilitation Institute of Chicago; 2014. Application of Targeted Reinnervation for People with Transradial Amputation (NIH R01HD081525) [[Google Scholar](https://scholar.google.com/scholar_lookup?Kuiken%20T%20A.%20Chicago,%20IL:%20Rehabilitation%20Institute%20of%20Chicago;%202014.%20Application%20of%20Targeted%20Reinnervation%20for%20People%20with%20Transradial%20Amputation%20(NIH%20R01HD081525))]
- [41]Sensinger J Lipsey J Sutton L Thomas A Development of a lightweight, low-cost, myoelectric prosthesis Paper presented at: 39th Annual Meeting and Scientific Symposium of the American Academy of Orthotists & Prosthetists; February 20-23, 2013; Orlando, FL
- [42]Sears H H Iversen E K Christenson J Jacobs T Integrated system of new electric TD and wrist components - Stage 1 developments Paper presented at: Myoelectric Controls Symposium; August 18–24, 2014; Fredericton, New Brunswick, Canada
- [46]Bercich R A Joseph J Gall O Z Maeng J Kim Y-J Irazoqui P P Implantable device for intramuscular myoelectric signal recording Paper presented at: The 34th Annual International Conference of the IEEE EMBS; August 28–September 1, 2012; San Diego, CA
Cited by
Farina, D., Vujaklija, I., Sartori, M., Kapelner, T., Negro, F., Jiang, N., Bergmeister, K., Andalib, A., Principe, J., & Aszmann, O. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0025 · Cited by 359
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291
Targeted Muscle Reinnervation in the Upper Extremity Amputee: A Technical Roadmap
Gart, M. S., Souza, J. M., & Dumanian, G. A. (2015) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2015.06.119 · Cited by 123
“In the absence of viable muscle targets, free muscle transfers can be combined with TMR, but a more detailed discussion of this approach is beyond the scope of this review.(6,7) Finally, residual limb soft tissue quality should be assessed before surgery.”
BackgroundSelf-citationInterfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
Innervation: the missing link for biofabricated tissues and organs
Das, S., Gordián‐Vélez, W. J., Ledebur, H. C., Mourkioti, F., Rompolas, P., Chen, H.-C. I., Serruya, M. D., & Cullen, D. K. (2020) · npj Regenerative Medicine · doi:10.1038/s41536-020-0096-1 · Cited by 121
Metadata
- Authors
- Cheesborough, J., Smith, L., Kuiken, T., & Dumanian, G.
- Affiliations
- Northwestern University (US)
- Corresponding author
- Dumanian, Gregory
- Venue
- Seminars in Plastic Surgery
- Publisher
- Georg Thieme Verlag KG
- Published
- 2015-02-04
- Volume
- 29
- Issue
- 01
- Pages
- 062-072
- ISSN
- 1535-2188 (ISSN-L)
- 1536-0067
- PMC
- PMC4317279
- OpenAlex
- W2065987302
- Cited by
- 206
- References
- 41
- Citations by year
- 2026: 18 · 2025: 18 · 2024: 20 · 2023: 24 · 2022: 21 · 2021: 26 · 2020: 29 · 2019: 21 · 2018: 12 · 2017: 11 · 2016: 4 · 2015: 2
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Seminars in Plastic Surgery (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Keywords
- targeted muscle reinnervation, upper limb prosthesis, prosthetic control, transhumeral amputation, reinnervation, amputee rehabilitation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.