Anticardiolipin Antibody Assay: a Methodological Analysis for a better Consensus in Routine Determinations: A Cooperative Project of the European Antiphospholipid Forum
The DOI matches its Crossref record.
Abstract
Summary: Despite the widely recognized practical importance of anticardiolipin (aCL) ELISA, the reliability of this test has been recently discussed. In order to investigate this area on European scale, we sent to 30 experienced centers a questionnaire focusing on the diagnostic procedures applied to patients with antiphospholipid syndrome (APS) and on the detailed protocols used to perform aCL. Anticardiolipin ELISA was found to be the most frequently performed test in patients with suspected APS, but significant difference was shown among the various protocols. The cross-laboratory multiple examination of ten serum samples evaluated independently by the 24 centers pointed out the difficulty in getting comparable results. Therefore a “consensus” protocol was derived from the aCL methods giving the best performance. The materials and reagents necessary to perform the “consensus” method, including, as putative standards, one IgG and one IgM monoclonal antibody (HCAL and EY2C9) were distributed to 19 Centers. The results of one IgG and one IgM aCL high positive sera measured in serial dilutions were compared. A progressive decrease in the variability of the values obtained for a given sample appeared evident when all the laboratories used the same standard, in their own in-house ELISA and even more in the “consensus” ELISA. Our data show that aCL ELISA standardization is necessary in order to obtain comparable results in different laboratories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
MIYAKIS, S., LOCKSHIN, M. D., ATSUMI, T., BRANCH, D. W., BREY, R. L., CERVERA, R., DERKSEN, R. H. W. M., DE GROOT, P. G., KOIKE, T., MERONI, P. L., et al. (2006) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2006.01753.x · Cited by 7,203
Self-citationGalli, M., Luciani, D., Bertolini, G., & Barbui, T. (2003) · Blood · doi:10.1182/blood-2002-02-0441 · Cited by 972
Cervera, R., Serrano, R., Pons-Estel, G. J., Ceberio-Hualde, L., Shoenfeld, Y., de Ramón, E., Buonaiuto, V, Jacobsen, S., Zeher, M. M., Tarr, T., et al. (2015) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2013-204838 · Cited by 974
Self-citationManagement of Antiphospholipid Antibody Syndrome: A Systematic Review
Lim, W., Crowther, M. A., & Eikelboom, J. W. (2006) · JAMA · doi:10.1001/jama.295.9.1050 · Cited by 448
Fischetti, F., Durigutto, P., Pellis, V., Debeus, A., Macor, P., Bulla, R., Bossi, F., Ziller, F., Sblattero, D., Meroni, P., et al. (2005) · Blood · doi:10.1182/blood-2005-03-1319 · Cited by 351
Self-citationRaschi, E., Testoni, C., Bosisio, D., Borghi, M. O., Koike, T., Mantovani, A., & Meroni, P. L. (2003) · Blood · doi:10.1182/blood-2002-08-2349 · Cited by 306
Self-citationCervera, R., Khamashta, M. A., Shoenfeld, Y., Camps, M. T., Jacobsen, S., Kiss, E., Zeher, M. M., Tincani, A., Kontopoulou-Griva, I., Galeazzi, M., et al. (2009) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2008.093179 · Cited by 286
“Laboratory studies The anticardiolipin antibodies (aCL) of the IgG and IgM isotypes were measured by a b2 glycoprotein I (b2GPI)dependent enzyme-linked immunosorbent assay (ELISA).(8) They were considered positive if present in medium to high titre (.”
MethodSelf-citationOtomo, K., Atsumi, T., Amengual, O., Fujieda, Y., Kato, M., Oku, K., Horita, T., Yasuda, S., & Koike, T. (2012) · Arthritis & Rheumatism · doi:10.1002/art.33340 · Cited by 254
“The presence of aPL defines the APS; thus, the greatest efforts have been made since the mid 1980s, when aCL were described (40,41).”
BackgroundSelf-citationManagement of the obstetric antiphospholipid syndrome
Derksen, R. H. W. M., Khamashta, M. A., & Branch, D. W. (2004) · Arthritis & Rheumatism · doi:10.1002/art.20105 · Cited by 202
Pierangeli, S., Groot, P. D., Dlott, J., Favaloro, E., Harris, E., Lakos, G., Ortel, T., Meroni, P., Otomo, K., Pengo, V, et al. (2011) · Lupus · doi:10.1177/0961203310395055 · Cited by 180
Self-citationZuily, S., Regnault, V., Selton-Suty, C., Eschwège, V., Bruntz, J.-F., Bode-Dotto, E., De Maistre, E., Dotto, P., Perret-Guillaume, C., Lecompte, T., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.028522 · Cited by 178
RUFFATTI, A., OLIVIERI, S., TONELLO, M., BORTOLATI, M., BISON, E., SALVAN, E., FACCHINETTI, M., & PENGO, V. (2008) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2008.03121.x · Cited by 134
Antiphospholipid antibody testing and standardization
Devreese, K. M. J. (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12234 · Cited by 98
Invitation to a debate on the serological criteria that define the antiphospholipid syndrome
GALLI, M., REBER, G., DE MOERLOOSE, P., & DE GROOT, P. G. (2008) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2008.02862.x · Cited by 85
Laboratory diagnosis of the antiphospholipid syndrome: a plethora of obstacles to overcome
Devreese, K., & Hoylaerts, M. F. (2009) · European Journal Of Haematology · doi:10.1111/j.1600-0609.2009.01243.x · Cited by 78
“A recent survey on the performance of aCL testing revealed a correct interpretation of positive and negative samples, but with a high variability of the reported numerical data (21), a problem that can only be solved by uniform procedures and materials and by the use of a standard (21, 73).”
BackgroundNAESS, I. A., CHRISTIANSEN, S. C., CANNEGIETER, S. C., ROSENDAAL, F. R., & HAMMERSTROEM, J. (2006) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2005.01691.x · Cited by 74
Chayoua, W., Kelchtermans, H., Moore, G. W., Musiał, J., Wahl, D., de Laat, B., & Devreese, K. M. J. (2018) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14261 · Cited by 79
Vandevelde, A., Chayoua, W., de Laat, B., Gris, J., Moore, G. W., Musiał, J., Zuily, S., Wahl, D., & Devreese, K. M. J. (2022) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15585 · Cited by 66
Tripodi, A., Mancuso, M. E., Chantarangkul, V., Clerici, M., Bader, R., Meroni, P. L., Santagostino, E., & Mannucci, P. M. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.054312 · Cited by 44
“Relevant to this is the persistent, between-laboratory variability of aPL assay results (12, 21).”
BackgroundSelf-citation
Metadata
- Authors
- Allegri, F., Sanmarco, M., Cinquini, M., Taglietti, M., Balestrieri, G., Koike, T., Ichikawa, K., Meroni, P., Boffa, M. C., & Tincani, A.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 2001
- Volume
- 86
- Issue
- 08
- Pages
- 575-583
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W1927965016
- Cited by
- 183
- References
- 0
- FWCI
- 7.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.