Uncertain Value of Electronic Fetal Monitoring in Predicting Cerebral Palsy
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Electronic monitoring of the fetal heart rate is commonly performed, in part to detect hypoxia during delivery that may result in brain injury. It is not know whether specific abnormalities on electronic fetal monitoring are related to the risk of cerebral palsy. METHODS: Among 155,636 children born from 1983 through 1985 in four California counties, we identified singleton infants with birth weights of at least 2500 g who survived to three years of age and had moderate or severe cerebral palsy. The children with cerebral palsy were compared with randomly selected control children with respect to characteristics noted in the birth records. RESULTS: Seventy-eight of 95 children with cerebral palsy and 300 of 378 controls underwent intrapartum fetal monitoring. Characteristics found to be associated with an increased risk of cerebral palsy were multiple late decelerations in the heart rate, commonly defined as slowing of the heart rate well after the onset of uterine contractions (odds ratio, 3.9; 95 percent confidence interval, 1.7 to 9.3), and decreased beat-to-beat variability of the heart rate (odds ratio, 2.7; 95 percent confidence interval, 1.1 to 5.8); there was no association between the highest or lowest fetal heart rate recorded for each child and the risk of cerebral palsy. Even after adjustment for other risk factors, the association of abnormalities on fetal monitoring with an increased risk of cerebral palsy persisted (adjusted odds ratio, 2.7; 95 percent confidence interval, 1.4 to 5.4). The 21 children with cerebral palsy who had multiple late decelerations or decreased variability in heart rate on fetal monitoring represented only 0.19 percent of singleton infants with birth weights of 2500 g or more who had these fetal-monitoring findings, for a false positive rate of 99.8 percent. CONCLUSIONS: Specific abnormal findings on electronic monitoring of the fetal heart rate were associated with an increased risk of cerebral palsy. However, the false positive rate was extremely high. Since cesarean section is often performed when such abnormalities are noted and is associated with risk to the mother, our findings arouse concern that, if these indications were widely used, many cesarean sections would be performed without benefit and with the potential for harm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nelson, K. B., & Ellenberg, J. H. (1986) · New England Journal of Medicine · doi:10.1056/nejm198607103150202 · Cited by 930
Self-citationThe Dublin randomized controlled trial of intrapartum fetal heart rate monitoring
MacDonald, D., Grant, A., Sheridan-Pereira, M., Boylan, P., & Chalmers, I. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90619-2 · Cited by 631
Intrapartum electronic fetal heart rate monitoring versus intermittent auscultation: A meta-analysis
Vintzileos, A. (1995) · Obstetrics & Gynecology · doi:10.1016/0029-7844(94)00320-d · Cited by 271
Trends in perinatal mortality and cerebral palsy in Western Australia, 1967 to 1985.
Stanley, F. J., & Watson, L. (1992) · BMJ · doi:10.1136/bmj.304.6843.1658 · Cited by 238
Leveno, K. J., Cunningham, F. G., Nelson, S., Roark, M., Williams, M. L., Guzick, D., Dowling, S., Rosenfeld, C. R., & Buckley, A. (1986) · New England Journal of Medicine · doi:10.1056/nejm198609043151004 · Cited by 226
Antecedents of Cerebral Palsy: I. Univariate Analysis of Risks
Nelson, K. B. (1985) · American Journal of Diseases of Children · doi:10.1001/archpedi.1985.02140120077032 · Cited by 211
Self-citationThe Changing Panorama of Cerebral Palsy in Sweden: V. The Birth Year Period 1979–82
HAGBERG, B., HAGBERG, G., OLOW, I., & VON WENDT, L. (1989) · Acta Paediatrica · doi:10.1111/j.1651-2227.1989.tb11071.x · Cited by 194
Prenatal and perinatal factors in the etiology of cerebral palsy
Torfs, C. P., van den Berg, B. J., Oechsli, F. W., & Cummins, S. (1990) · The Journal of Pediatrics · doi:10.1016/s0022-3476(05)81615-4 · Cited by 192
Efficacy and safety of intrapartum electronic fetal monitoring: an update
THACKER, S., STROUP, D., & PETERSON, H. (1995) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(95)80027-1 · Cited by 185
Prenatal and perinatal factors in the etiology of cerebral palsy
Jongbloet, P. H. (1991) · The Journal of Pediatrics · doi:10.1016/s0022-3476(05)81875-x · Cited by 134
Cited by
Practice Bulletin No. 183: postpartum hemorrhage
(2017) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002351 · Cited by 1,406
Safe prevention of the primary cesarean delivery
Caughey, A. B., Cahill, A. G., Guise, J.-M., & Rouse, D. J. (2014) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2014.01.026 · Cited by 1,319
Alfirevic, Z., Devane, D., & Gyte, G. M. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006066 · Cited by 1,035
FIGO consensus guidelines on intrapartum fetal monitoring: Cardiotocography
Ayres‐de‐Campos, D., Spong, C. Y., Chandraharan, E., & Panel, F. I. F. M. E. C. (2015) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2015.06.020 · Cited by 911
“Reduced variability can occur due to central nervous system hypoxia/acidosis and resulting decreased sympathetic and parasympathetic activity, but it can also be due to previous cerebral injury [23], infection, administration of central nervous systemdepressants or parasympathetic blockers.”
BackgroundObstetric Care Consensus No. 1: Safe Prevention of the Primary Cesarean Delivery
(2014) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000444441.04111.1d · Cited by 762
Alfirevic, Z., Gyte, G. M., Cuthbert, A., & Devane, D. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006066.pub3 · Cited by 636
Interventions for Perinatal Hypoxic–Ischemic Encephalopathy
Vannucci, R. C., & Perlman, J. M. (1997) · Pediatrics · doi:10.1542/peds.100.6.1004 · Cited by 464
Amer-Wåhlin, I., Hellsten, C., Norén, H., Hagberg, H., Herbst, A., Kjellmer, I., Lilja, H., Lindoff, C., Månsson, M., Mårtensson, L., et al. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05703-8 · Cited by 402
van Handel, M., Swaab, H., de Vries, L. S., & Jongmans, M. J. (2007) · European Journal of Pediatrics · doi:10.1007/s00431-007-0437-8 · Cited by 376
The TOBY Study Group, Azzopardi, D., Brocklehurst, P., Edwards, D., Halliday, H., Levene, M., Thoresen, M., & Whitelaw, A. (2008) · BMC Pediatrics · doi:10.1186/1471-2431-8-17 · Cited by 360
Defining the pathogenesis and pathophysiology of neonatal encephalopathy and cerebral palsy
Hankins, G. (2003) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(03)00574-x · Cited by 308
Potentially asphyxiating conditions and spastic cerebral palsy in infants of normal birth weight
Nelson, K. B., & Grether, J. K. (1998) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(98)70387-4 · Cited by 300
Self-citationTemporal and demographic trends in cerebral palsy—Fact and fiction
Clark, S. L., & Hankins, G. D. V. (2003) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2003.204 · Cited by 289
Experimentally induced intrauterine infection causes fetal brain white matter lesions in rabbits
Yoon, B. H., Kim, C. J., Romero, R., Jun, J. K., Park, K. H., Choi, S. T., & Chi, J. G. (1997) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(97)70271-0 · Cited by 283
Shalak, L. F., Laptook, A. R., Velaphi, S. C., & Perlman, J. M. (2003) · Pediatrics · doi:10.1542/peds.111.2.351 · Cited by 249
Long-term outcome after neonatal hypoxic-ischaemic encephalopathy
de Vries, L. S., & Jongmans, M. J. (2010) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/adc.2008.148205 · Cited by 235
“The term NE is now more often used than perinatal asphyxia (PA). This is because PA is difficult to define and in order to be reliable, needs access to several markers which are not always available, such as fetal heart rate tracings, umbilical cord gases and reliable Apgar scores. Individually, these markers have bee…”
BackgroundCan We Prevent Cerebral Palsy?
Nelson, K. B. (2003) · New England Journal of Medicine · doi:10.1056/nejmsb035364 · Cited by 231
Self-citationDevane, D., Lalor, J. G., Daly, S., McGuire, W., Cuthbert, A., & Smith, V. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005122.pub5 · Cited by 213
Alfirevic, Z., Devane, D., & Gyte, G. M. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006066.pub2 · Cited by 208
The physiology of intrapartum fetal compromise at term
Turner, J. M., Mitchell, M. D., & Kumar, S. S. (2020) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2019.07.032 · Cited by 194
Prenatal medicine: The child is the father of the man*
Romero, R., & Romero, R. (2009) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767050902784171 · Cited by 193
Westgate, J. A., Wibbens, B., Bennet, L., Wassink, G., Parer, J. T., & Gunn, A. J. (2007) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2007.03.063 · Cited by 186
Fetal Hypoxia Insults and Patterns of Brain Injury: Insights from Animal Models
Gunn, A. J., & Bennet, L. (2009) · Clinics in Perinatology · doi:10.1016/j.clp.2009.06.007 · Cited by 184
“Despite the highly adverse outcomes of moderate to severe encephalopathy around birth(2) the predictive value for cerebral palsy of abnormal fetal heart rate patterns is consistently weak.(3) Indeed, even measures of total oxygen debt such as”
BackgroundRooks, J. (1999) · Journal of Nurse-Midwifery · doi:10.1016/s0091-2182(99)00060-9 · Cited by 177
Fetal Pulse Oximetry and Cesarean Delivery
Bloom, S. L., Spong, C. Y., Thom, E., Varner, M. W., Rouse, D. J., Weininger, S., Ramin, S. M., Caritis, S. N., Peaceman, A., Sorokin, Y., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa061170 · Cited by 160
Oxidative Metabolism, Apoptosis and Perinatal Brain Injury
Taylor, D. L., Edwards, A. D., & Mehmet, H. (1999) · Brain Pathology · doi:10.1111/j.1750-3639.1999.tb00213.x · Cited by 158
Timing of caesarean section according to urgency
Leung, T. Y., & Lao, T. T. (2013) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2012.09.005 · Cited by 68
Metadata
- Authors
- Nelson, K. B., Dambrosia, J. M., Ting, T. Y., & Grether, J. K.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1996-03-07
- Volume
- 334
- Issue
- 10
- Pages
- 613-619
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2330997682
- Cited by
- 532
- References
- 14
- FWCI
- 20.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.