Value of Electron-Beam Computed Tomography for the Noninvasive Detection of High-Grade Coronary-Artery Stenoses and Occlusions
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Reliable noninvasive assessment of coronary-artery stenoses and occlusions would constitute an advantage in the care of patients with known or suspected coronary artery disease. We investigated the accuracy of contrast-enhanced electron-beam computed tomography (CT) for the detection of high-grade coronary-artery stenoses and occlusions. METHODS: Electron-beam CT was performed in 125 patients. After intravenous injection of a contrast agent, 40 cross-sectional images of the heart were acquired during inspiration, triggered by the electrocardiogram in diastole. Three-dimensional reconstructions of the heart and coronary arteries were rendered to facilitate evaluation of the images. The proximal and middle segments of the major coronary arteries were evaluated for the presence or absence of high-grade stenoses and occlusions. The results were compared with those of invasive coronary angiography in a blinded fashion. RESULTS: Because of technical problems that impaired the quality of the images, 124 (25 percent) of the 500 coronary arteries studied (left main, left anterior descending, left circumflex, and right coronary) in a total of 125 patients were excluded from evaluation. No vessels could be evaluated in 19 patients (15 percent), and another 28 patients (22 percent) had one, two, or three vessels that could not be evaluated. In the remaining coronary arteries with adequate image quality, electron-beam CT permitted visualization of 69 of 75 high-grade stenoses and occlusions (sensitivity, 92 percent), whereas in 282 of 301 arteries, the absence of high-grade stenoses and occlusions was correctly detected (specificity, 94 percent). CONCLUSIONS: When image quality is adequate, electron-beam CT may be useful to detect or rule out high-grade coronary-artery stenoses and occlusions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256
A Preliminary Report Comparing Magnetic Resonance Coronary Angiography with Conventional Angiography
Manning, W. J., Li, W., & Edelman, R. R. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303253281202 · Cited by 544
Arad, Y., Spadaro, L. A., Goodman, K., Lledo-Perez, A., Sherman, S., Lerner, G., & Guerci, A. D. (1996) · Circulation · doi:10.1161/01.cir.93.11.1951 · Cited by 521
Budoff, M. J., Georgiou, D., Brody, A., Agatston, A. S., Kennedy, J., Wolfkiel, C., Stanford, W., Shields, P., Lewis, R. J., Janowitz, W. R., et al. (1996) · Circulation · doi:10.1161/01.cir.93.5.898 · Cited by 488
Detrano, R., Hsiai, T., Wang, S., Puentes, G., Fallavollita, J., Shields, P., Stanford, W., Wolfkiel, C., Georgiou, D., Budoff, M., et al. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00460-2 · Cited by 434
Hozumi, T., Yoshida, K., Ogata, Y., Akasaka, T., Asami, Y., Takagi, T., & Morioka, S. (1998) · Circulation · doi:10.1161/01.cir.97.16.1557 · Cited by 405
Post, J. C., van Rossum, A. C., Bronzwaer, J. G. F., de Cock, C. C., Hofman, M. B. M., Valk, J., & Visser, C. A. (1995) · Circulation · doi:10.1161/01.cir.92.11.3163 · Cited by 339
Johnson, L. W., Lozner, E. C., Johnson, S., Krone, R., Pichard, A. D., Vetrovec, G. W., Noto, T. J., & The Registry Committee of the Society for Cardiac Angiography and Interventions (1989) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/ccd.1810170103 · Cited by 317
Breen, J. F., Sheedy, P. F., Schwartz, R. S., Stanson, A. W., Kaufmann, R. B., Moll, P. P., & Rumberger, J. A. (1992) · Radiology · doi:10.1148/radiology.185.2.1410350 · Cited by 274
Moshage, W. E., Achenbach, S., Seese, B., Bachmann, K., & Kirchgeorg, M. (1995) · Radiology · doi:10.1148/radiology.196.3.7644633 · Cited by 205
Self-citationSchmermund, A., Rensing, B. J., Sheedy, P. F., Bell, M. R., & Rumberger, J. A. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00132-6 · Cited by 180
Post, J. C., van Rossum, A. C., Hofman, M. B., Valk, J., & Visser, C. A. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.6.8633453 · Cited by 176
Assessment of coronary artery stenosis by magnetic resonance imaging.
Pennell, D. J., Bogren, H. G., Keegan, J., Firmin, D. N., & Underwood, S. R. (1996) · Heart · doi:10.1136/hrt.75.2.127 · Cited by 158
Rumberger, J. A., Sheedy, P. F., Breen, J. F., Fitzpatrick, L. A., & Schwartz, R. S. (1996) · Mayo Clinic Proceedings · doi:10.4065/71.4.369 · Cited by 150
Second harmonic imaging of an intravenously administered echocardiographic contrast agent
Mulvagh, S. L., Foley, D. A., Aeschbacher, B. C., Klarich, K. K., & Seward, J. B. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00619-2 · Cited by 141
Proximal coronary artery stenosis: Three‐dimensional MRI with fat saturation and navigator echo
Müller, M. F., Fleisch, M., Kroeker, R. M., Chatterjee, T. K., Meier, B., & Vock, P. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070406 · Cited by 135
Evaluation of Coronary Artery Stenoses Using Electron-Beam CT and Multiplanar Reformation
Nakanishi, T., Ito, K., Imazu, M., & Yamakido, M. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199701000-00024 · Cited by 91
Coronary artery calcification: clinical significance and current methods of detection.
Stanford, W. L., Thompson, B. H., & Weiss, R. M. (1993) · American Journal of Roentgenology · doi:10.2214/ajr.161.6.8249716 · Cited by 84
Caiati, C., Aragona, P., Iliceto, S., & RIZZON, P. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)81521-x · Cited by 53
Delineation of extended lengths of coronary arteries by multiplane transesophageal echocardiography
Tardif, J., Vannan, M. A., Taylor, K., Schwartz, S. L., & Pandian, N. G. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90849-4 · Cited by 39
Cited by
Goodman, W. G., Goldin, J., Kuizon, B. D., Yoon, C., Gales, B., Sider, D., Wang, Y., Chung, J., Emerick, A., Greaser, L., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005183422003 · Cited by 2,509
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Self-citationNieman, K., Cademartiri, F., Lemos, P. A., Raaijmakers, R., Pattynama, P. M. T., & de Feyter, P. J. (2002) · Circulation · doi:10.1161/01.cir.0000037222.58317.3d · Cited by 956
Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses
Kim, W. Y., Danias, P. G., Stuber, M., Flamm, S. D., Plein, S., Nagel, E., Langerak, S. E., Weber, O. M., Pedersen, E. M., Schmidt, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010866 · Cited by 903
Coronary angiography with multi-slice computed tomography
Nieman, K., Oudkerk, M., Rensing, B. J., van Ooijen, P., Munne, A., van Geuns, R.-J., & de Feyter, P. J. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04058-7 · Cited by 725
Metadata
- Authors
- Achenbach, S., Moshage, W., Ropers, D., Nossen, J., & Daniel, W. G.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1998-12-31
- Volume
- 339
- Issue
- 27
- Pages
- 1964-1971
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2334010292
- Cited by
- 382
- References
- 22
- FWCI
- 34.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.