A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Open accessAbstract
BACKGROUND: Empirical antiarrhythmic therapy has not reduced mortality among patients with coronary artery disease and asymptomatic ventricular arrhythmias. Previous studies have suggested that antiarrhythmic therapy guided by electrophysiologic testing might reduce the risk of sudden death. METHODS: We conducted a randomized, controlled trial to test the hypothesis that electrophysiologically guided antiarrhythmic therapy would reduce the risk of sudden death among patients with coronary artery disease, a left ventricular ejection fraction of 40 percent or less, and asymptomatic, unsustained ventricular tachycardia. Patients in whom sustained ventricular tachyarrhythmias were induced by programmed stimulation were randomly assigned to receive either antiarrhythmic therapy, including drugs and implantable defibrillators, as indicated by the results of electrophysiologic testing, or no antiarrhythmic therapy. Angiotensin-converting-enzyme inhibitors and beta-adrenergic-blocking agents were administered if the patients could tolerate them. RESULTS: A total of 704 patients with inducible, sustained ventricular tachyarrhythmias were randomly assigned to treatment groups. Five-year Kaplan-Meier estimates of the incidence of the primary end point of cardiac arrest or death from arrhythmia were 25 percent among those receiving electrophysiologically guided therapy and 32 percent among the patients assigned to no antiarrhythmic therapy (relative risk, 0.73; 95 percent confidence interval, 0.53 to 0.99), representing a reduction in risk of 27 percent). The five-year estimates of overall mortality were 42 percent and 48 percent, respectively (relative risk, 0.80; 95 percent confidence interval, 0.64 to 1.01). The risk of cardiac arrest or death from arrhythmia among the patients who received treatment with defibrillators was significantly lower than that among the patients discharged without receiving defibrillator treatment (relative risk, 0.24; 95 percent confidence interval, 0.13 to 0.45; P<0.001). Neither the rate of cardiac arrest or death from arrhythmia nor the overall mortality rate was lower among the patients assigned to electrophysiologically guided therapy and treated with antiarrhythmic drugs than among the patients assigned to no antiarrhythmic therapy. CONCLUSIONS: Electrophysiologically guided antiarrhythmic therapy with implantable defibrillators, but not with antiarrhythmic drugs, reduces the risk of sudden death in high-risk patients with coronary disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Following the Multicenter Unsustained Tachycardia Trial (MUSTT) (Buxton et al., 1999), there is a role for AECG for NSVT detection in post-MI patients with LVEF 35%-40% as electrophysiologically guided ICD implantation improves survival”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Buxton et al., 1999
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“NSVT accompanied by inducibility of sustained VT during programmed ventricular stimulation was associated with an increased risk of SCD”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Buxton et al., 1999
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
The Statistical Analysis of Failure Time Data.
Aitkin, M. A., Kalbfleisch, J. D., & Prentice, R. L. (1981) · Biometrics · doi:10.2307/2530581 · Cited by 9,875
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
A Multiple Testing Procedure for Clinical Trials
O'Brien, P. C., & Fleming, T. R. (1979) · Biometrics · doi:10.2307/2530245 · Cited by 3,311
Mortality and Morbidity in Patients Receiving Encainide, Flecainide, or Placebo
Echt, D. S., Liebson, P. R., Mitchell, L. B., Peters, R. W., Obias-Manno, D., Barker, A. H., Arensberg, D., Baker, A., Friedman, L., Greene, H. L., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199103213241201 · Cited by 3,244
The AVID Investigators (1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,221
Discrete Sequential Boundaries for Clinical Trials
Lan, K. K. G., & DeMets, D. L. (1983) · Biometrika · doi:10.2307/2336502 · Cited by 2,310
Discrete sequential boundaries for clinical trials
GORDON LAN, K. K., & DEMETS, D. L. (1983) · Biometrika · doi:10.1093/biomet/70.3.659 · Cited by 2,310
Julian, D. G., CAMM, A. J., Frangin, G., Janse, M. J., Munoz, A., Pj, S., & Simon, P. (1997) · The Lancet · doi:10.1016/s0140-6736(96)09145-3 · Cited by 1,100
Research works printed but not linked: 1
- 10.2307/2281868 · DOI · Paper page
Cited by
Sorted by citations
Items 701–800 of 1,000
Delayed intrinsicoid deflection of the QRS complex is associated with sudden cardiac arrest
Darouian, N., Narayanan, K., Aro, A. L., Reinier, K., Uy‐Evanado, A., Teodorescu, C., Gunson, K., Jui, J., & Chugh, S. S. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.12.022 · Cited by 28
Heart Failure Due to Reduced Ejection Fraction: Medical Management.
Chavey, W. E., Hogikyan, R. V., Harrison, R. V., & Nicklas, J. M. (2017) · PubMed · Cited by 26
Cardiac Interventions in Patients With Active, Advanced Solid and Hematologic Malignancies
Leong, D. P., Cirne, F., Aghel, N., Vila, R. C. B., Cavalli, G. D., Ellis, P. M., Healey, J. S., Whitlock, R. P., Khalaf, D., Mian, H. S., et al. (2023) · JACC CardioOncology · doi:10.1016/j.jaccao.2023.05.008 · Cited by 30
Gibson, D. P., Kuntz, K. K., Levenson, J. L., & Ellenbogen, K. A. (2008) · EP Europace · doi:10.1093/europace/eun082 · Cited by 28
Pedretti, R. F. E., Curnis, A., Massa, R., Morandi, F., Tritto, M. V., Manca, M. L., Occhetta, E., Molon, G., Ferrari, G. M. D., Braga, S. S., et al. (2010) · EP Europace · doi:10.1093/europace/euq106 · Cited by 28
The Role of Antiarrhythmic Drug Therapy for the Prevention of Sudden Cardiac Death
Kamath, G. S., & Mittal, S. (2008) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2007.12.001 · Cited by 28
β2-Adrenoceptors and ventricular fibrillation
Altschuld, R. A. (2000) · Pharmacology & Therapeutics · doi:10.1016/s0163-7258(00)00075-9 · Cited by 28
Identifying the High Risk Patient with Coronary Artery Disease—Is Ejection Fraction All You Need?
Buxton, A. E. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.50150.x · Cited by 28
Self-citationProvidencia, R. A., Bovéda, S., Lambiase, P. D., Defaye, P., Algalarrondo, V., Sadoul, N., Piot, O., Klug, D., Perier, M., Bouzeman, A., et al. (2015) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2015.01.004 · Cited by 27
Ye, S., Grunert, M., Thune, J. J., Stephenson, K., Uno, H., Finn, P. V., McMurray, J. J. V., Velazquez, E. J., Califf, R. M., Pfeffer, M. A., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.990655 · Cited by 27
The Role of Electrophysiology Study in Risk Stratification of Sudden Cardiac Death
Thomas, K. E., & Josephson, M. E. (2008) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2008.05.001 · Cited by 27
Self-citationKinoshita, T., Hashimoto, K., Yoshioka, K., Miwa, Y., Yodogawa, K., Watanabe, E., Nakamura, K., Nakagawa, M., Nakamura, K., Watanabe, T., et al. (2019) · Journal of Cardiology · doi:10.1016/j.jjcc.2019.07.012 · Cited by 27
Menezes, A. D. S. (2004) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/b:jice.0000048569.71590.c5 · Cited by 27
Sex-dependent gene regulatory networks of the heart rhythm
Iacobaş, D. A., Iacobaş, S., Thomas, N., & Spray, D. C. (2009) · Functional & Integrative Genomics · doi:10.1007/s10142-009-0137-8 · Cited by 27
“In general, malignant ventricular arrhythmias and sudden cardiac death are less common in women than in men (Albert et al. 1996; Kannel et al. 1998; Buxton et al. 1999a, b; AVID 1997).”
BackgroundGravelin, L. M., Yuhas, J., Remetz, M. S., Radford, M. J., Foley, J., & Lampert, R. J. (2011) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.110.956987 · Cited by 27
Sotoodehnia, N. (2001) · Cardiovascular Research · doi:10.1016/s0008-6363(01)00260-7 · Cited by 27
Management of malignant ventricular arrhythmias and cardiac arrest
Fogel, R. I., & Prystowsky, E. N. (2000) · Critical Care Medicine · doi:10.1097/00003246-200010001-00009 · Cited by 27
Self-citationT Wave Oversensing in Implantable Cardioverter Defibrillators
Hsu, S. S., Mohib, S., Schroeder, A., & Deger, F. T. (2004) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/b:jice.0000035932.25722.f1 · Cited by 27
Sudden cardiac death and channelopathies: a review of implantable defibrillator therapy
Choi, G. R., Porter, C.-B. J., & Ackerman, M. J. (2004) · Pediatric Clinics of North America · doi:10.1016/j.pcl.2004.04.015 · Cited by 27
“The multicenter automatic defibrillator implant trial (MADIT) and multicenter unsustained tachycardia trial (MUSTT) studies showed a significant reduction in the risk of death in those who had implantation of an ICD versus those who received antiarrhythmic drugs [25–27].”
ResultBryant, J., Brodin, H., Loveman, E., & Clegg, A. J. (2007) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462307051586 · Cited by 27
Naccarelli, G. V., Wolbrette, D. L., & Luck, J. C. (2001) · Medical Clinics of North America · doi:10.1016/s0025-7125(05)70324-2 · Cited by 27
MR and CT assessment for ischemic cardiac disease
White, R. D. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20068 · Cited by 27
Weinbroum, A. A., Glick, A., Copperman, Y., Yashar, T., Rudick, V., & Flaishon, R. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200211000-00004 · Cited by 27
“patients (2), which concluded that this approach re-”
BackgroundT-Wave Alternans in the Sudden Cardiac Death in Heart Failure Trial Population
ROSENBAUM, D. S. (2008) · Circulation · doi:10.1161/circulationaha.108.818286 · Cited by 27
Delahaye, F., Bory, M., Cohen, A. A., Danchin, N., de Gévigney, G., Dellinger, A., Fraboulet, J.-Y., Gayet, J.-L., Guize, L., Iung, B., et al. (2001) · PubMed · Cited by 27
Alba, A. C., Fan, C. S., Manlhiot, C., Dipchand, A. I., Stehlik, J., & Ross, H. J. (2019) · Clinical Transplantation · doi:10.1111/ctr.13490 · Cited by 28
SALTZMAN, H. E. (2013) · Cardiology Clinics · doi:10.1016/j.ccl.2013.09.005 · Cited by 26
Allelic variants of SCN5A and risk of sudden cardiac arrest in patients with coronary artery disease
Stecker, E. C., Sono, M., Wallace, E. R., Gunson, K., Jui, J., & Chugh, S. S. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.01.029 · Cited by 27
Implantable Cardioverter–Defibrillator Use in Older Adults
Kramer, D. B., Matlock, D. D., Buxton, A. E., Goldstein, N. E., Goodwin, C., Green, A. R., Kirkpatrick, J. N., Knoepke, C. E., Lampert, R. J., Mueller, P. S., et al. (2015) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.114.001660 · Cited by 26
Self-citationFrancia, P., Balla, C., Uccellini, A., & Cappato, R. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01477.x · Cited by 26
Rao, M. P., Al‐Khatib, S. M., Pokorney, S. D., She, L., Romanov, A. B., Nicolau, J. C., Lee, K. L., Carson, P. E., Selzman, C. H., Stępińska, J., et al. (2017) · Circulation · doi:10.1161/circulationaha.116.026075 · Cited by 29
Self-citationPrimary Prevention of Sudden Cardiac Death Early Post-Myocardial Infarction
Elayi, C. S., Charnigo, R. J., Heron, P. M., Lee, B. K., & Olgin, J. E. (2017) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.117.005194 · Cited by 29
Zeitler, E. P., Al‐Khatib, S. M., Friedman, D. J., Han, J. Y., Poole, J. E., Bardy, G. H., Bigger, J. T., Buxton, A. E., Moss, A. J., Lee, K. L., et al. (2017) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13307 · Cited by 26
Self-citationGillis, A. M., Sheldon, R. S., Wyse, D. G., Duff, H. J., Cassidy, M. R., & Mitchell, L. B. (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2003.02328.x · Cited by 26
Proclemer, A., Ghidina, M., Cicuttini, G., Gregori, D., & FIORETTI, P. M. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00487.x · Cited by 26
Bruch, C., Bruch, C., Sindermann, J. R., BREITHARDT, G. E., & Gradaus, R. (2007) · EP Europace · doi:10.1093/europace/eum097 · Cited by 26
Recognizing and Managing Asymptomatic Left Ventricular Dysfunction
Albert, N. M., & Lewis, C. M. (2008) · Critical Care Nurse · doi:10.4037/ccn2008.28.2.20 · Cited by 26
Should stimulation therapy for congestive heart failure be combined with defibrillation backup?
Gaïta, F., Bocchiardo, M., Porciani, M. C., Vivalda, L., Colella, A., Donna, P. D., Caponi, D., Bruzzone, M., & Padeletti, L. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01229-7 · Cited by 26
Sudden Death after Myocardial Infarction — Who Needs Prophylaxis, and When?
Buxton, A. E. (2005) · New England Journal of Medicine · doi:10.1056/nejme058085 · Cited by 26
Self-citationKim, E., Carrigan, T., & Menon, V. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.01.066 · Cited by 25
Keegan, R. O., Yeung, C., & Baranchuk, A. M. (2020) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2020.27 · Cited by 25
Diretriz Brasileira de Dispositivos Cardíacos Eletrônicos Implantáveis – 2023
Teixeira, R. A., Fagundes, A. A., Baggio, J. M., de Oliveira, J. C., Medeiros, P. D. T. J., Valdigem, B. P., Teno, L. A. C., Silva, R. T., de Melo, C. S., Elías, J., et al. (2023) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20220892 · Cited by 53
Calò, L., Santo, T. D., Nuccio, F., Sciarra, L., Luca, L. D., Stefano, L. M. D. S., Piroli, E., Zuccaro, L. M., Rebecchi, M., Ruvo, E. D., et al. (2011) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00467.x · Cited by 25
Development of a preclinical model of ischemic cardiomyopathy in swine
Ishikawa, K., Ladage, D., Takewa, Y., Yaniz‐Galende, E., Chen, J., Tilemann, L. M., Sakata, S., Badimón, J. J., Hajjar, R. J., & Kawase, Y. (2011) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01103.2010 · Cited by 25
Predictors of Early Mortality in Patients Age 80 and Older Receiving Implantable Defibrillators
Ertel, D., Phatak, K., Makati, K. J., HOLLAND, M., Baig, S., KIM, M. H., Link, M. S., & PASSMAN, R. S. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02729.x · Cited by 25
Kwon, D. H., Hachamovitch, R., Adeniyi, A., Nutter, B., Popović, Z., Wilkoff, B. L., Desai, M. Y., Flamm, S. D., & Marwick, T. H. (2013) · Heart · doi:10.1136/heartjnl-2013-304261 · Cited by 25
Sanghera, R., Sanders, R., Husby, M. P., & Bentsen, J. G. (2014) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12550 · Cited by 25
Banasik, G., Segiet, O. A., Elwart, M., Szulik, M., Lenarczyk, R., Kalarus, Z. F., & Kukulski, T. (2016) · Herz · doi:10.1007/s00059-015-4398-9 · Cited by 25
Epidemiology, Risk Factors, and Outcomes of Out-of-Hospital Cardiac Arrest Caused by Stroke
Fukuda, T., Ohashi-Fukuda, N., Kondo, Y., Sera, T., Doi, K., & Yahagi, N. (2016) · Medicine · doi:10.1097/md.0000000000003107 · Cited by 25
Bergau, L., Willems, R., Sprenkeler, D. J., Fischer, T. H., Flevari, P. G., Hasenfuss, G. P., Katsaras, D. N., Kirova, A., Lehnart, S. E., Lüthje, L., et al. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2018.06.103 · Cited by 25
Rodríguez‐Zanella, H., Muraru, D., Secco, E., Boccalini, F., Azzolina, D., Aruta, P., Surkova, E., Genovese, D., Cavalli, G., Sammarco, G., et al. (2018) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2018.07.011 · Cited by 25
Mondesert, B. A., Bashir, J. G., Philippon, F., Dubuc, M., Amit, G., Exner, D. V., Joza, J. E., Birnie, D. H., Lane, C., Tsang, B., et al. (2018) · American Heart Journal · doi:10.1016/j.ahj.2018.09.008 · Cited by 25
Arawwawala, D., & Brett, S. J. (2007) · Critical Care · doi:10.1186/cc6139 · Cited by 25
Ermiş, C., Lurie, K. G., Zhu, A. X., COLLINS, J., VanHeel, L., Sakaguchi, S., Lü, F., Pham, S., & Benditt, D. G. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.04044.x · Cited by 25
Relation of Advanced Heart Failure Symptoms to Risk of Inappropriate Defibrillator Shocks
Hreybe, H., Ezzeddine, R., Barrington, W., Bazaz, R. R., Jain, S. K., Ngwu, O., & Saba, S. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.08.074 · Cited by 25
Morin, D. P., Zacks, E. S., Mauer, A. C., Ageno, S., Janik, M. J., Markowitz, S. M., Mittal, S., Iwai, S., Shah, B. K., Lerman, B. B., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.02.027 · Cited by 25
Management of Arrhythmias in Heart Failure
Ellison, K., Stevenson, W. G., Sweeney, M. O., Epstein, L. M., & Maisel, W. H. (2003) · Congestive Heart Failure · doi:10.1111/j.1527-5299.2003.00271.x · Cited by 25
Carroll, D. L., Hamilton, G. A., & Kenney, B. J. (2002) · European Journal of Cardiovascular Nursing · doi:10.1016/s1474-5151(02)00040-3 · Cited by 25
Physicians' knowledge and attitudes regarding implantable cardioverter-defibrillators.
Sherazi, S., Zaręba, W., Daubert, J. P., McNitt, S. A., Shah, A. H., Aktaş, M. K., & Block, R. (2010) · PubMed · Cited by 25
Bunch, T. J., White, R. D., Gersh, B. J., Shen, W.-K., Hammill, S. C., & Packer, D. L. (2004) · Mayo Clinic Proceedings · doi:10.4065/79.5.613 · Cited by 25
Changing Late Prognosis of Acute Myocardial Infarction
Hohnloser, S. H., & Gersh, B. J. (2003) · Circulation · doi:10.1161/01.cir.0000054211.00668.9b · Cited by 25
Temporal aspects of improved survival with the implanted defibrillator (MADIT-II)
Moss, A. J., Vyas, A. K., Greenberg, H., Case, R. B., Zaręba, W., Hall, W. J., Brown, M. W., McNitt, S. A., & Andrews, M. L. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.04.025 · Cited by 25
Arrhythmogenic and metabolic remodelling of failing human heart
Gloschat, C. R., Koppel, A. C., Aras, K. K., Brennan, J. A., Holzem, K. M., & Efimov, I. R. (2016) · The Journal of Physiology · doi:10.1113/jp271992 · Cited by 23
“Implantable cardioverter defibrillators are effective at preventing sudden cardiac death (Buxton et al. 1999; Glatter et al. 2006), to which HF patients are highly susceptible, but does nothing to reverse or slow disease progression.”
BackgroundSaldarriaga, C., Zannad, F. M., McMullan, C. J., Xing, A., Gates, D. F., Anstrom, K. J., Bonaca, M. P., Corda, S., Ezekowitz, J. A., Lam, C. S. P., et al. (2025) · European Journal of Heart Failure · doi:10.1002/ejhf.3598 · Cited by 24
Ventricular Ectopy in Patients With Left Ventricular Dysfunction: Should It Be Treated?
Chen, T., Koene, R. J., Benditt, D. G., & Lü, F. (2012) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2012.11.004 · Cited by 25
Labedi, M. R., Alharethi, R. A., Kfoury, A. G., Budge, D., Bruce, R., Rasmusson, B. Y., & Bunch, T. J. (2013) · ASAIO Journal · doi:10.1097/mat.0b013e318285fe93 · Cited by 24
HALL, B. W., Jeevanantham, V., Levine, E., Daubert, J. P., McNitt, S., Hall, F., Jeevanantham, V., Levine, E., Daubert, J. P., McNitt, S. A., et al. (2007) · PubMed · Cited by 24
Vandenberk, B., Robyns, T., Goovaerts, G., Soest, S. V., Floré, V., Garweg, C., Huffel, S. V., Ector, J., & Willems, R. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.02.131 · Cited by 24
Reliability and longevity of implantable defibrillators
Hauser, R. G., Casey, S. A., Gitter, C. B., Tang, C. Y., Abdelhadi, R. H., Gornick, C. C., Stanberry, L. I., & Sengupta, J. D. (2021) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-020-00920-w · Cited by 24
Ermiş, C., Zadeii, G., Zhu, A. X., Fabian, W., Collins, J., Lurie, K. G., Sakaguchi, S., & Benditt, D. G. (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2003.02590.x · Cited by 24
Longitudinal Study of Implantable Cardioverter-Defibrillators
Masoudi, F. A., Go, A. S., Magid, D. J., Cassidy‐Bushrow, A. E., Doris, J. M., Fiocchi, F., Garcia-Montilla, R. J., Glenn, K. A., Goldberg, R. J., Gupta, N., et al. (2012) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.112.965368 · Cited by 24
Saba, S., Ravipati, L. P., & Voigt, A. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02509.x · Cited by 24
Völler, H., Kamke, W., Klein, H., Block, M. S., Reibis, R. K., Treusch, S., Contzen, K., Wegscheider, K., & on behalf of the PreSCD II registry investigators (2010) · EP Europace · doi:10.1093/europace/euq426 · Cited by 24
Heart Rate Turbulence as Risk-Predictor after Myocardial Infarction
Zuern, C. S., Barthel, P., & Bauer, A. (2011) · Frontiers in Physiology · doi:10.3389/fphys.2011.00099 · Cited by 23
Ventricular Arrhythmias in Heart Failure Patients
Lo, R., & Hsia, H. H. (2008) · Cardiology Clinics · doi:10.1016/j.ccl.2008.03.009 · Cited by 23
Management of Postoperative Arrhythmias
Rho, R. W., Bridges, C. R., & Kocovic, D. Z. (2000) · Seminars in Thoracic and Cardiovascular Surgery · doi:10.1053/stcs.2000.21117 · Cited by 24
Rubenstein, J., Lee, D. C., Wu, E., Kadish, A. H., PASSMAN, R. S., Bello, D. B., & Goldberger, J. J. (2013) · Cardiology Journal · doi:10.5603/cj.2013.0011 · Cited by 24
Gandjour, A., Dipl-Ges-Ök, A. H., & Adarkwah, C. C. (2011) · Value in Health · doi:10.1016/j.jval.2011.02.1180 · Cited by 24
History of electrical therapy for the heart
Sutton, R., Fisher, J. D., Linde, C. M., & Benditt, D. G. (2007) · European Heart Journal Supplements · doi:10.1093/eurheartj/sum072 · Cited by 25
Self-citationSulimov, V. A., Андреевна, О. Е., & Tsaregorodtsev, D. A. (2012) · EP Europace · doi:10.1093/europace/eus238 · Cited by 24
Management Strategies When Implanted Cardioverter Defibrillator Leads Fail: Survey Findings
Xu, W., Moore, H. J., Karasik, P., Franz, M. R., Singh, S., & Fletcher, R. D. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02454.x · Cited by 24
A Comparison of ICD Implantations in the United States Versus Italy
GREENBERG, S. M., Epstein, A. E., Deering, T. F., Goldman, D. S., Ghidina, M., NEASON, C., & Proclemer, A. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00625.x · Cited by 24
García‐Morán, E. (2002) · European Heart Journal · doi:10.1053/euhj.2001.3073 · Cited by 24
“It has proven its efficacy in the secondary prevention of sudden death([3]) and also in the primary prevention of sudden death in specific subgroups([4,5]).”
BackgroundKornacewicz-Jach, Z., Kossuth, I., & Czechowska, M. (2006) · Menopause Review/Przegląd Menopauzalny · Cited by 24
Jordaens, L. J. L. M. (2001) · European Heart Journal · doi:10.1053/euhj.2000.2464 · Cited by 24
“Most recent studies, confirming data from the prethrombolytic era([37]), used invasive procedures (programmed electrical stimulation) to define high risk groups([9,10,19]).”
BackgroundResultPappone, C., Vicedomini, G., Augello, G., Mazzone, P., Nardi, S., & Rosanio, S. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)03341-6 · Cited by 24
Geographic Differences in Implantable Cardioverter Defibrillator Usage
Seidl, K., & Senges, J. (2002) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2002.tb01961.x · Cited by 24
Cardiac Arrhythmias in the Athlete
Link, M. S., Homoud, M. K., Wang, P. J., & Estes, N. A. M. (2001) · Cardiology in Review · doi:10.1097/00045415-200101000-00006 · Cited by 26
“Asymptomatic patients with CAD and left ventricular ejection fractions#35% may benefit from electrophysiologic testing (40, 41).”
BackgroundPathophysiology of Physiologic Cardiac Pacing
Kass, D. A. (2002) · JAMA · doi:10.1001/jama.288.24.3159 · Cited by 24
Bencardino, G., Monaco, A. D., Rio, T., Frontera, A., Santangeli, P., Leo, M., Pelargonio, G., Perna, F., Narducci, M. L., Gabrielli, F., et al. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12499 · Cited by 23
Defibrillator Implantation in Patients with Nonischemic Systolic Heart Failure
On, Y. K. (2017) · International Journal of Arrhythmia · doi:10.18501/arrhythmia.2017.008 · Cited by 23
Management of Post-Myocardial Infarction Patients with Left Ventricular Systolic Dysfunction
Gheorghiade, M., & Fonarow, G. C. (2007) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.08.010 · Cited by 23
Exner, D. V. (2009) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(09)71050-5 · Cited by 23
Rationale and design of the health economics evaluation registry for remote follow-up: TARIFF
Ricci, R. P., D’Onofrio, A., Padeletti, L., Sagone, A., Vicentini, A., Vincenti, A., Morichelli, L., Cavallaro, C., Ricciardi, W., Lombardi, L., et al. (2012) · EP Europace · doi:10.1093/europace/eus093 · Cited by 23
Feingold, B., Arora, G., Webber, S. A., & Smith, K. J. (2010) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2010.04.009 · Cited by 23
Crespo, E. M., Selzman, K. A., Kim, J., Steinhoff, J. P., & Sheahan, R. G. (2005) · The American Journal of the Medical Sciences · doi:10.1097/00000441-200505000-00005 · Cited by 23
de Werf, F. V., Bax, J. J., Betriu, A., Blomström‐Lundqvist, C., Crea, F., Falk, V., Filippatos, G. S., Fox, K. A. A., Huber, K., Kastrati, A., et al. (2009) · Rational Pharmacotherapy in Cardiology · doi:10.20996/1819-6446-2009-5-5-73-89 · Cited by 24
Marshall, P., Malecki-Ketchell, A., & Maclean, J. (2011) · European Journal of Cardiovascular Nursing · doi:10.1016/j.ejcnurse.2011.06.010 · Cited by 25
“11) Ethnicity 1 Caucasian 46 (98) 32 (97) 14 (100) 2 Black 1 (2) 1 (3) 0 Marital status 1 Married/partner 34 (72) 25 (76) 9 (65) 2 Single 6 (13) 3 (9) 3 (21) 3 Separated/divorced 5 (11) 4 (12) 1 (7) 4 Widow/er 2 (4) 1 (3) 1 (7) Social Support 1 Live with next of kin 40 (85) 28 (85) 12 (86) 2 Next of kin nearby 5 (11)…”
Sex Differences in Utilisation and Response to Implantable Device Therapy
Narasimha, D., & Curtis, A. B. (2015) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2015.04.02.129 · Cited by 23
Is Defibrillation Testing Necessary for Implantable Transvenous Defibrillators?
Russo, A. M., & Chung, M. K. (2014) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000371 · Cited by 23
Metadata
- Authors
- Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G.
- Affiliations
- Brown University (US)
- Duke University (US)
- Albert Einstein College of Medicine (US)
- Beth Israel Deaconess Medical Center (US)
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1999-12-16
- Volume
- 341
- Issue
- 25
- Pages
- 1882-1890
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2313547185
- Cited by
- 2,489
- References
- 34
- Citations by year
- 2026: 20 · 2025: 36 · 2024: 23 · 2023: 34 · 2022: 44 · 2021: 41 · 2020: 51 · 2019: 54 · 2018: 54 · 2017: 92 · 2016: 75 · 2015: 87 · 2014: 95 · 2013: 114 · 2012: 122
- FWCI
- 70.29
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5u01hl045726-06)
- National Heart, Lung, and Blood Institute (UO1HL45700, UO1-HL45726, U01HL045700)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- coronary artery disease, asymptomatic ventricular arrhythmia, implantable cardioverter-defibrillator, antiarrhythmic drugs, electrophysiologic testing, programmed electrical stimulation, cardiac arrest, all-cause mortality, left ventricular ejection fraction, ACE inhibitors, beta-blockers
- MeSH terms
- Aged, Anti-Arrhythmia Agents, Cardiac Pacing, Artificial, Coronary Disease, Electrophysiology, Female, Humans, Male, Middle Aged, Survival Analysis, Death, Sudden, Cardiac, Defibrillators, Implantable, Tachycardia, Ventricular
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review