The DOI matches its Crossref record, with a small difference in title or year; 34 of the 34 references it cites were found in a registry or an index.
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Open accessAbstract
BACKGROUND: Empirical antiarrhythmic therapy has not reduced mortality among patients with coronary artery disease and asymptomatic ventricular arrhythmias. Previous studies have suggested that antiarrhythmic therapy guided by electrophysiologic testing might reduce the risk of sudden death. METHODS: We conducted a randomized, controlled trial to test the hypothesis that electrophysiologically guided antiarrhythmic therapy would reduce the risk of sudden death among patients with coronary artery disease, a left ventricular ejection fraction of 40 percent or less, and asymptomatic, unsustained ventricular tachycardia. Patients in whom sustained ventricular tachyarrhythmias were induced by programmed stimulation were randomly assigned to receive either antiarrhythmic therapy, including drugs and implantable defibrillators, as indicated by the results of electrophysiologic testing, or no antiarrhythmic therapy. Angiotensin-converting-enzyme inhibitors and beta-adrenergic-blocking agents were administered if the patients could tolerate them. RESULTS: A total of 704 patients with inducible, sustained ventricular tachyarrhythmias were randomly assigned to treatment groups. Five-year Kaplan-Meier estimates of the incidence of the primary end point of cardiac arrest or death from arrhythmia were 25 percent among those receiving electrophysiologically guided therapy and 32 percent among the patients assigned to no antiarrhythmic therapy (relative risk, 0.73; 95 percent confidence interval, 0.53 to 0.99), representing a reduction in risk of 27 percent). The five-year estimates of overall mortality were 42 percent and 48 percent, respectively (relative risk, 0.80; 95 percent confidence interval, 0.64 to 1.01). The risk of cardiac arrest or death from arrhythmia among the patients who received treatment with defibrillators was significantly lower than that among the patients discharged without receiving defibrillator treatment (relative risk, 0.24; 95 percent confidence interval, 0.13 to 0.45; P<0.001). Neither the rate of cardiac arrest or death from arrhythmia nor the overall mortality rate was lower among the patients assigned to electrophysiologically guided therapy and treated with antiarrhythmic drugs than among the patients assigned to no antiarrhythmic therapy. CONCLUSIONS: Electrophysiologically guided antiarrhythmic therapy with implantable defibrillators, but not with antiarrhythmic drugs, reduces the risk of sudden death in high-risk patients with coronary disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Following the Multicenter Unsustained Tachycardia Trial (MUSTT) (Buxton et al., 1999), there is a role for AECG for NSVT detection in post-MI patients with LVEF 35%-40% as electrophysiologically guided ICD implantation improves survival”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Buxton et al., 1999
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“NSVT accompanied by inducibility of sustained VT during programmed ventricular stimulation was associated with an increased risk of SCD”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Buxton et al., 1999
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
The Statistical Analysis of Failure Time Data.
Aitkin, M. A., Kalbfleisch, J. D., & Prentice, R. L. (1981) · Biometrics · doi:10.2307/2530581 · Cited by 9,875
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
A Multiple Testing Procedure for Clinical Trials
O'Brien, P. C., & Fleming, T. R. (1979) · Biometrics · doi:10.2307/2530245 · Cited by 3,311
Mortality and Morbidity in Patients Receiving Encainide, Flecainide, or Placebo
Echt, D. S., Liebson, P. R., Mitchell, L. B., Peters, R. W., Obias-Manno, D., Barker, A. H., Arensberg, D., Baker, A., Friedman, L., Greene, H. L., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199103213241201 · Cited by 3,244
The AVID Investigators (1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,221
Discrete Sequential Boundaries for Clinical Trials
Lan, K. K. G., & DeMets, D. L. (1983) · Biometrika · doi:10.2307/2336502 · Cited by 2,310
Discrete sequential boundaries for clinical trials
GORDON LAN, K. K., & DEMETS, D. L. (1983) · Biometrika · doi:10.1093/biomet/70.3.659 · Cited by 2,310
Julian, D. G., CAMM, A. J., Frangin, G., Janse, M. J., Munoz, A., Pj, S., & Simon, P. (1997) · The Lancet · doi:10.1016/s0140-6736(96)09145-3 · Cited by 1,100
Research works printed but not linked: 1
- 10.2307/2281868 · DOI · Paper page
Cited by
Sorted by citations
Items 301–400 of 1,000
Hulleman, M., Berdowski, J., de Groot, J. R., van Dessel, P. F. H. M., Borleffs, C. J. W., Blom, M. T., Bardai, A., de Cock, C. C., Tan, H. L., Tijssen, J. G. P., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.089425 · Cited by 83
QRS Fragmentation and the Risk of Sudden Cardiac Death in MADIT II
brenyo, A. J., Pietrasik, G. M., Barsheshet, A., Huang, D. T.-C., Polonsky, B., McNitt, S. A., Moss, A. J., & Zaręba, W. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2012.02390.x · Cited by 83
Implantable cardioverter defibrillator (ICD) in children
Eicken, A., Kolb, C., Lange, S., Brodherr-Heberlein, S., Zrenner, B., Schreiber, C., & Hess, J. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2005.02.048 · Cited by 83
“, in patients at risk for but not having had a serious ventricular arrhythmia) [5–7] and for secondary prevention (after successful resuscitation from a life-threatening arrhythmia) [2–4].”
BackgroundMechanisms of Sudden Cardiac Death in Myocardial Infarction Survivors
Bunch, T. J., Hohnloser, S. H., & Gersh, B. J. (2007) · Circulation · doi:10.1161/circulationaha.106.683235 · Cited by 83
Barra, S., Providencia, R. A., Paiva, L., Heck, P., & Agarwal, S. (2014) · EP Europace · doi:10.1093/europace/euu296 · Cited by 83
“Average age of patients at the time of study enrolment was between 58–65 years in secondary prevention trials(3) – 5 and 58–66 years in the primary prevention trials.(1,2,6,7) Less than 25% of subjects included in the major clinical ICD trials are estimated to be .”
BackgroundBorleffs, C. J. W., Thijssen, J., de Bie, M. K., van Rees, J. B., van Welsenes, G. H., van Erven, L., Bax, J. J., Cannegieter, S. C., & Schalij, M. J. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02780.x · Cited by 82
Bauer, A., Guzik, P., Barthel, P., Schneider, R., Ulm, K., Watanabe, M., & Schmidt, G. P. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi101 · Cited by 82
Hauer, R. N. W. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2584 · Cited by 82
Parkash, R., Stevenson, W. G., Epstein, L. M., & Maisel, W. H. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.04.009 · Cited by 81
Zaman, S. J., Sivagangabalan, G., Narayan, A., Thiagalingam, A., Ross, D. L., & Kovoor, P. (2009) · Circulation · doi:10.1161/circulationaha.108.836791 · Cited by 81
Theuns, D. A. M. J., Rivero‐Ayerza, M., Boersma, E., & Jordaens, L. J. L. M. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.02.041 · Cited by 81
Cardiac contractility modulation: a novel approach for the treatment of heart failure
ABI‐SAMRA, F. M., & Gutterman, D. D. (2016) · Heart Failure Reviews · doi:10.1007/s10741-016-9571-6 · Cited by 84
Russo, A. M., Stamato, N. J., Lehmann, M. H., Hafley, G. E., Lee, K. L., Pieper, K. S., Buxton, A. E., & MUSTT Investigators (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.04050.x · Cited by 81
Self-citationSurvival in octogenarians receiving implantable defibrillators
Koplan, B. A., Epstein, L. M., Albert, C. M., & Stevenson, W. G. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.06.008 · Cited by 80
B-type natriuretic peptide is a major predictor of ventricular tachyarrhythmias
Levine, Y. C., Rosenberg, M. A., Mittleman, M. A., Samuel, M., Methachittiphan, N., Link, M. S., Josephson, M. E., & Buxton, A. E. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.04.024 · Cited by 80
Self-citationCurtis, A. B., Ellenbogen, K. A., Hammill, S. C., Hayes, D. L., REYNOLDS, D. W., Wilber, D. J., & CAIN, M. E. (2004) · Heart Rhythm · doi:10.1016/j.hrthm.2004.08.003 · Cited by 79
Effect of risk stratification on cost-effectiveness of the implantable cardioverter defibrillator
Owens, D. K., Sanders, G. D., Heidenreich, P. A., McDonald, K. M., & Hlatky, M. A. (2002) · American Heart Journal · doi:10.1067/mhj.2002.125501 · Cited by 80
Not Everyone With an Ejection Fraction ≤30% Should Receive an ICD
Buxton, A. E. (2005) · Circulation · doi:10.1161/01.cir.0000165057.88551.2c · Cited by 80
Self-citationSudden cardiac death in China: current status and future perspectives
Zhang, S. (2015) · EP Europace · doi:10.1093/europace/euv143 · Cited by 79
Prevalence and Incidence of Arrhythmias and Sudden Death in Heart Failure
Cleland, J. G. F., Chattopadhyay, S., Khand, A. U., Houghton, T., & Kaye, G. (2002) · Heart Failure Reviews · doi:10.1023/a:1020024122726 · Cited by 81
“The largest study to have addressed this issue so far, the MUSTT study, suggested that 2 and 5 year all-cause mortality of patients with LVSD subsequent to a myocardial infarction were no different in patients with and without inducible ventricular tachycardia, although there was a 25–30% increased risk of cardiac arr…”
BackgroundThomas, K. L., Al‐Khatib, S. M., Kelsey, R. C., Bush, H., Brosius, L., Velazquez, E. J., Peterson, E. D., & Gilliam, F. R. (2007) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2007.04.024 · Cited by 78
Clinical Management and Prevention of Sudden Cardiac Death
Yousuf, O. K., Chrispin, J., Tomaselli, G. F., & Berger, R. D. (2015) · Circulation Research · doi:10.1161/circresaha.116.304555 · Cited by 83
Short-Term Exposure to Air Pollution and Cardiac Arrhythmia: A Meta-Analysis and Systematic Review
Song, X., Liu, Y., Hu, Y., Zhao, X., Tian, J., Ding, G., & Wang, S. (2016) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph13070642 · Cited by 81
Buxton, A. E., Sweeney, M. O., Wathen, M. S., Josephson, M. E., Otterness, M. F., Hogan-Miller, E., Stark, A. J., & DeGroot, P. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.060 · Cited by 77
Self-citationProietti, R., Labos, C., Davis, M., Thanassoulis, G., Santangeli, P., Russo, V., Biase, L. D., Roux, J.-F., Verma, A., Natale, A., et al. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2014.11.023 · Cited by 77
Isaksen, K., Morken, I. M., Munk, P. S., & Larsen, A. I. (2011) · European Journal of Preventive Cardiology · doi:10.1177/1741826711414624 · Cited by 77
Providencia, R. A., Kramer, D. B., Pimenta, D., Babu, G. G., Hatfield, L. A., Ioannou, A., Novak, J., Hauser, R. G., & Lambiase, P. D. (2015) · Journal of the American Heart Association · doi:10.1161/jaha.115.002418 · Cited by 77
Haugaa, K. H., Tilz, R. R., Bovéda, S., Dobreanu, D., Sciaraffia, E., Mansourati, J., Papiashvili, G., & Dagres, N. (2017) · EP Europace · doi:10.1093/europace/eux089 · Cited by 76
“In patients with ischaemic heart disease, ICD for primary prevention has been shown to be associated with substantial reductions in the rate of sudden cardiac death in several trials.(7,9,10) This EP wire showed that the majority of centres followed the Class I, level of evidence A indications for primary prevention I…”
BackgroundVentricular arrhythmias. Ventricular tachycardias and sudden cardiac death. 2020 Clinical guidelines
Lebedev, D. S., Mikhaylov, E. N., Neminuschiy, N. M., Golukhova, E. Z., Babokin, V. E., Bereznitskaya, V. V., Vasichkina, E. S., Garkina, S. V., Sp, G., Davtyan, K. V., et al. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4600 · Cited by 87
Yap, Y. G., Duong, T., Bland, M., Malik, M., Torp-Pedersen, C. T., Køber, L., Connolly, S. J., Marchant, B., & Camm, A. J. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi268 · Cited by 76
Cygankiewicz, I., Gillespie, J. A., Zaręba, W., Brown, M. W., Goldenberg, I., Klein, H., McNitt, S. A., Polonsky, S., Andrews, M. L., Dwyer, E. M., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.12.023 · Cited by 76
Defibrillation for Ventricular Fibrillation
Nichol, G., Sayre, M. R., Guerra, F., & Poole, J. E. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.07.778 · Cited by 76
Bello, D. B., Einhorn, A., Kaushal, R., Kenchaiah, S., Raney, A. R., Fieno, D. S., Narula, J., Goldberger, J. J., Shivkumar, K., Subacius, H. P., et al. (2010) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2010.03.031 · Cited by 75
“Patients with CAD and low ejection fractions are candidates for therapy with an implantable cardioverterdefibrillator to prevent sudden cardiac death [2–6].”
BackgroundGoldstein, N. E., & Lynn, J. (2006) · Perspectives in biology and medicine · doi:10.1353/pbm.2006.0008 · Cited by 75
Epstein, A. E., Baessler, C. A., Curtis, A. B., Estes, N. A. M., Gersh, B. J., Grubb, B. P., & Mitchell, L. B. (2007) · Circulation · doi:10.1161/circulationaha.106.180203 · Cited by 75
Predictors of VT/VF-occurrence in ICD patients: results from the PROFIT-Study
Klein, G. G., Lissel, C., Fuchs, A.-C., Gardiwal, A., Oswald, H., deSousa, M., Pichlmaier, A. M., Lichtinghagen, R., Geerlings, H., Lippolt, P., et al. (2006) · EP Europace · doi:10.1093/europace/eul082 · Cited by 75
Modern Management of Acute Myocardial Infarction
Yang, E. H., Brilakis, E. S., Reeder, G. S., & Gersh, B. J. (2006) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2006.08.004 · Cited by 76
Ripplinger, C. M., Lou, Q., Li, W., Hadley, J. L., & Efimov, I. R. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.09.019 · Cited by 74
Colquitt, J. L., Mendes, D., Clegg, A. J., Harris, P., Cooper, K., Picot, J., & Bryant, J. (2014) · Health Technology Assessment · doi:10.3310/hta18560 · Cited by 75
“001).(146) The overall mortality rate at 5 years was 24% among patients who received a defibrillator and 55% among those who did not.”
BackgroundHauser, R. G., Hayes, D. L., Epstein, A. E., Cannom, D. S., Vlay, S. C., SONG, S. L., & Tyers, G. F. O. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.02.011 · Cited by 74
The effects of age on quality of life in implantable cardioverter defibrillator recipients
Hamilton, G. A., & Carroll, D. L. (2004) · Journal of Clinical Nursing · doi:10.1046/j.1365-2702.2003.00846.x · Cited by 74
Guimar�es, J. I., Mesquita, E. T., Bocchi, E. A., Vilas-Boas, F., Montera, M. W., Moreira, M. C. V., Batlouni, M., Barretto, A. C. P., Neto, C. D., Mady, C., et al. (2002) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2002001800001 · Cited by 71
Robin, J. C., Weinberg, K. M., Tiongson, J. E., Carnethon, M. R., Reddy, M., Ciaccio, C. E., Quadrini, M., Hsu, J. C., Fan, J. S., Choi, P., et al. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.06.013 · Cited by 74
Lee, K. L., Hafley, G. E., Fisher, J. D., Gold, M. R., Prystowsky, E. N., Talajic, M. R., Josephson, M. E., Packer, D. L., & Buxton, A. E. (2002) · Circulation · doi:10.1161/01.cir.0000021920.73149.c3 · Cited by 74
Self-citationSafety and Efficacy of the Subcutaneous Implantable Defibrillator
Lewis, G. F., & Gold, M. R. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.11.026 · Cited by 73
Pacemaker and ICD leads: Strategies for long-term management
Borek, P., & Wilkoff, B. L. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9249-7 · Cited by 75
Life-Years Gained From Defibrillator Implantation
Salukhe, T. V., Dimopoulos, K., Sutton, R., Coats, A. J. S., Piepoli, M. F., & Francis, D. P. (2004) · Circulation · doi:10.1161/01.cir.0000125522.10053.29 · Cited by 73
Effect of β-Blocking Therapy on Outcome in the Multicenter UnSustained Tachycardia Trial (MUSTT)
Ellison, K., Hafley, G. E., Hickey, K. T., Kellen, J., Coromilas, J., Steín, K. M., Lee, K. L., & Buxton, A. E. (2002) · Circulation · doi:10.1161/01.cir.0000038499.22687.39 · Cited by 73
Self-citationKalahasti, V., Nambi, V., Martin, D. O., LAM, C. T., Yamada, D., Wilkoff, B. L., Niebauer, M. J., Jaeger, F. J., TCHOU, P. J., & Chung, M. K. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(03)00886-5 · Cited by 71
de Sousa, M. R., Morillo, C. A., Rabelo, F. T., Filho, A. M. N., & Ribeiro, A. L. P. (2008) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2008.07.002 · Cited by 72
Sears, S. F., Serber, E. R., Lewis, T. S., Walker, R. L., Conners, N., Lee, J. T., Curtis, A. B., & Conti, J. B. (2004) · Journal of Cardiopulmonary Rehabilitation · doi:10.1097/00008483-200409000-00008 · Cited by 71
Marijon, É., Garcia, R., Narayanan, K., Karam, N., & Jouven, X. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab903 · Cited by 71
Groh, W. J., Bhakta, D., Tomaselli, G. F., Aleong, R. G., Teixeira, R. A., Amato, A. A., Asirvatham, S. J., Cha, Y., Corrado, D., Duboc, D., et al. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2022.04.022 · Cited by 72
Rosenthal, T. M., Stahls, P. F., ABI‐SAMRA, F. M., Bernard, M. L., Khatib, S., Polin, G. M., Xue, J. Q., & Morin, D. P. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.04.035 · Cited by 71
“Several prospective, randomized, controlled trials have shown that implantable cardioverterdefibrillator (ICD) placement in these patients reduces mortality.((2-5)) However, in a substantial proportion of patients who receive an ICD based on reduced LVEF, the device never delivers therapy over its lifetime.”
BackgroundEvolution of Left Ventricular Ejection Fraction After Acute Myocardial Infarction
Sjöblom, J., Muhrbeck, J., Witt, N., Alam, M., & Frykman, V. (2014) · Circulation · doi:10.1161/circulationaha.114.009924 · Cited by 71
Amin, M. S., Fox, A. D., Kalahasty, G., Shepard, R. K., Wood, M. A., & Ellenbogen, K. A. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01258.x · Cited by 71
Santini, M., Ricci, R. P., Lunati, M., Landolina, M., Perego, G. B., Marzegalli, M., Schirru, M., Belvito, C., Brambilla, R., Guenzati, G., et al. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9321-3 · Cited by 71
Buxton, M. J., Caine, N., Chase, D. P., Connelly, D. T., Grace, A. A., Jackson, C., Parkes, J., & Sharples, L. D. (2006) · Health Technology Assessment · doi:10.3310/hta10270 · Cited by 71
Liu, P. J., Arnold, M., Belenkie, I., Howlett, J. G., Huckell, V. F., Ignazewski, A., LeBlanc, M. H., McKelvie, R. S., Niznick, J., Parker, J. D., et al. (2001) · PubMed · Cited by 71
Al‐Khatib, S. M., Sanders, G. D., Mark, D. B., Lee, K. L., Bardy, G. H., Bigger, J. T., Buxton, A. E., Connolly, S. J., Kadish, A. H., Moss, A. J., et al. (2005) · American Heart Journal · doi:10.1016/j.ahj.2005.02.005 · Cited by 69
Self-citationGuías de práctica clínica de la Sociedad Española de Cardiología en arritmias cardíacas
Garrote, J. A., Huerta, E. M., Moreno, O. M., Peinado, R., Álvarez, L. P., Granell, R. R., & Viñolas, X. (2001) · Revista Española de Cardiología · doi:10.1016/s0300-8932(01)76313-0 · Cited by 71
Caldeira, D., David, C., & Sampaio, C. (2012) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2011.11.005 · Cited by 70
Liu, P. X., Arnold, J. M. O., Belenkie, I., Demers, C., Dorian, P., Giannetti, N., Haddad, H. A., Howlett, J. G., Ignazewski, A., Jong, P., et al. (2003) · PubMed · Cited by 69
Satake, H., Fukuda, K., Sakata, Y., Miyata, S., Nakano, M., Kondo, M., Hasebe, Y., Segawa, M., Shimokawa, H., & on behalf of the CHART-2 Investigators (2014) · Circulation Journal · doi:10.1253/circj.cj-14-0925 · Cited by 69
A computer modeling tool for comparing novel ICD electrode orientations in children and adults
Jolley, M. A., Stinstra, J. G., Pieper, S., MacLeod, R., Brooks, D. H., Cecchin, F., & Triedman, J. K. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.01.018 · Cited by 69
Rhee, E. K., Canter, C. E., Basile, S., Webber, S. A., & Naftel, D. C. (2007) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2007.02.005 · Cited by 69
Optimal Programming of Implantable Cardiac-Defibrillators
Madhavan, M., & Friedman, P. A. (2013) · Circulation · doi:10.1161/circulationaha.112.000542 · Cited by 69
The Defibrillator in Acute Myocardial Infarction Trial (DINAMIT): Study protocol
Hohnloser, S. H., Connolly, S. J., Kück, K., Dorian, P., Fain, E. S., Hampton, J., Hatala, R., Pauly, A. C., Roberts, R. S., Themeles, E., et al. (2000) · American Heart Journal · doi:10.1067/mhj.2000.110088 · Cited by 69
Enfermedad cardiovascular en el anciano
Jackson, C. F., & WENGER, N. K. (2011) · Revista Española de Cardiología · doi:10.1016/j.recesp.2011.05.001 · Cited by 72
Morin, D. P., Saad, M., Shams, O. F., Owen, J. S., Xue, J. Q., ABI‐SAMRA, F. M., Khatib, S., Nelson-Twakor, O. S., & Milani, R. V. (2012) · EP Europace · doi:10.1093/europace/eur426 · Cited by 68
Sood, N., Ruwald, A., Solomon, S. D., Daubert, J. P., McNitt, S. A., Polonsky, B., Jøns, C., Clyne, C. A., Zaręba, W., & Moss, A. J. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht451 · Cited by 68
Morin, D. P., Oikarinen, L., Viitasalo, M. T., Toivonen, L., Nieminen, M. S., Kjeldsen, S., Dahlöf, B., John, M., Devereux, R. B., & Okin, P. M. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp321 · Cited by 67
Alsheikh-Ali, A. A. A., HOMER, M., Maddukuri, P. V., Kalsmith, B. M., Estes, N. A. M., & Link, M. S. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01111.x · Cited by 67
Chan, P. S., Steín, K. M., Chow, T., Fendrick, M., Bigger, J. T., & Vijan, S. S. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.02.051 · Cited by 67
Furushima, H., Chinushi, M., Sugiura, H., Komura, S., Tanabe, Y., Watanabe, H., Washizuka, T., & Aizawa, Y. (2006) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2005.08.005 · Cited by 68
“Although the effectiveness of catheter ablation for VT has improved [17-20], ICDs have been shown to be highly effective in treating ventricular arrhythmias in patients with coronary heart disease [21,22].”
BackgroundTang, A., Ross, H. J., Simpson, C. S., Mitchell, L. B., Dorian, P., Goeree, R. A., Hoffmaster, B., Arnold, M., & Talajic, M. R. (2005) · PubMed · Cited by 65
Amiodarone and Optic Neuropathy: The Heart of the Matter
Murphy, M. A., & Murphy, J. F. (2005) · Journal of Neuro-Ophthalmology · doi:10.1097/01.wno.0000177290.09649.38 · Cited by 67
“Implantable cardioverter defibrillators (ICD) are the first-line therapy for both primary and secondary prevention (7,8).”
BackgroundExpanding Indications for Implantable Cardiac Defibrillators
Bigger, J. T. (2002) · New England Journal of Medicine · doi:10.1056/nejme020011 · Cited by 67
Sex-Specific Differences in Heart Failure: Pathophysiology, Risk Factors, Management, and Outcomes
Sullivan, K., Doumouras, B. S., Santema, B. T., Walsh, M. N., Douglas, P. S., Voors, A. A., & Spall, H. G. C. V. (2020) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2020.12.025 · Cited by 65
de Werf, F. V., Bax, J. J., Betriu, A., Blomström‐Lundqvist, C., Crea, F., Falk, V., Filippatos, G. S., Fox, K. A. A., Huber, K., Kastrati, A., et al. (2009) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(09)71559-2 · Cited by 65
Albert, C. M., Quigg, R. J., Saba, S., Estes, N. A. M., Schaecter, A., Subacius, H. P., Howard, A., Levine, J. H., & Kadish, A. H. (2008) · American Heart Journal · doi:10.1016/j.ahj.2008.02.026 · Cited by 66
Meier, P., Vogt, P. R., & Blanc, E. (2001) · The Nephron journals/Nephron journals · doi:10.1159/000045917 · Cited by 65
“worse than in any other high-risk category, including diabetes mellitus. Calcifying atherosclerotic coronary lesions are common in the HD patient; their presence is related not only to lipid concentrations, but also to the calcium × phosphorus product and probably other factors which are still poorly understood. Thus,…”
BackgroundThe effects of omega-3 polyunsaturated fatty acids on cardiac rhythm: A critical reassessment
Billman, G. E. (2013) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2013.05.011 · Cited by 69
“Implantable cardioverter defibrillators (ICDs) have been shown to reduce cardiac mortality, providing a better protection from sudden death than current pharmacological therapy in certain high-risk patient populations (Buxton et al., 1999; Connelly et al., 2000; Al-Khatib et al., 2013).”
BackgroundSherazi, S., Daubert, J. P., Block, R., Jeevanantham, V., Abdelgadir, K., DiSalle, M. R., Haley, J. M., & Shah, A. H. (2008) · Mayo Clinic Proceedings · doi:10.4065/83.10.1139 · Cited by 66
Maury, P., Baratto, F., Zeppenfeld, K., Klein, G. J., Delacrétaz, E., Sacher, F., Pruvot, E. J., Brigadeau, F., Rollin, A., Andronache, M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu040 · Cited by 70
Providencia, R. A., Marijon, É., Lambiase, P. D., Bouzeman, A., Defaye, P., Klug, D., Amet, D., Perier, M., Gras, D., Algalarrondo, V., et al. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.115.002756 · Cited by 65
Foo, D. C. G., WALKER, B. D., Kuchar, D. L., Thorburn, C. W., Tay, A., Hayward, C., Macdonald, P. S., KEOGH, A. M., Kotlyar, E., Spratt, P., et al. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02403.x · Cited by 64
Rashba, E. J., Osman, A., MacMurdy, K., KIRK, M. M., Sarang, S., Peters, R. W., Shorofsky, S. R., & Gold, M. R. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03428.x · Cited by 64
Tereshchenko, L. G., Faddis, M. N., Fetics, B. J., Zelik, K. E., Efimov, I. R., & Berger, R. D. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.06.004 · Cited by 64
Li, W., Ripplinger, C. M., Lou, Q., & Efimov, I. R. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.03.015 · Cited by 64
Weeke, P. E., Johansen, J. B., Jørgensen, O. D., Nielsen, J. C., Møller, M. B., Videbæk, R., Hojgaard, M. V., Riahi, S., & Jacobsen, P. K. (2013) · EP Europace · doi:10.1093/europace/eut017 · Cited by 65
Rashba, E. J., Osman, A., MacMurdy, K., KIRK, M. M., Sarang, S., Peters, R. W., Shorofsky, S. R., & Gold, M. R. (2002) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2002.00845.x · Cited by 64
Year-long upregulation of connexin43 in rabbit hearts by heavy ion irradiation
Amino, M., Yoshioka, K., Fujibayashi, D., Hashida, T., Furusawa, Y., Zaręba, W., Ikari, Y., Tanaka, E., Mori, H., Inokuchi, S., et al. (2010) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00160.2009 · Cited by 63
Zaman, S. J., Narayan, A., Thiagalingam, A., Sivagangabalan, G., Thomas, S. P., Ross, D. L., & Kovoor, P. (2013) · Circulation · doi:10.1161/circulationaha.113.005146 · Cited by 63
“8,9 Inducible ventricular tachycardia (VT) at electrophysiological study (EPS) demonstrates the presence of a substrate for re-entrant tachyarrhythmia and consistently predicts arrhythmia in observational and randomised studies.(10-16) The potential utility of EPS to guide early ICD implantation post-MI has been demon…”
BackgroundMethodFREEDBERG, N. A., Hill, J. N., Fogel, R. I., & Prystowsky, E. N. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01226-8 · Cited by 63
Self-citationPacing therapies in congestive heart failure II study
Stellbrink, C., Auricchio, A., Butter, C., Sack, S., Vogt, J., Böcker, D., Block, M. S., Kirkels, H., & Misier, A. R. R. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01298-4 · Cited by 63
Peinado, R., Arenal, Á., Arribas, F., Torrecilla, E. G., Álvarez, M., Ormaetxe, J. M., & Pérez‐Castellano, N. (2005) · Revista Española de Cardiología · doi:10.1016/s0300-8932(05)74074-4 · Cited by 63
The Efficacy of Implantable Cardioverter-Defibrillators in Heart Transplant Recipients
Tsai, V., Cooper, J. M., Garan, H., Natale, A., Ptaszek, L. M., Ellinor, P. T., Hickey, K. T., Downey, R. A., Zei, P. C., Hsia, H. H., et al. (2009) · Circulation Heart Failure · doi:10.1161/circheartfailure.108.814525 · Cited by 62
JCS/JHRS 2022 Guideline on Diagnosis and Risk Assessment of Arrhythmia
Takase, B., Ikeda, T., Shimizu, W., Abe, H., Aiba, T., Chinushi, M., Koba, S., KUSANO, K. F., Niwano, S., Takahashi, N., et al. (2023) · Circulation Journal · doi:10.1253/circj.cj-22-0827 · Cited by 68
Proclemer, A., Ghidina, M., Gregori, D., Facchin, D., Rebellato, L., Fioretti, P., & Brignole, M. (2008) · EP Europace · doi:10.1093/europace/eun370 · Cited by 61
Metadata
- Authors
- Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G.
- Affiliations
- Brown University (US)
- Duke University (US)
- Albert Einstein College of Medicine (US)
- Beth Israel Deaconess Medical Center (US)
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1999-12-16
- Volume
- 341
- Issue
- 25
- Pages
- 1882-1890
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2313547185
- Cited by
- 2,489
- References
- 34
- Citations by year
- 2026: 20 · 2025: 36 · 2024: 23 · 2023: 34 · 2022: 44 · 2021: 41 · 2020: 51 · 2019: 54 · 2018: 54 · 2017: 92 · 2016: 75 · 2015: 87 · 2014: 95 · 2013: 114 · 2012: 122
- FWCI
- 70.29
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5u01hl045726-06)
- National Heart, Lung, and Blood Institute (UO1HL45700, UO1-HL45726, U01HL045700)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- coronary artery disease, asymptomatic ventricular arrhythmia, implantable cardioverter-defibrillator, antiarrhythmic drugs, electrophysiologic testing, programmed electrical stimulation, cardiac arrest, all-cause mortality, left ventricular ejection fraction, ACE inhibitors, beta-blockers
- MeSH terms
- Aged, Anti-Arrhythmia Agents, Cardiac Pacing, Artificial, Coronary Disease, Electrophysiology, Female, Humans, Male, Middle Aged, Survival Analysis, Death, Sudden, Cardiac, Defibrillators, Implantable, Tachycardia, Ventricular
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review