Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 731

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Low-Dose Nitric Oxide Therapy for Persistent Pulmonary Hypertension of the Newborn

Open access
Clark, Reese H., Kueser, Thomas J., Walker, Marshall W., Southgate, W. Michael, Huckaby, Jeryl L., Perez, Jose A., Roy, Beverly J., Keszler, Martin, Kinsella, John P.·2000·New England Journal of Medicine

Abstract

BACKGROUND: Inhaled nitric oxide improves gas exchange in neonates, but the efficacy of low-dose inhaled nitric oxide in reducing the need for extracorporeal membrane oxygenation has not been established. METHODS: We conducted a clinical trial to determine whether low-dose inhaled nitric oxide would reduce the use of extracorporeal membrane oxygenation in neonates with pulmonary hypertension who were born after 34 weeks' gestation, were 4 days old or younger, required assisted ventilation, and had hypoxemic respiratory failure as defined by an oxygenation index of 25 or higher. The neonates who received nitric oxide were treated with 20 ppm for a maximum of 24 hours, followed by 5 ppm for no more than 96 hours. The primary end point of the study was the use of extracorporeal membrane oxygenation. RESULTS: Of 248 neonates enrolled, 126 were randomly assigned to the nitric oxide group and 122 to the control group. Extracorporeal membrane oxygenation was used in 78 neonates in the control group (64 percent) and in 48 neonates in the nitric oxide group (38 percent) (P=0.001). The 30-day mortality rate in the two groups was similar (8 percent in the control group and 7 percent in the nitric oxide group). Chronic lung disease developed less often in neonates treated with nitric oxide than in those in the control group (7 percent vs. 20 percent, P=0.02). The efficacy of nitric oxide was independent of the base-line oxygenation index and the primary pulmonary diagnosis. CONCLUSIONS: Inhaled nitric oxide reduces the extent to which extracorporeal membrane oxygenation is needed in neonates with hypoxemic respiratory failure and pulmonary hypertension.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm200002173420704

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 731

Metadata

Authors
Clark, R. H., Kueser, T. J., Walker, M. W., Southgate, W. M., Huckaby, J. L., Perez, J. A., Roy, B. J., Keszler, M., & Kinsella, J. P.
Venue
New England Journal of Medicine
Published
2000-02-17
Volume
342
Issue
7
Pages
469-474
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2340008871
Cited by
731
References
22
FWCI
32.62
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low-Dose Nitric Oxide Therapy for Persistent Pulmonary Hypertension of the Newborn. https://app.cochat.ai/papers/10.1056/nejm200002173420704
The paper
Clark, R. H., Kueser, T. J., Walker, M. W., Southgate, W. M., Huckaby, J. L., Perez, J. A., Roy, B. J., Keszler, M., & Kinsella, J. P. (2000). Low-Dose Nitric Oxide Therapy for Persistent Pulmonary Hypertension of the Newborn. New England Journal of Medicine. https://doi.org/10.1056/nejm200002173420704

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.