Culmination of an era in research on the acute respiratory distress syndrome.
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The acute respiratory distress syndrome is a form of noncardiogenic pulmonary edema that results from acute damage to the alveoli. Most patients with this syndrome will die if they do not receive supplemental oxygen and assisted ventilation. By reversing life-threatening hypoxemia and alleviating the work of breathing, mechanical ventilation buys time for the lungs to heal. Mechanical ventilation can also cause lung damage by several mechanisms, including alveolar rupture and alveolar hemorrhage, especially when high airway pressures are used for ventilation.Initially, the diffuse shadows seen on chest x-ray films in patients with the acute respiratory distress syndrome led clinicians . . .
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome.
Amato, M. B. P., Barbas, C. S. V., Medeiros, D. M., Magaldi, R. B., Schettino, G. P., Lorenzi-Filho, G., Kairalla, R. A., Deheinzelin, D., Munoz, C., Oliveira, R., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380602 · Cited by 3,654
Hickling, K. G., Henderson, S. J., & Jackson, R. (1990) · Intensive Care Medicine · doi:10.1007/bf01735174 · Cited by 933
Stewart, T. E., Meade, M. O., Cook, D. J., Granton, J. T., Hodder, R. V., Lapinsky, S. E., Mazer, C. D., McLean, R. F., Rogovein, T. S., Schouten, B. D., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380603 · Cited by 888
BROCHARD, L., ROUDOT-THORAVAL, F., ROUPIE, E., DELCLAUX, C., CHASTRE, J., FERNANDEZ-MONDÉJAR, E., CLÉMENTI, E., MANCEBO, J., FACTOR, P., MATAMIS, D., et al. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.6.9801044 · Cited by 800
Self-citationBrower, R. G., Shanholtz, C. B., Fessler, H. E., Shade, D. M., White, P., Wiener, C. M., Teeter, J. G., Dodd-o, J. M., Almog, Y., & Piantadosi, S. (1999) · Critical Care Medicine · doi:10.1097/00003246-199908000-00015 · Cited by 575
Total Respiratory Pressure-Volume Curves in the Adult Respiratory Distress Syndrome
Matamis, D., Lemaire, F., Harf, A., Brun-Buisson, C., Ansquer, J. C., & Atlan, G. (1984) · Chest · doi:10.1378/chest.86.1.58 · Cited by 475
Adult respiratory distress syndrome profiles by computed tomography
Gattinoni, L., Presenti, A., Torresin, A., Baglioni, S., Rivolta, M., Rossi, F., Scarani, F., Marcolin, R., & Cappelletti, G. (1986) · Journal of Thoracic Imaging · doi:10.1097/00005382-198607000-00005 · Cited by 297
Tobin, M. J. (1994) · New England Journal of Medicine · doi:10.1056/nejm199404143301507 · Cited by 262
Self-citationRichecoeur, J. R., Lü, Q., Vieira, S. R. R., Puybasset, L., Kalfon, P., Coriat, P., & Rouby, J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.1.9809006 · Cited by 89
Research works printed but not linked: 1
- 10.1056/NEJM200005043421801 · DOI · Paper page
Cited by
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
The Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
Dellinger, R. P., Levy, M. M., Carlet, J. M., Bion, J., Parker, M. M., Jaeschke, R., Reinhart, K., Angus, D. C., Brun-Buisson, C., Beale, R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-007-0934-2 · Cited by 6,772
Surviving Sepsis Campaign: International guidelines for management of sepsis and septic shock: 2016.
Rhodes, A., Evans, L. E., Alhazzani, W., Levy, M. M., Antonelli, M., Ferrer, R., Kumar, A., Sevransky, J. E., Sprung, C. L., Nunnally, M. E., et al. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4683-6 · Cited by 6,621
“Some clinicians believe it may be safe to ventilate with tidal volumes >6 mL/kg PBW as long as plateau pressure can be maintained ≤30 cmH2O [355, 356].”
BackgroundSurviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021
Evans, L., Rhodes, A., Alhazzani, W., Antonelli, M., Coopersmith, C. M., French, C., Machado, F. R., Mcintyre, L., Ostermann, M., Prescott, H. C., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06506-y · Cited by 5,082
Surviving Sepsis Campaign: International guidelines for management of sepsis and septic shock: 2016.
Rhodes, A., Evans, L. E., Alhazzani, W., Levy, M. M., Antonelli, M., Ferrer, R., Kumar, A., Sevransky, J. E., Sprung, C. L., Nunnally, M. E., et al. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002255 · Cited by 3,652
Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock 2021.
Evans, L., Rhodes, A., Alhazzani, W., Antonelli, M., Coopersmith, C. M., French, C., Machado, F. R., Mcintyre, L., Ostermann, M., Prescott, H. C., et al. (2021) · Critical Care Medicine · doi:10.1097/ccm.0000000000005337 · Cited by 2,935
Esteban, A. (2002) · JAMA · doi:10.1001/jama.287.3.345 · Cited by 1,779
Alhazzani, W., Møller, M. H., Arabi, Y. M., Loeb, M., Gong, M. N., Fan, E., Oczkowski, S., Levy, M. M., Derde, L., Dzierba, A., et al. (2020) · Critical Care Medicine · doi:10.1097/ccm.0000000000004363 · Cited by 1,565
Mercat, A., Richard, J.-C. M., Vielle, B., Jaber, S., Osman, D., Diehl, J.-L., Lefrant, J.-Y., Prat, G., Richecoeur, J., Nieszkowska, A., et al. (2008) · JAMA · doi:10.1001/jama.299.6.646 · Cited by 1,344
Acute lung injury and the acute respiratory distress syndrome: a clinical review
Wheeler, A. P., & Bernard, G. R. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60604-7 · Cited by 904
Tidal Hyperinflation during Low Tidal Volume Ventilation in Acute Respiratory Distress Syndrome
Terragni, P. P., Rosboch, G., Tealdi, A., Corno, E., Menaldo, E., Davini, O., Gandini, G., Herrmann, P., Mascia, L., Quintel, M., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200607-915oc · Cited by 820
Gajic, O., Dara, S. I., Mendez, J. L., Adesanya, A. O., Festic, E., Caples, S. M., Rana, R., St. Sauver, J. L., Lymp, J. F., Afessa, B., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000133019.52531.30 · Cited by 739
“Although lung-protective mechanical ventilation with small tidal volumes is becoming the standard of care for patients with ALI (18, 19), the efficacy of low-volume ventilation in patients without ALI has not been established.”
BackgroundDerdak, S., Mehta, S., Stewart, T. E., Smith, T., Rogers, M., Buchman, T. G., Carlin, B., Lowson, S., Granton, J., & Respirator, T. M. O. V. F. A. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2108052 · Cited by 624
“In the future, HFOV should be compared with the current “gold-standard” CV strategy such as the low tidal volume strategy used in the ARDS Network trial (42).”
MethodTidal Volume Reduction in Patients with Acute Lung Injury When Plateau Pressures Are Not High
Hager, D. N., Krishnan, J. A., Hayden, D. L., & Brower, R. G. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200501-048cp · Cited by 509
&NA; (2001) · Survey of Anesthesiology · doi:10.1097/00132586-200102000-00017 · Cited by 453
Advances in Mechanical Ventilation
Tobin, M. J. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106283442606 · Cited by 475
Self-citationInvited Review: Mechanisms of ventilator-induced lung injury: a perspective
Dos Santos, C. C., & Slutsky, A. S. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.4.1645 · Cited by 458
“The trial was stopped when an interim analysis revealed that the lower tidal volume group had a mortality that was 22% lower than the higher tidal volume group ( 63 ).”
The systemic inflammatory response syndrome
Meeran, H., & Messent, M. (2001) · Trauma · doi:10.1177/146040860100300203 · Cited by 425
“A degree of arterial hypoxaemia is also tolerated, typically a pO2 of 7–10 kPa is acceptable, as this helps limit inspired oxygen concentration and tidal volume (Tobin, 2000).”
BackgroundEichacker, P. Q., Gerstenberger, E. P., Banks, S. M., Cui, X., & Natanson, C. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200208-956oc · Cited by 423
High Tidal Volume and Positive Fluid Balance Are Associated With Worse Outcome in Acute Lung Injury
Sakr, Y., Vincent, J.-L., Reinhart, K., Groeneveld, J., Michalopoulos, A., Sprung, C. L., Artigas, A., & Ranieri, V. M. (2005) · Chest · doi:10.1378/chest.128.5.3098 · Cited by 405
Catastrophic Antiphospholipid Syndrome: Clues to the Pathogenesis from a Series of 80 Patients
ASHERSON, R. A., CERVERA, R., PIETTE, J.-C., SHOENFELD, Y., ESPINOSA, G., PETRI, M. A., LIM, E., LAU, T. C., GURJAL, A., JEDRYKA-GÓRAL, A., et al. (2001) · Medicine · doi:10.1097/00005792-200111000-00002 · Cited by 388
“It is a form of non-cardiogenic pulmonary edema that results from acute damage to the alveoli (26, 67).”
BackgroundMechanical Ventilation: State of the Art
Pham, T., Brochard, L. J., & Slutsky, A. S. (2017) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2017.05.004 · Cited by 377
“It took years of research to realize that high Vts, despite having favorable effects on oxygenation, were harmful for the lungs and increased mortality.(92) Current recommendations for setting Vt are based on predicted body weight (PBW) and not actual body weight because (normal) lung size scales with PBW.”
BackgroundPhysical and biological triggers of ventilator-induced lung injury and its prevention
Gattinoni, L., Carlesso, E., Cadringher, P., Valenza, F., Vagginelli, F., & Chiumello, D. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00021303 · Cited by 329
Incidence, clinical course, and outcome in 217 patients with acute respiratory distress syndrome
Estenssoro, E., Dubin, A., Laffaire, E., Canales, H., Sáenz, G., Moseinco, M., Pozo, M., Gómez, A., Baredes, N., Jannello, G., et al. (2002) · Critical Care Medicine · doi:10.1097/00003246-200211000-00008 · Cited by 310
“Although this limit has been clearly settled as an injury threshold, there is uncertainty about additional benefits provided by lower values (39).”
BackgroundThe "baby lung" became an adult
Gattinoni, L., Marini, J. J., Pesenti, A., Quintel, M., Mancebo, J., & Brochard, L. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4200-8 · Cited by 304
“The widely accepted surrogate for stress is the airway plateau pressure, and 30 cmH2O is the suggested limit [55].”
BackgroundThe future of mechanical ventilation: lessons from the present and the past
Gattinoni, L., Marini, J. J., Collino, F., Maiolo, G., Rapetti, F., Tonetti, T., Vasques, F., & Quintel, M. (2017) · Critical Care · doi:10.1186/s13054-017-1750-x · Cited by 279
“In the editorial accompanying the ARMA trial, 32 cmH2O plateau pressure was suggested as an upper safety limit for (passive) mechanical ventilation [50].”
BackgroundGattinoni, L., Chiumello, D., Carlesso, E., & Valenza, F. (2004) · Critical Care · doi:10.1186/cc2854 · Cited by 287
“30 and 35 cmH2O may give widely differing transpulmonary pressures [28–30] in patients with normal or increased chest wall elastance.”
BackgroundDriving pressure and mechanical power: new targets for VILI prevention
Tonetti, T., Vasques, F., Rapetti, F., Maiolo, G., Collino, F., Romitti, F., Camporota, L., Cressoni, M., Cadringher, P., Quintel, M., et al. (2017) · Annals of Translational Medicine · doi:10.21037/atm.2017.07.08 · Cited by 258
“The level of pressure considered to be harmful had not been defined until the ARMA trial data were available (13), which suggested that a value of 30 cmH2O of airway pressure was the maximum tolerable during mechanical ventilation (14).”
BackgroundLow-Tidal-Volume Ventilation in the Acute Respiratory Distress Syndrome
Malhotra, A. (2007) · New England Journal of Medicine · doi:10.1056/nejmct074213 · Cited by 217
Impact of Randomized Trial Results on Acute Lung Injury Ventilator Therapy in Teaching Hospitals
Weinert, C. R., Gross, C. R., & Marinelli, W. A. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200205-478oc · Cited by 213
Kalhan, R., Mikkelsen, M., Dedhiya, P., Christie, J., Gaughan, C., Lanken, P. N., Finkel, B., Gallop, R., & Fuchs, B. D. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000198328.83571.4a · Cited by 187
Low intraoperative tidal volume ventilation with minimal PEEP is associated with increased mortality
Levin, M. A., McCormick, P. J., Lin, H. M., Hosseinian, L., & Fischer, G. W. (2014) · British Journal of Anaesthesia · doi:10.1093/bja/aeu054 · Cited by 187
Mechanical power at a glance: a simple surrogate for volume-controlled ventilation
Giosa, L., Busana, M., Pasticci, I., Bonifazi, M., Macrì, M. M., Romitti, F., Vassalli, F., Chiumello, D., Quintel, M., Marini, J. J., et al. (2019) · Intensive Care Medicine Experimental · doi:10.1186/s40635-019-0276-8 · Cited by 166
Integrated Use of Bedside Lung Ultrasound and Echocardiography in Acute Respiratory Failure
Bataille, B., Riu, B., Ferré, F., Moussot, P.-E., Mari, A., Brunel, E., Ruiz, J., Mora, M., Fourcade, O., Genestal, M., et al. (2014) · CHEST Journal · doi:10.1378/chest.14-0681 · Cited by 167
Deans, K. J., Minneci, P. C., Suffredini, A. F., Danner, R. L., Hoffman, W. D., Ciu, X., Klein, H. G., Schechter, A. N., Banks, S. M., Eichacker, P. Q., et al. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000266584.40715.a6 · Cited by 159
Effect of tidal volume in children with acute hypoxemic respiratory failure
Khemani, R. G., Conti, D. V., Alonzo, T. A., Bart, R. D., & Newth, C. J. L. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1527-z · Cited by 165
“Moreover, evidence in both adults and children suggests that lung protective strategies should not be one-size fits all, but rather catered to lung disease severity [7, 8].”
BackgroundMechanical ventilation: lessons from the ARDSNet trial
Slutsky, A. S., & Ranieri, V. M. (2000) · Respiratory Research · doi:10.1186/rr15 · Cited by 159
“This was one of the explanations put forward in the New England Journal of Medicine editorial by Dr MJ Tobin that accompanied the ARDSNet publication [20].”
BackgroundDurante, G. D., Turco, M. D., Rustichini, L., Cosimini, P., Giunta, F., Hudson, L. D., Slutsky, A. S., & Ranieri, V. M. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2105050 · Cited by 160
Airway pressures, tidal volumes, and mortality in patients with acute respiratory distress syndrome
Ferguson, N. D., Frutos-Vivar, F., Esteban, A., Anzueto, A., Alía, I., Brower, R. G., Stewart, T. E., Apezteguía, C., González, M., Soto, L., et al. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000150652.91411.66 · Cited by 139
“When we compared the change in tidal volume between days 1 and 3, patients with a day 1 plateau pressure of 32 cm H2O (the 75th percentile in these patients, and a previously recommended threshold (15)) had a mean reduction of 0.”
BackgroundDreyfuss, D., Ricard, J.-D., & Saumon, G. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200206-611cp · Cited by 136
Management of ARDS – What Works and What Does Not
Banavasi, H. V. R., Nguyen, P., Osman, H., & Soubani, A. O. (2020) · The American Journal of the Medical Sciences · doi:10.1016/j.amjms.2020.12.019 · Cited by 166
“2.(26) Extracorporeal removal of carbon dioxide (ECCO2 R) is currently being studied; is another strategy to maintain low tidal volumes or reduce tidal volumes to even lower levels of approximately 3 mL/Kg of predicted body weight (sometimes referred to as ultra-protective ventilation).”
Mechanical ventilation in ARDS: One size does not fit all*
Deans, K. J., Minneci, P. C., Cui, X., Banks, S. M., Natanson, C., & Eichacker, P. Q. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000162384.71993.a3 · Cited by 125
Köner, Ö., Çelebi, S. S., Balcı, H., Çetin, G., Karaoğlu, K., & Çakar, N. (2004) · Intensive Care Medicine · doi:10.1007/s00134-003-2104-5 · Cited by 112
Low Tidal Volume Ventilation Use in Acute Respiratory Distress Syndrome*
Weiss, C. H., Baker, D. W., Weiner, S., Bechel, M. A., Ragland, M. F., RADEMAKER, A. W., Weitner, B. B., Agrawal, A., Wunderink, R. G., & Persell, S. D. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001710 · Cited by 121
“Fifth, some controversy exists as to what constitutes lungprotective ventilation, specifically whether achieving a plateau pressure less than or equal to 30 cm H 2 O is at least as important as achieving a low tidal volume (11, 18, 29, 30), although other evidence suggests that low tidal volumes improve outcomes regar…”
BackgroundCurley, G. F., Ansari, B., Hayes, M., Devaney, J., Masterson, C. H., Ryan, A. E., Barry, F., O’Brien, T., Toole, D. O., & Laffey, J. G. (2013) · Anesthesiology · doi:10.1097/aln.0b013e318287ba08 · Cited by 122
“After recovery, animals were randomized to receive: (1) no therapy, n = 4; (2) intratracheal vehicle (phosphate-buffered saline, 300 μl, n = 8); (3) intratracheal fibroblasts (4 × 106 cells, n = 8); (4) intratracheal MSCs (4 × 106 cells, n = 8); (5) intratracheal conditioned medium (300 μl, n = 8); or (6) intravenous…”
MethodEffects of a Clinical Trial on Mechanical Ventilation Practices in Patients with Acute Lung Injury
Checkley, W., Brower, R., Korpak, A., & Thompson, B. T. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200709-1424oc · Cited by 104
“Other authors suggested that there was a safe upper limit for plateau pressures of approximately 30 to 35 cm H2O (38, 39).”
BackgroundPositive end-expiratory pressure: how to set it at the individual level
Gattinoni, L., Collino, F., Maiolo, G., Rapetti, F., Romitti, F., Tonetti, T., Vasques, F., & Quintel, M. (2017) · Annals of Translational Medicine · doi:10.21037/atm.2017.06.64 · Cited by 114
“Of note, at the recommended plateau pressure of 30 cmH2O (32), a consistent fraction of the lung (up to 30% in severe ARDS) remains closed (28).”
BackgroundVentilatory Failure, Ventilator Support, and Ventilator Weaning
Tobin, M. J., Laghi, F. A., & Jubran, A. (2012) · Comprehensive physiology · doi:10.1002/cphy.c110030 · Cited by 112
Self-citationVieillard‐Baron, A., Prin, S., Augarde, R., Desfonds, P., Page, B., Beauchet, A., & Jardin, F. (2002) · Critical Care Medicine · doi:10.1097/00003246-200207000-00001 · Cited by 98
Petrucci, N., & Iacovelli, W. (2004) · The Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003844.pub2 · Cited by 94
Steinbrook, R. (2003) · New England Journal of Medicine · doi:10.1056/nejmhpr030349 · Cited by 89
Why protect the right ventricle in patients with acute respiratory distress syndrome?
Vieillard‐Baron, A., & Jardin, F. (2003) · Current Opinion in Critical Care · doi:10.1097/00075198-200302000-00004 · Cited by 76
Impact of positive end-expiratory pressure on the definition of acute respiratory distress syndrome
Estenssoro, E., Dubín, A., Laffaire, E., Canales, H. S., Sáenz, G., Moseinco, M. C., & Bachetti, P. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1943-4 · Cited by 76
“All patients were ventilated with tidal volumes in the range of 5–6 ml/kg unless there were contraindications for hypercapnia, and plateau pressures were kept under 30 cmH2O), according to protective ventilatory strategies recently developed [9, 19, 20].”
MethodPathways of inflammation and cell death in the lung: modulation by vasoactive intestinal peptide
Said, S. I., & Dickman, K. G. (2000) · Regulatory Peptides · doi:10.1016/s0167-0115(00)00174-9 · Cited by 71
Targeting transpulmonary pressure to prevent ventilator-induced lung injury
Gattinoni, L., Giosa, L., Bonifazi, M., Pasticci, I., Busana, M., Macrí, M. M., Romitti, F., Vassalli, F., & Quintel, M. (2019) · Expert Review of Respiratory Medicine · doi:10.1080/17476348.2019.1638767 · Cited by 73
“study [1] was suggested at 32 cmH2O in an editorial accompanying the original ARMA report [51].”
BackgroundProne ventilation in acute respiratory distress syndrome
Guérin, C. (2014) · European Respiratory Review · doi:10.1183/09059180.00001114 · Cited by 74
Oddo, M., Nduom, E. K.-E., Frangos, S. G., Mackenzie, L., Chen, I., Maloney‐Wilensky, E., Kofke, W. A., Levine, J. M., & LeRoux, P. D. (2010) · Neurosurgery · doi:10.1227/01.neu.0000371979.48809.d9 · Cited by 67
Ventilator-Induced Lung Injury
Tsuchida, S., & Kavanagh, B. P. (2014) · Springer eBooks · doi:10.1007/978-1-4471-6356-5_13 · Cited by 61
“Indeed, as reviewed through this chapter, such work represented the clinical confi rmation of multiple laboratory studies [3].”
BackgroundThe Design of Future Pediatric Mechanical Ventilation Trials for Acute Lung Injury
Khemani, R. G., & Newth, C. J. L. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201004-0606ci · Cited by 62
“previous controversy (34, 35) most notably in the aftermath of the ARDS Network VT study (36, 37).”
BackgroundF ifty Y ears of R esearch in ARDS. V t Selection in Acute Respiratory Distress Syndrome
Sahetya, S. K., Mancebo, J., & Brower, R. G. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201708-1629ci · Cited by 65
Gillette, M. A., & HESS, D. R. (2001) · Respiratory Care · doi:10.1177/002013240104600204 · Cited by 49
Moran, J. L., Bersten, A. D., & Solomon, P. J. (2005) · Intensive Care Medicine · doi:10.1007/s00134-004-2506-z · Cited by 53
“The smaller difference in plateau pressures between treatment arms had already been advanced in the accompanying editorial [3] to the ARDS Network publication as a potential reason for the failure to demonstrate a treatment effect in three previous trials [4, 5, 6] of lung protective ventilation.”
BackgroundAre We Really Reducing Tidal Volume—And Should We?
Ricard, J.-D. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2303003 · Cited by 48
Is the mechanical power the final word on ventilator-induced lung injury?—we are not sure
Vasques, F., Duscio, E., Pasticci, I., Romitti, F., Vassalli, F., Quintel, M., & Gattinoni, L. (2018) · Annals of Translational Medicine · doi:10.21037/atm.2018.08.17 · Cited by 53
Hough, C. L., Kallet, R. H., Ranieri, V. M., Rubenfeld, G. D., Luce, J. M., & Hudson, L. D. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000155782.86244.42 · Cited by 41
What Is Evidence-Based Medicine and Why Should I Care?
HESS, D. R. (2004) · Respiratory Care · doi:10.4187/respcare.04490730 · Cited by 50
Zhou, J., Wang, C., Wu, J. S., Fukunaga, A., Cheng, Z., Wang, J., Yamauchi, A., Yodoi, J., & Tian, H. (2019) · Antioxidants and Redox Signaling · doi:10.1089/ars.2019.7807 · Cited by 40
“…in a range of proinflammatory cytokines accompanied by rapid recruitment of neutrophils into the alveolar space, endothelial injury and dysfunction, platelet aggregation and microthrombus formation, interstitial and alveolar edema, alveolar epithelial cell death, and macrophage activation (5, 132).”
Sedeek, K., Takeuchi, M., Suchodolski, K., Vargas, S. O., Shimaoka, M., Schnitzer, J. J., & Kacmarek, R. M. (2003) · Anesthesiology · doi:10.1097/00000542-200311000-00016 · Cited by 37
Vinko Tomicic, F., Espinoza, M., Andresen, M., Molina, J., Calvo, M. A., Héctor Ugarte, E., de Godoy, J. A. P., Gálvez, S. C., Maurelia, J. C., Delgado, I., et al. (2008) · Revista médica de Chile · doi:10.4067/s0034-98872008000800001 · Cited by 54
Ventilator-induced lung injury
ADAMS, A., Simonson, D. A., & Dries, D. J. (2003) · Respiratory Care Clinics · doi:10.1016/s1078-5337(03)00042-x · Cited by 33
“A subsequent review recommended reducing the limit to less than 32 cm H2O [36] .”
Fessler, H., & HESS, D. R. (2007) · Respiratory Care · doi:10.4187/respcare.07520595 · Cited by 38
What Is the Legacy of the National Institutes of Health Acute Respiratory Distress Syndrome Network?
Kallet, R. H. (2009) · Respiratory Care · doi:10.4187/002013209793800330 · Cited by 31
Godet, T., Jabaudon, M., Blondonnet, R., Tremblay, A., Audard, J., Rieu, B., Pereira, B., Garcier, J., Futier, E., & Constantin, J. (2018) · Critical Care · doi:10.1186/s13054-017-1924-6 · Cited by 36
“This 30-cmH20 pressure seems to limit the risk of distension-related lung injury as reported by Boussarsar [41] and Tobin [42].”
BackgroundUSE OF LOW TIDAL VOLUME IN SEPTIC SHOCK MAY DECREASE SEVERITY OF SUBSEQUENT ACUTE LUNG INJURY
Su, F., Nguyen, N. D., Créteur, J., Cai, Y., Nagy, N., Anh-Dung, H., Amaral, A. C. K.-B., de Carvalho, F. B., Chochrad, D., & Vincent, J. (2004) · Shock · doi:10.1097/01.shk.0000131488.89874.8a · Cited by 31
“These observations form the rationale for newer, “gentler” approaches to managing mechanical ventilation in established lung injury (10).”
BackgroundPhysiologic Basis of Mechanical Ventilation
Tobin, M. J. (2018) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201705-417kv · Cited by 30
Self-citationBudesonide ameliorates lung injury induced by large volume ventilation
Ju, Y., Yu, K., & Wang, G. (2016) · BMC Pulmonary Medicine · doi:10.1186/s12890-016-0251-z · Cited by 29
“Peter JV, John P, Graham PL, Moran JL, George IA, Bersten A. Corticosteroids in the prevention and treatment of acute respiratory distress syndrome (ARDS) in adults: meta-analysis.”
BackgroundInfluentialConventional Mechanical Ventilation in Acute Lung Injury and Acute Respiratory Distress Syndrome
Ramnath, V. R., HESS, D. R., & Thompson, B. (2006) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2006.06.009 · Cited by 33
Effect of different pulses of nitric oxide on venous admixture inthe anaesthetizedhorse
Heinonen, E., Nyman, G. C., ̈inen, P. M., & Ho¨gman, M. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/88.3.394 · Cited by 36
Reduced tidal volumes and lung protective ventilatory strategies: where do we go from here?
Gattinoni, L., Chiumello, D., & Russo, R. (2002) · Current Opinion in Critical Care · doi:10.1097/00075198-200202000-00008 · Cited by 30
Bench-to-bedside review: adjuncts to mechanical ventilation in patients with acute lung injury.
Rouby, J., & Lü, Q. (2005) · Critical Care · doi:10.1186/cc3763 · Cited by 27
“In patients with ARDS, increasing the ventilator respiratory rate is the simplest way to enhance CO2 elimination when tidal volume is reduced [5,16,17].”
BackgroundNew therapies for adults with acute lung injury: High-frequency oscillatory ventilation
Ferguson, N. D., & Stewart, T. E. (2002) · Critical Care Clinics · doi:10.1016/s0749-0704(03)00067-8 · Cited by 25
Ramadori, G. P. (2022) · Medical Sciences · doi:10.3390/medsci10040058 · Cited by 32
Hypercapnia during acute respiratory distress syndrome: the tree that hides the forest!
Repessé, X., & Vieillard‐Baron, A. (2017) · Journal of Thoracic Disease · doi:10.21037/jtd.2017.05.69 · Cited by 22
“It has been suggested that the positive results of the ARMA study (31) could at least in part be explained by the effort to correct hypercapnia by increasing RR (32,33).”
Mohan, D., & Angus, D. C. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181f202c3 · Cited by 20
“One excellent example of this failure to adopt best practices comes from the adult respiratory distress syndrome (ARDS) literature.”
MethodInfluentialUtilización de la ventilación mecánica en 72 unidades de cuidados intensivos en España
Frutos–Vivar, F., Alía, I., Lorenzo, M. R., Pardo, J. G., Nolla, M. D. C., IbÁñez, J., Tirapu, J. P., Macías, S., Blanco, J., Benito, S., et al. (2003) · Medicina Intensiva · doi:10.1016/s0210-5691(03)79858-1 · Cited by 20
Graham, M. R., Haberman, C. J., Brewster, J. F., Girling, L. G., McManus, B. M., & Mutch, W. A. C. (2005) · Respiratory Research · doi:10.1186/1465-9921-6-64 · Cited by 21
Endothelial Progenitor Cells Attenuate Ventilator-Induced Lung Injury with Large-Volume Ventilation
Ju, Y., Geng, Y., Wang, X., Gong, J., Zhu, J., & Gao, W. (2019) · Cell Transplantation · doi:10.1177/0963689719874048 · Cited by 18
ARDS (»acute respiratory distress syndrome«)
Fresenius, M., & Heck, M. C. (2011) · Springer eBooks · doi:10.1007/978-3-642-16879-6_23 · Cited by 18
Ziaka, M., Makris, D. A., Fotakopoulos, G., Tsilioni, I., Befani, C. D., Liakos, P., Zygoulis, P., & Zakynthinos, E. G. (2020) · American Journal of Critical Care · doi:10.4037/ajcc2020161 · Cited by 18
Rubenfeld, G. D. (2003) · JAMA · doi:10.1001/jama.290.3.397-a · Cited by 17
“In managing ARDS, the unequivocal lesson supported by data from extensive laboratory research and confirmed by clinical trials is that use of mechanical ventilation with lower tidal volumes and inflation pressures reduces mortality.(20)”
BackgroundMethodInfluentialVentilación mecánica en España, 1998-2016: epidemiología y desenlaces
Peñuelas, Ó., Frutos–Vivar, F., Muriel, A., Mancebo, J., García-Jiménez, A., de Pablo, R., Valledor, M., Ferrer, M., León, M., Quiroga, J. M., et al. (2020) · Medicina Intensiva · doi:10.1016/j.medin.2020.04.024 · Cited by 21
“Cardiovascular 356 (32) 180 (36) 680 (44) 556 (49)”
Low tidal volume, high respiratory rate and auto-PEEP: the importance of the basics.
Patroniti, N. A., & Pesenti, A. M. (2003) · Critical Care · doi:10.1186/cc1883 · Cited by 16
“As stated by Tobin [6], “.”
Romano, T. G., Correia, M. D. T., Mendes, P. V., Zampieri, F. G., Maciel, A. T., & Park, M. (2016) · Revista Brasileira de Terapia Intensiva · doi:10.5935/0103-507x.20160009 · Cited by 16
“However, the CO2 effect per se (without the concomitant effect of the tidal overdistention reduction) on lung protection and clinical outcomes is controversial.(20-23) Patients with acute and persistent hypercapnia, in the absence of renal failure, evolve a metabolic compensation toward pH normalization in a short tim…”
BackgroundBosma, K. J., Fanelli, V., & Ranieri, V. M. (2005) · Current Opinion in Anaesthesiology · doi:10.1097/01.aco.0000162831.41097.6b · Cited by 17
Tidal Volumes in Acute Respiratory Distress Syndrome—One Size Does Not Fit All
Brower, R. G., & Thompson, B. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000191132.12653.05 · Cited by 16
Predicted body weight during mechanical ventilation: using arm demispan to aid clinical assessment
Deane, A. M., Reid, D. A., & Tobin, A. E. (2008) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)01084-0 · Cited by 16
Wang, W., Scharfstein, D. O., Wang, C., Daniels, M. J., Needham, D. M., & Brower, R. G. (2011) · Journal of the Royal Statistical Society Series C (Applied Statistics) · doi:10.1111/j.1467-9876.2010.00757.x · Cited by 15
“…that the recommendation of a tidal volume goal of 6 ml (kg PBW)−1 is not optimal because the traditional tidal volume strategy that was used in the trial did not accurately represent usual care approaches that clinicians were using when the trial was conducted (Eichacker et al., 2002; Tobin, 2000).”
Minneci, P. C., Eichacker, P. Q., Danner, R. L., Banks, S. M., Natanson, C., & Deans, K. J. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-0999-6 · Cited by 16
“Fig.1 Potential effects of a usual practice control group in the ARDSNet low tidal volume (ARMA) trial [8, 9 , 23].”
Background
Metadata
- Authors
- Tobin, M. J.
- Corresponding author
- Tobin, Martin J.
- ORCID
- Tobin, Martin J.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2000-05-04
- Volume
- 342
- Issue
- 18
- Pages
- 1360-1361
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2047833061
- Cited by
- 177
- References
- 10
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 1 · 2022: 3 · 2021: 12 · 2020: 6 · 2019: 6 · 2018: 4 · 2017: 9 · 2016: 4 · 2014: 6 · 2013: 5 · 2012: 10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Neonatal Respiratory Health Research
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Nosocomial Infections in ICU
- Keywords
- acute respiratory distress syndrome, non-cardiogenic pulmonary edema, alveolar damage, mechanical ventilation, ventilator-induced lung injury, alveolar rupture, alveolar hemorrhage, hypoxemia, supplemental oxygen, history of research
- MeSH terms
- Humans, Positive-Pressure Respiration, Respiration, Artificial, Respiratory Distress Syndrome, Tidal Volume
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.