The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
A Randomized Comparison of a Sirolimus-Eluting Stent with a Standard Stent for Coronary Revascularization
Open accessAbstract
BACKGROUND: The need for repeated treatment of restenosis of a treated vessel remains the main limitation of percutaneous coronary revascularization. Because sirolimus (rapamycin) inhibits the proliferation of lymphocytes and smooth-muscle cells, we compared a sirolimus-eluting stent with a standard uncoated stent in patients with angina pectoris. METHODS: We performed a randomized, double-blind trial to compare the two types of stents for revascularization of single, primary lesions in native coronary arteries. The trial included 238 patients at 19 medical centers. The primary end point was in-stent late luminal loss (the difference between the minimal luminal diameter immediately after the procedure and the diameter at six months). Secondary end points included the percentage of in-stent stenosis of the luminal diameter and the rate of restenosis (luminal narrowing of 50 percent or more). We also analyzed a composite clinical end point consisting of death, myocardial infarction, and percutaneous or surgical revascularization at 1, 6, and 12 months. RESULTS: At six months, the degree of neointimal proliferation, manifested as the mean (+/-SD) late luminal loss, was significantly lower in the sirolimus-stent group (-0.01+/-0.33 mm) than in the standard-stent group (0.80+/-0.53 mm, P<0.001). None of the patients in the sirolimus-stent group, as compared with 26.6 percent of those in the standard-stent group, had restenosis of 50 percent or more of the luminal diameter (P<0.001). There were no episodes of stent thrombosis. During a follow-up period of up to one year, the overall rate of major cardiac events was 5.8 percent in the sirolimus-stent group and 28.8 percent in the standard-stent group (P<0.001). The difference was due entirely to a higher rate of revascularization of the target vessel in the standard-stent group. CONCLUSIONS: As compared with a standard coronary stent, a sirolimus-eluting stent shows considerable promise for the prevention of neointimal proliferation, restenosis, and associated clinical events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Self-citationFischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Self-citationIntravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
Letter: Grading of angina pectoris.
Campeau, L. (1976) · Circulation · doi:10.1161/circ.54.3.947585 · Cited by 1,601
Unstable angina. A classification.
Braunwald, E. (1989) · Circulation · doi:10.1161/01.cir.80.2.410 · Cited by 1,366
Patterns and Mechanisms of In-Stent Restenosis: A Serial Intravascular Ultrasound Study
Hoffmann, R., Mintz, G. S., Dussaillant, G. R., Popma, J. J., Pichard, A. D., Satler, L. F., Kent, K. M., Griffin, J., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.6.1247 · Cited by 1,247
Comparison of Coronary-Artery Bypass Surgery and Stenting for the Treatment of Multivessel Disease
Serruys, P. W., Unger, F., Sousa, J. E., Jatene, A., Bonnier, H. J. R. M., Schönberger, J. P. A. M., Buller, N., Bonser, R., van den Brand, M. J. B., van Herwerden, L. A., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200104123441502 · Cited by 1,114
Self-citationHolmes, D. R., Vlietstra, R. E., Smith, H. C., Vetrovec, G. W., Kent, K. M., Cowley, M. J., Faxon, D. P., Gruentzig, A. R., Kelsey, S. F., Detre, K. M., et al. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90752-5 · Cited by 1,113
Catheter-Based Radiotherapy to Inhibit Restenosis after Coronary Stenting
Teirstein, P. S., Massullo, V., Jani, S., Popma, J. J., Mintz, G. S., Russo, R. J., Schatz, R. A., Guarneri, E. M., Steuterman, S., Morris, N. B., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199706123362402 · Cited by 942
Sousa, J. E., Costa, M. A., Abizaid, A., Abizaid, A. S., Feres, F., Pinto, I. M. F., Seixas, A. C., Staico, R., Mattos, L. A., Sousa, A. G. M. R., et al. (2001) · Circulation · doi:10.1161/01.cir.103.2.192 · Cited by 793
Self-citationStent-Based Delivery of Sirolimus Reduces Neointimal Formation in a Porcine Coronary Model
Suzuki, T., Kopia, G., Hayashi, S.-I., Bailey, L. R., Llanos, G., Wilensky, R., Klugherz, B. D., Papandreou, G., Narayan, P., Leon, M. B., et al. (2001) · Circulation · doi:10.1161/hc3601.093987 · Cited by 708
Self-citationTopol, E. J., Leya, F., Pinkerton, C. A., Whitlow, P. L., Hofling, B., Simonton, C. A., Masden, R. R., Serruys, P. W., Leon, M. B., Williams, D. O., et al. (1993) · New England Journal of Medicine · doi:10.1056/nejm199307223290401 · Cited by 698
Self-citationSerruys, P. W., van Hout, B., Bonnier, H., Legrand, V., Garcia, E., Macaya, C., Sousa, E., van der Giessen, W., Colombo, A., Seabra-Gomes, R., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11128-x · Cited by 650
Self-citationRoubin, G. S., Cannon, A. D., Agrawal, S. K., Macander, P. J., Dean, L. S., Baxley, W. A., & Breland, J. (1992) · Circulation · doi:10.1161/01.cir.85.3.916 · Cited by 582
Gallo, R., Padurean, A., Jayaraman, T., Marx, S., Roque, M., Adelman, S., Chesebro, J., Fallon, J., Fuster, V., Marks, A., et al. (1999) · Circulation · doi:10.1161/01.cir.99.16.2164 · Cited by 490
Rapamycin in transplantation: A review of the evidence
Saunders, R. N., Metcalfe, M. S., & Nicholson, M. L. (2001) · Kidney International · doi:10.1046/j.1523-1755.2001.00460.x · Cited by 461
Bench to Bedside: The Development of Rapamycin and Its Application to Stent Restenosis
Marx, S. O., & Marks, A. R. (2001) · Circulation · doi:10.1161/01.cir.104.8.852 · Cited by 447
Mudra, H., di Mario, C., de Jaegere, P., Figulla, H. R., Macaya, C., Zahn, R., Wennerblom, B., Rutsch, W., Voudris, V., Regar, E., et al. (2001) · Circulation · doi:10.1161/hc3701.096064 · Cited by 226
Burke, S. E., Lubbers, N. L., Chen, Y., Hsieh, G. C., Mollison, K. W., Luly, J. R., & Wegner, C. D. (1999) · Journal of Cardiovascular Pharmacology · doi:10.1097/00005344-199906000-00001 · Cited by 100
Data and Safety Monitoring Boards
Friedman, L. M. (2002) · Elsevier eBooks · doi:10.1016/b978-012274065-7/50008-3 · Cited by 48
Cited by
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Designing materials for biology and medicine
Langer, R., & Tirrell, D. A. (2004) · Nature · doi:10.1038/nature02388 · Cited by 3,198
Iakovou, I. (2005) · JAMA · doi:10.1001/jama.293.17.2126 · Cited by 3,132
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Metadata
- Authors
- Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., Molnàr, F., & Falotico, R.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2002-06-06
- Volume
- 346
- Issue
- 23
- Pages
- 1773-1780
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2079818105
- Cited by
- 4,033
- References
- 20
- FWCI
- 333.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.