The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Cardiac-Resynchronization Therapy with or without an Implantable Defibrillator in Advanced Chronic Heart Failure
Abstract
BACKGROUND: We tested the hypothesis that prophylactic cardiac-resynchronization therapy in the form of biventricular stimulation with a pacemaker with or without a defibrillator would reduce the risk of death and hospitalization among patients with advanced chronic heart failure and intraventricular conduction delays. METHODS: A total of 1520 patients who had advanced heart failure (New York Heart Association class III or IV) due to ischemic or nonischemic cardiomyopathies and a QRS interval of at least 120 msec were randomly assigned in a 1:2:2 ratio to receive optimal pharmacologic therapy (diuretics, angiotensin-converting-enzyme inhibitors, beta-blockers, and spironolactone) alone or in combination with cardiac-resynchronization therapy with either a pacemaker or a pacemaker-defibrillator. The primary composite end point was the time to death from or hospitalization for any cause. RESULTS: As compared with optimal pharmacologic therapy alone, cardiac-resynchronization therapy with a pacemaker decreased the risk of the primary end point (hazard ratio, 0.81; P=0.014), as did cardiac-resynchronization therapy with a pacemaker-defibrillator (hazard ratio, 0.80; P=0.01). The risk of the combined end point of death from or hospitalization for heart failure was reduced by 34 percent in the pacemaker group (P<0.002) and by 40 percent in the pacemaker-defibrillator group (P<0.001 for the comparison with the pharmacologic-therapy group). A pacemaker reduced the risk of the secondary end point of death from any cause by 24 percent (P=0.059), and a pacemaker-defibrillator reduced the risk by 36 percent (P=0.003). CONCLUSIONS: In patients with advanced heart failure and a prolonged QRS interval, cardiac-resynchronization therapy decreases the combined risk of death from any cause or first hospitalization and, when combined with an implantable defibrillator, significantly reduces mortality.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While clinical improvements are generally achieved, six-month nonresponder rates have been reported to be as high as 32–43%11,13, which is partially attributed to anatomic constraints of lead positioning14.”
From Synchronized Biventricular Heart Pacing in a Closed-chest Porcine Model based on Wirelessly Powered Leadless Pacemakers (2020) · cites this paper as [13]
In the citing paper
“Device therapies (implantable cardioverter defibrillator [ICD], cardiac resynchronization therapy [CRT], and CRT with an implantable defibrillator [CRT-D]) have similar efficacies and risks in patients with HFrEF with or without diabetes.[522][523][524][525]”
From 2023 ESC guidelines for the management of cardiovascular disease in patients with diabetes. (2023) · cites this paper as [524]
Citations
Cites
Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,902
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
CARDIAC RESYNCHRONIZATION IN CHRONIC HEART FAILURE
Braham, W. I. T. A., Isher, W. E. G. F., Mith, L. S., Elurgio, D. A. B. D., Eon, A. N. R. L., Oh, E., Ocovic, D. U. Z. K., Acker, M. G., Lavell, L. C., Ayes, D. A. L. H., et al. (2002) · Cited by 3,808
A Multiple Testing Procedure for Clinical Trials
O'Brien, P. C., & Fleming, T. R. (1979) · Biometrics · doi:10.2307/2530245 · Cited by 3,311
Discrete sequential boundaries for clinical trials
GORDON LAN, K. K., & DEMETS, D. L. (1983) · Biometrika · doi:10.1093/biomet/70.3.659 · Cited by 2,310
Self-citationDiscrete Sequential Boundaries for Clinical Trials
Lan, K. K. G., & DeMets, D. L. (1983) · Biometrika · doi:10.2307/2336502 · Cited by 2,310
Self-citationSt John Sutton, M. G., Plappert, T., Abraham, W. T., Smith, A. L., DeLurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Fisher, W. G., Ellestad, M., et al. (2003) · Circulation · doi:10.1161/01.cir.0000065226.24159.e9 · Cited by 1,124
Auricchio, A., Stellbrink, C., Sack, S., Block, M., Vogt, J. Ü., Bakker, P., Huth, C., Schöndube, F., Wolfhard, U., Böcker, D., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01895-8 · Cited by 1,026
Linde, C., Leclercq, C., Rex, S., Garrigue, S., Lavergne, T., Cazeau, S., McKenna, W., Fitzgerald, M., Deharo, J.-C., Alonso, C., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01932-0 · Cited by 973
Baldasseroni, S., Opasich, C., Gorini, M., Lucci, D., Marchionni, N., Marini, M., Campana, C., Perini, G., Deorsola, A., Masotti, G., et al. (2002) · American Heart Journal · doi:10.1067/mhj.2002.121264 · Cited by 800
Nelson, G. S., Berger, R. D., Fetics, B. J., Talbot, M., Spinelli, J. C., Hare, J. M., & Kass, D. A. (2000) · Circulation · doi:10.1161/01.cir.102.25.3053 · Cited by 758
Self-citationHiggins, S. L., Hummel, J. D., Niazi, I. K., Giudici, M. C., Worley, S. J., Saxon, L. A., Boehmer, J. P., Higginbotham, M. B., De Marco, T., Foster, E., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)01042-8 · Cited by 712
Self-citationSøgaard, P., Egeblad, H., Kim, W. Y., Jensen, H. K., Pedersen, A. K., Kristensen, B. Ø., & Mortensen, P. T. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02010-7 · Cited by 603
Intraventricular conduction delay: a prognostic marker in chronic heart failure
Shamim, W., Francis, D. P., Yousufuddin, M., Varney, S., Pieopli, M. F., Anker, S. D., & Coats, A. J. S. (1999) · International Journal of Cardiology · doi:10.1016/s0167-5273(99)00077-7 · Cited by 406
Bristow, M. R., Feldman, A. M., & Saxon, L. A. (2000) · Journal of Cardiac Failure · doi:10.1054/jcaf.2000.9501 · Cited by 328
Self-citationSaxon, L. A., De Marco, T., Schafer, J., Chatterjee, K., Kumar, U. N., & Foster, E. (2002) · Circulation · doi:10.1161/hc1102.105730 · Cited by 292
Self-citationSøgaard, P., Kim, W. Y., Jensen, H. K., Mortensen, P. T., Pedersen, A. K., Kristensen, B. Ø., & Egeblad, H. (2001) · Cardiology · doi:10.1159/000047369 · Cited by 101
Kawaguchi, M., Murabayashi, T., Fetics, B. J., Nelson, G. S., Samejima, H., Nevo, E., & Kass, D. A. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01883-1 · Cited by 94
Self-citationCardiac resynchronization therapy for heart failure: biventricular pacing and beyond
Abraham, W. T. (2002) · Current Opinion in Cardiology · doi:10.1097/00001573-200207000-00004 · Cited by 84
Data and Safety Monitoring Boards
Friedman, L. M. (2002) · Elsevier eBooks · doi:10.1016/b978-012274065-7/50008-3 · Cited by 48
Biventricular Pacing in Patients with ICD: How Many Patients are Possible Candidates?
Werling, C., Weisse, U., Siemon, G., Kiessling, A., Rameken, M., Schwacke, H., Saggau, W., Senges, J., & Seidl, K.-H. (2002) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-2002-26702 · Cited by 21
Can the optimum dosage of resynchronization therapy be derived from the intracardiac electrogram?
Auricchio, A., Kramer, A., Spinelli, J., Ding, J., Yu, Y., Hoersch, W., Butter, C., & Stellbrink, C. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)80546-0 · Cited by 18
Cardiac resynchronization therapy
Trautmann, S. I., Kloss, M., & Auricchio, A. (2002) · Current Cardiology Reports · doi:10.1007/s11886-002-0036-2 · Cited by 14
Cited by
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab670 · Cited by 19,442
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
“Both for GDMT and other recommended drug treatment regimens, the reader is advised to confirm dosages with product insert material and to evaluate carefully for contraindications and drug-drug interactions.”
BackgroundInfluential2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw128 · Cited by 11,429
2019 ESC Guidelines for the diagnosis and management of chronic coronary syndromes
Knuuti, J., Wijns, W., Saraste, A., Capodanno, D., Barbato, E., Funck-Brentano, C., Prescott, E., Storey, R. F., Deaton, C., Cuisset, T., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz425 · Cited by 7,166
Metadata
- Authors
- Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., DeVries, D. W., & Feldman, A. M.
- Affiliations
- University of Colorado Health (US)
- University of Southern California (US)
- Penn State Milton S. Hershey Medical Center (US)
- Bryan Health (US)
- Johns Hopkins Hospital (US)
- Veterans Health Administration (US)
- Pfizer (United States) (US)
- University of Wisconsin–Madison (US)
- Thomas Jefferson University (US)
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2004-05-20
- Volume
- 350
- Issue
- 21
- Pages
- 2140-2150
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2130907431
- Cited by
- 5,812
- References
- 22
- Citations by year
- 2026: 80 · 2025: 126 · 2024: 131 · 2023: 179 · 2022: 149 · 2021: 157 · 2020: 196 · 2019: 213 · 2018: 210 · 2017: 265 · 2016: 260 · 2015: 308 · 2014: 276 · 2013: 323 · 2012: 350
- FWCI
- 240.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
- Health Sciences › Medicine › Emergency Medicine › Cardiac Arrest and Resuscitation
- Keywords
- cardiac resynchronization therapy, implantable cardioverter-defibrillator, advanced chronic heart failure, intraventricular conduction delay, heart failure hospitalization, mortality, cardiomyopathy, QRS duration, pharmacotherapy
- MeSH terms
- Adrenergic beta-Antagonists, Aged, Angiotensin-Converting Enzyme Inhibitors, Chronic Disease, Combined Modality Therapy, Diuretics, Female, Heart Failure, Hospitalization, Humans, Male, Pacemaker, Artificial, Risk, Spironolactone, Defibrillators, Implantable, Ventricular Dysfunction, Left
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.