The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Multidetector-Row Computed Tomography in Suspected Pulmonary Embolism
Open accessAbstract
BACKGROUND: Single-detector-row computed tomography (CT) has a low sensitivity for pulmonary embolism and must be combined with venous-compression ultrasonography of the lower limbs. We evaluated whether the use of D-dimer measurement and multidetector-row CT, without lower-limb ultrasonography, might safely rule out pulmonary embolism. METHODS: We included 756 consecutive patients with clinically suspected pulmonary embolism from the emergency departments of three teaching hospitals and managed their cases according to a standardized sequential diagnostic strategy. All patients were followed for three months. RESULTS: Pulmonary embolism was detected in 194 of the 756 patients (26 percent). Among the 82 patients with a high clinical probability of pulmonary embolism, multidetector-row CT showed pulmonary embolism in 78, and 1 patient had proximal deep venous thrombosis and a CT scan that was negative for pulmonary embolism. Of the 674 patients without a high probability of pulmonary embolism, 232 (34 percent) had a negative D-dimer assay and an uneventful follow-up; CT showed pulmonary embolism in 109 patients. CT and ultrasonography were negative in 318 patients, of whom 3 had a definite thromboembolic event and 2 died of possible pulmonary embolism during follow-up (three-month risk of thromboembolism, 1.7 percent; 95 percent confidence interval, 0.7 to 3.9). Two patients had proximal deep venous thrombosis and a negative CT scan (risk, 0.6 percent; 95 percent confidence interval, 0.2 to 2.2). The overall three-month risk of thromboembolism in patients without pulmonary embolism would have been 1.5 percent (95 percent confidence interval, 0.8 to 3.0) if the D-dimer assay and multidetector-row CT had been the only tests used to rule out pulmonary embolism and ultrasonography had not been performed. CONCLUSIONS: Our data indicate the potential clinical use of a diagnostic strategy for ruling out pulmonary embolism on the basis of D-dimer testing and multidetector-row CT without lower-limb ultrasonography. A larger outcome study is needed before this approach can be adopted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prediction of Creatinine Clearance from Serum Creatinine
Cockcroft, D. W., & Gault, H. (1976) · Nephron · doi:10.1159/000180580 · Cited by 15,309
Wells, P. S., Anderson, D. R., Rodger, M., Stiell, I., Dreyer, J. F., Barnes, D., Forgie, M., Kovacs, G., Ward, J., & Kovacs, M. J. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-2-200107170-00010 · Cited by 1,438
Use of a Clinical Model for Safe Management of Patients with Suspected Pulmonary Embolism
Wells, P. S., Ginsberg, J. S., Anderson, D. R., Kearon, C., Gent, M., Turpie, A. G., Bormanis, J., Weitz, J., Chamberlain, M., Bowie, D., et al. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-129-12-199812150-00002 · Cited by 1,002
Detection of Deep-Vein Thrombosis by Real-Time B-Mode Ultrasonography
Lensing, A. W. A., Prandoni, P., Brandjes, D., Huisman, P. M., Vigo, M., Tomasella, G., Krekt, J., ten Cate, J. W., Huisman, M. V., & Büller, H. R. (1989) · New England Journal of Medicine · doi:10.1056/nejm198902093200602 · Cited by 875
Non-invasive diagnosis of venous thromboembolism in outpatients
Perrier, A., Desmarais, S., Miron, M.-J., de Moerloose, P., Lepage, R., Slosman, D., Didier, D., Unger, P.-F., Patenaude, J.-V., & Bounameaux, H. (1999) · The Lancet · doi:10.1016/s0140-6736(98)05248-9 · Cited by 791
Self-citationBritish Thoracic Society guidelines for the management of suspected acute pulmonary embolism
(2003) · Thorax · doi:10.1136/thorax.58.6.470 · Cited by 686
Assessing Clinical Probability of Pulmonary Embolism in the Emergency Ward: A Simple Score
Wicki, J., Perneger, T. V., Junod, A. F., Bounameaux, H., & Perrier, A. (2001) · Archives of Internal Medicine · doi:10.1001/archinte.161.1.92 · Cited by 589
Self-citationMusset, D., Parent, F., Meyer, G., Maître, S., Girard, P., Leroyer, C., Revel, M.-P., Carette, M.-F., Laurent, M., Charbonnier, B., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)11914-3 · Cited by 402
Self-citation(1990) · JAMA · doi:10.1001/jama.263.20.2753 · Cited by 376
Perrier, A., Roy, P.-M., Aujesky, D., Chagnon, I., Howarth, N., Gourdier, A.-L., Leftheriotis, G., Barghouth, G., Cornuz, J., Hayoz, D., et al. (2004) · The American Journal of Medicine · doi:10.1016/j.amjmed.2003.09.041 · Cited by 375
Self-citationThe Evaluation of Suspected Pulmonary Embolism
Fedullo, P. F., & Tapson, V. F. (2003) · New England Journal of Medicine · doi:10.1056/nejmcp035442 · Cited by 371
Goldhaber, S. Z. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16004-2 · Cited by 348
Peripheral Pulmonary Arteries: How Far in the Lung Does Multi-Detector Row Spiral CT Allow Analysis?
Ghaye, B., Szapiro, D., Mastora, I., Delannoy, V., Duhamel, A., Remy, J., & Remy-Jardin, M. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn32629 · Cited by 344
Perrier, A., Howarth, N., Didier, D., Loubeyre, P., Unger, P.-F., de Moerloose, P., Slosman, D. O., Junod, A. F., & Bounameaux, H. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-2-200107170-00008 · Cited by 308
Self-citationMeasurement of D-dimer in plasma as diagnostic aid in suspected pulmonary embolism
Bounameaux, H., Cirafici, P., de Moerloose, P., Schneider, P.-A., Slosman, D., Reber, G., & Unger, P.-F. (1991) · The Lancet · doi:10.1016/0140-6736(91)92158-x · Cited by 288
Self-citationPerrier, A. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.156.5.531 · Cited by 267
Self-citationSpiral Computed Tomography for Acute Pulmonary Embolism
Schoepf, U. J., Goldhaber, S. Z., & Costello, P. (2004) · Circulation · doi:10.1161/01.cir.0000128813.04325.08 · Cited by 237
Chagnon, I., Bounameaux, H., Aujesky, D., Roy, P.-M., Gourdier, A.-L., Cornuz, J., Perneger, T., & Perrier, A. (2002) · The American Journal of Medicine · doi:10.1016/s0002-9343(02)01212-3 · Cited by 229
Self-citationKruip, M. J. H. A., Slob, M. J., Schijen, J. H. E. M., van der Heul, C., & Büller, H. R. (2002) · Archives of Internal Medicine · doi:10.1001/archinte.162.14.1631 · Cited by 194
Righini, M., Aujesky, D., Roy, P., Cornuz, J., de Moerloose, P., Bounameaux, H., & Perrier, A. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.22.2483 · Cited by 110
Self-citationPerrier, A., Miron, M. ‐., Desmarais, S., de Moerloose, P., Slosman, D. O., Didier, D., Unger, P.-F., Junod, A. F., Patenaude, J., & Bounameaux, H. (2000) · Archives of Internal Medicine · doi:10.1001/archinte.160.4.512 · Cited by 96
Self-citation
Cited by
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz405 · Cited by 4,916
Self-citation2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Konstantinides, S. V., Torbicki, A., Agnelli, G., Danchin, N., Fitzmaurice, D., Galiè, N., Gibbs, J. S. R., Huisman, M. V., Humbert, M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu283 · Cited by 3,128
Self-citationGuidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Torbicki, A., Perrier, A., Konstantinides, S., Agnelli, G., Galiè, N., Pruszczyk, P., Bengel, F., Brady, A. J. B., Ferreira, D., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn310 · Cited by 2,826
Self-citationMultidetector Computed Tomography for Acute Pulmonary Embolism
Stein, P. D., Fowler, S. E., Goodman, L. R., Gottschalk, A., Hales, C. A., Hull, R. D., Leeper, K. V., Popovich, J., Quinn, D. A., Sos, T. A., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052367 · Cited by 1,660
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01647-2019 · Cited by 1,619
Self-citation
Metadata
- Authors
- Perrier, A., Roy, P.-M., Sanchez, O., Le Gal, G., Meyer, G., Gourdier, A.-L., Furber, A., Revel, M.-P., Howarth, N., Davido, A., & Bounameaux, H.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2005-04-28
- Volume
- 352
- Issue
- 17
- Pages
- 1760-1768
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W1966605730
- Cited by
- 642
- References
- 22
- FWCI
- 49.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.