Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Open accessAbstract
BACKGROUND: Recently developed technologies for the treatment of type 1 diabetes mellitus include a variety of pumps and pumps with glucose sensors. METHODS: In this 1-year, multicenter, randomized, controlled trial, we compared the efficacy of sensor-augmented pump therapy (pump therapy) with that of a regimen of multiple daily insulin injections (injection therapy) in 485 patients (329 adults and 156 children) with inadequately controlled type 1 diabetes. Patients received recombinant insulin analogues and were supervised by expert clinical teams. The primary end point was the change from the baseline glycated hemoglobin level. RESULTS: At 1 year, the baseline mean glycated hemoglobin level (8.3% in the two study groups) had decreased to 7.5% in the pump-therapy group, as compared with 8.1% in the injection-therapy group (P<0.001). The proportion of patients who reached the glycated hemoglobin target (<7%) was greater in the pump-therapy group than in the injection-therapy group. The rate of severe hypoglycemia in the pump-therapy group (13.31 cases per 100 person-years) did not differ significantly from that in the injection-therapy group (13.48 per 100 person-years, P=0.58). There was no significant weight gain in either group. CONCLUSIONS: In both adults and children with inadequately controlled type 1 diabetes, sensor-augmented pump therapy resulted in significant improvement in glycated hemoglobin levels, as compared with injection therapy. A significantly greater proportion of both adults and children in the pump-therapy group than in the injection-therapy group reached the target glycated hemoglobin level. (Funded by Medtronic and others; ClinicalTrials.gov number, NCT00417989.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A trial comparing a sensor-augmented pump with multiple daily injection therapy showed significant improvement in HbA1C reduction with less hypoglycaemia in the sensor-augmented pump cohort.88,94”
From Type 1 diabetes (2014) · cites this paper as [88]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“A randomised controlled trial in adults with type 1 diabetes reported lower HbA1C concentrations with sensor-augmented pump therapy than with injection therapy, and a greater proportion of patients reaching the targeted levels of HbA1C.88”
From Type 1 diabetes (2014) · cites this paper as [88]
In the citing paper
“The use of rtCGM sensors has proved to be very beneficial for glycemic control [10,16,17].”
From Advanced Diabetes Management Using Artificial Intelligence and Continuous Glucose Monitoring Sensors (2020) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Hirsch, I. B. (2005) · New England Journal of Medicine · doi:10.1056/nejmra040832 · Cited by 667
(2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.193 · Cited by 653
Pickup, J. C., & Sutton, A. J. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02486.x · Cited by 630
Misso, M. L., Egberts, K. J., Page, M., O'Connor, D., & Shaw, J. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005103.pub2 · Cited by 406
Sensor-Augmented Insulin Pump Therapy: Results of the First Randomized Treat-to-Target Study
Hirsch, I. B., Abelseth, J. M., Bode, B. W., Fischer, J. S., KAUFMAN, F. R., Mastrototaro, J. J., Parkin, C. G., Wolpert, H. A., & Buckingham, B. A. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0068 · Cited by 297
Factors Predictive of Use and of Benefit From Continuous Glucose Monitoring in Type 1 Diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0889 · Cited by 250
Flagged first, then by citations
Research works printed but not linked: 2
- Misso ML, 2010, Cochrane Database Syst Rev, 1, CD005103
- Hermanides J, 2009, Diabetologia, 52, S43
Cited by
Sorted by citations
Items 701–800 of 894
Masuda, T., Katakami, N., Taya, N., Miyashita, K., Takahara, M., Kato, K., & Shimomura, I. (2026) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgag224
Advances in diabetes technology: clinical implications, limitations, and future perspectives
Apostolopoulou, M., & Effraimidis, G. (2026) · HORMONES · doi:10.1007/s42000-026-00797-w · Cited by 2
Hypoglycemia in Diabetes Mellitus
Alsahli, M., & Gerich, J. E. (2009) · Springer eBooks · doi:10.1007/978-0-387-09841-8_19 · Cited by 1
Artificial Pancreas: A Review of Fundamentals and Inpatient and Outpatient Studies
Favero, S. D., Bruttomesso, D., & Cobelli, C. (2014) · Frontiers in diabetes · doi:10.1159/000363512 · Cited by 1
Schütz-Fuhrmann, I., Schober, E., Rami-Merhar, B. M., Stadler, M., Bischof, M. G., Fortunat, S., Laimer, M. W., Weitgasser, R., & Prager, R. (2012) · Wiener klinische Wochenschrift · doi:10.1007/s00508-012-0291-1 · Cited by 1
La mesure continue du glucose : présent et avenir Mesure continue du glucose au long cours en 2012
Sola‐Gazagnes, A., & Riveline, J. (2012) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(12)70467-4 · Cited by 1
Les freins et les résistances des soignants et des patients à la mise sous pompe à insuline
Reach, G. (2014) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(14)70867-3 · Cited by 1
Monitorización continua de la glucosa en tiempo real. Indicaciones clínicas probadas
Peralta, F. G., & Padín, C. A. (2011) · Avances en Diabetología · doi:10.1016/j.avdiab.2011.10.001 · Cited by 3
Lin, C.-H., Hsieh, F.-J., Van, Y.-H., & Lo, F. (2015) · BioMed Research International · doi:10.1155/2015/250656 · Cited by 1
de Adana, M. R., Dominguez-Lopez, M.-E., Machado, A., Colomo, N., Ortiz, M. T. A., & C-Soriguer, F. (2011) · Avances en Diabetología · doi:10.1016/j.avdiab.2011.11.003 · Cited by 2
Assessing a patient with an insulin pump
Hughes, L. (2012) · Nursing · doi:10.1097/01.nurse.0000418625.14465.2e · Cited by 1
Update on Care of Children with Type 1 Diabetes
Majidi, S., & Maahs, D. M. (2012) · Advances in Pediatrics · doi:10.1016/j.yapd.2012.04.007 · Cited by 1
Blauw, H., & DeVries, J. H. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0196 · Cited by 1
Continuous glucose monitoring in 2011
Battelino, T., & Bode, B. W. (2012) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2011.02848.x · Cited by 1
Matching Patients to Devices: Diabetes Products Are Not One-Size-Fits-All
Scheiner, G. (2012) · Clinical Diabetes · doi:10.2337/diaclin.30.3.126 · Cited by 1
Personal CGMおよびProfessional CGMの測定精度の検討
宜樹, 楠., 勝野, 朋., 中江理絵, 渡邉佳穂里, 拓, 角., 越智, 史., 徳田八大, 隆文, 赤., 美内, 雅., 宮川, 潤., et al. (2015) · 糖尿病 · doi:10.11213/tonyobyo.58.715 · Cited by 1
Marcus, A. O. (2013) · The Open Diabetes Journal · doi:10.2174/1876524620130905001 · Cited by 1
Wybrane aspekty leczenia dorosłych chorych na cukrzycę typu 1 za pomocą osobistej pompy insulinowej
Gawrecki, A., Duda‐Sobczak, A., Zozulińska‐Ziółkiewicz, D., & Wierusz‐Wysocka, B. (2011) · Via Medica Journals · Cited by 1
Adamson, K., Hassanein, M., Malik, I. A., & Vora, J. P. (2015) · Diabetes Management · doi:10.2217/dmt.15.27 · Cited by 1
Auf dem Weg zum „Closed-loop“-System
Thomas, A., Heinemann, L., & Freckmann, G. (2014) · Der Diabetologe · doi:10.1007/s11428-013-1127-y · Cited by 1
Real-Time Continuous Glucose Monitoring in Children and Adolescents
Battelino, T., Dovč, K., & Bratina, N. (2014) · Frontiers in diabetes · doi:10.1159/000363481 · Cited by 1
Islet Cell or Pancreas Transplantation
Piemonti, L., Socci, C., Nano, R., Maffi, P., & Secchi, A. (2018) · Endocrinology · doi:10.1007/978-3-319-45015-5_23 · Cited by 2
Paediatric type 1 diabetes 2018: Clinical and research insights
Zborovski, S., & Mahmud, F. H. (2018) · Paediatrics & Child Health · doi:10.1093/pch/pxx214 · Cited by 1
Diabetes Technology and Therapy in the Pediatric Age Group
Shalitin, S., & Chase, H. P. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.1512 · Cited by 1
Using Continuous Glucose Monitoring for Patients with Fulminant Type 1 Diabetes
Zhou, J. (2018) · Springer eBooks · doi:10.1007/978-981-10-7074-7_15 · Cited by 1
Pancreas and Islet Cell Transplantation
Sutherland, D. E. R., Gruessner, A. C., Hering, B. J., & Gruessner, R. W. G. (2012) · Elsevier eBooks · doi:10.1016/b978-0-323-07255-7.00047-7 · Cited by 1
Analysis and Design Process for Predicting and Controlling Blood Glucose in Type 1 Diabetic Patients
Gambo, I., Massenon, R., Kolawole, B. A., & Ikono, R. N. (2021) · International Journal of Healthcare Information Systems and Informatics · doi:10.4018/ijhisi.289461 · Cited by 1
Pharmacodynamic Evaluation: Diabetic Methodologies
SANDOW, J. (2020) · Springer eBooks · doi:10.1007/978-3-319-68864-0_33 · Cited by 1
Predicting Hypoglycemia in Diabetic Patients Using Time-Sensitive Artificial Neural Networks
Eljil, K. S., Qadah, G. Z., & Pasquier, M. (2019) · IGI Global eBooks · doi:10.4018/978-1-7998-0414-7.ch069 · Cited by 1
Insulin, other hypoglycemic drugs, and glucagon
Page, R. C. L. (2012) · Side effects of drugs annual · doi:10.1016/b978-0-444-59499-0.00042-8 · Cited by 1
Use of Automated Bolus Calculators for Diabetes Management
Schwartz, F., & Marling, C. R. (2013) · US Endocrinology · doi:10.17925/use.2013.09.02.124 · Cited by 1
Hypoglycemia, insulin resistance, and cardiovascular disease: A possible link
Iqbal, A., Chaudhury, T., & Heller, S. R. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-85732-1.00028-1 · Cited by 1
Machine Learning Based Automated Blood Sugar Regulatory System
Suhas, K. K., Kalyani, G., & Surya, M. V. S. S. (2024) · International Conference on Sustainable Computing and Smart Systems (ICSCSS) · doi:10.1109/icscss60660.2024.10625421 · Cited by 1
Yang, W., Lü, J., Si, S.-C., Wang, W., Li, J., Ma, Y.-X., Zhao, H., & Liu, J. (2025) · World Journal of Diabetes · doi:10.4239/wjd.v16.i4.103002 · Cited by 1
Abordaje terapéutico de la diabetes inestable
Darias-Garzon, R., Bray, B. F. G., & Gómez-Álvarez, B. (2014) · Avances en Diabetología · doi:10.1016/j.avdiab.2014.09.001 · Cited by 1
Zulewski, H. (2015) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2015.11.001 · Cited by 1
Type 1 Diabetes Care: It's Not All Technology
Reach, G. (2014) · Frontiers in diabetes · doi:10.1159/000363521 · Cited by 1
Golukhova, E. Z., Магомедова, Н. М., & Chebotareva, G. E. (2016) · Diabetes Mellitus · doi:10.14341/dm7710 · Cited by 1
Psychosoziale Aspekte aktueller Diabetestechnologien
Lange, K. (2016) · Der Diabetologe · doi:10.1007/s11428-016-0159-5 · Cited by 1
Александрович, К. В., Philippov, Y. I., Владимирович, А. А., Boyarsky, M. D., & Gavrilov, D. A. (2018) · Diabetes Mellitus · doi:10.14341/dm8265 · Cited by 1
Reznik, Y., & Deberles, E. (2019) · Springer eBooks · doi:10.1007/978-3-319-98119-2_3 · Cited by 1
Development of physiological metabolic models in diabetes based on data mining techniques
Georga, E. I. (2019) · University of Ioannina · doi:10.26268/heal.uoi.1420 · Cited by 1
van Beers, C. A. J., & DeVries, J. H. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815583508 · Cited by 1
Islet Cell or Pancreas Transplantation
Piemonti, L., Socci, C., Nano, R., Maffi, P., & Secchi, A. (2018) · Endocrinology · doi:10.1007/978-3-319-27317-4_23-1 · Cited by 2
Grassi, B. A., Caramés, B., Plaza‐Plaza, J. C., Onetto, M. T., Moreno, S., Sandoval, T., Tapia, N., Salas, F. M., & Revello, A. (2022) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2022.108262 · Cited by 1
Moreno-Fernández, J., García-Seco, J. A., Virlaboa-Cebrian, R., Seco, A. M., Muñoz‐Rodríguez, J. R., & Romero, F. J. G. (2023) · Endocrinología Diabetes y Nutrición (English ed ) · doi:10.1016/j.endien.2021.12.012 · Cited by 1
Provision of continuous subcutaneous insulin infusion to type 1 diabetes ‘frequent flyers’
Amato, L. A., Kalolo, R., Yu, W., & Simmons, D. S. (2023) · Internal Medicine Journal · doi:10.1111/imj.16213 · Cited by 1
Type 1 Diabetes: Insulin Treatment
Levy, F. D. (2011) · doi:10.1002/9781444391152.ch4 · Cited by 1
Technology for Hypoglycaemia: CSII and CGM
Schopman, J. E., & DeVries, J. H. (2013) · Wiley eBooks · doi:10.1002/9781118695432.ch9 · Cited by 1
Technological advances in pregnancy complicated by type 1 diabetes
Murphy, H. R., Elleri, D., Kumareswaran, K., & Hovorka, R. (2011) · Practical Diabetes · doi:10.1002/pdi.1568 · Cited by 1
Clinical management of diabetes in children and adolescents
Paul, P. (2015) · doi:10.1002/9781119121725.ch23 · Cited by 1
Future Drug Treatments for Type 1 Diabetes
Sherr, J. L., Cengiz, E., Name, M. A. V., WEINZIMER, S. A., & Tamborlane, W. V. (2016) · Wiley eBooks · doi:10.1002/9781118924853.ch66 · Cited by 1
Canciani, G. N., Stewart, Z. A., & Murphy, H. R. (2017) · Wiley eBooks · doi:10.1002/9781119043805.ch16 · Cited by 1
Sandoval, D. A., Lamos, E. M., Younk, L. M., Hedrington, M. S., & Davis, S. N. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.03833-2 · Cited by 1
Tjota, M. Y., Kozak, B. M., Chang, E. M., & Close, K. L. (2011) · Journal of Diabetes · doi:10.1111/j.1753-0407.2011.00125.x · Cited by 1
New Concepts in Human Telemetry
Carrara, S. (2013) · Springer eBooks · doi:10.1007/978-1-4614-1674-6_4
Bedeutung von körperlicher Aktivität beim Typ-1-Diabetes
der DDG, A. D. U. S., & Zimmer, P. (2011) · Der Diabetologe · doi:10.1007/s11428-010-0618-3
Kontinuerlig subkutan glukosmätning vid diabetes
Johansson, U., Hanås, R., Olsson, P.-O., Olinder, A. L., Persson, M., Werkö, S. S., Jacobson, S., Heintz, E., Akcan, D., Granath, A., et al. (2013)
Keenan, D. B., & Steil, G. M. (2014) · Wiley eBooks · doi:10.1002/9781118873434.ch51
Almokayyad, R. M., & Cuddihy, R. M. (2021) · Wiley eBooks · doi:10.1002/9781119603207.ch7
The Acute Effects of Aerobic and Resistance Exercise on Blood Glucose Levels in Type 1 Diabetes
Yardley, J. E. (2011) · uO Research (University of Ottawa) · doi:10.20381/ruor-3041
Amiel, S. A. (2013) · Wiley eBooks · doi:10.1002/9781118695432.ch7
Glycemic treatment of diabetes mellitus
Kaur, H., & Weinstock, R. S. (2014) · Wiley eBooks · doi:10.1002/9781118887837.ch4
Implantable pumps and artificial and bio‐artificial pancreas system
Tamborlane, W. V., & Palau‐Collazo, M. M. (2015) · Wiley eBooks · doi:10.1002/9781118387658.ch51
Metabolic Control Targets for Patients with Type 1 Diabetes in Clinical Practice
María, G., López‐Tinoco, C., Ortego-Rojo, J., & Aguilar‐Diosdado, M. (2011) · InTech eBooks · doi:10.5772/17792
Diabetes Technology and Treatment in the Pediatric Age Group
Wherrett, D., Bundy, B., Becker, D. J., Dimeglio, L., Gitelman, S., Goland, R., Gottlieb, P. A., Greenbaum, C., Herold, K., Marks, J., et al. (2012) · Diabetes Technology & Therapeutics · doi:10.1111/j.1742-1241.2011.02857.x · Cited by 51
Hart, N. J. (2013) · UA Campus Repository (The University of Arizona)
Frank, M. (2013) · Der Diabetologe · doi:10.1007/s11428-012-0913-2
Algorithms: What Computers Do Best
Manecke, G. R. (2012) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2012.06.016
Martín, A. A., Pascual, A. C., Gómez, F. J., Albarrán, O. G., Gil, A. L., Botella-Serrano, M., & Sánchez, L. F. P. (2015) · Endocrinología y Nutrición (English Edition) · doi:10.1016/j.endoen.2015.04.003
A Perspective of Sensor-Augmented Insulin Pump Therapy in The Treatment of Type 1 Diabetes
Rayfield, E. J. (2014) · Endocrine Practice · doi:10.4158/ep14443.co
Кураева, Т. Л., Andrianova, E. A., Титович, Е. В., & Емельянов, А. О. (2013) · Problems of Endocrinology · doi:10.14341/probl201359657-71
Technologie ter optimalisatie van interventies en behandelresultaten bij kinderen met diabetes
Markowitza, J. T., Harringtona, K. R., & Laffel, L. M. (2014) · Nederlands Tijdschrift voor Diabetologie · doi:10.1007/s12467-014-0022-5
Surveillance du contrôle de la glycémie
Berard, L., Blumer, I. R., Houlden, R. L., Miller, D. B., & Woo, V. C. (2013) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2013.07.037
The use of ultra-short acting insulin preparations for insulin pumps
Андрианова, Е. А. (2012) · Problems of Endocrinology · doi:10.14341/probl201258346-50
Henslee, E., Hatton, A., Welt, S. I., Holmes, J., Penrose, L. L., Prien, S. D., & Farooqi, N. (2014) · Open Journal of Obstetrics and Gynecology · doi:10.4236/ojog.2014.416144
Chevremont, A., Collet-Gaudillat, C., Duvezin-Caubet, P., Franc, S., Gouet, D., Jan, P., Leguerrier, A.-M., Lopez, S., Ozenne, G., Plat, F., et al. (2012) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(12)70475-3
Roe, E. D., Woo, J. S., & Raskin, P. (2012) · Diabetes Management · doi:10.2217/dmt.12.49
Price, D. A., Walker, T. C., & Graham, C. (2015) · Diabetes Care · doi:10.2337/dc14-2428
Hilaire, D. D. L. H. S., Moreau, F., Sigrist, S., Pinget, M., & Jeandidier, N. (2010) · Médecine Nucléaire · doi:10.1016/j.mednuc.2010.07.002
Diabetes in the young: technology, engagement and context
Greene, S. A. (2014) · Practical Diabetes · doi:10.1002/pdi.1877
Pharmacothérapie du diabète de type 1
McGibbon, A., Richardson, C., Hernandez, C. A., & Dornan, J. (2013) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2013.07.005 · Cited by 1
Grunberger, G., Abelseth, J. M., Bailey, T. S., Bode, B. W., Handelsman, Y., Hellman, R., Lane, W. S., Raskin, P., Tamborlane, W. V., & Rothermel, C. (2014)
Evidence-Based Medicine in Pediatric Endocrinology and Diabetes
Butler, G. E., Williams, C. L., Hudson, L. D., & O’Riordan, S. (2012) · Yearbook of pediatric endocrinology · doi:10.1159/000341211
Predictive Low Glucose Suspend: An Option for Routine Outpatient Care
Danne, T., Kordonouri, O., & Thomas, A. (2014) · Frontiers in diabetes · doi:10.1159/000363511
Glucose variability assessment in diabetes mellitus monitoring and control
Fabris, C. (2015) · Padua@research (University of Padova)
Kontinuierliche Glukosemessung im Alltag
Jecht, M. (2016) · Der Diabetologe · doi:10.1007/s11428-015-0056-3
Sensor-Augmented Insulin Pumps vs. Injections
Joy, S. D. S. (2011) · AJN American Journal of Nursing · doi:10.1097/10.1097/01.naj.0000395244.91475.27
Chang, E., Kozak, B., & Close, K. L. (2010) · Journal of Diabetes · doi:10.1111/j.1753-0407.2010.00097.x · Cited by 1
Insulinpumpentherapie bei Kindern, Jugendlichen und Erwachsenen
Stadler, M., Zlamal-Fortunat, S., Schütz-Fuhrmann, I., Rami-Merhar, B. M., Fröhlich-Reiterer, E. E., Hofer, S. E., Mader, J. K., Resl, M., Kautzky‐Willer, A., Weitgasser, R., et al. (2016) · Wiener klinische Wochenschrift · doi:10.1007/s00508-016-0966-0
Kontinuierliche Glukosemessung (CGM – Continuous Glucose Monitoring) bei Diabetes mellitus
Schütz-Fuhrmann, I., Rami-Merhar, B. M., Hofer, S. E., Stadler, M., Bischof, M. G., Zlamal-Fortunat, S., Laimer, M. W., Weitgasser, R., & Prager, R. (2016) · Wiener klinische Wochenschrift · doi:10.1007/s00508-016-0958-0
Sensor augmented pump(SAP)で管理を行った1型糖尿病合併妊娠の1例
中江理絵, 宜樹, 楠., 勝野, 朋., 渡邉佳穂里, 完山昌隆, 拓, 角., 俊宏, 松., 越智, 史., 徳田八大, 隆文, 赤., et al. (2015) · 糖尿病 · doi:10.11213/tonyobyo.58.818
Siegmund, T. (2012) · Der Diabetologe · doi:10.1007/s11428-011-0854-1
Using CGM For Day-To-Day Insulin-Dosing Decisions
Edelman, S. V. (2016) · The Endocrine Society eBooks · doi:10.1210/mtp5.9781943550043.ch17
Regulatory Aspects of New Technology in Diabetes: Can Research Help Us?
de Beaufort, C. E., & Lehmann, B. (2016) · Springer eBooks · doi:10.1007/978-3-319-40242-0_16
Ce que la mesure en continu du glucose apporte à la pompe à insuline
Hanaire, H. P. (2016) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(16)30189-4
Closed Loop Systems In Type 1 Diabetes – A Dream That Might Soon Come True?
Guja, C. (2015) · Romanian Journal of Diabetes Nutrition and Metabolic Diseases · doi:10.1515/rjdnmd-2015-0014
Metadata
- Authors
- Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., Willi, S. M., & Wood, M. A.
- Affiliations
- Park Nicollet Health Services (US)
- Yale University (US)
- Oregon Health & Science University (US)
- University of North Carolina at Chapel Hill (US)
- University of Maryland, Baltimore (US)
- Memorial University of Newfoundland (CA)
- Toronto General Hospital (CA)
- Children's Hospital of Philadelphia (US)
- Helen DeVos Children's Hospital (US)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2010-07-22
- Volume
- 363
- Issue
- 4
- Pages
- 311-320
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2142433802
- Cited by
- 894
- References
- 12
- Citations by year
- 2026: 18 · 2025: 25 · 2024: 38 · 2023: 28 · 2022: 41 · 2021: 50 · 2020: 43 · 2019: 55 · 2018: 66 · 2017: 62 · 2016: 71 · 2015: 78 · 2014: 63 · 2013: 65 · 2012: 88
- FWCI
- 61.06
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Carolina Digital Repository (University of North Carolina at Chapel Hill) (submittedVersion)
- UNC Libraries
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (P30DK079637)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- type 1 diabetes, sensor-augmented insulin pump therapy, multiple daily insulin injections, HbA1c, glycemic control, hypoglycemia, insulin analogues, children and adults, weight gain
- MeSH terms
- Adolescent, Adult, Analysis of Variance, Child, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Injections, Subcutaneous, Insulin, Insulin Infusion Systems, Male, Middle Aged, Diabetic Ketoacidosis, Treatment Outcome, Monitoring, Ambulatory, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review