Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Open accessAbstract
BACKGROUND: Recently developed technologies for the treatment of type 1 diabetes mellitus include a variety of pumps and pumps with glucose sensors. METHODS: In this 1-year, multicenter, randomized, controlled trial, we compared the efficacy of sensor-augmented pump therapy (pump therapy) with that of a regimen of multiple daily insulin injections (injection therapy) in 485 patients (329 adults and 156 children) with inadequately controlled type 1 diabetes. Patients received recombinant insulin analogues and were supervised by expert clinical teams. The primary end point was the change from the baseline glycated hemoglobin level. RESULTS: At 1 year, the baseline mean glycated hemoglobin level (8.3% in the two study groups) had decreased to 7.5% in the pump-therapy group, as compared with 8.1% in the injection-therapy group (P<0.001). The proportion of patients who reached the glycated hemoglobin target (<7%) was greater in the pump-therapy group than in the injection-therapy group. The rate of severe hypoglycemia in the pump-therapy group (13.31 cases per 100 person-years) did not differ significantly from that in the injection-therapy group (13.48 per 100 person-years, P=0.58). There was no significant weight gain in either group. CONCLUSIONS: In both adults and children with inadequately controlled type 1 diabetes, sensor-augmented pump therapy resulted in significant improvement in glycated hemoglobin levels, as compared with injection therapy. A significantly greater proportion of both adults and children in the pump-therapy group than in the injection-therapy group reached the target glycated hemoglobin level. (Funded by Medtronic and others; ClinicalTrials.gov number, NCT00417989.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A trial comparing a sensor-augmented pump with multiple daily injection therapy showed significant improvement in HbA1C reduction with less hypoglycaemia in the sensor-augmented pump cohort.88,94”
From Type 1 diabetes (2014) · cites this paper as [88]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“A randomised controlled trial in adults with type 1 diabetes reported lower HbA1C concentrations with sensor-augmented pump therapy than with injection therapy, and a greater proportion of patients reaching the targeted levels of HbA1C.88”
From Type 1 diabetes (2014) · cites this paper as [88]
In the citing paper
“The use of rtCGM sensors has proved to be very beneficial for glycemic control [10,16,17].”
From Advanced Diabetes Management Using Artificial Intelligence and Continuous Glucose Monitoring Sensors (2020) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Hirsch, I. B. (2005) · New England Journal of Medicine · doi:10.1056/nejmra040832 · Cited by 667
(2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.193 · Cited by 653
Pickup, J. C., & Sutton, A. J. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02486.x · Cited by 630
Misso, M. L., Egberts, K. J., Page, M., O'Connor, D., & Shaw, J. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005103.pub2 · Cited by 406
Sensor-Augmented Insulin Pump Therapy: Results of the First Randomized Treat-to-Target Study
Hirsch, I. B., Abelseth, J. M., Bode, B. W., Fischer, J. S., KAUFMAN, F. R., Mastrototaro, J. J., Parkin, C. G., Wolpert, H. A., & Buckingham, B. A. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0068 · Cited by 297
Factors Predictive of Use and of Benefit From Continuous Glucose Monitoring in Type 1 Diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0889 · Cited by 250
Flagged first, then by citations
Research works printed but not linked: 2
- Misso ML, 2010, Cochrane Database Syst Rev, 1, CD005103
- Hermanides J, 2009, Diabetologia, 52, S43
Cited by
Sorted by citations
Standards of medical care in diabetes—2013
American Diabetes Association (2013) · Diabetes Care · doi:10.2337/dc13-s011 · Cited by 4,369
Atkinson, M. A., Eisenbarth, G. S., & Michels, A. W. (2014) · The Lancet · doi:10.1016/s0140-6736(13)60591-7 · Cited by 2,931
Standards of Medical Care in Diabetes—2012
(2012) · Diabetes Care · doi:10.2337/dc12-s011 · Cited by 2,240
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Type 1 Diabetes Through the Life Span: A Position Statement of the American Diabetes Association
Chiang, J. L., Kirkman, M. S., Laffel, L. M., Peters, A. L., & Authors, O. B. O. T. T. 1. D. S. (2014) · Diabetes Care · doi:10.2337/dc14-1140 · Cited by 1,039
Cryer, P. E., Davis, S. N., & Shamoon, H. (2003) · Diabetes Care · doi:10.2337/diacare.26.6.1902 · Cited by 1,160
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652
Self-citationBeck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635
Self-citationPickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
DiMeglio, L. A., Acerini, C. L., Codner, E., Craig, M. E., Hofer, S. E., Pillay, K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12737 · Cited by 604
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes
Battelino, T., Phillip, M., Bratina, N., Nimri, R., Oskarsson, P., & Bolinder, J. (2011) · Diabetes Care · doi:10.2337/dc10-1989 · Cited by 496
Cappon, G., Vettoretti, M., Sparacino, G., & Facchinetti, A. (2019) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2019.0121 · Cited by 477
Weisman, A., Bai, J.-W., Cardinez, M., Kramer, C. K., & Perkins, B. A. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30167-5 · Cited by 463
Rezvan, P. H., Lee, K. J., & Simpson, J. A. (2015) · BMC Medical Research Methodology · doi:10.1186/s12874-015-0022-1 · Cited by 483
Karges, B., Schwandt, A., Heidtmann, B., Kordonouri, O., Binder, E., Schierloh, U., Boettcher, C., Kapellen, T., Rosenbauer, J., & Holl, R. W. (2017) · JAMA · doi:10.1001/jama.2017.13994 · Cited by 452
Nocturnal Glucose Control with an Artificial Pancreas at a Diabetes Camp
Phillip, M., Battelino, T., Atlas, E., Kordonouri, O., Bratina, N., Miller, S., Biester, T., Stefanija, M. A., Muller, I., Nimri, R., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1206881 · Cited by 431
Ly, T. T., Nicholas, J. A., Retterath, A., Lim, E. M., Davis, E. A., & Jones, T. W. (2013) · JAMA · doi:10.1001/jama.2013.277818 · Cited by 411
Bekiari, E., Kitsios, K., Thabit, H., Tauschmann, M., Athanasiadou, E., Karagiannis, T., Haidich, A.-B., Hovorka, R., & Tsapas, A. (2018) · BMJ · doi:10.1136/bmj.k1310 · Cited by 437
Closed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Aleppo, G., Ruedy, K. J., Riddlesworth, T. D., Kruger, D. F., Peters, A. L., Hirsch, I., Bergenstal, R. M., Toschi, E., Ahmann, A. J., Shah, V. N., et al. (2017) · Diabetes Care · doi:10.2337/dc16-2482 · Cited by 329
Continuous glucose monitoring: A review of the technology and clinical use
Klonoff, D. C., Ahn, D., & Drincic, A. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.08.005 · Cited by 320
Assessment and monitoring of glycemic control in children and adolescents with diabetes
Rewers, M. J., Pillay, K., de Beaufort, C., Craig, M. E., Hanas, R., Acerini, C. L., & Maahs, D. M. (2014) · Pediatric Diabetes · doi:10.1111/pedi.12190 · Cited by 316
Weinstock, R. S., Xing, D., Maahs, D. M., Michels, A., Rickels, M. R., Peters, A. L., Bergenstal, R. M., Harris, B., DuBose, S. N., Miller, K. M., et al. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-1589 · Cited by 338
Insulin delivery methods: Past, present and future
Shah, R., Shah, V. N., Patel, M., & Maahs, D. M. (2016) · International Journal of Pharmaceutical Investigation · doi:10.4103/2230-973x.176456 · Cited by 303
The Past 200 Years in Diabetes
Polonsky, K. S. (2012) · New England Journal of Medicine · doi:10.1056/nejmra1110560 · Cited by 288
Obesity in Type 1 Diabetes: Pathophysiology, Clinical Impact, and Mechanisms
Corbin, K. D., Driscoll, K. A., Pratley, R. E., Smith, S. R., Maahs, D. M., Mayer-Davis, E. J., & Advancing Care for Type 1 Diabetes and Obesity Network (ACT1ON) (2018) · Endocrine Reviews · doi:10.1210/er.2017-00191 · Cited by 262
Peters, A. L., Ahmann, A. J., Battelino, T., Evert, A., Hirsch, I. B., Murad, M. H., Winter, W. E., & Wolpert, H. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-2534 · Cited by 250
(2015) · doi:10.1136/bmj.h3234 · Cited by 258
Advances in technology for management of type 1 diabetes
Beck, R. W., Bergenstal, R. M., Laffel, L. M., & Pickup, J. C. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31142-0 · Cited by 242
Hovorka, R., Kumareswaran, K., Harris, J., Allen, J. M., Elleri, D., Xing, D., Kollman, C., Nodale, M., Murphy, H. R., Dunger, D. B., et al. (2011) · BMJ · doi:10.1136/bmj.d1855 · Cited by 244
Choudhary, P., Rickels, M. R., Senior, P. A., Vantyghem, M.-C., Maffi, P., Kay, T. W., Keymeulen, B., Inagaki, N., Saudek, F., Lehmann, R., et al. (2015) · Diabetes Care · doi:10.2337/dc15-0090 · Cited by 233
Abraham, M. B., Jones, T. W., Naranjo, D. M., Karges, B., Oduwole, A. O., Tauschmann, M., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12698 · Cited by 233
2021 Clinical Practice Guidelines for Diabetes Mellitus of the Korean Diabetes Association
Hur, K. Y., Moon, M. K., Park, J. S., Kim, S., Lee, S., Yun, J., Baek, J. H., Noh, J., Lee, B., Oh, T. J., et al. (2021) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2021.0156 · Cited by 233
Coming of age: the artificial pancreas for type 1 diabetes
Thabit, H., & Hovorka, R. (2016) · Diabetologia · doi:10.1007/s00125-016-4022-4 · Cited by 223
The Effect of Real-Time Continuous Glucose Monitoring in Pregnant Women With Diabetes
Secher, A. L., Ringholm, L., Andersen, H. U., Damm, P., & Mathiesen, E. R. (2013) · Diabetes Care · doi:10.2337/dc12-2360 · Cited by 214
Haidar, A., Legault, L., Messier, V., Mitre, T. M., Leroux, C., & RABASA-LHORET, R. P. R. (2014) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(14)70226-8 · Cited by 219
Outcome measures for artificial pancreas clinical trials: a consensus report
Maahs, D. M., Buckingham, B. A., Castle, J. R., Cinar, A., Damiano, E. R., Dassau, E., DeVries, J. H., Doyle, F. J., Griffen, S. C., Haidar, A., et al. (2016) · Diabetes Care · doi:10.2337/dc15-2716 · Cited by 211
Mauras, N., Beck, R., Xing, D., Ruedy, K., Buckingham, B., Tansey, M., White, N. H., Weinzimer, S. A., Tamborlane, W., Kollman, C., et al. (2012) · Diabetes Care · doi:10.2337/dc11-1746 · Cited by 204
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Fonseca, V. A., Grunberger, G., Anhalt, H., Bailey, T. S., Blevins, T., Garg, S. K., Handelsman, Y., Hirsch, I. B., Orzeck, E. A., Roberts, V. L., et al. (2016) · Endocrine Practice · doi:10.4158/ep161392.cs · Cited by 195
Charleer, S., Mathieu, C., Nobels, F., De Block, C., Radermecker, R. P., Hermans, M. P., Taes, Y., Vercammen, C., T'Sjoen, G., Crenier, L., et al. (2018) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2017-02498 · Cited by 196
Effectiveness of a Regional Prepregnancy Care Program in Women With Type 1 and Type 2 Diabetes
Murphy, H. R., Roland, J. M., Skinner, T. C., Simmons, D., Gurnell, E., Morrish, N. J., Soo, S.-C., Kelly, S., Lim, B., Randall, J., et al. (2010) · Diabetes Care · doi:10.2337/dc10-1113 · Cited by 186
Challenges and recent progress in the development of a closed-loop artificial pancreas
Bequette, B. W. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.007 · Cited by 184
Safety Evaluation of the MiniMed 670G System in Children 7–13 Years of Age with Type 1 Diabetes
Forlenza, G. P., Pinhas‐Hamiel, O., Liljenquist, D. R., Shulman, D. I., Bailey, T. S., Bode, B. W., Wood, M. A., Buckingham, B. A., Kaiserman, K. B., Shin, J., et al. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0264 · Cited by 184
Grunberger, G., Abelseth, J. M., Bailey, T. S., Bode, B. W., Handelsman, Y., Hellman, R., Jovanovič, L., Lane, W. S., Raskin, P., Tamborlane, W. V., et al. (2014) · Endocrine Practice · doi:10.4158/ep14145.ps · Cited by 181
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-2081 · Cited by 180
Poolsup, N., Suksomboon, N., & Kyaw, A. M. (2013) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-5-39 · Cited by 179
Dejgaard, T. F., Frandsen, C. S., Hansen, T. S., Almdal, T., Urhammer, S. A., Pedersen‐Bjergaard, U., Jensen, T. J., Jensen, A. K., Holst, J. J., Tarnow, L., et al. (2015) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(15)00436-2 · Cited by 183
Stacked LSTM based deep recurrent neural network with kalman smoothing for blood glucose prediction
Rabby, M. F., Tu, Y., Hossen, M. I., Lee, I., Maida, A. S., & Hei, X. (2021) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-021-01462-5 · Cited by 197
Insulin therapy and hypoglycemia
McCall, A. L. (2012) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2012.03.001 · Cited by 177
Advanced Diabetes Management Using Artificial Intelligence and Continuous Glucose Monitoring Sensors
Vettoretti, M., Cappon, G., Facchinetti, A., & Sparacino, G. (2020) · Sensors · doi:10.3390/s20143870 · Cited by 176
Nimri, R., Muller, I., Atlas, E., Miller, S., Fogel, A., Bratina, N., Kordonouri, O., Battelino, T., Danne, T., & Phillip, M. (2014) · Diabetes Care · doi:10.2337/dc14-0835 · Cited by 170
Haidar, A., Legault, L., Dallaire, M., Alkhateeb, A., Coriati, A., Messier, V., Cheng, P., Millette, M., Boulet, B., & Rabasa-Lhoret, R. (2013) · Canadian Medical Association Journal · doi:10.1503/cmaj.121265 · Cited by 167
Pozzilli, P., Battelino, T., Danne, T., Hovorka, R., Jarosz-Chobot, P. A., & Renard, É. (2015) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.2653 · Cited by 167
Technology in the management of type 1 diabetes mellitus — current status and future prospects
Tauschmann, M., & Hovorka, R. (2018) · Nature Reviews Endocrinology · doi:10.1038/s41574-018-0044-y · Cited by 165
ISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery
Sherr, J. L., Schoelwer, M., Dos Santos, T. J., Reddy, L., Biester, T., Galderisi, A., van Dyk, J. C., Hilliard, M. E., Berget, C., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13421 · Cited by 152
Accuracy of a Fourth-Generation Subcutaneous Continuous Glucose Sensor
Christiansen, M. P., Garg, S. K., Brazg, R., Bode, B. W., Bailey, T. S., Slover, R. H., Sullivan, A., Huang, S., Shin, J., Lee, S. W., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0087 · Cited by 151
Assessment and management of hypoglycemia in children and adolescents with diabetes
Ly, T. T., Maahs, D. M., Rewers, A., Dunger, D. B., Oduwole, A. O., & Jones, T. W. (2014) · Pediatric Diabetes · doi:10.1111/pedi.12174 · Cited by 154
Prevention of Hypoglycemia by Using Low Glucose Suspend Function in Sensor-Augmented Pump Therapy
Danne, T., Kordonouri, O., Holder, M., Haberland, H., Golembowski, S., Remus, K., Bläsig, S., Wadien, T., Zierow, S., Hartmann, R., et al. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0084 · Cited by 150
Abraham, M. B., Nicholas, J. A., Smith, G. J., Fairchild, J. M., King, B. R., Ambler, G. R., Cameron, F. J., Davis, E. A., Jones, T. W., & on behalf of the PLGM Study Group (2017) · Diabetes Care · doi:10.2337/dc17-1604 · Cited by 143
Closed-Loop Insulin Delivery During Pregnancy Complicated by Type 1 Diabetes
Murphy, H. R., Elleri, D., Allen, J. M., Harris, J. R., Simmons, D. S., Rayman, G. A., Temple, R., Dunger, D. B., Haidar, A., Nodale, M., et al. (2011) · Diabetes Care · doi:10.2337/dc10-1796 · Cited by 137
Risk of Severe Hypoglycemia in Type 1 Diabetes Over 30 Years of Follow-up in the DCCT/EDIC Study
Gubitosi‐Klug, R., Braffett, B. H., White, N. H., Sherwin, R. S., Service, F. J., Lachin, J. M., & Tamborlane, W. V. (2017) · Diabetes Care · doi:10.2337/dc16-2723 · Cited by 140
Berget, C., Messer, L. H., & Forlenza, G. P. (2019) · Diabetes Spectrum · doi:10.2337/ds18-0091 · Cited by 151
Recent progress in design and preparation of glucose-responsive insulin delivery systems
Shen, D., Yu, H., Wang, L., Khan, A., Haq, F., Chen, X., Huang, Q. Y., & Teng, L. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.02.014 · Cited by 138
Slover, R. H., Welsh, J. B., Criego, A. B., WEINZIMER, S. A., Willi, S. M., Wood, M. A., & Tamborlane, W. V. (2011) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2011.00793.x · Cited by 135
Use of Microneedle Array Devices for Continuous Glucose Monitoring: A Review
El-Laboudi, A. H., Oliver, N. S., Cass, A. E. G., & Johnston, D. G. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0188 · Cited by 133
An Overview of Insulin Pumps and Glucose Sensors for the Generalist
McAdams, B., & Rizvi, A. A. (2016) · Journal of Clinical Medicine · doi:10.3390/jcm5010005 · Cited by 138
Tauschmann, M., Allen, J. M., Wilinska, M. E., Thabit, H., Stewart, Z., Cheng, P., Kollman, C., Acerini, C. L., Dunger, D. B., & Hovorka, R. (2015) · Diabetes Care · doi:10.2337/dc15-2078 · Cited by 130
McCall, A. L., Lieb, D. C., Gianchandani, R. Y., MacMaster, H. W., Maynard, G. A., Murad, M. H., Seaquist, E. R., Wolfsdorf, J. I., Wright, R. F., & Wiercioch, W. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac596 · Cited by 139
Šoupal, J., Petruželková, L., Flekač, M., Pelcl, T., Matoulek, M., Daňková, M., Škrha, J., Svačina, Š., & Prázný, M. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0171 · Cited by 126
Blood glucose control algorithms for type 1 diabetic patients: A methodological review
Lunze, K., Singh, T., Walter, M., Brendel, M. D., & Leonhardt, S. K. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2012.09.003 · Cited by 125
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125
Kordonouri, O., Pańkowska, E., Rami-Merhar, B. M., Kapellen, T. M., Coutant, R., Hartmann, R., Lange, K., Knip, M., & Danne, T. (2010) · Diabetologia · doi:10.1007/s00125-010-1878-6 · Cited by 124
Beck, R. W., Riddlesworth, T. D., Ruedy, K. J., Kollman, C., Ahmann, A. J., Bergenstal, R. M., Bhargava, A., Bode, B. W., Haller, S., Kruger, D. F., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30217-6 · Cited by 119
Latres, E., Finan, D. A., Greenstein, J. L., Kowalski, A. J., & Kieffer, T. J. (2019) · Cell Metabolism · doi:10.1016/j.cmet.2019.02.007 · Cited by 124
Sensor-Augmented Pump Therapy for A1C Reduction (STAR 3) Study
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Perkins, B. A., Welsh, J. B., Willi, S. M., et al. (2011) · Diabetes Care · doi:10.2337/dc11-1248 · Cited by 118
Self-citationHaidar, A., Legault, L., Matteau‐Pelletier, L., Messier, V., Dallaire, M., Ladouceur, M., & RABASA-LHORET, R. P. R. (2015) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(15)00141-2 · Cited by 118
Benkhadra, K., Alahdab, F., Tamhane, S. U., McCoy, R. G., Prokop, L. J., & Murad, M. H. (2017) · Endocrine · doi:10.1007/s12020-016-1039-x · Cited by 113
McAuley, S. A., Trawley, S., Vogrin, S., Ward, G. M., Fourlanos, S., Grills, C. A., Lee, M. H., Alipoor, A. M., O’Neal, D. N., O’Regan, N. A., et al. (2022) · Diabetes Care · doi:10.2337/dc21-1667 · Cited by 117
Ólafsdóttir, A. F., Polonsky, W. H., Bolinder, J., Hirsch, I. B., Dahlqvist, S., Wedel, H., Nyström, T., Wijkman, M. O., Schwarcz, E., Hellman, J., et al. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0363 · Cited by 115
Malahi, A. E., Elsen, M. V., Charleer, S., Dirinck, E. L., Ledeganck, K. J., Keymeulen, B., Crenier, L., Radermecker, R. P., Taes, Y., Vercammen, C., et al. (2021) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgab688 · Cited by 115
Type 1 Diabetes in Children and Adolescents
Wherrett, D. K., Huot, C., Mitchell, B. D., & Pacaud, D. (2013) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2013.01.042 · Cited by 115
Circadian Variability of Insulin Sensitivity: Physiological Input for In Silico Artificial Pancreas
Visentin, R., Dalla Man, C., Kudva, Y. C., Basu, A., & Cobelli, C. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0192 · Cited by 113
Use of continuous glucose monitoring in children and adolescents *
Phillip, M., Danne, T., Shalitin, S., Buckingham, B. A., Laffel, L. M., Tamborlane, W. V., Battelino, T., & Participants, F. T. C. F. (2012) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2011.00849.x · Cited by 113
Adherence of self-monitoring of blood glucose in persons with type 1 diabetes in Sweden
Moström, P., Ahlén, E., Imberg, H., Hansson, P. O., & Lind, M. (2017) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2016-000342 · Cited by 110
Dicembrini, I., Cosentino, C., Monami, M., Mannucci, E., & Pala, L. (2021) · Acta Diabetologica · doi:10.1007/s00592-020-01589-3 · Cited by 106
The SWITCH Study Group, Hommel, E. E., Olsen, B. S., Battelino, T., Conget, I., Schütz-Fuhrmann, I., Hoogma, R. P. L. M., Schierloh, U. H. E., Sulli, N., Gough, H., et al. (2014) · Acta Diabetologica · doi:10.1007/s00592-014-0598-7 · Cited by 108
Routine Sensor-Augmented Pump Therapy in Type 1 Diabetes: The INTERPRET Study
Nørgaard, K., Scaramuzza, A. E., Bratina, N., Lalic, N. M., Jarosz-Chobot, P. A., Kocsis, G., Jašinskienė, E., Block, C. E. M. D., Carrette, O., Castañeda, J., et al. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0288 · Cited by 107
Real-Time Improvement of Continuous Glucose Monitoring Accuracy
Facchinetti, A., Sparacino, G., Guerra, S., Luijf, Y. M., DeVries, J. H., Mader, J. K., Ellmerer, M., Benesch, C., Heinemann, L., Bruttomesso, D., et al. (2012) · Diabetes Care · doi:10.2337/dc12-0736 · Cited by 106
ISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Glucose monitoring
Tauschmann, M., Forlenza, G. P., Hood, K. K., Cardona‐Hernandez, R., Giani, E., Hendrieckx, C., DeSalvo, D. J., Laffel, L. M., Saboo, B., Wheeler, B. J., et al. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13451 · Cited by 123
Campbell, F., Murphy, N., Stewart, C., Biester, T., & Kordonouri, O. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12735 · Cited by 102
Biester, T., Berget, C., Boughton, C. K., Cudizio, L., Ekhlaspour, L., Hilliard, M. E., Reddy, L., Sap, S. N. U., Schoelwer, M. J., Sherr, J. L., et al. (2024) · Hormone Research in Paediatrics · doi:10.1159/000543034 · Cited by 114
Abraham, M. B., Karges, B., Dovč, K., Naranjo, D. M., Arbeláez, A. M., Mbogo, J., Javelikar, G., Jones, T. W., & Mahmud, F. H. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13443 · Cited by 112
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Metadata
- Authors
- Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., Willi, S. M., & Wood, M. A.
- Affiliations
- Park Nicollet Health Services (US)
- Yale University (US)
- Oregon Health & Science University (US)
- University of North Carolina at Chapel Hill (US)
- University of Maryland, Baltimore (US)
- Memorial University of Newfoundland (CA)
- Toronto General Hospital (CA)
- Children's Hospital of Philadelphia (US)
- Helen DeVos Children's Hospital (US)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2010-07-22
- Volume
- 363
- Issue
- 4
- Pages
- 311-320
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2142433802
- Cited by
- 894
- References
- 12
- Citations by year
- 2026: 18 · 2025: 25 · 2024: 38 · 2023: 28 · 2022: 41 · 2021: 50 · 2020: 43 · 2019: 55 · 2018: 66 · 2017: 62 · 2016: 71 · 2015: 78 · 2014: 63 · 2013: 65 · 2012: 88
- FWCI
- 61.06
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Carolina Digital Repository (University of North Carolina at Chapel Hill) (submittedVersion)
- UNC Libraries
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (P30DK079637)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- type 1 diabetes, sensor-augmented insulin pump therapy, multiple daily insulin injections, HbA1c, glycemic control, hypoglycemia, insulin analogues, children and adults, weight gain
- MeSH terms
- Adolescent, Adult, Analysis of Variance, Child, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Injections, Subcutaneous, Insulin, Insulin Infusion Systems, Male, Middle Aged, Diabetic Ketoacidosis, Treatment Outcome, Monitoring, Ambulatory, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review