BACKGROUND: Recently developed technologies for the treatment of type 1 diabetes mellitus include a variety of pumps and pumps with glucose sensors. METHODS: In this 1-year, multicenter, randomized, controlled trial, we compared the efficacy of sensor-augmented pump therapy (pump therapy) with that of a regimen of multiple daily insulin injections (injection therapy) in 485 patients (329 adults and 156 children) with inadequately controlled type 1 diabetes. Patients received recombinant insulin analogues and were supervised by expert clinical teams. The primary end point was the change from the baseline glycated hemoglobin level. RESULTS: At 1 year, the baseline mean glycated hemoglobin level (8.3% in the two study groups) had decreased to 7.5% in the pump-therapy group, as compared with 8.1% in the injection-therapy group (P<0.001). The proportion of patients who reached the glycated hemoglobin target (<7%) was greater in the pump-therapy group than in the injection-therapy group. The rate of severe hypoglycemia in the pump-therapy group (13.31 cases per 100 person-years) did not differ significantly from that in the injection-therapy group (13.48 per 100 person-years, P=0.58). There was no significant weight gain in either group. CONCLUSIONS: In both adults and children with inadequately controlled type 1 diabetes, sensor-augmented pump therapy resulted in significant improvement in glycated hemoglobin levels, as compared with injection therapy. A significantly greater proportion of both adults and children in the pump-therapy group than in the injection-therapy group reached the target glycated hemoglobin level. (Funded by Medtronic and others; ClinicalTrials.gov number, NCT00417989.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A trial comparing a sensor-augmented pump with multiple daily injection therapy showed significant improvement in HbA1C reduction with less hypoglycaemia in the sensor-augmented pump cohort.88,94”
From Type 1 diabetes (2014) · cites this paper as [88]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“A randomised controlled trial in adults with type 1 diabetes reported lower HbA1C concentrations with sensor-augmented pump therapy than with injection therapy, and a greater proportion of patients reaching the targeted levels of HbA1C.88”
From Type 1 diabetes (2014) · cites this paper as [88]
In the citing paper
“The use of rtCGM sensors has proved to be very beneficial for glycemic control [10,16,17].”
From Advanced Diabetes Management Using Artificial Intelligence and Continuous Glucose Monitoring Sensors (2020) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Hirsch, I. B. (2005) · New England Journal of Medicine · doi:10.1056/nejmra040832 · Cited by 667
(2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.193 · Cited by 653
Pickup, J. C., & Sutton, A. J. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02486.x · Cited by 630
Misso, M. L., Egberts, K. J., Page, M., O'Connor, D., & Shaw, J. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005103.pub2 · Cited by 406
Sensor-Augmented Insulin Pump Therapy: Results of the First Randomized Treat-to-Target Study
Hirsch, I. B., Abelseth, J. M., Bode, B. W., Fischer, J. S., KAUFMAN, F. R., Mastrototaro, J. J., Parkin, C. G., Wolpert, H. A., & Buckingham, B. A. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0068 · Cited by 297
Factors Predictive of Use and of Benefit From Continuous Glucose Monitoring in Type 1 Diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0889 · Cited by 250
Raccah, D., Sulmont, V., Reznik, Y., Guerci, B., Renard, É., Hanaire, H. P., Jeandidier, N., & Nicolino, M. P. (2009) · Diabetes Care · doi:10.2337/dc09-0750 · Cited by 239
Davis, S. N., Horton, E. S., Battelino, T., Rubin, R. R., Schulman, K. A., & Tamborlane, W. V. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0145 · Cited by 40
Research works printed but not linked: 2
- Misso ML, 2010, Cochrane Database Syst Rev, 1, CD005103
- Hermanides J, 2009, Diabetologia, 52, S43
Cited by
Sorted by citations
Standards of medical care in diabetes—2013
American Diabetes Association (2013) · Diabetes Care · doi:10.2337/dc13-s011 · Cited by 4,369
Atkinson, M. A., Eisenbarth, G. S., & Michels, A. W. (2014) · The Lancet · doi:10.1016/s0140-6736(13)60591-7 · Cited by 2,931
Standards of Medical Care in Diabetes—2012
(2012) · Diabetes Care · doi:10.2337/dc12-s011 · Cited by 2,240
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Metadata
- Authors
- Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., Willi, S. M., & Wood, M. A.
- Affiliations
- Park Nicollet Health Services (US)
- Yale University (US)
- Oregon Health & Science University (US)
- University of North Carolina at Chapel Hill (US)
- University of Maryland, Baltimore (US)
- Memorial University of Newfoundland (CA)
- Toronto General Hospital (CA)
- Children's Hospital of Philadelphia (US)
- Helen DeVos Children's Hospital (US)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2010-07-22
- Volume
- 363
- Issue
- 4
- Pages
- 311-320
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2142433802
- Cited by
- 894
- References
- 12
- Citations by year
- 2026: 18 · 2025: 25 · 2024: 38 · 2023: 28 · 2022: 41 · 2021: 50 · 2020: 43 · 2019: 55 · 2018: 66 · 2017: 62 · 2016: 71 · 2015: 78 · 2014: 63 · 2013: 65 · 2012: 88
- FWCI
- 61.06
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Carolina Digital Repository (University of North Carolina at Chapel Hill) (submittedVersion)
- UNC Libraries
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (P30DK079637)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- type 1 diabetes, sensor-augmented insulin pump therapy, multiple daily insulin injections, HbA1c, glycemic control, hypoglycemia, insulin analogues, children and adults, weight gain
- MeSH terms
- Adolescent, Adult, Analysis of Variance, Child, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Injections, Subcutaneous, Insulin, Insulin Infusion Systems, Male, Middle Aged, Diabetic Ketoacidosis, Treatment Outcome, Monitoring, Ambulatory, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review