Wind Response Control of Building with Variable Stiffness Tuned Mass Damper Using Empirical Mode Decomposition/Hilbert Transform
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The effectiveness of a novel semiactive variable stiffness-tuned mass damper (SAIVS-TMD) for the response control of a wind-excited tall benchmark building is investigated in this study. The benchmark building considered is a proposed 76-story concrete office tower in Melbourne, Australia. It is a slender building 306 m tall with a height to width ratio of 7.3; hence, it is wind sensitive. Across wind load data from wind tunnel tests are used in the present study. The objective of this study is to evaluate the new SAIVS-TMD system, that has the distinct advantage of continuously retuning its frequency due to real time control and is robust to changes in building stiffness and damping. In comparison, the passive tuned mass damper (TMD) can only be tuned to a fixed frequency. A time varying analytical model of the tall building with the SAIVS-TMD is developed. The frequency tuning of the SAIVS-TMD is achieved based on empirical mode decomposition and Hilbert transform instantaneous frequency algorithm developed by the writers. It is shown that the SAIVS-TMD can reduce the structural response substantially, when compared to the uncontrolled case, and it can reduce the response further when compared to the case with TMD. Additionally, it is shown the SAIVS-TMD reduces response even when the building stiffness changes by ±15% and is robust; whereas, the TMD loses its effectiveness under such building stiffness variations. It is also shown that SAIVS-TMD can reduce the response similar to an active TMD; however, with an order of magnitude less power consumption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
(2009) · Encyclopedia of Neuroscience · doi:10.1007/978-3-540-29678-2_6014 · Cited by 2,850
Phenomenological Model for Magnetorheological Dampers
Spencer, B. F., Dyke, S. J., Sain, M. K., & Carlson, J. D. (1997) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1997)123:3(230 · Cited by 2,055
Active Structural Control: Theory and Practice
Soong, T. T., & Spencer, B. F. (1992) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1992)118:6(1282 · Cited by 574 · cited 1×
“~Soong 1990; Spencer and Nagarajaiah 2 Yang et al. 2004! and active mass dampers~Soong 1990; Rein horn et al. 1993; Ikeda et al. 2001; Spencer and Nagara 2003! have also been developed and implemented widely fo active response control of buildings and bridges.”
BackgroundRamachandra Rao, A., Hamed, K. H., & Chen, H.-L. (2003) · Water Science and Technology Library · doi:10.1007/978-94-010-0117-5_5 · Cited by 437
Dynamic characterization of multiple tuned mass dampers and some design formulas
Abé, M., & Fujino, Y. (1994) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290230802 · Cited by 329 · cited 1×
“TMD is very sensitive to tuning quency ratio, even when optimally designed~Den Hartog 1947!. MTMD ~Igusa and Xu 1992; Abe and Fujino 1994; Kareem Klein 1995! can overcome the limitation of the TMD by distr uting the natural frequencies of a number of TMDs around fundamental natural frequency of the…”
BackgroundDynamic characteristics of multiple substructures with closely spaced frequencies
Xu, K., & Igusa, T. (1992) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290211203 · Cited by 326
Seismic response controlled structure with Active Variable Stiffness system
Kobori, T., Takahashi, M., Nasu, T., Niwa, N., & Ogasawara, K. (1993) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290221102 · Cited by 311
Performance of Multiple Mass Dampers under Random Loading
Kareem, A., & Kline, S. (1995) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1995)121:2(348) · Cited by 306
Semi‐Active versus Passive or Active Tuned Mass Dampers for Structural Control
Hrovat, D., Barak, P., & Rabins, M. (1983) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1983)109:3(691 · Cited by 291
Research works printed but not linked: 5
- Den Hartog J. P. (1947). Mechanical vibrations McGraw-Hill New York.
- 10.1088/0964-1726/7/5/010 · doi:10.1088/0964-1726/7/5/010
- 10.1002/eqe.4290210202 · doi:10.1002/eqe.4290210202
- Nagarajaiah S. and Mate D. (1998). “Semiactive control of continuously variable stiffness system.” Proc. 2nd World Conf. Struct. Control Vol. 1 Kyoto Japan 397–405.
- Nagarajaiah S. and Varadarajan N. (2000). “Novel semiactive variable stiffness tuned mass damper with real time tuning capability.” Proc. 13th Engineering Mechanics Conf. (CD-ROM) ASCE Reston Va.
Cited by
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Vibration suppression of structures using tuned mass damper technology: A state-of-the-art review
Yang, F., Sedaghati, R., & Esmailzadeh, E. (2022) · Journal of Vibration and Control · doi:10.1177/1077546320984305 · Cited by 306
Nagarajaiah, S. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.349 · Cited by 256
Self-citationNagarajaiah, S., & Varadarajan, N. (2005) · Engineering Structures · doi:10.1016/j.engstruct.2004.10.015 · Cited by 212
Self-citationNagarajaiah, S., & Basu, B. (2009) · Earthquake Engineering and Engineering Vibration · doi:10.1007/s11803-009-9120-6 · Cited by 201
“…a key role in the development of new time-frequency based controllers for semiactive, smart tuned mass dampers (Nagarajaiah et al., 1999; Nagarajaiah and Varadarajan, 2001, 2005; Nagarajaiah and Sonmez, 2007; Nagarajaiah, 2009; Narasimhan and Nagarajaiah, 2005; Varadarajan and Nagarajaiah, 2004).”
BackgroundSelf-citationStructures with Semiactive Variable Stiffness Single/Multiple Tuned Mass Dampers
Nagarajaiah, S., & Sonmez, E. (2007) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2007)133:1(67 · Cited by 190
“Recently, the STMD device has been studied by developing on-line tuning using empirical mode decomposition-Hilbert transform and shorttime Fourier transform STFT algorithms by Varadarajan and Nagarajaiah 2004 and Nagarajaiah and Varadarajan 2005, which tune the frequency of STMD and reduce the primary structural respo…”
BackgroundMethodSelf-citationBarbosh, M., Singh, P., & Sadhu, A. (2020) · Smart Materials and Structures · doi:10.1088/1361-665x/aba539 · Cited by 170
“Unlike damage detection, Varadarajan and Nagarajaiah (2004) investigated the effect of the semi-active variable stiffness-tuned mass damper to control and reduce the response of high-rise buildings subjected to wind force.”
BackgroundWang, L., Shi, W., Li, X., Zhang, Q., & Zhou, Y. (2019) · Structural Control and Health Monitoring · doi:10.1002/stc.2377 · Cited by 168
Estimation of optimum tuned mass damper parameters via machine learning
Yucel, M., Bekdaş, G., Nigdeli, S. M., & Sevgen, S. (2019) · Journal of Building Engineering · doi:10.1016/j.jobe.2019.100847 · Cited by 163
Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review
Rahimi, F., Aghayari, R., & Samali, B. (2020) · Civil Engineering Journal · doi:10.28991/cej-2020-03091571 · Cited by 138
Yang, D.-H., Shin, J.-H., Lee, H., Kim, S.-K., & Kwak, M. K. (2017) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2016.12.036 · Cited by 107
Vibration control of buildings by using partial floor loads as multiple tuned mass dampers
Sakr, T. A. (2017) · HBRC Journal · doi:10.1016/j.hbrcj.2015.04.004 · Cited by 32
Bioinspired Tuned Mass Damper for Mitigation of Wind-Induced Building Excitation
Kwon, I. Y., Yang, H. T., Hansma, P. K., & Randall, C. J. (2017) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001881 · Cited by 12
Seismic Energy Dissipation of Inelastic Structures with Tuned Mass Dampers
(2008) · doi:10.1061/(asce)0733-9399(2008)134:2(163
Metadata
- Authors
- Varadarajan, N., & Nagarajaiah, S.
- Venue
- Journal of Engineering Mechanics
- Published
- 2004-04
- Volume
- 130
- Issue
- 4
- Pages
- 451-458
- ISSN
- 0733-9399 (ISSN-L)
- 1943-7889
- DOI
- 10.1061/(asce)0733-9399(2004)130:4(451
- OpenAlex
- W2137412949
- Cited by
- 172
- References
- 21
- FWCI
- 27.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.