The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Thermal and ambient-induced deflections of scanning force microscope cantilevers
Abstract
The deflection of scanning force microscope cantilevers, metal coated on one side, is significantly influenced by both thermal heating and variations in relative humidity. For constant relative humidity, the deflection of the cantilever drifts due to laser heating and eventually reaches a steady-state value. For a thermally stabilized cantilever, the deflection varies linearly with relative humidity. Exposure to other vapors, such as mercury, changes the inherent deflection of the cantilever. Relative amounts of adsorbates on the cantilever can be estimated from shifts in the cantilever resonance frequency with picogram mass resolution. The cantilever deflection as well as changes in resonance frequency due to vapor adsorption can be used as basis for novel chemical sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
The general theory of van der Waals forces
Dzyaloshinskii, I. E., Lifshitz, E. M., & Pitaevskii, L. P. (1961) · Advances in Physics · doi:10.1080/00018736100101281 · Cited by 1,737
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
From Molecules to Cells: Imaging Soft Samples with the Atomic Force Microscope
Radmacher, M., Tillmann, R. W., Fritz, M., & Gaub, H. E. (1992) · Science · doi:10.1126/science.1411505 · Cited by 900
Regulation of a microcantilever response by force feedback
Mertz, J., Marti, O., & Mlynek, J. (1993) · Applied Physics Letters · doi:10.1063/1.109413 · Cited by 265
Friction effects in the deflection of atomic force microscope cantilevers
Warmack, R. J. B., Zheng, X.-J., Thundat, T. G., & Allison, D. P. (1994) · Review of Scientific Instruments · doi:10.1063/1.1145144 · Cited by 108
Self-citationYuan, J.-Y., Shao, Z., & Gao, C. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.863 · Cited by 61
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Cantilever transducers as a platform for chemical and biological sensors
Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1763252 · Cited by 1,117
Feedback amplification of fibrosis through matrix stiffening and COX-2 suppression
Liu, F., Mih, J. D., Shea, B. S., Kho, A. T., Sharif, A. S., Tager, A. M., & Tschumperlin, D. J. (2010) · Journal of Cell Biology · doi:10.1083/jcb.201004082 · Cited by 810
Micromechanical cantilever-based biosensors
Raiteri, R., Grattarola, M., Butt, H.-J., & Skládal, P. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00856-5 · Cited by 734
Cantilever-like micromechanical sensors
Boisen, A., Dohn, S., Keller, S. S., Schmid, S., & Tenje, M. (2011) · Reports on Progress in Physics · doi:10.1088/0034-4885/74/3/036101 · Cited by 566
Metadata
- Authors
- Thundat, T., Warmack, R. J., Chen, G. Y., & Allison, D. P.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1994-05-23
- Volume
- 64
- Issue
- 21
- Pages
- 2894-2896
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2044428681
- Cited by
- 419
- References
- 7
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.